• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 10
  • 8
  • Tagged with
  • 29
  • 26
  • 16
  • 12
  • 9
  • 9
  • 9
  • 6
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The use of aerosol-based detection systems in the quality control of drug substances / Die Verwendung von aerosol-basierten Detektionssystemen in der Qualitätskontrolle von Arneiwirkstoffen

Almeling, Stefan January 2011 (has links) (PDF)
The work presented in this thesis was mainly targeted at exploring the capabilities of evaporation based LC detectors as well as further alternatives for the control of impurities in substances not exhibiting a suitable chromophore for UV-detection. In the course of the work carried out, several new methods for the identification, impurities control and composition testing of APIs were elaborated. An evaporation based detector that entered into the field of pharmaceutical analysis in the recent years was the Evaporative Light Scattering Detector (ELSD). However, non-reproducible spikes were reported when injecting concentrated test solutions as they are usually required for the control of impurities. The reasons, for the appearance of these spikes as well as possibilities for their avoidance were explored in a systematic study. Moreover, the dependence of the detector sensitivity on different eluent composition, eluent flow-rate and ELSD settings was investigated. In the course of the revision of the Ph.Eur. monographs for aspartic acid and alanine, a C18 reversed phase ion-pair LC method using 1 mmol/L of perfluoroheptanoic acid as an ion-pair reagent and a charged aerosol detector (CAD) was developed and fully validated for the purity control of Asp. The method was capable of separating the organic acids and major amino acids known to occur as process related impurities. With a slight modification, the method was also applicable for the purity control of Ala. Based on the developed LC-CAD method for the impurity control of alanine, a comparative study of the performance characteristics of different evaporation based LC detectors, i.e. ELSD, CAD and the recently developed Nano Quantity Analyte Detector (NQAD) was carried out. Additionally, an MS detector and qNMR were included in this study. It was found that the control of impurities in Alanine at an ICH conform level could be ensured using LC coupled to CAD, MSD and NQAD detection as well as by the use of qNMR. In terms of performance, prize and ease of use CAD and NQAD were found to be the most suitable alternatives. In terms of repeatability and sensitivity, the CAD appeared slightly superior to the NQAD. The quality of streptomycin sulfate is not sufficiently controlled by the current Ph.Eur. monograph in that an appropriate test for the control of the related substances is missing. A study was carried out to develop a C18 reversed phase ion-pair LC method using pentafluoropropionic acid as an ion-pair reagent and a CAD for the identification and control of the related substances. The developed method allowed the separation of 21 impurities from streptomycin. Moreover, coupling of the method to MS allowed the identification of the separated impurities. The method was shown to be sufficiently sensitive to control the related substances with a disregard limit of 0.1% as it is normally applied in the Ph.Eur. for products derived from fermentation. Currently, the aescin content of horse-chestnut standardized dry extract is determined using a complex and laborious photometric determination. A more selective LC-UV assay determination for beta-aescin has been proposed for the Ph.Eur. draft monograph of horse-chestnut standardized dry extract. Possibilities were explored to further improve the LC-method using detection by CAD. It was demonstrated that by the use of a modified LC-CAD method several problems related to the differences in the UV-response of the various components contained in the active aescin fraction could be eliminated. Moreover the proposed reference standard strategy was reviewed. Eventually, it was demonstrated on the example of two different clusters of pharmacologically active peptides how low energy collision induced dissociation mass spectrometry (low energy CID-MS) can successfully be used for identification testing in pharmacopoeial monographs. In this respect, the combination of a direct confirmation of the molecular mass via the m/z-ratio of the molecule ions with structural sequence information obtained by low energy CID-MS experiments was found to deliver a higher degree of certainty of the identity of a given substance than the set of tests currently described in the monographs. A significant gain in efficiency and throughput and important reduction of the amount of sample consumed during testing were identified as being additional advantages of this approach. Taken together, it could be demonstrated on various examples how recent technological advancements in the field of analytical chemistry can contribute to improve the quality control of APIs. / Die durchgeführten Arbeiten hatten zum Ziel, das Potential von evaporationsbasierten HPLC-Detektoren sowie weiterer moderner Techniken hinsichtlich ihrer Eignung zur Reinheitsprüfung von pharmazeutischen Wirkstoffen zu untersuchen. Im Zuge der Arbeiten wurden verschiedene neue Methoden zur Identifizierung, Verunreinigungskontrolle und zur Überprüfung der Zusammensetzung von pharmazeutischen Wirkstoffen entwickelt. Ein evaporationsbasierter Detektor, der in den letzten Jahren Einzug in die pharmazeutische Analytik gehalten hat, ist der Lichtstreudetektor (ELSD). Allerdings wurde berichtet, dass es im Zusammenhang mit der Injektion konzentrierter Testlösungen zum Auftreten nicht reproduzierbarer Spikes kam. In einer systematischen Studie wurden die Gründe hierfür ermittelt und gleichzeitig Möglichkeiten ihrer Vermeidung aufgezeigt. Darüber hinaus wurde die Abhängigkeit der Empfindlichkeit des Detektors von der Zusammensetzung der mobilen Phase, der LC-Flußrate und den Einstellungen des ELSD untersucht. Im Zuge der Revision der Monografien für Asparaginsäure und Alanin wurde eine C18-Ionenpaar-HPLC-Methode unter Verwendung von 1 mmol/L Perfluorheptansäure und Detektion mittels eines geladenen Sprühnebeldetektors (Charged Aerosol Detector – CAD) für die Reinheitskontrolle von Asparaginsäure entwickelt und validiert. Mit Hilfe dieser Methode konnten sowohl organische Säuren als auch die wesentlichen Aminosäuren, die als prozessrelevante Verunreinigungen bekannt sind, abgetrennt werden. Nach geringfügiger Modifikation konnte diese Methode auch zur Reiheitskontrolle von Alanin eingesetzt werden. Basierend auf der HPLC-CAD-Methode für Alanin wurde eine vergleichende Studie der Leistungsfähigkeit verschiedener evaporationsbasierter HPLC-Detektoren durch-geführt. Untersucht wurden der ELSD, der CAD und der kürzlich entwickelte „Nano Quantity Analyte Detektor“ (NQAD). Weiterhin wurden ein massenspektrometrischer Detektor (MSD) sowie die Quantifizierung mittels NMR-Spektroskopie (qNMR) in die Untersuchung einbezogen. Im Ergebnis war die Reinheitskontrolle von Alanin auf einem ICH konformen Niveau unter Verwendung des CAD, NQAD und MSD sowie mittels qNMR möglich. Hinsichtlich der Kriterien Leistungsfähigkeit, Preis und Benutzerfreundlichkeit waren der CAD und der NQAD die geeignetsten Alternativen. Bezüglich Wiederholbarkeit und Empfindlichkeit war der CAD dem NQAD leicht überlegen. Die Qualität von Streptomycinsulfat wird von der aktuellen Arzneibuchmonografie mangels eines geeigneten Reinheitstests nicht ausreichend kontrolliert. Aus diesem Grund wurde eine C18-Ionenpaar-HPLC-Methode unter Verwendung von Perfluorpropionsäure und Detektion mittels CAD zur Identifizierung und Kontrolle der Verunreinigungen entwickelt. Mit dieser Methode konnten 21 Verunreinigungen von Streptomycin abgetrennt und nach massenspektormetrischer Kopplung identifiziert werden. Die Methode erwies sich als ausreichend empfindlich, um Verunreinigungen mit einer Ausschlussgrenze von 0.1%, wie sie im Europäischen Arzneibuch für Fermentationsprodukte üblicherweise angewandt wird, zu kontrollieren. Derzeit wird der Aescingehalt in standardisiertem Rosskastanien-Trockenextrakt mittels einer komplexen photometrischen Methode bestimmt. Für den entsprechen-den Entwurf einer Monografie des Europäischen Arzneibuchs wurde eine selektivere HPLC-UV-Methode vorgeschlagen. Die Möglichkeiten einer weiteren Verbesserung dieser Methode unter Verwendung des CAD wurden untersucht. Es konnte gezeigt werden, dass eine modifizierte HPLC-CAD-Methode geeignet ist, Probleme, die sich aus der unterschiedlichen UV-Absorption der im Aescingemisch enthaltenen Substanzen ergeben, zu eliminieren. Weiterhin wurde die vorgeschlagene Referenzstandard Strategie überprüft. Abschließend wurde am Beispiel von zwei Gruppen pharmakologisch wirksamer Peptide nachgewiesen, wie kollisionsinduzierte Massenspektrometrie (CID-MS) erfolgreich für die Identitätskontrolle in Arzneibuchmongrafien eingesetzt werden kann. Diesbezüglich erbrachte die Kombination der direkten Massenbestätigung mittels des m/z-Verhältnisses des Molekül-Ions mit den aus dem CID-MS-Experiment erhaltenen Informationen ein höheres Maß an Gewissheit hinsichtlich der Identitätsbestätigung als die derzeit beschriebenen Tests. Als weitere Vorteile dieses Ansatzes wurden ein wesentlicher Effizienzgewinn sowie eine erhebliche Reduktion des durch die Testung verbrauchten Probenmaterials identifiziert. Zusammenfassend zeigen die Arbeiten an verschiedenen Beispielen, wie aktuelle Entwicklungen im Bereich der analytischen Chemie dazu beitragen können, die Qualitätskontrolle von Arzneimittelwirkstoffen zu verbessern.
2

Quantifizierung von Aminosäuren in Infusionslösungen mittels Hochleistungsflüssigkeitschromatographie-(Tandem) - Massenspektrometrie(HPLC-[MS/]MS) Methodenentwicklung und Validierung / Quantitation of amino acids in infusion solutions by high performance liquid chromatography - (tandem) - mass spectrometry (HPLC-[MS/MS]) - method development and validation

Freitag, Claudia January 2011 (has links) (PDF)
Das Ziel vorliegender Arbeit war die Entwicklung einer HPLC-MS(/MS)-Methode, die im Rahmen der pharmazeutischen Qualitätskontrolle zur direkten Quantifizierung von Aminosäuren (AS) in Infusionslösungen angewendet werden kann. Die Zielset-zung schloss eine Validierung innerhalb der für die Zweckbestimmung vorgesehenen Grenzen ein. Im Rahmen der Methodenentwicklung wurde das ESI-MS/MS-Fragmentierungs-muster von 21 Aminosäuren, von 20 stabil-isotopenmarkierten Aminosäuren, die als interne Standards verwendet wurden, sowie von einigen weiteren Substanzen bestimmt. Nach Kenntnis von Precursor- und Produktionen erstellte man eine SRM-Methode zur spezifischen MS/MS-Analyse. Dabei wurden durch das jeweilige Frag-mentierungsmuster bedingte Interferenzen bei den zu untersuchenden Aminosäuren bestimmt, die bei der zu erarbeitenden HPLC-MS-Methode beachtet werden mussten. Die Methodenentwicklung zur HPLC-MS-Analytik von underivatisierten AS umfasste mit der RP-HPLC unter Verwendung eines Ionenpaarreagenzes (IP) und der hydrophilen Interaktionschromatographie (HILIC) zwei verschiedene chromatographi-sche Ansätze. Bei der Anwendung der RP-HPLC ergaben sich Probleme. Die Verwendung eines IP, im vorliegenden Fall TDFHA (Tridecafluorheptansäure), führte zu langen Equilibrierungs-, Re-Equilibrierungs- und Spülzeiten und damit bei zwar relativ kurzer HPLC-Laufzeit zu einem aber insgesamt hohen Zeitaufwand. Gleich-zeitig war die LC-MS-Anlage auf diese Anwendung fixiert, da das Ionenpaarreagenz das Gerät stark verschmutzte und dadurch andere Analysen erheblich störte. Zudem waren die Retentionszeiten der Analyten trotz langer Equilibrierungszeiten schlecht reproduzierbar, so dass eine solche Methode im Rahmen der pharmazeutischen Qualitätskontrolle schwer validierbar wäre. Weiterführende Untersuchungen erfolgten daher nicht. In nachfolgenden Studien mit der HILIC wurden verschiedene Einflussparameter (Anteil organischer Phase im Fließmittel, pH-Wert des Fließmittels, Temperatur der Säule, Pufferkonzentration im Fließmittel, Gradientenelution) auf die Trennung der AS an einer ZIC®-HILIC-Säule untersucht. Durch Optimierung der Parameter wurde so eine HILIC-HPLC-Methode entwickelt, bei der 21 AS und 20 ihrer isotopen-markierten Referenz-AS innerhalb von 20 min eluierten. Diejenigen AS, bei denen im Rahmen der Fragmentierungsstudien Interferenzen aufgrund gleicher bzw. ähnlicher Massen der Precursor- bzw. Produktionen aufgetreten waren, wurden chroma-tographisch getrennt. Gleichzeitig hat sich die SIM-Analyse als anwendbar erwiesen. Die Anwendung des spezifischeren SRM-Modus und damit der Tandem-Massenspektrometrie war nicht erforderlich. Im Rahmen der nachfolgenden Studien zur Validierung ergab sich, dass die entwickelte Methode über einen weiten Bereich eine lineare Abhängigkeit zwischen Konzentrations- und Messwerten zeigte. Für drei der 21 AS (NAcCys, NAcTyr, Pro) wurde die quadratische Regression mit dem Anpassungstest nach Mandel als geeig-neteres Regressionsmodell ermittelt. Bei Untersuchungen zur Wiederfindung wurde ein Einfluss der Matrix-Lösung der Infusionslösung festgestellt, der zu Abweichungen hinsichtlich des Quotienten AreaAS / AreaIS führte, so dass eine Quantifizierung innerhalb der geforderten Grenzen bei Kalibrierung über reine Standardlösungen nicht möglich war. Die Validierung wurde daher nachfolgend in der Matrixlösung durchgeführt. Dabei wurde gezeigt, dass mit der entwickelten HILIC-HPLC-MS-Methode Aminosäuren in Infusionslösungen mit hoher Präzision und Richtigkeit bestimmt werden können. Neun der 21 untersuchten AS konnten im Bereich von 30% - 350%, zehn weitere im Bereich von 50% - 350% innerhalb der zur Gehaltsbestimmung von pharmazeutischen Formulierungen vorgeschriebenen Grenzen (Wiederfindung Einzelbestimmung: 98% -102.0%, Mittelwert einer Dreifachbestimmung: 98.5% – 101.5%) quantifiziert werden. Für His und Phe gelang allerdings keine Quantifizierung innerhalb der Akzeptanzkriterien, wobei der Grund hierfür in weiteren Studien geklärt werden müsste. Mit der entwickelten Methode ist damit eine gleichzeitige Quantifizierung verschiedener AS-Infusionslösungsformulierungen möglich, die sich bei gleicher Matrix in der Konzentration an AS unterscheiden. Beispielsweise seien hier die Formulierungen „Aminoplasmal® E 5% / 10% /15%“ genannt, die mit der validierten Methode erfassbar sind. Die Probenvorbereitung beschränkt sich dabei auf den Zusatz der IS-Formulierung zur Infusionslösung und einen Verdünnungsschritt. Die Quanti-fizierung erfolgt über eine 5-Punkt-Kalibriergerade, die aus einer AS- und IS-Standardmischung, nach Zusatz der einfach herzustellenden Elektrolyt-Matrix, erstellt wird. Die Analysenzeit der HPLC-MS-Methode beträgt einschließlich Equilibrie-rungszeit 35 min und ist damit deutlich kürzer als die 120 min, die bei der nach wie vor zur AS-Analytik allgemein gebräuchlichen Ionenaustauschchromatographie mit Ninhydrin-Nachsäulenderivatisierung anzusetzen sind. / The aim of this study was to develop an HPLC-MS(/MS) method to be used within pharmaceutical quality control for the direct quantitation of amino acids (AS) in infusion solutions. The validation within the limits of the intended purpose was part of the objective. In the course of the method development the ESI-MS/MS fragmentation pattern of 21 amino acids, 20 stable isotope labelled amino acids, which were used as internal standards, and some further substances were determined. By knowing precursor- and product ions a SRM-method for specific MS/MS analysis was created. Interferences due to the respective fragmentation pattern within the analytes were detected, which had to be considered during the following HPLC-MS method development. The HPLC-MS method development for the analysis of underivatized AS comprised two different approaches: the RP-HPLC using an ion-pair reagent (IP) und the hydrophilic interaction chromatography (HILIC). Problems occurred using the RP-HPLC. Due to the IP, in this study TDFHA (tridecafluoroheptanoic acid), long equilibration-, re-equilibration and rinsing-times were necessary so that this method is very time consuming despite short HPLC run times. Because of the contamination with TDFHA the use of the LC-MS system was limited. Furthermore, despite long equilibration times, retention times of the analytes were poorly reproducible. A validation of the method within the requirements of the pharmaceutical quality control would be therefore hardly to perform. Thus, further studies were not carried out. The following studies were focused on HILIC. Different parameters (percentage of organic solvent in the eluent, pH of the eluent, column temperature, buffer concentration in the eluent, gradient elution) were checked concerning their effects on the separation of AS on a ZIC®-HILIC column. By optimizing the parameters, a HILIC-HPLC method was developed, by which 21 AS and 20 of their stable labelled isotopes were eluted within 20 min. All AS, which interfered with other AS due to their fragmentation pattern, were chromatographically separated. Moreover, the SIM mode was found to be suitable for the separation of AS, thus avoiding SRM mode and tandem mass spectrometry. During the validation studies the HILIC-HPLC-MS method showed linear relation between AS-concentration and measured value over a wide range. Linearity was tested with the Mandel test revealing better fit by quadratic regression for three of 21 AS (NAcCys, NAcTyr and Pro). Recovery studies showed an influence of the matrix of the infusion solution, which led to deviations in the quotients areaAS / areaIS. As a result, quantitation by calibration with pure AS standard solutions was not possible within the given limits. Thus, validation was performed with matrix solution. Thereby it was shown that with the developed HPLC-MS method AS could be deter-mined in infusion solutions with high precision and accuracy. Nine of 21 AS were quantified in the range of 30%-350%, ten AS in the range of 50%-350% within the given requirements of pharmaceutical quality control (individual recovery value: 98% -102.0%, mean recovery value (threefold determination): 98.5% – 101.5%). His and Phe could not be quantified within the acceptance criteria; the reason for this would have to be found out in further studies. With the developed method the simultaneous quantitation of different AS infusion solutions, which differ in analytes concentrations with constant matrix concentration, can be realized. For instance, the formulations „Aminoplasmal® E 5% / 10% /15%“ can be mentioned, which could be determined by using the validated method. Sample preparation is fast and simple, consisting in addition of IS-formulation to the infusion solution and a single dilution step. Quantitation is performed by external standard calibration; the 5-point-regression-line is made by analyzing AS- and IS-standard solution after adding the electrolyte matrix solution, which is easily to produce. HPLC-MS analysis time is 35 min (including equilibration time), thus considerably shorter than the approximately 120 min required with the still common AS analytical method (ion exchange chromatography with postcolumn ninhydrin derivatization).
3

Entwicklung vereinfachter flüssigchromatographischer 
Untersuchungsmethoden zur Qualitätskontrolle essentieller Antimalaria-Medikamente in Entwicklungs- und 
Schwellenländern

Höllein, Ludwig January 2015 (has links) (PDF)
Im Rahmen dieser Arbeit wurden sehr einfache, flüssigchromatographische Methoden zur Qualitätsanalytik gebräuchlicher Antimalaria-Medikamente (Amodiaquin, Mefloquin, Proguanil sowie die Kombination Artemether/Lumefantrin) entwickelt, die nur wenige, günstig erhältliche Chemikalien (Phosphatpuffer, Methanol) sowie gewöhnliche, kommerzielle RP-18-Säulen benötigen. Sie sind insbesondere zur Anwendung in Laboratorien in Entwicklungsländern geeignet und erfordern keine komplexen HPLC-Instrumente wie beispielsweise Gradientenpumpen oder Säulenthermostate. Der Verzicht auf Ionenpaarreagenzien ermöglicht es, dass eine stationäre Phase für mehr als nur einen einzigen Einsatzzweck verwendet werden kann und dass langwierige Äquilibrier- bzw. Spülschritte nicht notwendig sind. Alle Methoden arbeiten im isokratischen Elutionsmodus und durch die Verwendung kurzer Säulen (125 mm) konnten die jeweiligen Analysenzeiten zusätzlich verringert werden. Hierdurch ist zudem eine Reduzierung des Fließmittelverbrauches möglich. Während der Methodenentwicklung wurden charakteristische, aus dem Herstellungsweg des jeweiligen Arzneistoffes stammende potentielle Verunreinigungen berücksichtigt. Ihre Bestimmung erlaubt eine Aussage über die Herkunft eines Wirkstoffes bzw. eines Arzneimittels, da das Verunreinigungsmuster einer Substanz oftmals die Zuordnung zu einem bestimmten Herstellungs- bzw. Reinigungsprozess ermöglicht. Alle Methoden wurden hinsichtlich der Linearität innerhalb des Arbeitsbereiches sowie der Wiederholpräzision charakterisiert. Es wurde eine gute Reproduzierbarkeit gefunden. Die Nachweis- und Bestimmungsgrenzen der untersuchten Verunreinigungen lagen bei einem Level von je 0.1 %. Durch gezielte Variation wurde der Einfluss wechselnder Trenntemperaturen sowie schwankender pH-Werte der jeweiligen mobilen Phase und die hieraus resultierenden Effekte untersucht. Hierbei zeigte sich, dass die Methoden sehr robust gegenüber diesen Einflussgrößen sind und somit für die Anwendung mit einfach ausgestatteten HPLC-Systemen sowie besonders für den Einsatz in tropische Gebieten mit wechselnden klimatischen Bedingungen gut geeignet sind. Flüssigchromatographische Methoden spielen heute in der pharmazeutischen Analytik vor allem zur Bestimmung der Reinheit eines Arzneistoffes eine herausragende Rolle und sind in nahezu jeder Monographie der wichtigsten Arzneibücher (z. B. im Ph. Eur.) zu finden. Einfach durch-führbare Untersuchungsmethoden, wie beispielsweise die im GPHF-Minilab® angewandte Dünnschichtchromatographie, erfordern im Vergleich zur HPLC weniger komplexe und teure Instrumente und können selbst in entlegenen Gebieten ohne Laboratorium durchführt werden. Sie verfügen allerdings über eine nur sehr geringe Genauigkeit und Reproduzierbarkeit, da sowohl die praktische Durchführung als auch die anschließende Auswertung rein manuell bzw. visuell erfolgt und somit in hohem Maße einer Beeinflussung durch den jeweiligen Analytiker unterworfen ist. Die entwickelten HPLC-Methoden wurden mit dünnschichtchromatographischen Verfahren verglichen, hierbei besonders unter dem Aspekt der visuellen und der instrumentellen Auswertung der Chromatogramme zur Bestimmung des Gehaltes einer unbekannten Probe. Hierbei konnte aufgezeigt werden, dass die Dünnschichtchromatographie der Flüssigchromatographie eindeutig unterlegen ist, insbesondere wenn die Auswertung nicht mittels eines entsprechenden Scanners sondern rein visuell erfolgt: Nur in den wenigsten Fällen ist es möglich, eine annähernd präzise Aussage über den Gehalt zu treffen und zudem ist die Bestimmung der Verwandten Substanzen nur sehr bedingt möglich. Durch den Einsatz von Auftragegeräten bzw. Plattenscannern kann die Genauigkeit zwar signifikant erhöht werden, allerdings sind solche Instrumente im Verhältnis wesentlich teurer als einfache, modulare HPLC-Systeme und zählen heute in den wenigsten Laboratorien zum Standardinventar. Vereinfachte chromatographische Methoden können ein wichtiges Hilfsmittel für Kontrolllaboratorien in Entwicklungsländern sein, wenn komplexe, etablierte Protokolle nur eingeschränkt angewendet werden können. Durch die Kombination aus dünnschichtchromatographischer Basisanalytik und einer flächendeckenden Untersuchung mittels HPLC lässt sich die Arzneimittelqualität sehr gut überprüfen, die regulatorischen Organe eines Landes entsprechend zu entlasten und die Versorgung der Bevölkerung mit qualitativ einwandfreien Medikamenten zu gewährleisten. Ein weiterer Teil der Arbeit befasst sich mit der Stabilitätsanalytik individuell hergestellter, Noradrenalin-haltiger Injektionslösungen. Solche Rezepturen werden oftmals in Krankenhausapotheken im Rahmen der Defektur auf Vorrat durch Verdünnen der entsprechenden kommerzieller Fertigarzneimittel mit isotonischer Kochsalzlösung zubereitet, um z. B. für Notfallsituationen am Wochenende die Rezepturen vorrätig zu haben. Durch die Untersuchungen wurde geprüft, inwieweit der übliche Verdünnungsgrad von 0.1 % einen Einfluss auf die Stabilität des Noradrenalins hat und welche Lagerungsbedingungen für die Zubereitungen empfohlen werden können. Nach der Lagerung unter verschiedenen Bedingungen (gekühlt, bei Raumtemperatur sowie jeweils mit bzw. ohne Lichtschutz) konnte gezeigt werden, dass die Gehalte an Noradrenalin bei keiner der untersuchten Lagerungsbedingungen unter einen Wert von 99.0 % fielen. Individuell hergestellte Noradrenalin-Injektionslösungen können somit bis zu sieben Tage im Voraus hergestellt und für die Anwendung am Patienten bereit gehalten werden. Die Lösungen sollten dennoch gekühlt und unter Lichtschutz aufbewahrt werden, um den Abbau des Arzneistoffes und eine mikrobielle Kontamination zu minimieren. / This work focuses on the development of simple, liquid chromatographic methods for the quality analysis of common antimalarial medicines, i.e. amodiaquine, mefloquine, proguanil and the fix-dose combination of artemether and lumefantrine. They require a minimum of readily available, cheap chemicals (e.g. phosphate buffers or methanol) and commercially available RP-18 columns. They were designed for use in quality control laboratories in resource-restraint environments, e.g. in laboratories in the developing world, and do not require complex HPLC instrumentation which are either not available or affordable, e.g. with expensive gradient pumps or column ovens. Ion-pairing reagents were strictly avoided during method development which is a great advantage for routine application: long equilibration and flushing procedures are not necessary and a column can be used for more than one single method. An isocratic elution mode was applied and using short analytical columns (125 mm) allows reducing the analysis time and eluent consumption, respectively, to a minimum. During method development impurities being characteristic for the respective synthesis pathway(s) of the active substances were considered. Thus, determining the quality of a com-pound with regard to its content and purity is possible and distinct manufacturers or sources can be identified. Linearity and repeatability were assessed and a good reproducibility was found. Limits of detection and quantitation, respectively, were measured and the respective impurities can be determined to a level of 0.1 %. By varying the separation temperature and the pH-value of the respective mobile phases method ruggedness was investigated. A high grade of robustness towards these parameters could be confirmed, indicating that the methods are suitable for being used in tropical environments. Liquid chromatographic methods play an important role in pharmaceutical analysis today and they are widely applied for determining the purity of a compound. Respective protocols have been added to almost every monograph of the most important pharmacopoeias, e.g. the European Pharmacopoeia. Of note, those protocols may not be applied in every laboratory without limitations. Although very simple methods of analysis, e.g. thin-layer chromatography which is described in the manuals of the GPHF-Minilab®, require less expensive instruments and may even be applied in resource-restraint environments, they exhibit a poor accuracy and reproducibility. Preparing and evaluating the plates manually may strongly bias the results, and in addition this highly depends from the respective analyst who performs the tests. The comparison of thin-layer chromatographic assays applying a manual and an instrumental evaluation to results obtained from liquid chromatographic tests clearly exhibited the disadvantages particularly for determining the quality of a compound. It is almost impossible to exactly determine the content of a sample, and a comprehensive test for related substances cannot be carried out. Using application devices and plate readers may increase the accuracy, however such instruments are a lot more expensive than simple, modular HPLC systems and normally do not belong to the standard inventory of a quality control laboratory. Simplified HPLC methods may serve as helpful instruments for the regulatory infrastructure of developing countries. Combining them with basic thin-layer chromatographic tests and applying them comprehensively may enable the respective quality control laboratories to ensure the nationwide supply with immaculate medicines. In the second part of this work the stability of individually prepared dilutions of commercially available norepinephrine injectable solutions was investigated and recommendations for storage conditions were derived. In hospital pharmacies it is a common practice to prepare such solutions from proprietary products by diluting them with isotonic sodium chloride solution or other suitable buffer solutions, respectively, to a concentration of 0.01 mg/ml (1:100). This is important particularly in case of emergencies, e.g. on the weekend or during holidays, because the respective medication can be held in stock even when the pharmacy is closed. Within the framework of the experiments the influence on the stability of norepinephrine after diluting the respective proprietary product with sodium chloride solution was investigated. The samples were stored with and without refrigeration, and unprotected and protected from sunlight. The results showed that under none of the investigated storing conditions the content of norepineprhine decreased significantly. The lowest content which was found was 99.0 %. Thus, individual norepinephrine injectable solutions can be prepared in advance and storing them is possible for at least seven days. Although a degradation of the active ingredient or a diffusion in the primary packaging material (e.g. a syringe made from polyethylene) could not be observed, it is recommended to store the preparations in the refrigerator and protected from light. A microbial contamination may also be avoided like this.
4

Kapillarelektrophoretische Reinheitsanalytik verschiedener Arzneistoffe des Europäischen Arzneibuchs / Capillary electrophoretic impurity analysis of different drugs of the European Pharmacopoeia

Borst, Claudia January 2011 (has links) (PDF)
Die Kapillarelektophorese (CE), deren Trennprinzip auf der Wanderung geladener Teilchen im elektrischen Feld basiert, ist eine Methode, die in verschiedenen Techniken angewandt werden kann. Sowohl die wässrige Kapillarzonenelektrophorese (CZE) als auch die wasserfreie CE (NACE), aber auch die elektrokinetische Chromatographie mittels Mikroemulsion (MEEKC) wurden in dieser Arbeit für die Reinheitsanalytik der im Europäischen Arzneibuch beschriebenen Wirkstoffe Ethambutol, Quetiapin, Ephedrin sowie Levodopa und deren jeweils strukturverwandter Substanzen benutzt. Der Wirkstoff Ethambutol wird in der (S,S)-Form verwendet, die im Ph. Eur. 7 als Dihydrochlorid aufgeführt ist. Um eine Trennmethode für (S,S)-Ethambutol, sein Enantiomer und die achirale meso-Verbindung entwickeln zu können, wurden die beiden stereoisomeren Verunreinigungen aus 2-Amino-1-butanol und Diethyloxalat synthetisiert. Zur Trennung dieser drei Ethambutol-Isomere wurde CZE als Methode gewählt. In saurem Phosphatpuffer musste eine hohe Probenkonzentration von 1 mg/ml verwendet werden, um die Substanzen mit UV detektieren zu können (λ: 200 nm). In alkalischem Tetraboratpuffer war das Chromophor dank der freien Elektronenpaare der Stickstoff-Moleküle besser ausgeprägt und die Intensität der Peaks deutlich intensiver. Als chirale Selektoren wurden die nativen α-, β- und γ-Cyclodextine (CDs) und verschiedene derivatisierte β-CDs eingesetzt. Die Methode wurde vielfach in Bezug auf Molarität und pH-Wert der Puffer, Konzentration der verschiedenen chiralen Selektoren, Spannung und Temperatur modifiziert. Jedoch konnte keine Trennung der Stereoisomere erreicht werden. Eine CD-modifizierte MEEKC-Methode wurde herangezogen, um die Racemate der Aminosäuren Dopa, Methyldopa, Tyrosin und Phenylalanin voneinander zu trennen. Dazu wurde eine Mikroemulsion (ME) aus Ethylacetat, SDS, 1-Butanol, Phosphatpuffer, sulf. β-CD und, wenn nötig, aus dem organischen Modifier 2-Propanol eingesetzt. Für jede DL-Aminosäure wurde die Zusammensetzung der ME als auch die Geräteeinstellungen (Spannung, Temperatur) optimiert. Die Trennung von DL-Dopa konnte ohne Zugabe eines organischen Modifiers durchgeführt werden. Auf Grundlage dieser individuellen Methoden wurden zwei CD-modifizierte MEEKC-Methoden entwickelt, mit denen alle vier untersuchten Racemate getrennt werden konnten. Die abschließende Validierung in Bezug auf Wiederholpräzision (Auflösung, Migrationszeiten, Verhältnis der korrigierten Peakflächen und Anzahl der theoretischen Böden) und Detektionsgrenzen zeigte, dass die Methoden präzise Ergebnisse liefern. Die Technik der MEEKC wurde auch zur Trennung von Ephedrin-Derivaten genutzt. Wedig et al. konnten die Racemate von Ephedrin, Pseudoephedrin, N-Methylephedrin und Norephedrin mit einer HDAS-β-CD-modifizierten CZE-Methode in einem Lauf basislinientrennen, indem ein 50 mM Phosphatpuffer, pH 3,0 als HGE eingesetzt wurde. Aus diesem HGE und den organischen Bestandteilen, die zur Trennung der Aminosäuren führten, wurde eine ME hergestellt. Entgegen der Methode von Wedig et al. konnte mittels HDAS-β-CD keine zufriedenstellende Trennleistung erreicht werden. Durch Austausch des chiralen Selektors gegen sulf. β-CD und Modifizierung des Phosphatpuffers in Ionenstärke und pH-Wert konnte für alle vier Epedrin-Derivate eine Basislinientrennung erzielt werden. Diese MEEKC-Methode wurde auf weitere Ephedrin-Derivate angewandt, wodurch das racemische 2-(Dibutylamino)-1-phenyl-1-propanol partiell, die Racemate von Adrenalin, 2-Amino-1-phenylethanol und Diethylnorephedrin vollständig voneinander getrennt werden konnten. Während mit der HDAS-β-CD-modifizierten CZE-Methode alle vier Ephedrin-Derivaten in einem Lauf getrennt werden konnten, hat die MEEKC-Methode den Vorteil mit dem kostengünstigeren sulf. β-CD auszukommen. Schlussendlich wurde eine Reinheitsanalytik von Quetiapin und seinen verwandten Substanzen Quetiapindesethanol, Quetiapin-N-Oxid und Quetiapinlactam entwickelt. Da Quetiapinlactam fast ausschließlich in organischen Lösungsmitteln löslich ist, sollte eine wasserfreie CE-Methode (NACE) eingesetzt werden. Zwar konnte eine Methode entwickelt werden, deren HGE aus Methanol, Acetonitril, Ammoniumacetat und Essigsäure bestand, und mit der Quetiapin und seine drei verwandten Substanzen sehr gut getrennt werden konnten. Allerdings konnte sie aufgrund von Stromabbrüchen nicht validiert werden. Alternativ wurde eine wässrige, gut reproduzierbare CZE-Methode gefunden, deren Elektrolytlösung aus einem 80 mM Phosphatpuffer, pH 4.0 bestand. Aufgrund der Wasserunlöslichkeit von Quetiapinlactam konnten so nur Quetiapin und die Verunreinigungen Quetiapindesethanol und Quetiapin-N-Oxid erfasst werden. Abschließend wurde die CZE-Methode validiert, wodurch die hohe Präzision der ermittelten Werte gezeigt werden konnte. / The separation mechanism of capillary electrophoresis (CE) is based on the mobility of ions in an electric field. CE is a versatile technique, which can be operated in different modes. In this work, both aqueous capillary zone electrophoresis (CZE) and nonaqueous CE (NACE) and microemulsion electrokinetic chromatography (MEEKC) were investigated. Using these CE methods, impurity analysis was accomplished for serveral pharmaceuticals, which are described in the European Pharmacopoeia (Ph. Eur.): ethambutol, quetiapine, ephedrine, levodopa and correspondingly related substances. The active agent ethambutol is used in the (S,S)-configuration and in Ph. Eur. 7 the monograph describes the dichloride of the substance. In order to develop a separation method for (S,S)-ethambutol, its enantiomer and the achiral meso-compound were synthesized by the reaction of 2-amino-1-butanol and diethyloxalate. For the separation of these ethambutol compounds the CZE technique was chosen. After using an acid phosphate buffer, the concentration of the sample solution had to be set at 1 mg/ml for an sufficient UV adsorption (λ: 200 nm). After using a basic tetraborate buffer, the chromophore was more sensitive due to the electron pair of the nitrogen molecule, which led to higher peak intensity. Native α-, β- and γ-cyclodextins (CDs) and some derivatives of β-CD were added to the background electrolyte (BGE) as chiral selectors. The CZE method was modified in many ways, e. g. in molarity and pH value of the BGE, in concentration of the chiral selectors, in voltage and in temperature. In spite of various variations, the separation of the stereoisomers was not successful. A CD-modified MEEKC method was applied to separate the racemates of dopa, methyldopa, tyrosine and phenylalanine. For this purpose, a microemulsion (ME) was employed, which consisted of ethyl acetate, SDS, 1-butanol, phosphate buffer, sulf. β-CD and 2-propanol, used as an organic modifier, if necessary. For each DL-amino acid the composition of the ME and the instrument settings (voltage, temperature) were optimized. The separation of DL-dopa was accomplished without an organic modifier. Based on the methods evolved individually, two CD-modified MEEKC methods were developed to separate all four racemates. The concluding validation of these methods with respect of repeatability (resolution, migration time, ratio of the corrected peak areas, and number of theoretical plates) and limit of detection showed that the methods give precise results. The technique of MEEKC was also used for the separation of ephedrine derivatives. By means of a HDAS-β-CD-modified CZE method, Wedig et al. achieved baseline separation of racemic ephedrine, pseudoephedrine, N-methylephedrine and norephedrine in one run. In their experiment the BGE consisted of 50 mM phosphate buffer, pH 3.0. An ME was composed of this buffer as aqueous phase and the organic compounds, which formed the oil-phase of the ME for the amino acids. Contrary to the CZE method of Wedig et al., who used HDAS-β-CD, no satisfying resolution was observed. Replacing the chiral selector HDAS-β-CD with sulf. β-CD and modifying the phosphate buffer in ionic strength and pH value, led to baseline separation of the four mentioned ephedrine derivatives eventually. This MEEKC method was subjected to the separation of other ephedrine derivatives. So racemic 2-(dibutylamino)-1-phenyl-1-propanol could partly be separated, whereas complete separation could be observed for racemic adrenaline, 2-amino-1-phenylethanol and diethylnorephedrine. Whereas the MEEKC method is much cheaper by using sulf. β-CD, the application of the HDAS-modified CZE method resulted in the separation of all four racemic ephedrine alkaloids in one run. Finally, an impurity analysis of quetiapine and its related compounds quetiapine desethanol, quetiapine-N-oxide and quetiapine lactam was develop. The molecular structure of quetiapine lactam needed to be clarified, as this compound had not been described before. By using mass spectrometric (MS) as well as infrared (IR) and NMR investigations, the substance could be identified: Dibenzo[b,f][1,4]thiazepine-11(10H)one. As quetiapine lactam was found to be nearly insoluble in water and aqueous solutions, an NACE method had to be applied. Indeed, a method was developed with a BGE consisting of methanol, acetonitril, ammonium acetate and acetic acid. Thereby, the separation of quetiapine and its three mentioned impurities was observed with high resolution values. However, validation was impossible, because of numerous aborts of the current. Alternatively, an aqueous and highly reproducible CZE method was found with a BGE composed of 80 mM phosphate buffer, pH 4.0. Due to the water insolubility of quetiapine lactam, only quetiapine desethanol and quetiapine-N-oxide could be analysed as impurities. Finally, the aqueous CZE method was validated; the high precision of the results could be verified.
5

Quantitative NMR-Spektroskopie zur Reinheitsbestimmung von Arzneistoffen / Quantitative NMR spectroscopy for purity determination of active pharmaceutical ingredients

Deubner, Ralph January 2004 (has links) (PDF)
Quantitative Bestimmungen Anhand verschiedener Substanzen konnte im Rahmen dieser Arbeit gezeigt werden, dass die NMR-Spektroskopie in der Lage ist, Verunreinigungen von Arzneistoffen zu quantifizieren. Für das Antidepressivum Fluvoxamin ist im Arzneibuch eine Ionenpaarchroma-tographie vorgeschrieben, um die Verunreinigung des wirksamen E-Isomers durch das Z-Isomer zu quantifizieren. Ionenpaarchromatographischen Methoden mangelt es häufig an der Robustheit. Eine quantitative Auswertung der NMR-Spektren einer Mischung beider Isomere ist ohne aufwändige Probenvorbereitung möglich. In den 1H-NMR-Spektren der Mischung sind die Signale der Was-serstoffe beider Isomere an Position 2 gut voneinander getrennt. Werden diese quantitativ ausgewertet, dann ist es nach Optimierung insbesondere hinsichtlich der T1-Relaxationszeit möglich, den Anteil des Z-Isomers auf 0,2 % zu begrenzen. Auch für die Bestimmung der Abbauprodukte des Perphenazinenantats konnte gezeigt werden, dass die qNMR eine geeignete Methode darstellt. Perphenazine-nantat kann durch Esterhydrolyse gespalten werden. Zur Auswertung der 1H-NMR-Spektren wird der Vergleich der Integralflächen der Signale der Wasserstoffe an Position 21 des Perphenazins mit dem zusammenfallenden Signal der Wasserstoffe an Position 11 beider Substanzen herangezogen. Es konnte sowohl Perphenazin als Abbauprodukt des Esters als auch Perphena-zinenantat in Perphenazin quantifiziert werden. Zusätzlich kann der Bereich der aromatischen Wasserstoffe zu einer Aussage über die Oxidation genutzt werden. Bei der Oxidation des Schwefels im Phenothiazinring zum Sulfoxid und zum Sul-fon ändern sich die chemischen Verschiebungen der Wasserstoffkerne in diesem Ringsystem. Dadurch wird eine halbquantitative Aussage ermöglicht. Schließlich konnten die beiden Epimere Chinin und Chinidin jeweils als Verunrei-nigung des anderen Chinaalkaloides quantifiziert werden. Auch in diesem Fall lie-gen in den 1H-NMR-Spektren in DMSO-d6 von Mischungen dieser beiden Verbin-dungen Signale weit genug auseinander, um eine Quantifizierung zu ermöglichen. In beiden Fällen, der Bestimmung von Chinidin in Chinin und von Chinin in Chini-din konnte dies auf einem Niveau von 2,5% geschehen, was den Anforderungen der Arzneibücher entspricht. Gentamicinsulfat Die 1H-NMR-Spektroskopie wurde ebenfalls zur Charakterisierung der Zusam-mensetzung des Antibiotkums Gentamicin eingesetzt. Gentamicin, das fermentativ aus Micromonospora purpurea gewonnen wird, besteht aus verschiedenen Haupt- und Nebenkomponenten, deren Zusammensetzung je nach Fermentationsbedingungen schwankt. Nach einer Reihe von Todesfällen im Zusammenhang mit der Anwendung des Antibiotikums Gentamicin in den USA wurde vermutet, dass diese auf verschiede-ne Verunreinigungen zurückzuführen sind. In der aktuellen Arzneibuch-Monographie wird eine HPLC-Methode beschrieben, die zwar die Hauptkomponenten quantifizieren kann, aber nicht alle Nebenkomponenten gut abtrennt. Auch ist die gesamte Elutionszeit sehr lang, so dass spät eluierende Substanzen breite Peaks zeigen. Außerdem ist der benutzte gepulste amperometrische Detektor sehr empfindlich und die Methode insgesamt daher wenig robust. Unter Zuhilfenahme von ein- und zweidimensionalen Standardmesstechniken sowie selektiver TOCSY-Messungen konnten alle Signale in den 1H- und 13C-NMR-Spektren der Haupt- und Nebenkomponenten von Gentamicin vollständig zugeordnet werden. Dabei zeigte sich, dass der Bereich der anomeren Wasserstoffe sehr gut geeignet ist, Aussagen über die Reinheit und über das Verhältnis der Hauptkomponenten zueinander treffen zu können. In dem in der Abbildung gezeigten Ausschnitt aus einem 400 MHz-1H-NMR-Spektrum ist eine Integration der H20-Signale der Hauptkomponenten aufgrund mangelnder Trennung nicht möglich. Diese ist jedoch in 600 MHz-Spektren möglich. Auf diese Weise können die Verhältnisse der Hauptkomponenten zueinander bestimmt werden. Die so erhaltenen Ergebnisse zeigen eine sehr gute Übereinstimmung mit den aus einer MEKC-Trennung erhaltenen Daten. Das zeigt die sehr gute Ergänzung dieser beiden Methoden. Insgesamt wurden für diese Arbeit über 40 Gentamicin-Proben verschiedener Hersteller untersucht, miteinander verglichen und in verschiedene Gruppen einge-teilt. Als Leitverunreinigung hat sich dabei Sisomicin erwiesen. Daneben konnte der Vergleich der Verunreinigungsprofile Hinweise auf Handelswege geben. Unter den untersuchten Proben waren auch diejenigen, zu den Todesfällen führten. Die-se konnten den stark verunreinigten Gruppen zugeordnet werden. / Quantitative analysis It could be shown on the basis of different substances that the NMR spectroscopy is able to quantify impurities of pharmaceuticals. For the quantification of impurities of the antidepressive drug fluvoxamine the pharmacopoeia describes an ion-pair chromatographic method. Since the antide-pressive activity resides on the E-isomer the content of the Z-isomer has to be lim-ited. Since ion-pair chromatography often lacks of robustness, qNMR is an alterna-tive. The quantitative evaluation of 1H NMR spectra of a mixture of the two isomers is possible without extensive sample preparation. The signals of the hydrogens at position 2 of both isomers are well separated in the spectrum. If these are quantitative evaluated, under optimized conditions, e.g. with respect to T1-relaxation time, it is possible to limit the content of the Z-isomer to 0.2%. For analysis of degradation products of perphenazine enantate qNMR is a suitable method. Perphenazine enantate can be cleaved by ester hydrolysis. Using the integral area of the signal of the hydrogens at position 21 of per-phenazine in comparison to the integral area of the overlapping signals of the hydrogens at position 11 of both substances perphenazine and perphenazine enan-tate it was possible to quantify perphenazine as a degradation product of per-phenazine as well perphenazine enantate in perphenazine. Additionally the area of the aromatic hydrogens can be used for the analysis of the oxidation. The oxidation of the sulfur of the the phenothiazine-moiety to the sulfoxide and the sulfone changes the chemical shifts of the corresponding hydrogens. This enables a half-quantitative assessment. Finally it was possible to quantify the two epimers quinine and quinidine as an impurity in either drug. Again signals of both substances could be identified to be used for quantification. In both cases quinine as impurity of quinidine and vice versa the impurity can be limited to 2.5 per cent as required by the pharmacopeias. Gentamicin sulfate 1H-NMR spectroscopy was also used as an analytical method to characterize the composition of gentamicin. Gentamicin is produced from Micromonospora purpurea by fermentation and consists of different main and side components. The composition varies when applying different fermentation conditions. A number of deaths in connection with the application of the antibiotic drug gen-tamicin in the USA were reported. Different impurities were suspected to be re-sponsible for these deaths. In the current pharmacopoeia monograph an HPLC method is described which is able to quantify all main components but does not separate all side components. In addition, the total elution time is long. Thus late eluting substances show very broad peaks. Furthermore the used pulsed am-perometric detector is very sensitive and the method is not very robust over all. Using one- and two-dimensional routine NMR techniques and selective TOCSY experiments it was possible to assign all signals in the 1H- and 13C-NMR spectra of all main and side components. The area of the anomeric hydrogens is appropriate to evaluate the purity of gentamicin and the proportions between the main compo-nents. In the part of the 400 MHz 1H-NMR spectrum integration of the H20 signals of the main components is impossible due to the missing baseline separation. However, using 600 MHz spectra integration is possible. In this way the proportions between the main components can be determined. The results achieved in this way show good accordance to the results obtained with an MEKC separation. More than 40 gentamicin samples from different manufactures were studied, com-pared and divided into several groups, based on their impurity profile. As a lead impurity sisimocin has been identified. Besides that, the comparison of the impurity profiles enables to trace the trade ways. Some of the samples which led to the deaths were among the samples being classified in the impure groups.
6

Entwicklung einer Methode zur kontinuierlichen Qualitätskontrolle beim Nassgussformverfahren mit automatischen Formanlagen

Malaschkin, Andrej 10 July 2009 (has links) (PDF)
Im Rahmen der Arbeit wurde die neuartige Messmethode und Messeinrichtung zur Erfassung der von der Formstoffbewegung in dem Messpunkt hervorgerufenen Kräfte vorgeschlagen. Die erarbeiteten Kalibrier- und Berechnungsmethoden lassen es zu, die direkt an der Gießform während der Produktion erfassten Signale in Formdichte- und unterschiedliche Festigkeitswerte umzurechnen. Die erarbeiteten Messeinrichtungen und Berechnungsmethoden wurden sowohl durch die Laborprüfungen als auch durch den direkten Praxiseinsatz geprüft. Während dieser Prüfungen wurde festgestellt, dass die Formqualitätskennzeichen mit ausreichender Genauigkeit festgestellt werden können. Die Auswirkung der veränderlichen Formstoffzusammensetzung auf die zur Berechnung der Formqualitätskennzeichen benötigten Koeffizienten wurde ebenfalls untersucht. Abschließend wurde eine Methode zur Ermittlung „formbezogener“ und „energetischer“ Qualitätsmerkmale der Formanlagen vorgeschlagen. Die Methode lässt den Vergleich der Formmaschinen auf der Basis der erreichten Formqualität und des zum Erreichen dieser Qualität geleisteten Energieaufwandes.
7

Development of simple and cost-effective High Performance Liquid Chromatography methods for quality control of essential beta-lactam antibiotics in low- and middle-income countries / Entwicklung einfacher und kosteneffektiver Hochleistungs-Flüssigchromatographie(HPLC)-Methoden für die Qualitätskontrolle für Betalaktam-Antibiotika in Entwicklungs- und Schwellenländern

Rasheed, Huma January 2019 (has links) (PDF)
Assay and impurity profiling of the pharmaceuticals are the key routine quality control methods employed worldwide for which High Performance Liquid Chromatography (HPLC) is the most widely used technique. The ability to carry out these routine laboratory procedures in low- and middle- income countries (LMICs) need the methods to be based upon simple instruments manageable with moderate levels of personnel skill and costs involved. Simple, convenient, and cost effective reverse phase HPLC methods were developed using phosphate buffer and methanol as mobile phase with C18 column as stationary phase for the impurity profiling and assay of beta lactam antibiotics. Isocratic elution and UV detection was employed in these methods. Impurity profiling method was developed for coamoxiclav tablets and ceftriaxone bulk drug. The method for ceftriaxone included a supplementary method to quantify one of its known impurity (Impurity D of ceftriaxone). This method involved use of acetonitrile where as the two main methods were achieved on the targeted method design, described above. With the exception of impurity A of ceftriaxone, the methods developed can successfully quantify impurities to the concentration as low as ≤0.05%, which is in accordance with the current guidelines for the impurity profiling of antibiotics issued by European Medicines Agency. As ensuring cost reduction was one of the key objectives of carrying out the method development exercise, in situ methods for the preparation of impurities were also identified and some new methods were introduced. The stability of beta lactam antibiotics and the choice of solvent were given due attention during the process of method development revealing information on the presence of new impurities. Deacetyl cefotaxime and 2-mercaptobenzathiazole were identified in this process as new impurities of ceftriaxone currently not listed under known impurities by United States Pharmacopoeia and European Pharmacopoeia. However, deacetyl cefotaxime is a known impurity of cefotaxime whereas the latter molecule is a degradation product of one of the synthesis impurities of ceftriaxone. This substance is reported to be carcinogenic and is resolved using the supplementary method developed for ceftriaxone, hence making its detection and quantification possible. A known inactive impurity of ceftriaxone (Impurity A, E-isomer of ceftriaxone) was` also shown to be produced by exposure to day light, thus warranting the light protection of the ceftriaxone solution, an information that is of critical importance in the clinical settings. A series of experimentation was carried out on the finished products of beta lactam antibiotics sampled from Pakistan and few other countries, to identify key quality issues in the samples. Though the limited sample size and convenient sampling did not provide results that could yield a decisive figure for the country status for prevalence of substandard and falsified medical products, but the experiments have clearly indicated that the problems in drug quality do exist and beta lactam antibiotics form a class of high-risk medicine with respect to surveillance for poor-quality medicines. Isolation of unknown impurities was also carried out along with the introduction of new and modified methods for preparation of impurities of beta-lactam antibiotics. In addition, detailed literature survey was carried out for understanding the complex problem of the poor-quality medicine, impact of poor quality antimicrobials on health care system and the magnitude of the problem at the global level. The country status of Pakistan regarding quality of medicines was recorded based upon the available documentary evidence. The current technologies and strategic options available for low- and middle-income countries in aiding fight for combating poor quality medicines was also laid down to design recommendations for Pakistan. A comprehensive review of the information technology tools used for identification and control of substandard and falsified medicines was also conducted. / Für die Bestimmung der Reinheit und des Gehaltes von Arzneistoffen wird weltweit maßgeblich die Hochleistungs-Flüssigchromatographie (HPLC) eingesetzt. Damit die entsprechenden Methoden auch in Entwicklungs- und Schwellenländern angewendet werden können, müssen sie zur Verwendung mit sehr einfachen Messgeräten geeignet sein und von auch weniger gut ausgebildetem Personal durchgeführt werden können. Zudem sollten die Kosten möglichst niedrig sein. Für die Reinheitsanalytik sowie die Bestimmung des Gehaltes von Betalaktam-Antibiotika wurden einfache, praktische und kostengünstige chromatographische Methoden unter Verwendung von Umkehrphasen entwickelt, die als mobile Phase Gemische aus Phosphatpuffern und Methanol sowie als stationäre Phase C18-Säulen verwenden. Die Methoden sind isokratisch, die Detektion erfolgt mittels UV/Vis-Spektrometer. Für Coamoxiclav-Tabletten sowie den Arzneistoff Ceftiaxon wurden Methoden zur Reinheitsprüfung entwickelt. Für die Reinheitsprüfung von Ceftriaxon wurde eine zweite Methode benötigt, um eine der bekannten Verunreinigungen (Ceftriaxon-Verunreinigung D) zu quantifizieren. Hierbei musste Acetonitril als Bestandteil der mobilen Phase gewählt werden, wohingegen die beiden Hauptmethoden dem beschriebenen Methodendesign folgten. Außer im Falle der Ceftriaxon-Verunreinigung A können mit den Methoden Verunreinigungen bis zu einem Konzentrationslevel ≤ 0,05 % bestimmt werden, was den Vorgaben aktueller Richtlinien für die Reinheitsanalytik der Europäischen Arzneimittelbehörde entspricht. Da es ein Kernziel während der Methodenentwicklung war, die Kosten für die Analytik möglichst gering zu halten, wurden in situ-Methoden für die Gewinnung von Verunreinigungen entwickelt und einige neue eingeführt. Während des Entwicklungsprozesses wurde besonders auf die Stabilität der Antibiotika und auf die Wahl des Lösungsmittels geachtet, wobei Erkenntnisse über die Anwesenheit neuer Verunreinigungen erlangt werden konnten. Desacetylcefotaxime und 2-Mercaptobenzathiazol wurden als neue Verwandte Substanzen von Ceftriaxon identifiziert und sind derzeit nicht als bekannte Verunreinigen in der United States Pharmacopoeia sowie dem Europäischen Arzneibuch aufgeführt. Desacetylcefotaxime ist eine bekannte Verunreinigung von Cefotaxime, wohingegen das zweite Molekül ein Abbauprodukt einer der Verunreinigungen ist, die während der Synthese von Ceftriaxon entstehen können. Es ist bekannt, dass diese Substanz karzinogen ist, und sie kann mit der erweiterten zweiten Methode für Ceftriaxon erfasst und quantifiziert werden. Unter Lichteinfluss bildete sich zudem eine weitere bekannte, inaktive Verunreinigung von Ceftriaxon (Verunreinigung A, E-Isomeres von Ceftriaxon), weshalb Ceftriaxon-haltige Lösungen vor Licht geschützt aufbewahrt werden sollten. Dieses Wissen ist besonders für den klinischen Bereich relevant. An einer Reihe von Betalaktam-haltigen Fertigarzneimitteln aus Pakistan und einigen anderen Ländern wurden mehrere Qualitätsuntersuchungen angestellt. Obwohl der geringe Probenumfang und die Methoden der Probensammlung kein eindeutiges Bild darüber zeichnen konnte, ob in einem bestimmten Land Arzneimittelfälschungen besonders häufig auftreten, konnte durch die Versuche dennoch festgestellt werden, dass es Probleme bei der Arzneimittelqualität gibt und dass Betalaktam-Antibiotika eine Hochrisikogruppe darstellen, die besonders gut hinsichtlich des Vorkommens minderwertiger Arzneimittel untersucht werden muss. Zudem wurden unbekannte Verunreinigungen aus den Proben isoliert und neue sowie modifizierte Methoden entwickelt, um Verunreinigungen der untersuchten Substanzen zu gewinnen. Zudem wurde eine ausführliche Literaturrecherche durchgeführt, um das komplexe Problem minderwertiger Arzneimittel, den Einfluss minderwertiger Antibiotika auf das Gesundheitssystem sowie das globale Ausmaß des Problems zu verstehen. Für Pakistan wurde der status quo der Arzneimittelqualität aufgrund vorhandener Dokumentation ermittelt. Außerdem wurde dargelegt, inwiefern die heutigen modernen Technologien und Strategien, die für Entwicklungs- und Schwellenländern zur Verfügung stehen, zur Bekämpfung von qualitativ minderwertigen Arzneimitteln in Pakistan beitragen können. Hierzu wurde eine Übersicht aktueller, moderner digitaler Techniken angefertigt, die für die Aufdeckung und Bekämpfung von minderwertigen und gefälschten Arzneimitteln verwendet werden können.
8

Whole Genome Amplification von Plasma-DNA und Entwicklung eines Ausschlusskriteriums zur Verbesserung der Genotypisierungsqualität / Sample selection algorithm to improve quality of genotyping from plasma-derived DNA: to separate the wheat from the chaff.

Schoenborn, Veit January 2008 (has links) (PDF)
Plasma- und Serumproben waren in früheren epidemiologischen Studien häufig das einzige biologische Material, das gesammelt und untersucht wurde. Diese Studien besitzen gerade durch ihren sehr langen Untersuchungszeitraum einen riesigen Informationsgehalt und wären ein unbezahlbarer Schatz für genetische Analysen. Oft ist aufgrund damals mangelnder Akquirierung jedoch keine genomische DNA verfügbar. Um die in Plasmaproben in geringer Menge vorkommende DNA verwenden zu können, extrahierten wir die DNA mit Hilfe von magnetischen Partikeln und setzten sie in eine Whole Genome Amplification (WGA) mittels Φ29-DNA-Polymerase ein. Wir stellten 88 Probenpärchen, bestehend aus einer WGA-Plasma-DNA und der korrespondierenden Vollblut-DNA derselben Person, zusammen und genotypisierten bei diesen neun hochpolymorphe Short Tandem Repeats (STR) und 25 SNPs. Die durchschnittliche innerhalb der Probenpaare auftretende Diskordanzrate betrug 3,8% für SNPs sowie 15,9% für STRs. Basierend auf den Ergebnissen der Hälfte der Probenpaare entwickelten wir einen Ausschlussalgorithmus und validierten diesen in der anderen Hälfte der Probenpaare. Mit diesem ist es möglich, zum Einen diejenigen Proben mit einer guten DNA-Qualität herauszufiltern, um Genotypisierungsfehler zu vermeiden, und zum Anderen jene Proben mit insuffizienter DNA-Qualität auszuschließen. Nachdem Proben, die fünf oder mehr homozygote Loci in dem 9-STR-Markerset aufwiesen, ausgeschlossen wurden, resultierte dies in einer Ausschlussrate von 22,7% und senkte die durchschnittliche Diskordanzrate auf 3,92% für STRs bzw. 0,63% für SNPs. Bei SNPs entspricht dieser Wert ungefähr der Fehlerquote, wie er auch bei Genotypisierungen mit Vollblut-DNA in vielen Laboratorien auftritt. Unsere Methode und das Ausschlusskriterium bieten damit neue Möglichkeiten, um zuverlässige DNA aus archivierten Plasmaproben wiederzugewinnen. Dieser Algorithmus ist auch besser geeignet, als nur die eingesetzte DNA-Menge in die WGA-Reaktion als Kriterium zu benützen. / Plasma and serum samples were often the only biological material collected for earlier epidemiological studies. These studies have a huge informative content, especially due to their long follow-up and would be an invaluable treasure for genetic investigations. However, often no banked DNA is available. To use the small amounts of DNA present in plasma, in a first step, we applied magnetic bead technology to extract this DNA, followed by a whole-genome amplification (WGA) using phi29-polymerase. We assembled 88 sample pairs, each consisting of WGA plasma DNA and the corresponding whole-blood DNA. We genotyped nine highly polymorphic short tandem repeats (STRs) and 23 SNPs in both DNA sources. The average within-pair discordance was 3.8% for SNPs and 15.9% for STR genotypes, respectively. We developed an algorithm based on one-half of the sample pairs and validated on the other one-half to identify the samples with high WGA plasma DNA quality to assure low genotyping error and to exclude plasma DNA samples with insufficient quality: excluding samples showing homozygosity at five or more of the nine STR loci yielded exclusion of 22.7% of all samples and decreased average discordance for STR and SNP markers to 3.92% and 0.63%, respectively. For SNPs, this is very close to the error observed for genomic DNA in many laboratories. Our workflow and sample selection algorithm offers new opportunities to recover reliable DNA from stored plasma material. This algorithm is superior to testing the amount of input DNA.
9

Quantitative NMR-Spektroskopie in der pharmazeutischen Analytik -- Identität, Reinheit und Gehalt von Arzneistoffen / Quantitative NMR spectroscopy in pharmaceutical analysis -- Identity, purity and content of drugs

Beyer, Tanja January 2011 (has links) (PDF)
Das Ziel der vorliegenden Arbeit war die Klärung der Fragestellung, ob sich die quantitative NMR-Spektroskopie zur Bestimmung von Identität, Reinheit und Gehalt von Arzneistoffen eignet, und wie sich Präzision und Empfindlichkeit dieser Methode im Vergleich zu etablierten chromatographischen Verfahren verhalten. Die quantitative Untersuchung der drei strukturell jeweils verwandten Mehrkomponentengemische Codergocrinmesilat, Clomifencitrat und Flupentixoldihydrochlorid bewies eindrucksvoll die Eignung der 1H-NMR-Spektroskopie als orthogonale, analytische Messmethode im Vergleich zu validierten HPLC-Arzneibuchmethoden. Die im Rahmen einer Validierung der 1H-NMR-Methode ermittelten Ergebnisse erfüllten bezüglich Präzision und Richtigkeit die an eine im pharmazeutischen Bereich eingesetzte analytische Methode gestellten Anforderungen; zudem wurden weitere Prüfparameter wie Selektivität, Linearität, Robustheit und Stabilität verifiziert. Externe-Standard-Experimente wie "Zwei-Röhrchen-Methode" und ERETIC-Verfahren bestätigten die quantitativen Ergebnisse der Internen Standardisierung; jedoch wurde hier -- insbesondere für die ERETIC-Technik -- eine höhere Fehleranfälligkeit und somit eine größere Streuung der Einzelergebnisse beobachtet. Am Beispiel von Codergocrinmesilat und Flupentixoldihydrochlorid konnte zudem die Eignung anderer NMR-aktiver Kerne wie 13C und 19F für die quantitative Analyse von komplexen Substanzgemischen aufgezeigt werden. Das Potential der 1H-NMR-Spektroskopie für die Reinheitsprüfung von Arzneistoffen wurde am Beispiel der Aminosäure L-Alanin aufgezeigt. Die zu erwartenden Verunreinigungen Glutamin-, Asparagin-, Äpfel- und Fumarsäure konnten im Gegensatz zu den "veralteten" Prüfmethoden des Europäischen Arzneibuches eindeutig identifiziert und quantifiziert werden; mit einer Bestimmungsgrenze von <= 0.03% wurden die Vorgaben der ICH-Richtlinie Q3A(R2) erfüllt. Die deutliche Übereinstimmung der NMR-spektroskopisch ermittelten Ergebnisse einer quantitativ untersuchten Alanin-Modellmischung mit einer für den Routinebetrieb geeigneten HPLC-Methode unter Einsatz verschiedener Detektoren wie CAD, NQAD, ELSD und MS, sowie der Vergleich wichtiger Prüfparameter wie Linearität und Nachweisgrenze bestätigten die Eignung der 1H-NMR-Spektroskopie im Rahmen der routinemäßig durchgeführten Qualitätskontrolle. Die Aufdeckung von Arzneimittelfälschungen mit Hilfe der NMR-Spektroskopie wurde im Rahmen dieser Arbeit anhand der zwei aktuellen Fallbeispiele Heparin und Glycerin näher untersucht. Die in Zusammenhang mit dem Heparin-Skandal verantwortliche Kontaminante OSCS konnte neben Dermatansulfat und weiteren natürlich vorkommenden Glykosaminoglykan-Verunreinigungen im 1H-NMR-Spektrum eindeutig identifiziert und auf 0.1% OSCS bzw. 0.5% Dermatansulfat begrenzt werden. Eine präzise und richtige quantitative Bestimmung der beiden Glykosaminoglykane wurde über die N-Acetyl-Resonanzen mit Hilfe der Signalhöhenbestimmung und dem Standard-Additionsverfahren ermöglicht; deutliche Abweichungen vom "wahren" Gehalt wurden hingegen, bedingt durch starke Signalüberlagerungen, nach Flächenvergleich beobachtet. Weitere Verunreinigungen, insbesondere Lösungsmittelrückstände, die während des Extraktions- und Reinigungsprozesses des Heparins eingesetzt werden, konnten ebenfalls über charakteristische Resonanzen identifiziert und mit Hilfe der Internen-Standard-Methode quantitativ erfasst werden. Eine umfangreiche Untersuchung von 145 Heparin-API-Mustern mittels NMR-Spektroskopie und weiteren, neuentwickelten Verfahren wie HPLC, CE, IR- und Raman-Spektroskopie konnte die Eignung der entwickelten 1H-NMR-Methode bestätigen. Potentielle Glycerin-Kontaminanten wie Diethylenglycol und Ethylenglycol konnten ebenso wie eine weitere, natürlich vorkommende Verunreinigung, Propylenglycol, mittels 1H- und 13C-NMR-Spektroskopie identifiziert und quantifiziert werden. Beide Methoden erfüllten die in der USP beschriebenen Anforderungen, die für pharmazeutisch eingesetztes Glycerin jeweils höchstens 0.1% Diethylenglycol bzw. Ethylenglycol erlaubt. Während die quantitative Reinheitsprüfung beim Einsatz der 1H-NMR-Spektroskopie mit einer Messdauer im Bereich von etwa 30 min für den Routineeinsatz geeignet ist, ist die entwickelte quantitative 13C-NMR-Methode beim Einsatz von Spektrometern geringer Magnetfeldstärke aufgrund einer geringen Nachweisempfindlichkeit und der NOE-Problematik für den Routinebetrieb nur bedingt anwendbar. Abschließend kann zusammengefasst werden, dass die untersuchten Beispiele die NMR-Spektroskopie als in hohem Maße geeignet für die quantitative Analyse von Arzneimitteln ausweisen. / The main objective of the present thesis was the investigation of the suitability of quantitative NMR spectroscopy for identification, purity assay, and quantification of a given drug, as well as a comparison of precision and sensitivity of this method with well-established chromatographic routines. The quantitative analysis of the three multi-component drug mixtures codergocrine mesylate, clomiphene citrate, and flupentixol dihydrochloride strikingly demonstrates the suitability of the 1H NMR spectroscopy as an independent analytical measurement technique in comparison to validated HPLC methods of international pharmacopoeias. Concerning precision and accuracy, the results obtained from validation of the 1H NMR method met the requirements that are made on an analytical routine for pharmaceutical purposes; additionally, further validation parameters such as selectivity, linearity, robustness, and stability have been verified. Experiments like the "twin tube" and ERETIC techniques utilizing external standards confirm these results; however, in this context an increased error rate and therefore larger variance was observed, especially in the case of ERETIC. By means of codergocrine mesylate and flupentixol dihydrochloride, additionally the suitability of other NMR active nuclei as 13C or 19F for quantification of complex mixtures was shown. The potential of the 1H NMR spectroscopy for purity assays was demonstrated for the example of the amino acid L-alanin. Identification and quantification of the expected impurities glutamic acid, aspartic acid, malic acid, and fumaric acid was possible, in contrast to "out-dated" test methods of the European Pharmacopoeia; achieving a limit of quantification <= 0.03%, the demands of the ICH guideline Q3A(R2) have been met. Concerning the quantification of an alanine model mixture, the clear agreement between the results obtained by means of NMR spectroscopy and a HPLC method using various detectors like CAD, NQAD, ELSD, and MS, suited for routine analysis, as well as the comparison of various relevant parameters such as linearity and limit of quantification confirmed the qualification of 1H NMR spectroscopy in the field of routine quality assurance. Within the scope of this work, the disclosure of counterfeit drugs by means of NMR spectroscopy was investigated in detail utilizing two current case studies, namely heparin and glycerin. Besides dermatan sulfate and other natural occurrences of glycosaminoglycan impurities, the contaminant OSCS revealed in connection with the recent heparin affair was clearly identified in the 1H NMR spectrum and these contaminants could be limited to 0.1% OSCS and 0.5% dermatan sulfate, respectively. A precise and accurate quantification of these two glycosaminoglycanes was achieved using signal height and standard addition methods applied to the N-acetyl resonances; comparison of signal areas however yielded considerable deviations from the "true" content, which are due to strong signal overlap. Further contaminants, especially solvent residues originating from the extraction and purification processes of heparin, have been able to be identified with the help of characteristic resonances; their quantification was possible. An extensive study of 145 heparin API samples by means of NMR spectroscopy and other novel techniques such as HPLC, capillary electrophoresis, IR and Raman spectroscopy confirmed the qualification of the developed 1H NMR method. Potential contaminants in glycerin such as diethylene glycol and ethylene glycol have been able to be identified as well as quantified by means of 1H and 13C NMR spectroscopy, as was the case for propylene glycol, which is naturally present. Both methods met the requirements of the USP, limiting the amount of diethylene glycol and ethylene glycol for pharmaceutical purposes to 0.1%, respectively. While 1H NMR spectroscopy with a measurement time of about 30 min is well suited for routine application, the applicability of the 13C NMR method is limited due to the NOE effect and the low sensitivity at low field strengths. In conclusion, each of the attended topics showed, that NMR spectroscopy is a powerful tool within the framework of quantitative drug analysis.
10

Collaborative Tagging - neue Möglichkeiten für die bibliothekarische Sacherschließung

Krätzsch, Christine, Niemann, Christof 12 August 2009 (has links) (PDF)
Die große Freiheit von Tagging-Systemen, wie sie zunehmend auch von wissenschaftlichen Bibliotheken eingesetzt werden, ist ein ambivalentes Phänomen. Zum einen bietet das „Tagging“ Kundennähe und beachtliches kreatives Potenzial, zum anderen erzeugt es jedoch große Mengen völlig unkontrollierter Meta- Informationen, über deren Qualität noch Unklarheit besteht. Die Universität Mannheim widmet sich in zwei kooperierenden DFG-Projekten dieser Problematik. Im Vortrag wurde die Implementierung eines Tagging-Systems im Online-Katalog sowie die Anwendung einer selbst entwickelten Opensource-Software zur Qualitätskontrolle von Klassifikationen und Tagging-Daten mittels innovativer Visualisierungstechnik und statistischer Methoden vorgestellt.

Page generated in 0.1495 seconds