Spelling suggestions: "subject:"prosthesis""
41 |
Development of injectable hydrogels for nucleus pulposus replacement /Thomas, Jonathan D. Lowman, Anthony M. Marcolongo, Michele S. January 2006 (has links)
Thesis (Ph. D.)--Drexel University, 2006. / Includes abstract and vita. Includes bibliographical references (leaves 170-193).
|
42 |
Haptic Discrimination of Object Size Using Vibratory Sensory SubstitutionJanuary 2016 (has links)
abstract: Humans constantly rely on a complex interaction of a variety of sensory modalities in order to complete even the simplest of daily tasks. For reaching and grasping to interact with objects, the visual, tactile, and proprioceptive senses provide the majority of the information used. While vision is often relied on for many tasks, most people are able to accomplish common daily rituals without constant visual attention, instead relying mainly on tactile and proprioceptive cues. However, amputees using prosthetic arms do not have access to these cues, making tasks impossible without vision. Even tasks with vision can be incredibly difficult as prosthesis users are unable to modify grip force using touch, and thus tend to grip objects excessively hard to make sure they don’t slip.
Methods such as vibratory sensory substitution have shown promise for providing prosthesis users with a sense of contact and have proved helpful in completing motor tasks. In this thesis, two experiments were conducted to determine whether vibratory cues could be useful in discriminating between sizes. In the first experiment, subjects were asked to grasp a series of hidden virtual blocks of varying sizes with vibrations on the fingertips as indication of contact and compare the size of consecutive boxes. Vibratory haptic feedback significantly increased the accuracy of size discrimination over objects with only visual indication of contact, though accuracy was not as great as for typical grasping tasks with physical blocks. In the second, subjects were asked to adjust their virtual finger position around a series of virtual boxes with vibratory feedback on the fingertips using either finger movement or EMG. It was found that EMG control allowed for significantly less accuracy in size discrimination, implying that, while proprioceptive feedback alone is not enough to determine size, direct kinesthetic information about finger position is still needed. / Dissertation/Thesis / Masters Thesis Bioengineering 2016
|
43 |
Analise fotoelastica das tensões induzidas por infra-estruturas implanto-suportadas obtidas pelas tecnicas de cimentação dos cilindros e soldagem a laser, antes e apos eletroerosão / Photoelastic analysis of stress transmitted from implant-supported frameworks achieved by cilinders lutingand laser welding techniques before and after eletric discharge machiningBarberi, Juliana Tamião 30 May 2007 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T19:07:40Z (GMT). No. of bitstreams: 1
Barberi_JulianaTamiao_M.pdf: 6032748 bytes, checksum: 3f9207c911e4693fec735f279de88fa3 (MD5)
Previous issue date: 2007 / Resumo: O presente estudo avaliou o assentamento passivo em infra-estruturas de próteses fixas implanto-suportadas, através de análise fotoelástica da distribuição de tensões em virtude do grau de desadaptação. A partir de uma matriz metálica no formato e dimensões similares a um arco mandibular, contendo cinco análogos de pilares Micro-Unit (Conexão ¿ São Paulo), foram confeccionadas duas estruturas metálicas fundidas em titânio comercialmente puro (Tritan® ¿ Dentaurum ¿ Alemanha), obtidas pelas seguintes técnicas: Estrutura I, cilindros cimentados com ionômero de vidro modificado por resina (RelyX® Luting 2 ¿ 3M ESPE); e Estrutura II, cilindros soldados a laser e subsequente refinamento por eletroerosão (EDM). A partir de um molde de silicone de duplicação foi confeccionado um modelo em resina fotoelástica (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Guarulhos ¿ São Paulo) com cinco implantes incorporados e pilares Micro-Unit. As estruturas foram então submetidas à análise fotoelástica conduzida pelo aperto dos parafusos na seqüência preconizada 3,2,4,1,5. Seqüencialmente, mensurações foram realizadas na interface estrutura/pilar intermediário com auxílio de um microscópio mensurador, com precisão de 0,0005mm (STM Digital ¿ Olympus ¿ Japão) através do teste do parafuso único. A estrutura dos cilindros cimentados apresentou os melhores resultados com menor valor de desadaptação (42,37 mm) e maior distribuição das tensões, quando comparada à estrutura dos cilindros soldados a laser (83,66 mm), a qual após o procedimento de EDM e subseqüente análise fotoelástica demonstrou redução no grau de desadaptação (53,7 mm) e melhor distribuição de tensão. Pode-se concluir que o processo de cimentação dos cilindros à estrutura optimiza a adaptação marginal desta e minimiza os padrões de tensões, sendo eficaz para a obtenção do assentamento passivo / Abstract: The purpose of the study was to evaluate the passive fit of fixed implantsupported prothesis titanium frameworks, through photoelastic stress analysis. Two frameworks welded in commercially pure titanium (Tritan® ¿ Dentaurum ¿ Germany) were fabricated by two methods based on a metal model composed of five analogous Micro-Unit (Conexão ¿ São Paulo): Framework I, abutment-luted with resin-modified glass ionomer luting cement (RelyX® Luting 2 ¿ 3M ESPE); and framework II, cylinders laser-welding technique and was then refined using electric discharge machining. Photoelastic model was obtained (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Garulhos ¿ São Paulo) with five fixtures and abutments Micro-Unit. Strains were produced around the implant bodies when screws retaining the prosthesis were tightened sequence 3,2,4,1,5, and strains were evaluated by photoelastic analysis. The interfacial gaps between the abutments and fixture were measuremented with an optical microscope (STM Digital ¿ Olympus ¿ Japan) 0,0005mm of precision. The interfacial gaps were smaller in the abutment-luted framework (42,37 mm), demonstrated the lower stress when compared to the laser-welded cylinder framework (83,66 mm). The electric discharge machining (EDM) reduced the gaps at the interfaces (53,7 mm) and the strains for framework welded. It may be concluded that the process of abutment-luted realized in frameworks improves the precise fit of it, can be recommended of achieving precise fit of implant-supported prothesis / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
44 |
Análise da passividade e adaptação de infraestruturas de Ti com soldagem a laser vertical e horizontal de borda, cilindro cimentado ou processo CAD/CAM / Analysis of passivity and adaptation of infrastructures Ti laser welding with vertical and horizontal edge, cemented cylinder or process CAD/CAMSilva, Maíra Daysê Moreira Serra e 06 July 2013 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T01:37:01Z (GMT). No. of bitstreams: 1
Silva_MairaDayseMoreiraSerrae_D.pdf: 4199149 bytes, checksum: b778f7577a1646d77910c20b05ac939f (MD5)
Previous issue date: 2013 / Resumo: Este estudo comparou diferentes técnicas para obtenção de infraestruturas protéticas implantossuportadas com menores desajustes verticais e melhor passividade. A partir de uma matriz metálica com paredes planas e dimensões de altura, comprimento e espessura de 25 X 70 X 10 mm, contendo 4 análogos de microunits (3,75 X 13 mm), foram confeccionadas 25 amostras separadas em cinco grupos (n=5): Grupo IM infraestruturas fundidas em monobloco; Grupo ISS infraestruturas fundidas seccionadas e unidas com um ponto de solda a laser; Grupo ICC infraestruturas parafusadas com cilindros cimentados; Grupo ISB infraestruturas submetidas à soldagem de borda com solda a laser; Grupo TCC infraestruturas confeccionadas pelo processo CAD/CAM (Computer Aided Design/Computer Aided Manufacturing). Foram realizadas leituras de desadaptação marginal vertical das infraestruturas, sobre a matriz metálica, em microscópio óptico com precisão de 1,0 ?m e aumento de 120 X. As desadaptações foram quantificadas seguindo o protocolo do teste do parafuso único após torque no parafuso protético de uma das extremidades ( 10 Ncm) e verificado a adaptação nos outros três pilares. Com o intuito de avaliar a passividade das infraestruturas foram analisadas, pela técnica da fotoelasticidade, as tensões geradas nos implantes após aperto de todos os parafusos com auxílio de polariscópio circular equipado com software, capaz de realizar análises qualitativa e quantitativa das tensões. Os valores de desajuste e tensão foram tabulados e submetidos à análise estatística (SAS versão 9.1 - The SAS Institute, Cary, NC, EUA). Para as comparações entre técnica e desajuste vertical foi feito o teste ANOVA com um fator e teste de Tukey (? = 0,05%), e para as comparações das tensões cisalhantes foi realizado ANOVA dois fatores e teste de Tukey (? = 0,05%). Os resultados mostraram que o grupo IM apresentou maior desadaptação marginal; os grupos ISS e ICC apresentaram significativa adaptação marginal e menor concentração de tensão quando comparado ao grupo IM, com a vantagem do grupo ICC eliminar o seccionamento e soldagem; o grupo ISB apresentou melhor adaptação marginal quando comparadas as infraestruturas fundidas, porém com significativa concentração de franjas e tensão nos implantes, e a tecnologia CAD/CAM produziu infraestruturas com melhor adaptação marginal e tensão distribuída de forma equilibrada. Pode-se concluir que técnicas que eliminam ou reduzem pontos de solda como, ISS, ICC e TCC melhoram a passividade e diminuem desadaptação marginal vertical de infraestruturas extensas implantossuportadas / Abstract: This study compared different techniques for obtaining prosthetic implantinfrastructures with lower vertical misfits and passivity. Starting from an metallic with plane walls and dimensions of height, length and thickness of 25 X 70 X 10 mm containing four microunits analogues (3.75 X 13 mm), were prepared twentyfive samples were prepared and divided into five groups (n = 5): Group IM onepiece casted frameworks, Group ISS one-piece casted frameworks sectioned and welded with laser welding; Group ICC with cylinders cemented; Group ISB with cylinders laser-welded, Group TCC frameworks fabricated by the CAD/CAM process (Computer Aided Design / Computer Aided Manufacturing). Measurements were accomplished of the frameworks vertical misfit on metal matrix, in an optical microscope with accuracy of 1.0?m and increased 120 X. The Misfits were quantified according to the protocol of the single screw test after 10Ncm torque on the prosthetic screw and verified the adjustment on the other pillars. Aiming to evaluate the passive infrastructure were analyzed by the technique of photoelasticity the tensions generated in the implants after torque of all screws with the aid of a circular polariscope equipped with software able of performing qualitative and quantitative analyzes of tensions. The misfit values and tension were subjected to statistical analysis (SAS version 9.1 - The SAS Institute, Cary, NC, USA). For comparisons between technical and vertical misfit was done with one way - ANOVA and Tukey's test. (? = 0,05%), and for comparisons of fringe orders and shear stress was performed two factors ANOVA and Tukey test (? = 0,05%). The results showed that the IM group showed higher marginal discrepancy; group ISS and ICC showed significant marginal adaptation and lower stress concentration when compared to IM, with the advantage the ICC group of eliminate sectioning and welding; ISB group showed better marginal adaptation in casted frameworks, but with significant concentration fringe and tension in implants and CAD/CAM technology produced frameworks with best average marginal fit and tension. It can be concluded that techniques that reduce or eliminate welding points as ISS, ICC and TCC improves the passivity and reduce vertical misfit of extensive infrastructure supported by implants / Doutorado / Protese Dental / Doutora em Clínica Odontológica
|
45 |
Geometric and mechanical modelling of the human locomotor systemLu, Tung-Wu January 1997 (has links)
A critical review of studies related to the modelling of the human locomotor system is given. Kinematic and dynamic modelling and analysis of the pelvis-leg apparatus as an ensemble of four rigid body segments are described. Experiments were performed on two patients with custom-made instrumented massive proximal femoral prostheses implanted after tumour resection. Telemetered axial forces transmitted along the prostheses, together with kinematic, force plate and electromyographic data, were recorded synchronously during level walking, single and double leg stance, and isometric tests of the hip muscles. A sagittal plane model of the locomotor system, with an anatomical model of the knee joint, was developed from an existing model and used for a comparative study of methods for the calculation of the internal forces. A three-dimensional computer graphics-based animated model of the locomotor system was developed, with the hip as a ball-and-socket joint, the knee as a parallel spatial mechanism and the ankle as a two-hinge complex. Thirty-four muscles or muscle groups were included. A method for the determination of the orientation of multi-joint systems from surface markers was developed to take account of measurement errors including skin movement artefacts. Both the 2D and 3D models of the locomotor system were evaluated and validated quantitatively with the telemetered femoral axial forces. It is concluded that (a) a significant part of the bending moments along limbs are transmitted by a combination of tensile forces in muscles and compressive forces in bones so that moments transmitted by the bones are much less than the limb moments, (b) bi-articular muscles play a major role in modulating forces in bones, (c) appropriate simulation of muscle forces is important in experimental or theoretical studies of load transmission along bones, (d) computer graphics-based modelling and animation are important tools in bridging the gap between clinical users and biomechanists.
|
46 |
Distribuição de tensões ao redor dos implantes em duas condições de desajuste vertical / Stress Distribution around implants in two conditions of vertical misfitCastro, Gabriela Cassaro de, 1986- 02 September 2015 (has links)
Orientador: Mauro Antonio de Arruda Nóbilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T22:26:53Z (GMT). No. of bitstreams: 1
Castro_GabrielaCassarode_D.pdf: 33391431 bytes, checksum: 639a953ad32049093199c81dd2ea3cb7 (MD5)
Previous issue date: 2015 / Resumo: Muito se discute sobre importância da passividade, seus efeitos mecânicos e biológicos e a dificuldade em sua obtenção. Devido aos procedimentos inerentes ao processo de confecção da infraestrutura metálica, desde a moldagem à fundição, distorções são incorporadas. Estas tornam-se preocupação biomecânica por gerar tensão no conjunto prótese-implante-osso. Propõe-se avaliar as tensões ao redor dos implantes em infraestruturas de Titânio para prótese total fixa sobre 4 implantes, com diferentes desajustes marginais por meio da fotoelasticidade. Quatro implantes hexágono externo 4,1 x 11,5 mm, foram posicionados sobre uma matriz simulando uma mandíbula edêntula e nomeados da esquerda para direita em A, B, C e D. Aos implantes, foram aparafusados mini-pilares cônicos e entre os pilares e a infraestrutura foram posicionados anéis espaçadores com dimensões conhecidas: para o grupo HE300 (n=5) foi simulado desajuste, respectivamente de A-D: 0 µm, 100 µm, 200 µm e 300 µm, para o grupo HE100 (n=5) apenas desajuste de 100 µm no implante D. A matriz foi duplicada em resina fotoelástica utilizando as infraestruturas como transferente de moldagem. Foram realizadas medições em 6 pontos em cada implante através do teste do parafuso único, em microscópio óptico, para aferir a desadaptação real obtida. Para obter as imagens fotoelásticas padronizadas a infraestrutura foi aparafusada aos pilares e levadas ao polariscópio circular. A tensão cisalhante máxima (Kgf) foi aferida em 7 pontos ao redor de cada implante e comparados quanto as tensões conjuntas em todos os implantes, ao redor de cada implante e na região cervical e apical. Os dados foram tabulados e submetidos à análise estatística pelo teste t de Student, para avaliar a diferença entre as médias de desadaptação e tensão e o teste de correlação de Spearman para verificar a relação entre tensão e desadaptação. A desadaptação média observada foi de 56,96 (±13,23) ?m para o grupo HE100 e de 194,53 (±162,98) ?m para HE300, apresentando diferença entre os grupos. Com relação à tensão, os grupos HE300 e HE100 mostraram-se iguais estatisticamente (p = 0,291). Mas verificou-se correlação positiva entre desadaptação e tensão em HE100 e HE300. Os implantes B, C e D apresentaram maior tensão no grupo HE100 (p < 0,0001) e no grupo HE300, não foi constatado diferença entre os implantes. As tensões foram maiores na cervical do que na região apical em ambos grupos, para HE 100: 36,92 (±9,33) Kgf na região cervical e 17,78 (±4,09) Kgf na região apical; para HE300: 50,37 (±13,20) Kgf na região cervical e para a região apical 21,20 (±3,95) Kgf. O grupo HE300 exibiu significantemente maior valor de tensão na região cervical (p = 0,012). Conclui-se que o desajuste obtido em HE300 foi maior que do grupo HE100 e gerou maior tensão na região cervical. Ao analisar os implantes em conjunto as tensões foram semelhantes estatisticamente. Foi observado correlação entre desajuste e tensão em ambos grupos. Nas duas situações simuladas, a tensão na região cervical foi maior que na apical / Abstract: There is concern over the importance of passivity, its mechanical and biological effects and the difficulty to obtain it. Misalignments are incorporated due to the procedures inherent in the manufacture of the metal frameworks process, from impression to casting. This becomes a biomechanical concern for generating tension in the prosthesis-implant-bone set. It proposes to analyze the stresses around the implants after being bolted with Titanium frameworks for fixed dentures on 4 implants with different marginal misfits through photoelasticity. Four external hex implants, 4.1 x 11.5 mm, were positioned on a matrix simulating an edentulous jaw and named from left to right, A, B, C and D, respectively. Tapered mini-pillars were screwed to the implants and between the pillars and frameworks were positioned spacer rings with known dimensions: For the HE300 (n=5) group there was a simulated misfit, with AD: 0 microns, 100 microns, 200 microns and 300 microns, respectively. For the just misfit HE100 (n=5) group of 100 microns in implant D, the matrix was duplicated in photoelastic resin using the framework as transfer abutment. Measurements were performed in 6 points in each implant, with the single screw test and an optical microscope to measure the real mismatch obtained. For the standardized photoelastic images, infrastructure was bolted to the columns and analyzed at circular polariscope. The maximum shear stress (kgf) was measured at 7 points around each implant and compared as joint stresses in all implants around each implant, cervical and apical region. Data were tabulated and submitted to statistical analysis by Student's t-test, to evaluate the difference between the means of misfit and tension, and the Spearman correlation test to verify the relationship between stress and maladjustment. The average misfit observed was 56.96 (±13.23) microns for the HE100 group, and 194.53 (±162.98) microns for HE300, with differences between groups. Regarding the strain, the HE300 and HE100 groups were statistically equal (p = 0291). Yet there was a positive correlation between misfit and strain into HE100 and HE300. The B, C and D implants presented a higher tension in the HE100 group (p <0.0001) and HE300 group difference was not observed between the implants. Tensions were higher in the cervical than in the apical region in both groups, for HE100: 36.92 (±9.33) and 17.78 (±4.09) kgf in the cervical region, and in the apical region; for HE300: 50.37 (±13.20) kgf in the cervical region, and the apical region 21.20 (±3.95) Kgf. The HE300 group exhibited significantly more tension the cervical region (p = 0.012). It is concluded that the misfit obtained in HE300 was higher than the misfit group HE100 and generated increased tension in the cervical region. However, the analysis of the photoelastic model found tensions to be equal. A direct relationship between misfit and tension was observed in both groups. In both cases simulated, the tension in the cervical region was larger than in the apical / Doutorado / Protese Dental / Doutora em Clínica Odontológica
|
47 |
Analysis of factors that affect implant-supported prostheses in maxillary edentulous patientsMartin, Ruben 15 June 2023 (has links)
This study evaluated the survival rates of dental implants and prostheses in patients with maxillary edentulism using both randomized controlled trials (RCT) and prospective studies. The follow-up time for the selected articles ranged from 5 to 15 years. The implant survival rates ranged from 51% to 100% in RCT studies and 72% to 99% in prospective studies. Prostheses survival rates ranged from 78% to 100% in prospective studies, while RCT studies reported rates between 91% to 100%. Marginal bone loss rates ranged from 0.5mm to 2.45mm in RCT studies and 0.23mm to 1.39mm in prospective studies. This study suggests that the number and location of implants, need for sinus lift, and the type of opposing dentition can impact implant and prosthesis survival rates. Overall, this study provides valuable insights for clinicians in the management of maxillary edentulism using implant-supported prostheses.
|
48 |
Análise biomecânica da aderência de diferentes sistemas adesivos ao estrato córneo queratinizado do bico de tucanos-toco (Ramphastos toco) / Biomechanical analysis of the adherence of different adhesive systems to the keratinized horny stratum of toucan beak (Ramphastos toco)Fecchio, Roberto Silveira 07 February 2011 (has links)
Objetivou-se estudar a relação biomecânica da aderência de sistemas adesivos sobre o estrato córneo do bico de tucanos-toco (Ramphastos toco), por meio de nove diferentes tipos de adesivos, em áreas pré-estabelecidas de 16,0 mm. Cada sistema foi biomecanicamente testado três vezes, totalizando 27 ensaios biomecânicos. Os ensaios consistiram na análise das forças perpendiculares necessárias para descolar os variados tipos de resina. Após cada ensaio biomecânico, a superfície dos bicos era avaliada em microscopia eletrônica de varredura (MEV), que permitiu mensurar a quantidade de resina remanescente e o eventual rompimento das camadas superficiais de queratina. Os resultados obtidos até a completa ruptura da amostra foram, em média: 2,48 N com o uso de cimento resinoso; 23, 80 N com o uso de cianocrilato cirúrgico; 26,17 N com o uso de prime e bond fotoativado combinado com cimento resinoso; 48,75 N com o uso de resina composta nanoparticulada; 53,86 N com o uso de metil-metacrilato; 55,56 N com o uso de prime e bond fotoativado combinado com resina composta nanoparticulada; 61,11 N com o uso combinado de cianocrilato cirúrgico e metil-metacrilato; 104, 21 N com o uso de prime e bond quimicamente ativado combinado com resina composta nanoparticulada; e 110,48 N com o uso de prime e bond quimicamente ativado combinado com cimento resinoso. Estes últimos, estatisticamente mais eficientes. Microscopicamente observou-se que o uso de prime e bond quimicamente ativado combinado com resina composta nanoparticulada e com o uso de prime e bond quimicamente ativado combinado com cimento resinoso, apontou efetiva aderência a ponto de extrair as camadas superficiais das camadas de queratina após os ensaios, cuja maior aderência atribuiu-se à micro-retentividade do material adesivo às camadas de queratina, obtida pelo uso de primer e bond quimicamente ativados. Concluí-se que os sistemas de prime e bond quimicamente ativado combinado com resina composta nanoparticulada e cimento resinoso apresentam melhor propriedades de aderência e, portanto, indicação clínico-cirúrgica na confecção de próteses e no reparo de bicos de tucano-toco (Ramphastos toco). / The objective was to study the biomechanics of the adherence of adhesive systems to the horny stratum of the toucan beak (Ramphastos toco). Nine different types of adhesives were used, in pre-established areas of 16,0 mm. Each system was studied three times, totaling twenty-seven biomechanical essays. The essays consisted of the analysis of the necessary perpendicular forces to remove the adhesives. After each essay, the surface of the beaks was evaluated in electronic microscopy (MEV), which allowed to measure the amount of remaining resin and eventual breaking of the superficial layers of keratin. The results obtained until complete rupture of the sample were, on average: 2,48 N with the use of resinous cement; 23, 80 N with the use of surgical cyanocrylate; 26,17 N with the use of photoactived primer and bond combined with resinous cement; 48,75 N with the use of composite nanoresin; 53,86 N with the use of methyl-metacrylate; 55,56 N with the use of photoactived primer and bond combined with composite nanoresin; 61,11 N with the combined use of surgical cyanocrylate and methyl-metacrylate; 104, 21 N with the use of primer and bond chemically activated combined with composite nanoresin; and 110,48 N with the use primer and bond chemically activated combined with resinous cement. The microscopy evidenced that the use of primer and bond chemically activated combined with composite nanoresin and resinous cement, showed effective adherence to the point of extracting the superficial layers from the keratin layers after the essays. The largest adherence is attributed to the micro-retentivity of the adhesive material to the keratin layers, obtained by the use of primer and bond chemically activated. It was concluded that the systems of primer and bond chemically activated combined with resin and resinous cement present better properties of adherence and, therefore, clinical-surgical indication in the prostheses construction and in beak repair of toucans (Ramphastos toco).
|
49 |
"Critérios indicadores de higiene em próteses totais e fatores contribuintes da população geriátrica" / Indicating criteria of hygiene in total próteses and contributing factors of the geriatrical populationNapolitano, Fernanda Aparecida 11 July 2006 (has links)
O presente trabalho se propôs a fazer uma avaliação da higiene e saúde orais de pacientes geriátricos portadores de próteses totais. Devido ao crescimento da população idosa houve um aumento do número de pacientes que passaram a usar algum tipo de prótese (total, removível ou implantes). Espera-se que as próteses totais restituam as funções estéticas, mastigatórias e fonéticas, no entanto sua instalação não representa o final da reabilitação protética, existindo a necessidade da realização de controles periódicos. Um dos fatores essenciais para o sucesso do tratamento odontológico é a higienização eficiente, capaz de remover o biofilme das próteses. Em casos de estomatite protética associada à Cândida ssp, as medidas terapêuticas mais eficientes são os controles efetivos da higiene oral, assim como das próteses (HEARTWELL; RAHN, 1993). Partindo desse raciocínio, o índice de placa nas faces interna e externa das próteses totais maxilares foi avaliado, neste trabalho, através do uso de evidenciadores. Esse procedimento foi realizado em próteses novas tendo-se a preocupação de orientar, no momento da instalação, os portadores das mesmas sobre cuidados de higienização da cavidade oral e das próteses. Foi realizado ainda exame citológico do palato desses mesmos pacientes a fim de verificar a presença de Cândida albicans. Os resultados encontrados não mostraram diminuição dos índices de biofilme depositados nas próteses totais maxilares tanto dos pacientes do grupo experimental como dos pacientes do grupo controle, sendo que se procurou avaliar também distúrbios cognitivos. Estes resultados sugerem que o método de motivação não foi eficiente e que fatores psicológicos, sociais e culturais influenciam a motivação dos pacientes em relação a hábitos de saúde oral. / This research intended to evaluate hygiene and oral health in geriatric patients using complete dentures. Because the elderly population has increased fast much more people uses today some kind of prostheses (complete, removable or implants). Its expected that complete dentures should replace facial expression, mastigatory function and speech as well. However this is not always possible because patients are supposed to accept the inconvenience and responsibility of taking care of their own prostheses. A very important step is to perform a good hygiene intending to control biofilm development on tooth surface as well as over the prostheses. In Candida-associated denture stomatites the most important therapeutic measure is institution of effective oral and denture hygiene (HEARTWELL; RAHN, 1993). Based on what was mentioned before it was analyzed by means of staining, the biofilm index in the internal and external faces of complete dentures. Such procedures were performed in the new prostheses after instructing the patient how to clean them. It was also performed a cytologic exam of the palatal mucosa to verify if Candida albicans were present, or not. The results did not show any diminution of the biofilm index accumulate in the maxillary prostheses of both groups: control and experimental with or without deficit of cognition. Such results suggest that the motivation method was not efficient and also that psychologic, social and cultural factors do influence the patients motivation when we deal with oral health.
|
50 |
Análise biomecânica da aderência de diferentes sistemas adesivos ao estrato córneo queratinizado do bico de tucanos-toco (Ramphastos toco) / Biomechanical analysis of the adherence of different adhesive systems to the keratinized horny stratum of toucan beak (Ramphastos toco)Roberto Silveira Fecchio 07 February 2011 (has links)
Objetivou-se estudar a relação biomecânica da aderência de sistemas adesivos sobre o estrato córneo do bico de tucanos-toco (Ramphastos toco), por meio de nove diferentes tipos de adesivos, em áreas pré-estabelecidas de 16,0 mm. Cada sistema foi biomecanicamente testado três vezes, totalizando 27 ensaios biomecânicos. Os ensaios consistiram na análise das forças perpendiculares necessárias para descolar os variados tipos de resina. Após cada ensaio biomecânico, a superfície dos bicos era avaliada em microscopia eletrônica de varredura (MEV), que permitiu mensurar a quantidade de resina remanescente e o eventual rompimento das camadas superficiais de queratina. Os resultados obtidos até a completa ruptura da amostra foram, em média: 2,48 N com o uso de cimento resinoso; 23, 80 N com o uso de cianocrilato cirúrgico; 26,17 N com o uso de prime e bond fotoativado combinado com cimento resinoso; 48,75 N com o uso de resina composta nanoparticulada; 53,86 N com o uso de metil-metacrilato; 55,56 N com o uso de prime e bond fotoativado combinado com resina composta nanoparticulada; 61,11 N com o uso combinado de cianocrilato cirúrgico e metil-metacrilato; 104, 21 N com o uso de prime e bond quimicamente ativado combinado com resina composta nanoparticulada; e 110,48 N com o uso de prime e bond quimicamente ativado combinado com cimento resinoso. Estes últimos, estatisticamente mais eficientes. Microscopicamente observou-se que o uso de prime e bond quimicamente ativado combinado com resina composta nanoparticulada e com o uso de prime e bond quimicamente ativado combinado com cimento resinoso, apontou efetiva aderência a ponto de extrair as camadas superficiais das camadas de queratina após os ensaios, cuja maior aderência atribuiu-se à micro-retentividade do material adesivo às camadas de queratina, obtida pelo uso de primer e bond quimicamente ativados. Concluí-se que os sistemas de prime e bond quimicamente ativado combinado com resina composta nanoparticulada e cimento resinoso apresentam melhor propriedades de aderência e, portanto, indicação clínico-cirúrgica na confecção de próteses e no reparo de bicos de tucano-toco (Ramphastos toco). / The objective was to study the biomechanics of the adherence of adhesive systems to the horny stratum of the toucan beak (Ramphastos toco). Nine different types of adhesives were used, in pre-established areas of 16,0 mm. Each system was studied three times, totaling twenty-seven biomechanical essays. The essays consisted of the analysis of the necessary perpendicular forces to remove the adhesives. After each essay, the surface of the beaks was evaluated in electronic microscopy (MEV), which allowed to measure the amount of remaining resin and eventual breaking of the superficial layers of keratin. The results obtained until complete rupture of the sample were, on average: 2,48 N with the use of resinous cement; 23, 80 N with the use of surgical cyanocrylate; 26,17 N with the use of photoactived primer and bond combined with resinous cement; 48,75 N with the use of composite nanoresin; 53,86 N with the use of methyl-metacrylate; 55,56 N with the use of photoactived primer and bond combined with composite nanoresin; 61,11 N with the combined use of surgical cyanocrylate and methyl-metacrylate; 104, 21 N with the use of primer and bond chemically activated combined with composite nanoresin; and 110,48 N with the use primer and bond chemically activated combined with resinous cement. The microscopy evidenced that the use of primer and bond chemically activated combined with composite nanoresin and resinous cement, showed effective adherence to the point of extracting the superficial layers from the keratin layers after the essays. The largest adherence is attributed to the micro-retentivity of the adhesive material to the keratin layers, obtained by the use of primer and bond chemically activated. It was concluded that the systems of primer and bond chemically activated combined with resin and resinous cement present better properties of adherence and, therefore, clinical-surgical indication in the prostheses construction and in beak repair of toucans (Ramphastos toco).
|
Page generated in 0.0945 seconds