21

Jämförelse av spirometrivariabler observerad på Jaeger MasterScreen PFT och COPD-6 mätare / Comparison of spirometry variables observed on Jaeger MasterScreen PFT and COPD-6 Screener

Farhaan, Hafso January 2021 (has links)
Introduktion: Spirometri är en av de vanligaste undersökningsmetoderna som utförs vid bedömning av lungfunktion. Vid en dynamisk spirometri mäts lungvolymsförändringar över tid vid detektion av obstruktiva lungsjukdom. Syftet med denna studie var att validera en konventionell spirometriutrustning, Jaeger MasterScreen PFT(Carefusion, Hoechburg, Tyskland), med en ny handhållen utrustning, COPD-6 mätare (Vitalograph COPD-6 400, Ennis, Irland), för att undersöka om det fanns statistisk signifikanta skillnader på mätresultatet mellan dessa två utrustningar.  Metod och material: 22 lungfriska testpersoner mellan åldrarna 20–33 år varav 17 kvinnor och 5 män deltog i denna studie som utfördes vid Örebro universitet. De spirometrivariabler som undersöktes för Jaegerutrustningen var den forcerade exspiratoriska volymen under första sekunden (FEV1), den forcerade vitalkapaciteten (FVC) samt hur stor andel av hela lungvolymen som en person kan andas ut på första sekunden (FEV1/FVC). Med COPD-6 mätaren mättes FEV1, den forcerade exspiratoriska volymen under sex sekunder (FEV6), samt kvoten av dessa (FEV1/FEV6). För att undersöka om det förelåg en statistisk signifikant skillnad användes ett parat t-test med signifikansnivån α=0,05. Resultat: Resultatet från denna studie visade att det förelåg en statistik signifikant skillnad mellan Jaeger MasterScreen PFT och COPD-6 mätaren med p <0,05 för samtliga undersökta variabler. Bland-Altmananalysen visade en spridning inom konfidensintervallet hos samtliga variabler. Slutsats: I denna studie påvisades en statisk signifikant skillnad mellan utrustningarna där COPD-6 mätare visade lägre mätresultat än Jaegerutrustningen för variablerna FEV1 samt FEV6 alternative FVC. Dock kan inte resultatet från denna studie vara representativt för en större population då endast ett få observationer gjordes. / Introduction: Spirometry is one of the most common examination methods performed when assessing lung function. In dynamic spirometry, changes in lung volume are measured over time for the detection of obstructive pulmonary disease. The purpose of this study was to validate a conventional spirometry equipment, Jaeger MasterScreen PFT(Carefusion, Hoechburg, Germany), with a new handheld equipment, COPD-6 screener (Vitalograph COPD-6 400, Ennis, Irland), to investigate whether there were statistically significant differences in the measurement result between these two equipments. Method and material: 22 lung-healthy test subjects between the ages of 20–33 years of whom 17 women and 5 men, participated in this study, which was conducted at Örebro University. The spirometry variables examined for Jaeger equipment were the forced expiratory volume during the first second (FEV1), the forced vital capacity (FVC) and the percentage of total lung volume that a person can exhale at the first second (FEV1 / FVC). With the COPD-6 screener FEV1, forced expiratory volume for six seconds (FEV6), and the ratio of these (FEV1 / FEV6) were measured. To investigate whether there was a statistically significant difference, a paired t-test with the significance level α = 0.05 was used. Results: The results from this study showed that there was a statistically significant difference between the Jaeger MasterScreen PFT and the COPD-6 screener with p <0.05 for all variables examined. The Bland-Altman analysis showed a spread within the confidence interval for all variables. Conclusion: In this study, a statically significant difference was demonstrated between the equipments where COPD-6 screener showed lower measurement results than the Jaeger equipments for the variables FEV1 and FEV6 alternative FVC. However, the results from this study cannot be representative of a larger population as only a few observations were made.