• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 1
  • Tagged with
  • 337
  • 337
  • 145
  • 87
  • 71
  • 56
  • 55
  • 52
  • 42
  • 40
  • 40
  • 39
  • 39
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Estudo da influência de partículas de ouro na dose absorvida em tecido mole utilizando dosimetria com gel polimérico / Study of the influence of gold particles on the absorbed dose in soft tissue using polymer gel dosimetry

AFONSO, LUCIANA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:40Z (GMT). No. of bitstreams: 0 / A presença de material de alto número atômico adjacente ao tecido mole aumenta localmente a dose absorvida pelo tecido quando submetido à radiação. Este efeito ocorre devido aos fotoelétrons ejetados do material de alto número atômico. Dosímetros de gel polimérico com partículas de ouro foram utilizados para investigar este efeito. Foram realizados cálculos analíticos para estimar o aumento de dose e simulações com o método de Monte Carlo. A irradiação de amostras de gel polimérico (GP) puro e com 0,005 gAu/gGP utilizando um feixe de raios X produzido por um potencial de 150 kV filtrado com 4 mmAl e 5 mmCu resultou em uma dose absorvida pelas amostras com ouro aproximadamente 20% maior que a dose absorvida pelas amostras de gel polimérico puro. Os cálculos analíticos e a simulação com o método de Monte Carlo resultaram em um aumento de aproximadamente 30% na dose absorvida. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
152

Estudo da exalação de randônio em placas e tijolos de fosfogesso de diferentes procedências / Study of radon exhalation from phosphogypsum plates and blocks from different origins

COSTA, LUCAS J.P. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / O fosfogesso é um resíduo da indústria de fertilizantes fosfatados que concentra radionuclídeos naturais. Neste trabalho foi estudada a taxa de exalação de 222Rn em placas e tijolos de fosfogesso, visando sua utilização na construção de residências. Para tanto, foram determinadas a taxa de exalação de 222Rn por meio da técnica da câmara de acumulação com detectores sólidos de traços nucleares (SSNTD) inseridos em uma câmara de difusão e a dose efetiva para um indivíduo habitando uma residência construída com esses materiais. A título de comparação foi também determinada a taxa de exalação teórica, por meio do modelo proposto pela UNSCEAR, a partir da concentração de 226Ra nas placas e tijolos de fosfogesso. A contribuição do revestimento na superfície dos materiais para a diminuição da taxa de exalação de radônio foi também avaliada. Foram estudados placas e tijolos fabricados com fosfogesso das empresas Bunge Fertilizantes, Ultrafertil e Fosfertil e tijolos fabricados com gesso comum. Os valores médios obtidos foram 0,19 0,06 Bq m-2 h-1, 1,3 0,3 Bq m-2 h-1 e 0,41 0,07 Bq m-2 h-1 para as placas fabricadas com fosfogesso proveniente das empresas Bunge, Ultrafertil e Fosfertil, respectivamente. Já para os tijolos de fosfogesso, os valores foram 0,11 0,01 Bq m-2 h-1, 1,2 0,6 Bq m-2 h-1, 0,47 0,15 Bq m-2 h-1, para o fosfogesso da Bunge, Ultrafertil e Fosfertil. O tijolo fabricado com gesso comum apresentou valor médio de 0,18 0,08 Bq m-2 h-1. As doses efetivas anuais para um indivíduo habitando uma residência construída como os tijolos ou placas de fosfogesso de qualquer uma das procedências ficaram abaixo do limite de dose efetiva para indivíduos do público de 1 mSva-1 estabelecido pela Comissão Internacional de Proteção Radiológica. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
153

Pré-tratamento do bagaço de cana utilizando o processo de oxidação avançada por feixe de elétrons para hidrólise enzimática da celulose / Pretreatment of sugarcane bagasse using the advanced oxidation process by electron beam for enzymatic hydrolysis of cellulose

RIBEIRO, MARCIA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:36Z (GMT). No. of bitstreams: 0 / O bagaço de cana de açúcar é uma fonte de energia renovável e matéria prima promissora na produção de biocombustível, pois representa cerca de 30% de glicose contida na planta com potencial de ser hidrolisado e convertido em etanol. Os principais constituintes do bagaço de cana são a celulose, formada por cadeia linear de glicose, a hemicelulose, um polímero amorfo constituído de xilose, arabinose, galactose e manose e a lignina, um polímero complexo formado por unidades de fenilpropanos que atuam como revestimento impermeabilizante nas fibras, difícil de ser removido por sua característica recalcitrante. O objetivo do presente trabalho foi avaliar a eficiência da irradiação com feixe de elétrons como pré-tratamento do bagaço de cana para hidrólise enzimática da celulose. O pré-tratamento do bagaço de cana é uma das etapas mais importante para torná-lo economicamente viável e competitivo na produção de energia. Como pré-tratamento o processamento por feixe de elétrons pode fragilizar a estrutura da hemicelulose e lignina, pela ação de radicais altamente reativos que quebram as ligações químicas, reduzindo o grau de polimerização das fibras. Foram avaliados os efeitos da radiação na estrutura e composição do bagaço, assim como a combinação do processamento por feixe de elétrons com o pré-tratamento de esplosão à vapor. Para hidrólise enzimática utilizou-se enzimas comerciais fornecidas pela Novozymes. O processamento por feixe de elétrons levou a alterações na estrutura e composição do bagaço de cana aumentando a solubilidade pela degradação de celulose alfa e hemicelulose e aumentando também o rendimento da hidrólise enzimática. No caso do bagaço explodido, não houve alteração no rendimento da hidrólise enzimática, mas o processamento por feixe de elétrons promoveu uma redução de 67% no furfural, que é formado no processo de explosão a vapor. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
154

Alteracoes bioquimicas e imunologicas do veneno de Bothrops jararacussu irradiado com 60supCo

SPENCER, PATRICK J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:52Z (GMT). No. of bitstreams: 1 02760.pdf: 2199881 bytes, checksum: 667afa150258a68d2030168187d89158 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
155

Validacao de metodologia analitica para determinacao de mercurio total em amostras de urina por espectrometria de absorcao atomica com geracao de vapor frio (CV_AAS) / Validation of an analytical method for the determination of total mercury in urine samples using cold vapor atomic absorption spectrometry (CV-AAS)

GUILHEN, SABINE N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:54Z (GMT). No. of bitstreams: 0 / O merc´urio (Hg) ´e um metal t´oxico empregado em uma variedade de produtos e processos, representando um risco `a sa´ude dos ind´viduos expostos ocupacional ou acidentalmente a este metal. O am´algama dental ´e um material restaurador que cont ´em Hg met´alico e cujo uso tem sido bastante debatido nas ´ultimas duas d´ecadas. Em vista da dubiedade dos estudos cient´ficos acerca do am´algama dental, muitos esfor¸cos tem sido direcionados `a esta questao. Recentemente, a Funda¸cao de Medicina Tropical do Tocantins iniciou um estudo para avaliar os n´veis de exposi¸cao ambiental e ocupacional ao merc´urio no atendimento odontol´ogico de consult´orios p´ublicos da cidade de Aragua´na em Tocantins (TO). Em colabora¸cao com este estudo, as amostras de urina dos indiv´duos expostos foram analisadas quanto ao teor de merc´urio total por espectrometria de absor¸cao atomica nas dependencias do laborat´orio de an´alises qu´micas do Centro de Qu´mica e Meio Ambiente (IPEN). Para isso, foi preciso selecionar uma metodologia anal´tica capaz de gerar resultados confi´aveis e valid´a-la antes de sua efetiva implanta¸cao. A valida¸cao anal´tica comprova, por meio de ensaios pr´aticos, que o laborat´orio tem condi¸coes de atender aos requisitos necess´arios para a aplica¸cao adequada do m´etodo. O desempenho do m´etodo foi avaliado quanto aos seguintes parametros: limite de detec¸cao e limite de quantifica¸cao, seletividade, sensibilidade, linearidade, exatidao e precisao. Os ensaios foram realizados com material de referencia certificado, o que assegura a rastreabilidade dos resultados. Os resultados obtidos comprovaram a adequabilidade do m´etodo ao prop´osito supracitado. A concentra¸cao de Hg encontrada para o material de referencia foi de (95,12 ± 11,70)g.L1 com uma recupera¸cao de 97%. A metodologia tamb´em foi aplicada `a amostras de urina de 39 indiv´duos, seis das quais (15%) apresentaram n´veis de merc´urio urin´ario superiores ao limite considerado normal (10g.L1). Os resultados obtidos encontram-se em uma faixa de concentra¸cao de 1,02 a 23,36g.L1. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
156

Desenvolvimento de um sistema calorimetrico para dosimetria de feixes de eletrons em processos por radiacao

BANADOS PEREZ, HOMERO E. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:17Z (GMT). No. of bitstreams: 1 05382.pdf: 3611357 bytes, checksum: aeefc0f052bf6399692f11e4b2ff1e2b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
157

Avaliacao dosimetrica da resposta espectrofotometrica da solucao gel de alanina para radiacao gama, de fotons de eletrons e de neutrons termicos / Dosimetric evaluation of spectrophotometric response of alanine gel solution for gamma, photons, electrons and thermal neutrons radiations

SILVA, CLEBER F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:10Z (GMT). No. of bitstreams: 0 / O dosímetro alanina gel é um novo material na forma de gel desenvolvido pelo IPEN, que apresenta uma melhora significativa em relação ao sistema a base de Alanina desenvolvido por Costa. A DL-Alanina (C3H7NO2) é um aminoácido tecido equivalente que favorece a produção de íons Férricos na solução. Este trabalho visa analisar as principais características dosimétricas deste novo material na forma de gel para futura aplicação na medida da distribuição da dose. Foi avaliado o desempenho da solução gel de Alanina para radiação gama, de fótons, de elétrons e de nêutrons térmicos utilizando a técnica de espectrofotometria. De acordo com os resultados obtidos para os diferentes tipos de radiação estudados, as reprodutibilidades intra e inter-lotes são melhores que 4% e 5%, respectivamente. A resposta em função da dose apresenta um comportamento linear para o intervalo de dose estudado. A dependência da resposta em função da taxa de dose e energia da radiação incidente é melhor que 2% e 3%, respectivamente. A dose mínima detectável é 0,1 Gy. Os resultados obtidos indicam que o dosímetro Alanina gel apresenta um bom desempenho, e pode ser usado como dosímetro alternativo na área de radioterapia, utilizando a técnica de ressonância magnética para avaliar a distribuição tridimensional de dose. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
158

Avaliacao dosimetrica da solucao fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

MANGUEIRA, THYAGO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:05Z (GMT). No. of bitstreams: 0 / Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
159

Determinação dos isótopos naturais de rádio de meias-vidas longas, Ra-226 e Ra-228, em águas minerais utilizadas nos Balneários de Caxambú (MG) e Águas de Lindóia (SP) / Determination of long-lived natural Ra isotopes, sup(226)Ra e sup(238)Ra, in mineral and spring waters from Caxambu (MG) and`Águas de Lindóia (SP) SPAS

NEGRAO, SERGIO G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:34Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:49Z (GMT). No. of bitstreams: 0 / Este trabalho teve por objetivos estudar a distribuição das concentrações de atividade dos isótopos de rádio de meias-vidas longas, 226Ra e 228Ra, em amostras de águas minerais coletadas no Balneário de Caxambu (MG) e no Balneário de Águas de Lindóia (SP). Foram observadas concentrações de atividade de 228Ra relativamente aumentadas em relação às de 226Ra nas águas minerais estudadas no Balneário de Caxambu. As concentrações elevadas de carbonatos e bicarbonatos destas águas podem resultar em um conseqüente aumento da solubilidade dos isótopos de Ra e pode ter um papel importante para a distribuição do 228Ra e para as reações de equilíbrio entre as fases sólida e líquida das soluções. No Balneário de Caxambu, as concentrações de atividade médias aritméticas variaram de 83 mBq L-1 a 3599 mBq L-1 e de 60 mBq L-1 a 4481 mBq L-1 para 226Ra e 228Ra, respectivamente. O maior valor de atividade de 226Ra foi observado nas águas da Fonte Venâncio, enquanto que a concentração máxima de 228Ra foi determinada na Fonte Ernestina Guedes. As razões de atividade 228Ra/ 226Ra variaram de 0,079 (Fonte Conde DEau e Princesa Isabel) a 4,2 (Fonte Mairink II). Em Águas de Lindóia as concentrações de atividade médias aritméticas variaram de 4,6 mBq L-1 a 41 mBq L-1 e de 30 mBq L-1 a 54 mBq L-1 para 226Ra e 228Ra, respectivamente. O maior valor de atividade de 226Ra foi observado nas águas da Fonte Engarrafada São Jorge, enquanto que a concentração máxima de 228Ra foi determinada na Fonte Santa Filomena (torneira pública 2). As razões de atividade 228Ra/ 226Ra variaram de 1,2 (Fonte Engarrafada São Jorge) a 9,1 (Fonte Engarrafada Jatobá 1). A exposição de indivíduos do público à radiação natural em virtude do consumo das águas minerais também foi avaliada neste trabalho. As doses efetivas foram estimadas utilizando-se um modelo dosimétrico conservativo, e integrando-se os resultados ao longo de 70 anos de vida de um indivíduo adulto, após a incorporação de 226Ra e 228Ra. Os resultados desta avaliação radiossanitária demonstraram que o nível de referência de dose efetiva comprometida recomendado pela Organização Mundial de Saúde de 0,1 mSv a-1 foi ultrapassado em quase todas as fontes de Caxambu, exceto para a Fonte Viotti, Fonte Dom Pedro e Fonte Dona Leopoldina. Em Águas de Lindóia e Lindóia as maiores doses efetivas comprometidas obtidas foram 8,4 10-3 mSv a-1 para o 226Ra (Fonte engarrafada São Jorge) e 2,6 10-2 mSv a-1 para o 228Ra (Fonte Santa Filomena torneira pública 2). Estes valores são menores que o limite recomendado pela Organização Mundial de Saúde. Doses efetivas comprometidas de até 7,4 x 10-1 mSv a-1 para o 226Ra (Fonte Venâncio, Caxambu) e 2,2 mSv a-1 para o 228Ra (Fonte Ernestina Guedes, Caxambu) foram estimadas no presente trabalho. No caso do 226Ra, este valor representa menos que 31% da dose efetiva média anual atribuída a radioatividade natural. Contudo, no caso do 228Ra, o limite anual de dose efetiva comprometida recomendado pela ICRP (considerando-se todas as fontes de exposição da população mundial à radiação) foi excedido não só na Fonte Ernestina Guedes, mas também na Fonte Beleza. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
160

Estudo do comportamento de um detector de radiação passivo para fins aeronáuticos utilizando o método Monte Carlo / Performance study of a passive radiation detector for aviation purpose using the Monte carlo method

MENCARINI, LEONARDO de H. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:36Z (GMT). No. of bitstreams: 0 / Profissionais da área aeronáutica, como pilotos e comissários de bordo, são submetidos a doses de radiação de origem cósmica, que podem ser maiores do que as doses médias dos trabalhadores da indústria nuclear. A diversidade de partículas de altas energias presentes no campo de radiação a bordo das aeronaves torna complexa a mensuração da dose e requer cuidados especiais em relação aos sistemas de dosimetria a serem empregados nesta área. A Força Aérea Brasileira, por meio de seu Instituto de Estudos Avançados (IEAv /DCTA), em conjunto com o Instituto de Pesquisas Energéticas e Nucleares (IPEN / CNEN -SP) vem estudando o assunto desde 2008. Um protótipo de detector de radiação passivo para medições em aeronaves foi previamente construído e testado em condições de voo e de laboratório. O detector é capaz de medir a grandeza dosimétrica conhecida como dose absorvida (usando dosímetros passivos), que serão posteriormente correlacionados ao equivalente de dose ambiente e à dose efetiva recebidos por profissionais da área aeronáutica. Neste contexto, uma abordagem teórica por meio de simulações Monte Carlo com os códigos computacionais MCNP5 e MCNPX, foi usada para modelar e caracterizar a resposta do detector em determinadas condições experimentais. Este trabalho apresenta os resultados preliminares da modelagem computacional, com ênfase especial na comparação entre a grandeza fundamental dose absorvida (mensurada e simulada) e sua relação com o equivalente de dose ambiente e dose efetiva para este detector. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1247 seconds