Determinação das doses de radiação produzidas durante a obtenção de radiografias periapicais com o emprego da dosimetria termoluminescente

Boscolo, Frab Norberto, 1942- 03 August 2018 (has links)
Orientador : Nivaldo Gonçalves / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T12:41:05Z (GMT). No. of bitstreams: 1 Boscolo_FrabNorberto_D.pdf: 6606172 bytes, checksum: 533ac47f14fc57a8685bb78629364017 (MD5) Previous issue date: 1976 / Resumo: Não informado / Abstract: Not informed / Doutorado / Semiologia / Doutor em Ciências
2

Avaliação da dose de radiação absorvida em exames radiológicos durante o planejamento radioterápico

Camargo, Rafaela Ferraz de [UNESP] 18 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-18Bitstream added on 2015-01-26T13:30:40Z : No. of bitstreams: 1 000794951.pdf: 1115711 bytes, checksum: 4c1e59b3111229911b6794fde269fab1 (MD5) / A radioterapia é uma modalidade médica que emprega radiações ionizantes para o tratamento de doenças. O sucesso da terapêutica depende de vários fatores, dentre eles a liberação precisa da dose de radiação no volume tumoral e a perfeita reprodutibilidade diária das orientações prescritas na ficha técnica do paciente. A delimitação do campo de radiação, o qual deve abranger todo o tumor e permitir uma margem de segurança que considere a movimentação anatômica, é feita durante os procedimentos de planejamento radioterápico. Nesta etapa do tratamento, o médico radioterapeuta, auxiliado pelo físico médico e o tecnólogo em radiologia, utiliza técnicas radiográficas através de um sistema de escopia para visualização do volume alvo de irradiação, e realiza imagens radiográficas estáticas para documentação do caso clínico. Na rotina dos procedimentos de planejamento radioterápico, normalmente não é feita a quantificação da dose de radiação liberada no procedimento, devido principalmente à grande e exaustiva agenda de atividades dos profissionais envolvidos. Neste trabalho foi avaliada a dose de radiação liberada em exames radiológicos realizados durante o planejamento radioterápico, avaliando a influência desta dose no total de exposições em que o paciente foi submetido durante todo o curso da radioterapia. A pesquisa consistiu no acompanhamento dos procedimentos de planejamento radioterápico executadas no Serviço Técnico de Radioterapia da Faculdade de Medicina da UNESP de Botucatu, extraindo os valores das técnicas radiográficas empregas para diferentes planejamentos. Após a caracterização individualizada do planejamento, as técnicas radiográficas utilizadas em cada um dos casos clínicos, foram repetidas e as doses de radiação liberadas no procedimento foram quantificadas por meio de detectores de radiação específicos e calibrados para a energia dos raios-x de ... / Radiotherapy is a medical modality that uses ionizing radiation for the treatment of diseases. The treatment success depends on several factors, including the precise release of the radiation dose in the tumor volume and the perfect daily reproducibility of the guidelines prescribed in the technical sheet of the patient. The delimitation of the radiation field, which should cover the entire tumor and allow a safety margin that considers the anatomical movement, is taken during the procedures of the radiotherapy planning. At this stage of treatment, the radiotherapist physician, aided by the medical physicist and the technologist in radiology, utilizes radiographic techniques through a system of scopy to visualize the target volume of irradiation, and performs static radiographic images to document the clinical case. In the routine of the radiotherapy planning procedures, usually is not performed the quantification of the radiation dose released in the procedure, mainly due to the large and exhaustive schedule of activities of the professionals involved. In this study, was assessed the radiation dose released in radiological examinations performed during the radiotherapy planning, evaluating the influence of this dose in the exposures total in which the patient has undergone throughout the radiotherapeutic procedure. The research consisted in monitoring the radiotherapy planning procedures performed at UNESP, “Serviço Técnico de Radioterapia” of “Faculdade de Medicina de Botucatu”, extracting the radiographic technique values used for different plannings. After the individualized characterization of the plannning, the radiographic techniques used in each clinical case, were repeated and the radiation doses released in the procedure were quantified by specific radiation detectors and they were calibrated to the energy of the simulation x-ray. It is concluded that the absorbed radiation dose, which ...
3

Avaliação da dose de radiação absorvida em exames radiológicos durante o planejamento radioterápico /

Camargo, Rafaela Ferraz de. January 2014 (has links)
Orientador: Batista de Oliveira Júnior / Coorientador: Marco Antonio Rodrigues Fernandes / Banca: Vladimir Eliodoro da Costa / Banca: Vidal Haddad Júnior / Resumo: A radioterapia é uma modalidade médica que emprega radiações ionizantes para o tratamento de doenças. O sucesso da terapêutica depende de vários fatores, dentre eles a liberação precisa da dose de radiação no volume tumoral e a perfeita reprodutibilidade diária das orientações prescritas na ficha técnica do paciente. A delimitação do campo de radiação, o qual deve abranger todo o tumor e permitir uma margem de segurança que considere a movimentação anatômica, é feita durante os procedimentos de planejamento radioterápico. Nesta etapa do tratamento, o médico radioterapeuta, auxiliado pelo físico médico e o tecnólogo em radiologia, utiliza técnicas radiográficas através de um sistema de escopia para visualização do volume alvo de irradiação, e realiza imagens radiográficas estáticas para documentação do caso clínico. Na rotina dos procedimentos de planejamento radioterápico, normalmente não é feita a quantificação da dose de radiação liberada no procedimento, devido principalmente à grande e exaustiva agenda de atividades dos profissionais envolvidos. Neste trabalho foi avaliada a dose de radiação liberada em exames radiológicos realizados durante o planejamento radioterápico, avaliando a influência desta dose no total de exposições em que o paciente foi submetido durante todo o curso da radioterapia. A pesquisa consistiu no acompanhamento dos procedimentos de planejamento radioterápico executadas no Serviço Técnico de Radioterapia da Faculdade de Medicina da UNESP de Botucatu, extraindo os valores das técnicas radiográficas empregas para diferentes planejamentos. Após a caracterização individualizada do planejamento, as técnicas radiográficas utilizadas em cada um dos casos clínicos, foram repetidas e as doses de radiação liberadas no procedimento foram quantificadas por meio de detectores de radiação específicos e calibrados para a energia dos raios-x de ... / Abstract: Radiotherapy is a medical modality that uses ionizing radiation for the treatment of diseases. The treatment success depends on several factors, including the precise release of the radiation dose in the tumor volume and the perfect daily reproducibility of the guidelines prescribed in the technical sheet of the patient. The delimitation of the radiation field, which should cover the entire tumor and allow a safety margin that considers the anatomical movement, is taken during the procedures of the radiotherapy planning. At this stage of treatment, the radiotherapist physician, aided by the medical physicist and the technologist in radiology, utilizes radiographic techniques through a system of scopy to visualize the target volume of irradiation, and performs static radiographic images to document the clinical case. In the routine of the radiotherapy planning procedures, usually is not performed the quantification of the radiation dose released in the procedure, mainly due to the large and exhaustive schedule of activities of the professionals involved. In this study, was assessed the radiation dose released in radiological examinations performed during the radiotherapy planning, evaluating the influence of this dose in the exposures total in which the patient has undergone throughout the radiotherapeutic procedure. The research consisted in monitoring the radiotherapy planning procedures performed at UNESP, "Serviço Técnico de Radioterapia" of "Faculdade de Medicina de Botucatu", extracting the radiographic technique values used for different plannings. After the individualized characterization of the plannning, the radiographic techniques used in each clinical case, were repeated and the radiation doses released in the procedure were quantified by specific radiation detectors and they were calibrated to the energy of the simulation x-ray. It is concluded that the absorbed radiation dose, which ... / Mestre
4

Cálculo da dose de radiação através de convoluções em meios heterogêneos para aplicações em radioterapia

Perles, Luis Augusto 20 October 2000 (has links)
Orientador: Carola Dobrigkeit Chinellato / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-07-28T02:47:42Z (GMT). No. of bitstreams: 1 Perles_LuisAugusto_M.pdf: 1248295 bytes, checksum: 6cd75720bf40b787ab7f86ea6ca15b5b (MD5) Previous issue date: 2001 / Resumo: Nesta dissertação de mestrado apresentamos o estudo sobre uma técnica de convolução para o cálculo da distribuição da dose de radiação usada em teleterapia. Este método decompõe em três parcelas a distribuição da energia absorvida pelo meio: uma devida à dose do espalhamento primário, uma devida à dose do espalhamento secundário e uma terceira, devida aos espalhamentos de ordens superiores. Mostramos todo o desenvolvimento teórico do método de cálculo da dose de radiação por convoluções para meios homogêneos e heterogêneos, onde os tecidos moles são tratados todos como tendo a mesma seção de choque que a água. As heterogeneidades são tratadas como de densidades diferentes da água, porém com a mesma seção de choque da água. As funções de transporte de elétrons e fótons foram simuladas no EGS4. Fizemos os cálculos para a energia do 60Co e os resultados apresentaram uma boa concordância quando comparados a resultados experimentais e simulados para campos de até 10 x 10 cm2 a uma profundidade de 26 cm. Com o aumento das dimensões do campo, a profundidade em que há confiabilidade reduz-se. Este fato se deve ao espaço limitado em que o programa EGS4 realiza as simulações dos transportes de fótons de altas ordens de espalhamento. O programa desenvolvido para o cálculo da distribuição de dose de radiação nesta tese tem por objetivo servir de base para outros estudos e pesquisas relativas à aplicação deste método e também poderá ser usado no dia-a-dia da radioterapia após os devidos testes de confiabilidade / Abstract: In this thesis we have applied the convolution techniques to calculate the three dimensional (3D) dose distribution to be used in teletherapy. The convolution method spans the total dose in three parts: one due to the energy released by charged particles produced at the first collisions, one due to the energy released by the first scattered photons, and the last one due to photons of higher order scattering. We have shown up the theoretical development for homogeneous and inhomogeneous media. Cross sections of tissues have been approximated to water like. Heterogeneities are supposed to have the same cross sections as water and their densities have been treated as weight for the dose computations. Electron and photon functions were simulated in a previous step using EGS4. We have done the calculations for 60Co energy and the results have shown good agreement with experimental data sets for .elds less than 10 x 10 cm2 at 26 cm depth. For larger fields the depth of agreement was reduced. We have associated this fact to the limitation of simulation steps, during transport of photons of higher order scattering. The aim of the software developed to calculate the radiation dose distribution in this thesis is to be the basis for other studies and researches related. The appliance in radiotherapy routine will be evaluated after confiability tests / Mestrado / Física / Mestre em Física
5

Estudo da dose ocupacional no laboratorio de cateterismo cardiaco do HC da Unicamp : fluoroscopia pulsada versus flouroscopia continua / Occupational dose study in the cardic catheterism laboratory of Unicamp's HC : pulsed fluoroscopy versus continous fluoroscopy

Ferraz, Mariana Sacrini Ayres 14 August 2018 (has links)
Orientador: Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T23:21:55Z (GMT). No. of bitstreams: 1 Ferraz_MarianaSacriniAyres_M.pdf: 4432455 bytes, checksum: 653b956278da2f0d25423b525a3311d0 (MD5) Previous issue date: 2009 / Resumo: Exames de cateterismo que utilizam fluoroscopia, como a angioplastia coronariana, são responsáveis por altas doses de radiação (maiores que na radiologia convencional), tanto para os pacientes como para a equipe médica. O uso intensivo dos raios X faz com que aumentem os riscos radiológicos, em decorrência da alta exposição cumulativa durante a vida dos cardiologistas intervencionistas e suas equipes. Os principais riscos decorrentes de altas doses de raios X são: câncer, cataratas, malformações e danos ao feto de mulheres grávidas. A geração de raios X com tecnologia pulsada, que se tornou disponível aos hospitais, representa uma potencial redução da dose de radiação recebida pela equipe profissional. O montante de redução da dose ainda é objeto de controvérsias na literatura, mas alguns autores descrevem reduções de até 70%. Este trabalho teve por objetivo o estudo da dose ocupacional no Laboratório de Cateterismo Cardíaco da UNICAMP. Foram comparadas as doses recebidas pela equipe para a fluoroscopia contínua e pulsada, e a diminuição proporcionada pela troca do equipamento de fluoroscopia contínua pelo pulsado no Laboratório foi quantificada. As diminuições encontradas para os médicos, principal e auxiliar, foram de 5,2% e 13,7% respectivamente. Para os enfermeiros e auxiliares de enfermagem foram de 7,5% e 8,2%. Além disso, foram calculadas as doses efetivas por procedimento para cada profissional, e foi feita uma análise dos dados dos dosímetros termoluminescentes usados em todo o período de funcionamento do Laboratório. Em conclusão, a diminuição proporcionada pela tecnologia pulsada não foi significativa, e neste trabalho são propostas novas estratégias para reduzir a dose ocupacional no Laboratório de Cateterismo. / Abstract: Procedures of catheterism using fluoroscopy, as coronary angioplasty, are responsible for high doses of radiation (higher than conventional radiology), not only for patients but for the medical staff as well. The intensive use of X-rays increases radiological risks, as a consequence of cumulative exposition, for cardiologists and their teams. The main risks resulted from high doses of X-rays are: cancer, cataracts, malformations, and damage to the fetuses of pregnant women. The production of X-rays with pulsed technology, which is now available in many hospitals, implies a potential reduction of the radiation dose received by the medical staff. The amount of dose reduction is still controversy in literature, but some authors report reductions up to 70%. This work aimed at study occupational dose in the Cardiac Catheterism Laboratory of UNICAMP. The doses received by the medical staff on the continuous and pulsed fluoroscopy modes were compared, and the dose reduction consequent to the change of technologies in the Laboratory (from continuous to pulsed fluoroscopy) was measured. The reductions found for main and auxiliary physicians were 5.2% and 13.7%, respectively. For nurses, auxiliary nurses and technicians, the reductions were 7.5% to 8.2%. Moreover, the effective dose of each procedure for each professional was calculated and data analysis of the thermoluminescent dosimeters used in the whole Laboratory working periods was made. In conclusion, the dose reduction caused by pulsed technology was not significant, and new strategies to reduce occupational doses in the Catheterism Laboratory are proposed. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
6

Implementação de um sistema detector piroelétrico para medição de intensidade de radiação X na faixa de ortovoltagem

Pontes, Wesley [UNESP] 31 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-31Bitstream added on 2014-06-13T18:08:36Z : No. of bitstreams: 1 pontes_w_me_ilha.pdf: 1981877 bytes, checksum: 1035203a106889688fd34bda8f3d2eed (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho descreve-se um sistema detector piroelétrico de intensidade (taxa de fluência de energia) de raios X, para a faixa de ortovoltagem (80 a 300 kVp), constituído essencialmente por uma câmara piroelétrica, um circuito microcontrolado e um display de cristal líquido. A radiação foi produzida por um equipamento de ortovoltagem Siemens Stabilipan II. A câmara possui no seu interior um sensor piroelétrico e um conversor correntetensão de alta sensibilidade, que tem como principal componente um amplificador operacional OPA111 (Burr-Brown). Utilizou-se um osciloscópio digital e um circuito microcontrolado associado ao display para a medição da amplitude dos pulsos de sinal elétrico decorrentes dos pulsos de raios X incidentes no sensor. A resposta do sistema detector piroelétrico foi linear com a intensidade da radiação, em uma faixa de sua resposta, com alguns dos materiais utilizados. O sensor PZT Fe (zirconato titanato de chumbo com ferro) apresentou a melhor sensibilidade para uma grande faixa de tensão sendo assim o mais adequado para utilização em medições de intensidade de radiação X. Dos resultados obtidos, a precisão, resolução e sensibilidade do sistema detector, com os diferentes sensores piroelétricos, associados ao seu baixo custo, construção relativamente simples e facilidade de realização das medições, podem torná-lo muito útil no monitoramento de radiação produzida por equipamentos de ortovoltagem. / In this work a pyroeletric detector system is described for measuring the energy fluence rate (intensity) of x-ray pulses in the ortovoltage range (from 80 to 300 kVp), consisting of a pyroeletric chamber, a microcontrolled circuit, and a liquid crystal display (LCD). The radiation was produced by an ortovoltage equipment Siemens Stabilipan II. The pyroeletric chamber consists essentially of a pyroeletric detector and a current-to-voltage converter that has an operational amplifier OPA 111 (Burr-Brown) as the main component. The electrical pulses produced by the radiation was measured with an oscilloscope and a microcontrolled circuit associated to a LCD. The pyroelectric detector response to a radiation pulse showed linear relationship between the peak electric signal produced by the detector and the intensity of the x-ray pulses in some materials used. The PZT fe showed the most sensibility for a bigger voltage range being thus the most adjusted for measuring the intensity of radiation X. The precision, resolution, and sensibilities of the pyroelectric detector system, with the different pyroeletric sensors, associated with his low cost, relatively simple construction, and easiness for using the device, can turn it very useful for measuring the intensity of radiation produced by ortovoltage equipments.
7

Implementação de um sistema detector piroelétrico para medição de intensidade de radiação X na faixa de ortovoltagem /

Pontes, Wesley. January 2006 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Walter Katsumi Sakamoto / Banca: Adelaide de Almeida / Resumo: Neste trabalho descreve-se um sistema detector piroelétrico de intensidade (taxa de fluência de energia) de raios X, para a faixa de ortovoltagem (80 a 300 kVp), constituído essencialmente por uma câmara piroelétrica, um circuito microcontrolado e um display de cristal líquido. A radiação foi produzida por um equipamento de ortovoltagem Siemens Stabilipan II. A câmara possui no seu interior um sensor piroelétrico e um conversor correntetensão de alta sensibilidade, que tem como principal componente um amplificador operacional OPA111 (Burr-Brown). Utilizou-se um osciloscópio digital e um circuito microcontrolado associado ao display para a medição da amplitude dos pulsos de sinal elétrico decorrentes dos pulsos de raios X incidentes no sensor. A resposta do sistema detector piroelétrico foi linear com a intensidade da radiação, em uma faixa de sua resposta, com alguns dos materiais utilizados. O sensor PZT Fe (zirconato titanato de chumbo com ferro) apresentou a melhor sensibilidade para uma grande faixa de tensão sendo assim o mais adequado para utilização em medições de intensidade de radiação X. Dos resultados obtidos, a precisão, resolução e sensibilidade do sistema detector, com os diferentes sensores piroelétricos, associados ao seu baixo custo, construção relativamente simples e facilidade de realização das medições, podem torná-lo muito útil no monitoramento de radiação produzida por equipamentos de ortovoltagem. / Abstract: In this work a pyroeletric detector system is described for measuring the energy fluence rate (intensity) of x-ray pulses in the ortovoltage range (from 80 to 300 kVp), consisting of a pyroeletric chamber, a microcontrolled circuit, and a liquid crystal display (LCD). The radiation was produced by an ortovoltage equipment Siemens Stabilipan II. The pyroeletric chamber consists essentially of a pyroeletric detector and a current-to-voltage converter that has an operational amplifier OPA 111 (Burr-Brown) as the main component. The electrical pulses produced by the radiation was measured with an oscilloscope and a microcontrolled circuit associated to a LCD. The pyroelectric detector response to a radiation pulse showed linear relationship between the peak electric signal produced by the detector and the intensity of the x-ray pulses in some materials used. The PZT fe showed the most sensibility for a bigger voltage range being thus the most adjusted for measuring the intensity of radiation X. The precision, resolution, and sensibilities of the pyroelectric detector system, with the different pyroeletric sensors, associated with his low cost, relatively simple construction, and easiness for using the device, can turn it very useful for measuring the intensity of radiation produced by ortovoltage equipments. / Mestre