• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 17
  • 14
  • 10
  • 5
  • 4
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 159
  • 63
  • 58
  • 54
  • 53
  • 52
  • 33
  • 32
  • 31
  • 25
  • 22
  • 19
  • 17
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Obtencao de oscilacao em frequencia unica em lasers de estado solido bombeados por diodo-laser

MATOS, PAULO S.F. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:50Z (GMT). No. of bitstreams: 1 07170.pdf: 3547961 bytes, checksum: 2b5adb1189f6eaea8048d92f88627ed4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
42

Laser de Nd:YVOsub(4) bombeado transversalmente em configuração com ângulo rasante interno

CAMARGO, FABIOLA de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:17Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:03/10164-9
43

Magnétomètres à pompage optique à Hélium 4 : développement et preuve de concept en magnétocardiographie et en magnétoencéphalographie / Helium 4 optically-pumped magnetometers : development and proof of concept in magnetocardiography and magnetoecephalography

Corsi, Marie-Constance 12 October 2015 (has links)
La magnétocardiographie (MCG) et la magnétoencéphalographie (MEG) sont deux techniques d'imagerie non-invasives mesurant respectivement les champs magnétiques cardiaques et cérébraux. Les dispositifs actuels utilisent des capteurs supraconducteurs de haute performance mais nécessitant un dispositif de refroidissement cryogénique, engendrant de fortes contraintes tant techniques que financières. Les magnétomètres à pompage optique (OPM) tendent à constituer une réelle alternative. Parmi eux figurent ceux développés au CEA-LETI, basés sur l'utilisation de l'hélium 4. Cette thèse a pour objectif de développer des magnétomètres vectoriels à 4He (fonctionnant à température ambiante) dédiés aux applications MCG et MEG.Après une optimisation des paramètres-clés d'un prototype non-miniaturisé préexistant, une sensibilité inférieure à 100 fT/sqrt(Hz) a pu être obtenue suivant deux axes. Afin de respecter les besoins spécifiques de la MCG et de la MEG une étape de miniaturisation a dû être menée et une architecture gradient-métrique a été mise en place. Parallèlement, des tests précliniques menés à Clinatec nous ont permis de concevoir un nouveau conditionnement du prototype, ainsi qu'un système réduisant les perturbations magnétiques. Une analyse des principales sources de bruit a révélé que les deux principaux contributeurs au bruit sont le laser et le système de décharge HF. Nous avons ainsi envisagé plusieurs pistes d'amélioration du niveau de bruit dont une nouvelle technique de détection. Le prototype issu de ces travaux comporte une pièce élémentaire (la cellule) d'un centimètre de côté, et présente une sensibilité intrinsèque de 350 fT/sqrt(Hz).Le dispositif a ensuite été testé avec succès dans le cadre de mesures MCG sur un sujet sain, précédées de tests sur fantôme ayant permis de prouver l'opérabilité de nos capteurs dans un environnement clinique. Par ailleurs, la reproductibilité des résultats ainsi que la possibilité de réduire à 30 s le temps d'acquisition des données ont pu être démontrées. Une optimisation spécifique de la partie optique du prototype a permis d'obtenir une sensibilité de l'ordre de 210 fT/sqrt(Hz) entre 3 et 300 Hz, compatible avec l'application MEG. Après des tests menés avec succès sur fantôme, trois séries d'essais ont été réalisées sur un sujet sain. Nous avons pu ainsi détecter des potentiels évoqués auditifs, visuels ainsi qu'une modulation de l'activité cérébrale spontanée sous l'effet de l'ouverture des paupières. L'ensemble des résultats obtenus constitue les premières preuves de concept cliniques du dispositif en MCG et MEG. / Magnetocardiography (MCG) and magnetoencephalography (MEG) are non-invasive techniques consisting in measuring respectively cardiac and brain magnetic fields. Despite their performance, the sensors currently used need a cryogenic cooling system which engenders technical and financial constraints. New cryogenic-free sensors have recently emerged: the OPMs (Optically-Pumped Magnetometers). Among them, vector 4He magnetometers developed by CEA-LETI which work at room-temperature. This thesis is focused on the development of 4He magnetometers dedicated to MCG and MEG.After having optimized the key-parameters of a first non-miniaturized prototype, a sensitivity inferior to 100 fT/sqrt(Hz) has been obtained along two axes. In order to meet biomedical constraints, a miniaturization of the device has been processed. In parallel, preclinical tests were carried out which have enabled us to design a gradiometer mode, a new packaging, and a magnetically isolated system. A noise analysis revealed that laser and HF discharge were the main sources of disturbance, and lead us to consider improvements such as a new detection mode. Eventually, a sensor, with a 1cm-sided cell, and an intrinsic sensitivity of 350 fT/√Hz has been developed.Then, device has been successfully tested in the frame of the MCG application from a healthy subject, preceded by a simulation study with a phantom which enables us to demonstrate its operability within a clinical environment. Moreover, we have proved the reproducibility of the measurements and the possibility to detect the main features of the cardiac cycle within a 30 s recording time. A specific optimization of the optical part has enabled us to obtain a 210 fT/sqrt(Hz) sensitivity between 3 and 300 Hz, suitable for the MEG application. After having tested our device with a phantom, three MEG experiments were performed with a healthy subject: auditory evoked field, visual evoked field and spontaneous activities have been detected. The obtained results form the first clinical proof of concept of the device for MCG and MEG applications.
44

Engineering the Implementation of Pumped Hydro Energy Storage in the Arizona Power Grid

January 2014 (has links)
abstract: This thesis addresses the issue of making an economic case for bulk energy storage in the Arizona bulk power system. Pumped hydro energy storage (PHES) is used in this study. Bulk energy storage has often been suggested for large scale electric power systems in order to levelize load (store energy when it is inexpensive [energy demand is low] and discharge energy when it is expensive [energy demand is high]). It also has the potential to provide opportunities to avoid transmission and generation expansion, and provide for generation reserve margins. As the level of renewable energy resources increases, the uncertainty and variability of wind and solar resources may be improved by bulk energy storage technologies. For this study, the MATLab software platform is used, a mathematical based modeling language, optimization solvers (specifically Gurobi), and a power flow solver (PowerWorld) are used to simulate an economic dispatch problem that includes energy storage and transmission losses. A program is created which utilizes quadratic programming to analyze various cases using a 2010 summer peak load from the Arizona portion of the Western Electricity Coordinating Council (WECC) system. Actual data from industry are used in this test bed. In this thesis, the full capabilities of Gurobi are not utilized (e.g., integer variables, binary variables). However, the formulation shown here does create a platform such that future, more sophisticated modeling may readily be incorporated. The developed software is used to assess the Arizona test bed with a low level of energy storage to study how the storage power limit effects several optimization outputs such as the system wide operating costs. Large levels of energy storage are then added to see how high level energy storage affects peak shaving, load factor, and other system applications. Finally, various constraint relaxations are made to analyze why the applications tested eventually approach a constant value. This research illustrates the use of energy storage which helps minimize the system wide generator operating cost by "shaving" energy off of the peak demand. The thesis builds on the work of another recent researcher with the objectives of strengthening the assumptions used, checking the solutions obtained, utilizing higher level simulation languages to affirm results, and expanding the results and conclusions. One important point not fully discussed in the present thesis is the impact of efficiency in the pumped hydro cycle. The efficiency of the cycle for modern units is estimated at higher than 90%. Inclusion of pumped hydro losses is relegated to future work. / Dissertation/Thesis / Masters Thesis Electrical Engineering 2014
45

Let Wind Rise – Harnessing Bulk Energy Storage under Increasing Renewable Penetration Levels

January 2016 (has links)
abstract: With growing concern regarding environmental issues and the need for a more sustainable grid, power systems have seen a fast expansion of renewable resources in the last decade. The uncertainty and variability of renewable resources has posed new challenges on system operators. Due to its energy-shifting and fast-ramping capabilities, energy storage (ES) has been considered as an attractive solution to alleviate the increased renewable uncertainty and variability. In this dissertation, stochastic optimization is utilized to evaluate the benefit of bulk energy storage to facilitate the integration of high levels of renewable resources in transmission systems. A cost-benefit analysis is performed to study the cost-effectiveness of energy storage. A two-step approach is developed to analyze the effectiveness of using energy storage to provide ancillary services. Results show that as renewable penetrations increase, energy storage can effectively compensate for the variability and uncertainty in renewable energy and has increasing benefits to the system. With increased renewable penetrations, enhanced dispatch models are needed to efficiently operate energy storage. As existing approaches do not fully utilize the flexibility of energy storage, two approaches are developed in this dissertation to improve the operational strategy of energy storage. The first approach is developed using stochastic programming techniques. A stochastic unit commitment (UC) is solved to obtain schedules for energy storage with different renewable scenarios. Operating policies are then constructed using the solutions from the stochastic UC to efficiently operate energy storage across multiple time periods. The second approach is a policy function approach. By incorporating an offline analysis stage prior to the actual operating stage, the patterns between the system operating conditions and the optimal actions for energy storage are identified using a data mining model. The obtained data mining model is then used in real-time to provide enhancement to a deterministic economic dispatch model and improve the utilization of energy storage. Results show that the policy function approach outperforms a traditional approach where a schedule determined and fixed at a prior look-ahead stage is used. The policy function approach is also shown to have minimal added computational difficulty to the real-time market. / Dissertation/Thesis / Doctoral Dissertation Engineering 2016
46

Estudo dos mecanismos de geracao de pulsos ultracurtos em lasers de neodimio com bombeamento continuo longitudinal

MALDONADO, EDISON P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:47Z (GMT). No. of bitstreams: 1 02749.pdf: 9285161 bytes, checksum: dfb17ccf35fc0cce66c71d0904ccb146 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
47

Avaliação da microdureza superficial do esmalte dentário irradiado com laser de diodo 960nm

RATTICHIERI, FRANCO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:33Z (GMT). No. of bitstreams: 1 11312.pdf: 3304396 bytes, checksum: 020971c2a80942aca2e60247fc8e4e74 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
48

Laser de Nd:YLF bombeado lateralmente

CORREA, VALDER O. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:32Z (GMT). No. of bitstreams: 1 11317.pdf: 3423206 bytes, checksum: bf89075f85fedad2515b1bf4995078c2 (MD5) / Dissertacao (Mestrado) / IPEN/D / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
49

Lasers de frequencia unica de Nd:YLF e Nd:YVO4 na regiao do vermelho / Single frequency Nd:YLF and Nd:YVO4 laser in the red emission

CAMARGO, FABIOLA de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:48Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
50

Interferometria speckle com lasers de diodo multimodo para análise de materiais e dispositivo / Speckle interforometry with multimode diode lasers for analisis of materials and devices

SILVA, DANILO M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:39Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0291 seconds