• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 990
  • 28
  • 27
  • 27
  • 27
  • 13
  • 12
  • 12
  • 12
  • 10
  • 5
  • 4
  • 4
  • 3
  • 2
  • Tagged with
  • 1016
  • 409
  • 178
  • 172
  • 156
  • 143
  • 141
  • 137
  • 132
  • 124
  • 121
  • 120
  • 114
  • 110
  • 98
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Comparação das razões lineares das vértebras cervicais por tomografia computadorizada de feixe cônico (TCFC) /

Mendonça, Tássia Mara Fernandes. January 2012 (has links)
Orientador: Luiz Cesar de Moraes / Co-orientador: Luiz Roberto Coutinho Manhães Junior / Banca: Mauro Pedrine Santamaria / Banca: Jorge Abrão / Resumo: Este estudo teve como objetivo avaliar possíveis diferenças das razões lineares da segunda e da terceira vértebras cervicais em cinco estágios do surto de crescimento puberal (SCP) avaliadas por tomografia computadorizada de feixe cônico (TCFC). Foram selecionados 26 exames de TCFC e as respectivas radiografias de mão e punho, de pacientes do sexo masculino e do feminino, com idades entre 8 e 18 anos e 11 meses. A amostra selecionada foi dividida em cinco grupos de acordo com os eventos de ossificação presentes nas radiografias de mão e punho, seguindo a curva de crescimento proposta por Martins e Sakima (1977), modificada por Mercadante (1996). Os exames tomográficos foram analisados por meio do próprio software do equipamento I-Cat® sob a extensão de arquivo "xstd". De posse do plano sagital ajustado ao protocolo de imagem foram realizadas, de forma objetiva, as mensurações das vértebras C2 e C3, por meio de onze pontos, a partir dos quais oito distâncias lineares foram obtidas. Baseados nestas, foram calculadas quatro razões, sendo uma de C2 e o restante de C3. Para verificar a existência de diferenças entre as razões obtidas para os cinco grupos da curva de crescimento, foi realizado o teste estatístico de análise de variância (Anova), fator único, associado ao teste de homogeneidade de Tukey para caracterizar cada fase do SCP. O nível de significância adotado foi de 95% para todas as análises. Verificou-se que o método é reprodutível (r2=0,994), sendo crescente as razões C2R, C3R e AL conforme as fases do SCP. Já para ASAP, observou-se aumento apenas nas fases 1, 3 e 5. De acordo com os resultados obtidos foi possível concluir que houve diferenças estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate possible differences of linear ratios of the second and third cervical vertebrae in five stages of pubertal growth spurt (PGS) evaluated by cone beam computed tomography (CBCT). A total of 26 CBCT scans and their hand and wrist radiographs of males and females, aged between 8 and 18 years and 11 months. The sample was divided into five groups according to the events of ossification present in the hand and wrist radiographs, following the curve of growth proposed by Martins and Sakima (1977), modified by Mercadante (1996). CT scans were analyzed using the software itself I-Cat ® equipment under the file extension "xstd." Having the sagittal image adjusted to the protocol were performed in an objective way, measurements of C2 and C3, by eleven points, from which eight linear distances were obtained. Based on these, four were calculated reasons, one of C2 and C3 of rest. To check for differences between the ratios obtained for the five groups of the growth curve was performed to test statistical analysis of variance (ANOVA) single factor associated with the Tukey's test of homogeneity to characterize each phase of the PGS. It was found that the method is reproducible (r2 = 0.994), with increasing ratios C2R, and AL C3R as phases of SCP. As for ASAP, growth observed only stages 1, 3 and 5. According to the results we conclude that statistically significant differences between the... (Complete abstract click electronic access below) / Mestre
202

Distúrbios funcionais da oclusão e sua correlação com radiografias transcranianas da articulação temporomandibular, em pacientes portadores de fissuras labiopalatais /

Takahashi, Fernando Eidi. January 1993 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Maria Cecilia Montagna Rosé / Banca: Marco Antonio Bottino / Foram avaliados 22 adultos portadores de fissuras labiopalatais, através de anamnese, exame clínico e radiografias transcranianas da articulação temporomandibular, com o intuito de observar a oclusão e correlacioná-la ccom os achados radiográficos. Os dados obtidos permitiram concluir que: 72,8% dos pacientes apresentavam, pelo menos, um sinal ou sintoma de disfunção craniomandibular (DCM); embora a condição oclusal se apresentasse severamente comprometida a maioria desses sinais ou sintomas era suave; a maior frequência dos sinais ou sintomas ocorreram no sexo feminino; na avaliação radiográfica, todos os pacientes assintomáticos apresentavam os dois côndilos com contorno normal, e todos os que apresentavam alteração de contorno, possuíam pelo menos um sinal ou sintoma de DCM; a posição centrada bilateral dos côndilos na fossa mandibular, não garante a ausência de sinais e sintomas de DCM; alguns pacientes com côndilos posicionados bilateralmente, para posterior ou, para caudal ou ainda, assimétricos, não apresentavam sinais ou sintomas de DCM; os achados radiográficos devem ser correlacionados com os achados clínicos; não foi observado um número significativo de pacientes com quadro clínico de DCM de origem oclusal / Anamnesis, clinical examinations and temporomandibular joint transcraneal radiographs for 22 adults with cleft lip and palate were carried out in order to evaluate the occlusion and correlate it with radographic findings. The conclusions were: 72.8% of the patients have at least one sign or symptom of craniomandibular disorders (CMD); although the occlusal conditions were severely altered, most of the signs and symptoms were classified as mild; the greater frequency of the signs and symptoms occurred among women; in the radiographic evaluation, all of the assymptomatic patients had both condyles with normal contour and all of the patients with altered contour had at least one sign or symptom; the bilateral centered position of the condyles in the fossa e did not warrant the absence of signs and symptoms; some patients with bilateral condyles positioned posteriorly or caudally or even assimetrically, did not present signs and symptoms of dysfunction; the radiographic findings should be correlated with clinical findings; and a great number of patients were not observed with clinical board of C:MD caused by the occlusion. Key words: Radiography; temporomandibular joint; temporomandibular joint syndrome; cleft palate; dental occlusion / Mestre
203

Desempenho de sistema de diagnóstico óptico para detecção de lesões de cárie /

Bussaneli, Diego Girotto. January 2013 (has links)
Orientador: Rita de Cássia Loiola Cordeiro / Banca: Lourdes Aparecida Martins dos Santos-Pinto / Banca: Silvio Issao Myaki / Resumo: O objetivo deste trabalho foi avaliar o desempenho de sistemas de diagnóstico óptico para detecção de lesões de cárie. No estudo in vitro, a viabilidade da transiluminação com laser infravermelho próximo (TI-NIR) para o diagnóstico de lesões iniciais de cárie foi avaliada. Dois examinadores avaliaram 94 sítios na superfície oclusal de molares e pré-molares humanos recém extraídos, classificados com escore 0, 1, 2 ou 3 ICDAS, utilizando um protótipo TI-NIR, a radiografia (RX), o DIAGNOdent Pen (DDPen) e o Quantitative Light-induced Fluorescence (QLF). Para validação, a análise histológica foi considerada como o padrão ouro. A reprodutibilidade intra e interexaminador foi avaliada com o coeficiente Kappa. Concluiu-se que o desempenho da TI-NIR bom, e constitui-se como uma alternativa válida e confiável para o diagnóstico de lesões iniciais na superfície oclusal de dentes permanentes. No segundo estudo, in vivo, o objetivo foi avaliar o desempenho do exame visual com os critérios Nyvad (EV), radiografia interproximal (RX), dispositivo de fluorescência a laser (DIAGNOdent Pen - DDPen) e suas associações no diagnóstico de lesões proximais em dentes decíduos. Para isso, foram selecionadas 45 crianças (n=59 superfícies) de ambos os sexos com idades entre 5 e 9 anos que apresentavam molares deciduos com sinais sugestivos da presença de lesão de cárie ou hígidos. As superfícies foram avaliadas clinicamente e codificadas segundo os critérios Nyvad, e logo depois com o DDPen. O exame radiográfico foi realizado apenas naquelas superfícies codificadas com os escores Nyvad 2, 3, 5 ou 6. Lesões de cárie ativas e/ou com superfície descontinuada foram restauradas, considerando-se a profundidade da lesão como padrão de referência. O desempenho do exame visual, radiográfico e DDpen e suas associações... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the performance of optical diagnostic systems for detection of caries lesions. In the in vitro study, the viability of the near infrared laser transillumination (TI-NIR) for diagnosis of incipient carious lesions was evaluated. Two examiners evaluated 94 sites in occlusal surface of molars and premolars freshly extracted, selected with score 0, 1, 2 or 3 ICDAS using the TI-NIR prototype, bitewing radiographs (RX), the DIAGNOdent Pen (DDPen) and Quantitative Light-induced Fluorescence (QLF). For validation, histological analysis was considered as the gold standard. The performance of TI-NIR was good, and its constitutes as a reliable and valid alternative for the diagnosis of early lesions in the occlusal surface of permanent teeth. In the second study, in vivo, the performance of the visual examination with the criteria Nyvad (EV), radiographs (RX), laser fluorescence device (DIAGNOdent Pen - DDPen) and their associations in the diagnosis of proximal lesions in deciduous teeth was evaluated. Were selected 45 children (n = 59 surfaces) of both sexes aged between 5 and 9 years who had deciduous molars with signs suggestive of the presence of caries or sound. The surfaces were evaluated clinically and scored with the Nyvad criteria, and DDPen. Radiographic examination was performed only on those surfaces scored with Nyvad 2, 3, 5 or 6. Caries active and / or discontinued surface were restored, considering the depth of the lesion as a reference standard. The performance of visual examination, and radiographic DDpen and their associations was good, but the use of the criteria NYVAD proved sufficient for the diagnosis of interproximal lesions. It could be observed that optical technologies appear to contribute positively in the diagnosis process in the diagnosis of caries. However, they should be considered as adjuncts to conventional methods in this process / Mestre
204

Técnicas automáticas para detecção de cordões de solda e defeitos de soldagem em imagens radiográficas industriais

Felisberto, Marcelo Kleber 10 2011 (has links)
Este trabalho propõe um novo método para a detecção automática de cordões de solda em imagens radiográficas de juntas soldadas de tubulações. A metodologia proposta baseia-se na otimização de parâmetros que controlam e adaptam o posicionamento, tamanho e formato de uma janela de imagem, de modo a enquadrar a região da imagem que mais se assemelha à representação visual de um cordão de solda radiografado. A busca por parâmetros ótimos é conduzida por um algoritmo genético, que parte de soluções aleatoriamente geradas e as avalia com base em um conceito de similaridade entre imagens, oriundo de técnicas de casamento de protótipos. Além de se tratar de uma proposta inédita, a solução apresentada cobre uma diversidade de situações, incluindo problemas de detecção do cordão de solda para os quais ainda não havia sido encontrada uma solução automatizada que a literatura tenha referenciado. Os resultados dos testes realizados alcançaram um desempenho entre 93 e 100%, para um total de 478 imagens consideradas, que incluem exemplos de praticamente todas as técnicas de exposição radiográfica recomendadas pelo código ASME V, para inspeção de juntas soldadas de tubulações. Entrementes, uma técnica já existente de segmentação de imagens foi adaptada para desempenhar a detecção automática de defeitos de soldagem. Para tais testes, foram utilizados padrões radiográficos das principais classes de defeitos, provenientes do International Institute of Welding (IIW). Após modificações agregadas à técnica de segmentação utilizada, foi possível detectar exemplos de todas as classes de defeitos testadas. Tais resultados contribuem para a análise automática de radiografias industriais e visa melhorar a qualidade e eficiência na inspeção radiográfica de soldas. / This work proposes a new method for the automatic detection of the weld seam in radiographic images of pipeline welded joints. The proposed methodology is based on the optimization of parameters that are used to control and modify the position, size and shape of an image window, in order to enclose the image region that best matches the radiographic representation of a reinforced weld seam. The search for the best matching is managed by a genetic algorithm and uses an image similarity concept that is commonly applied on template matching procedures. The proposed technique solved weld seam detection problems for which no other automatic detection method was successful. The test results achieved an accuracy between 93% and 100%, regarding different tests circumstances, for a total of 478 radiographic images. The images data set included radiograph samples that cover all the recommended radiographic exposure techniques that are recommended, in the ASME V code, for inspection of pipeline welded joints. Meanwhile, a known image segmentation technique was modified and applied to perform the automatic detection of welding defects. For that test series, radiographic patterns from the International Institute of Welding (IIW) were used, including samples of the most popular classes of welding defects. After the used segmentation technique has been properly modified, defect detection samples were achieved for all the tested defect classes. Such results contribute with advancements in the automatic analysis of industrial radiographs and, as a final goal, aim at aggregating quality and efficiency to the radiographic inspection of welded joints.
205

Mensuração dosimétrica e otimização imageológica de exames radiológicos na face infantil e adolescente

Köhler, Gerson Irandir 2010 October 1914 (has links)
O objetivo deste estudo foi avaliar a confiabilidade da imagem radiológica da hipertrofia adenoideana, em crianças e adolescentes, observada em telerradiografia lateral craniocervicofacial, verificando como torná-la mais eficaz tanto para utilização na área de Ortodontia e Ortopedia Facial quanto Otorrinolaringologia. Concomitantemente, foi efetuada uma pesquisa para aferição de dose de radiação na face, utilizando dosímetros termoluminiscentes (TLD-100). A confiabilidade da radiografia de cabeça e pescoço, em norma lateral, para visualização e diagnose do grau de hipertrofia da adenoideana foi efetuada através de uma análise inicial, por médicos otorrinolaringologistas, sobre sua preferência por qual de dois tipos de imagens: a radiografia convencional e cópia digitalizada e tratada computacionalmente pelo processo de inversão. Concluiu-se, pelos resultados deste trabalho, que: a) os profissionais médicos consultados têm uma preferência pelo recebimento não só da radiografia cefalométrica convencional, mas também da cópia digitalizada, que identifica com maior precisão a área de hipertrofia adenoideana presente; b) a dose de radiação sobre a face de crianças, resultante da tomada radiográfica do exame cefalométrico pode ser considerada de baixa intensidade, não representando, aparentemente, riscos futuros em função de suas qualidades estocásticas. / The objective of this study was to evaluate the reliability of radiological image from adenoidal hypertrophy in children and adolescents observed in lateral cranium-cervical-facial exposure and to verify how to make it more efficient in its utilization in Orthodontics and Facial Orthopedics and Otorhinolarynology areas. Parallel to this and considering the conflicting opinions observed in scientific literature about radiographic exams in growing patients, a research was conducted to verify the radiation dosage using thermoluminescent dosimeters (TLD-100). The reliability of head and neck radiography, in lateral norm, to visualization and diagnose of the degree of adenoidal hypertrophy was effectuated by an initial analysis of otorhinolarynologists about theirs preference between two types of images: conventional radiography and digitalized and treated copy by inversion process. Based on the results of this work, it was concluded that: a) consulted otorhinolarynologists prefer to receive not only conventional radiography but digitalized copy too, that allows the identification of adenoidal hypertrophy area more precisely; b) the radiation dosage in children’s face resulting from radiographic exposure of cephalometric exam can be considered of low intensity, and do not apparently represents future risks due to its stochastic characteristics.
206

Perda óssea marginal em implantes distais em próteses fixas implantossuportadas: desenvolvimento metodológico para estudo prospectivo radiográfico

Camargo, Bernardo Alievi January 2014 (has links)
Made available in DSpace on 2014-06-28T02:02:15Z (GMT). No. of bitstreams: 1 000458942-Texto+Completo-0.pdf: 1319347 bytes, checksum: 53009a393ff35022421155e36d99405d (MD5) Previous issue date: 2014 / Previous biomechanical studies show a great stress concentration at the distal region of implants adjacent to the cantilever in fixed implant-supported complete dentures (FISCD). Thus, it is necessary to evaluate the marginal bone levels in this region by means of intraoral radiographs. The objectives of this study were: 1) to develop a specific methodological approach for the radiographic evaluation of marginal bone loss (MBL) around the most distal implants adjacent to prosthetic cantilever in FISCD, 2) to investigate possible correlation between MBL, cantilever extension and mesio-distal inclination of the distal implants.Seven patients with 10 FICSD (n=20 implants) were accompanied during one year at the clinics of Faculty of Dentistry of PUCRS. Measurements of the cantilever extension of the metallic infrastructures were carried out during the prosthetic rehabilitation. The mesio-distal inclinations of the implants relative to the occlusal plane were defined through the cone beam computer tomography (CBCT). Intra-oral digital radiographs were obtained by customized positioning devices following delivery of the prostheses (baseline) and one year after the delivery. Cantilever extension, inclination and MBL of the distal implants were analyzed descriptively and inferentially: the correlation between MBL, cantilever extension and inclination of the implants were evaluated by Spearman‟s correlation coefficient with significance level of 5%.The mean values and their variability were; cantilever extension 9,80± 3,69 mm, distal inclination 2,50 (1,00; 10,50) degrees, mesial inclination -3,00(-5,00; -1,00) degrees, mesial MBL -0,08 (-0,28; 0,05) mm and distal MBL -0,04(-0,35; 0,09) mm. No statistical correlation was detected neither between MBL and cantilever extension nor between MBL and inclination of the distal implants. The proposed radiographic and methodological technique used in this study was reliable and reproducible. The findings of MBL after 1 year of follow-up were in accordance with the literature. / Estudos biomecânicos anteriores mostram que há uma maior concentração de forças na região distal dos implantes adjacentes ao cantilever protético em Próteses Totais Fixas Implantossuportadas (PTFIs), o que leva à necessidade de avaliação óssea periimplantar nessa região com radiografias intra-orais. Os objetivos deste trabalho foram o desenvolvimento de uma metodologia específica para avaliar radiograficamente a perda óssea linear em implantes mais distais, adjacentes ao cantilever protético em PTFIs e investigar sua possível correlação com extensão de cantilever e inclinação mésio-distal do implante.Foram acompanhados sete pacientes com 10 PTFIs (N=20 implantes) durante um ano, nas clínicas da Faculdade de Odontologia da PUCRS. A medição da extensão de cantilever protético na infraestrutura metálica foi realizada durante o tratamento. A inclinação mésio-distal dos implantes foi adquirida através de Tomografia computadorizada Cone Beam (CBCT) considerando o plano oclusal como referência. Foram realizadas radiografias intra-orais digitais, utilizando posicionadores customizados, após a entrega da prótese (baseline) e no acompanhamento de um ano. Extensão de cantilever, inclinação dos implantes e perda óssea foram analisados de forma descritiva e inferencial; a correlação entre perda óssea, extensão de cantilever e inclinação do implante foi efetuada com coeficiente de correlação de Spearman ao nível de significância de 5%.Os valores médios e sua variabilidade foram: extensão de cantilever 9,80± 3,69 mm, Inclinação Distal 2,50 (1,00; 10,50) graus, Inclinação Mesial -3,00 (-5,00; -1,00) graus e perda óssea M -0,08 (-0,28; 0,05) mm e perda óssea D -0,04 (-0,35; 0,09) mm. Não houve correlação estatística nem entre perda óssea marginal e extensão de cantilever protético nem entre perda óssea marginal inclinação dos implantes mais distais. Este trabalho demonstrou que a técnica de obtenção e análise das imagens radiográficas é confiável e reprodutível. Os achados de perda óssea em um ano estão de acordo com a literatura.
207

Técnicas automáticas para detecção de cordões de solda e defeitos de soldagem em imagens radiográficas industriais

Felisberto, Marcelo Kleber 10 2011 (has links)
Este trabalho propõe um novo método para a detecção automática de cordões de solda em imagens radiográficas de juntas soldadas de tubulações. A metodologia proposta baseia-se na otimização de parâmetros que controlam e adaptam o posicionamento, tamanho e formato de uma janela de imagem, de modo a enquadrar a região da imagem que mais se assemelha à representação visual de um cordão de solda radiografado. A busca por parâmetros ótimos é conduzida por um algoritmo genético, que parte de soluções aleatoriamente geradas e as avalia com base em um conceito de similaridade entre imagens, oriundo de técnicas de casamento de protótipos. Além de se tratar de uma proposta inédita, a solução apresentada cobre uma diversidade de situações, incluindo problemas de detecção do cordão de solda para os quais ainda não havia sido encontrada uma solução automatizada que a literatura tenha referenciado. Os resultados dos testes realizados alcançaram um desempenho entre 93 e 100%, para um total de 478 imagens consideradas, que incluem exemplos de praticamente todas as técnicas de exposição radiográfica recomendadas pelo código ASME V, para inspeção de juntas soldadas de tubulações. Entrementes, uma técnica já existente de segmentação de imagens foi adaptada para desempenhar a detecção automática de defeitos de soldagem. Para tais testes, foram utilizados padrões radiográficos das principais classes de defeitos, provenientes do International Institute of Welding (IIW). Após modificações agregadas à técnica de segmentação utilizada, foi possível detectar exemplos de todas as classes de defeitos testadas. Tais resultados contribuem para a análise automática de radiografias industriais e visa melhorar a qualidade e eficiência na inspeção radiográfica de soldas. / This work proposes a new method for the automatic detection of the weld seam in radiographic images of pipeline welded joints. The proposed methodology is based on the optimization of parameters that are used to control and modify the position, size and shape of an image window, in order to enclose the image region that best matches the radiographic representation of a reinforced weld seam. The search for the best matching is managed by a genetic algorithm and uses an image similarity concept that is commonly applied on template matching procedures. The proposed technique solved weld seam detection problems for which no other automatic detection method was successful. The test results achieved an accuracy between 93% and 100%, regarding different tests circumstances, for a total of 478 radiographic images. The images data set included radiograph samples that cover all the recommended radiographic exposure techniques that are recommended, in the ASME V code, for inspection of pipeline welded joints. Meanwhile, a known image segmentation technique was modified and applied to perform the automatic detection of welding defects. For that test series, radiographic patterns from the International Institute of Welding (IIW) were used, including samples of the most popular classes of welding defects. After the used segmentation technique has been properly modified, defect detection samples were achieved for all the tested defect classes. Such results contribute with advancements in the automatic analysis of industrial radiographs and, as a final goal, aim at aggregating quality and efficiency to the radiographic inspection of welded joints.
208

Análise morfológica das fissuras labiopalatinas pré-forame incisivo unilaterais completas por meio de radiografias oclusal, panorâmica e tomografia computadorizada de feixe cônico

Ibrahim, Danilo January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:04Z (GMT). No. of bitstreams: 2 000433314-0.pdf: 13348285 bytes, checksum: 296922c6bbfb2bfda4afb8b10ce67c52 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The present study assessed oral clefts and their adjacent anatomical structures by means of occlusal and panoramic radiography and the cone beam computed tomography (CBCT) technique, with a descriptive analysis design, using linear and volumetric measurements. The study sample comprised 12 patients with complete unilateral pre-incisive foramen clefts treated at the Hospital de Reabilitação de Anomalias Craniofaciais (Universidade de São Paulo, Bauru). Films and scans were manipulated by software packages. Cleft area was calculated with each diagnostic modality, and cleft volume, by CBCT. Measurements were obtained from axial CBCT slices, 3 mm and 6 mm above the cementoenamel junction and at the level of the apex, for assessment of the thickness of the alveolar ridge adjacents to the cleft. Four measurements were obtained from the panoramic CBCTs for measurement of the length of cleft-adjacent roots and alveolar ridges. The results showed that CBCT was significantly superior to occlusal and panoramic radiographs for measurement of cleft area, with mean measured values of 803 mm2, 40. 36 mm2, and 50. 84mm2 respectively (p≤0,05, Student's t test), and 889. 9 mm3 for volume measurement. Mean root length of the teeth mesial and distal to the cleft was 9. 91 mm and 10. 56 mm respectively, and mean bony coverage of the roots, 73. 73% and 86. 38% respectively. We conclude that CBCT was able to reveal a significantly larger bone defect area than occlusal or panoramic radiographs; allowed measurement of root and bony ridge lengths in the areas adjacent to clefts, as well as more accurate measurement of bone thickness around the roots of teeth, enabling improved planning of the amount of bone required for secondary alveolar bone grafting procedures; and provided clearer, more faithful reproductions of the details of the cleft area, with no overlap of anatomical structures. / A presente pesquisa avaliou as fissuras e as estruturas anatômicas adjacentes através das técnicas radiográficas oclusal e panorâmica e da tomografia computadorizada de feixe cônico (TCFC) por meio de uma análise descritiva e de mensurações lineares e volumétrica. Participaram do estudo 12 pacientes portadores de fissuras pré-forame incisivo unilaterais completas em tratamento no Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo – Bauru/SP. As imagens radiográficas e tomográficas foram manipuladas por softwares. As áreas das fissuras foram calculadas nas três modalidades diagnósticas e o volume na TCFC; foram realizadas medidas axiais nas tomografias nas alturas de 3mm e 6mm acima da junção cemento-esmalte e ao nível dos ápices dentários para análise das espessuras das cristas ósseas adjacentes às fissuras; quatro medidas na vista panorâmica das TCFCs para medição do comprimento das raízes e das cristas alveolares adjacentes às fissuras. Os resultados mostraram a superioridade da TCFC em relação as radiografias oclusal e panorâmica na determinação das áreas das fissuras com valores médios de 803mm2, 40,36mm2, 50,84mm2, respectivamente, apresentando diferença estatisticamente significativa (teste t-student, p≤0,05), e 889,9mm3 para as medidas de volume. Os dentes mesiais e distais aos defeitos apresentaram médias do comprimento radicular de 9,91mm e 10,56mm e da cobertura óssea radicular de 73,73% e 86,38%, respectivamente. Concluiu-se que a TCFC revelou um defeito ósseo significativamente maior que os observadas nas radiografias oclusal e panorâmica; possibilitou a mensuração da extensão das raízes dos dentes e suas respectivas cristas ósseas adjacentes às fissuras; permitiu a mensuração da espessura óssea ao redor das raízes dos dentes, possibilitando melhor planejamento da quantidade óssea a ser utilizada nas cirurgias de Enxerto Ósseo Alveolar Secundário; e reproduziu os detalhes da região da fissura com maior nitidez sem sobreposição das estruturas anatômicas.
209

Avaliação de medidas cefalométricas em imagens obtidas a partir da telerradiografia de perfil e da tomografia computadorizada cone beam

Onofre, Niége Michelle Lazzari de January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-06-24T11:17:14Z No. of bitstreams: 1 448831.pdf: 2262038 bytes, checksum: e6e9df4e4402b737ba70c7259409f857 (MD5) / Made available in DSpace on 2013-06-24T11:17:14Z (GMT). No. of bitstreams: 1 448831.pdf: 2262038 bytes, checksum: e6e9df4e4402b737ba70c7259409f857 (MD5) / Introdução: o objetivo deste estudo foi avaliar se as medidas cefalométricas obtidas no cefalograma a partir da imagem da radiografia lateral da cabeça (RLC) são reprodutíveis e comparáveis com as medidas obtidas no cefalograma realizado na imagem gerada a partir da tomografia computadorizada cone beam (TCCB). Dessa forma, determinar a aplicabilidade da TCCB para a análise cefalométrica comumente utilizada na ortodontia. / Metodologia: foram selecionados 20 pacientes que possuíam tanto RLC quanto TCCB da cabeça. Para a realização das medidas foi utilizado o software Radiocef Studio 2 (RadioMemory Ltda., Belo Horizonte, MG, Brasil). Estas foram realizadas por três avaliadores com diferentes níveis de experiência. Cada avaliador determinou as medidas nas imagens obtidas da RLC e nas obtidas a partir da TCCB (T1) e estas foram repetidas num intervalo de tempo de uma semana (T2). Para determinar a reprodutibilidade intra-avaliadores e interavaliadores foi utilizado o Coeficiente de Correlação Intraclasse (ICC). Para análise dos valores obtidos com os dois métodos tanto em T1 quanto em T2 foi utilizado o Teste t-student. O Teste não-paramétrico de Friedman foi aplicado para comparar as medidas dos três avaliadores. O nível de significância máximo assumido foi de 5% (p≤0,05). / Resultados: o ICC para os 3 avaliadores foi acima de 0.8 para os dois métodos e para todas as medidas cefalométricas com exceção da medida Nperp-Pog para o Avaliador 2 (ICC=0.66). As medidas Co-A, Co-Gn e ENA-Me apresentaram diferenças estatísticamente e clinicamente significantes entre os dois métodos, diferenças de 5,59 mm, 8,2 mm e de 5,9 mm, respectivamente. Diferenças também foram observadas para medidas NPerp-Pog, com variação de 1,17 mm e para a medida EixoY, com variação de 0,68º. / Conclusões: os dois métodos apresentaram boa reprodutibilidade. Foram observadas diferenças estatísticamente significantes para metade das 10 medidas cefalométricas avaliadas. A comparação de medidas cefalométricas, seguindo o delineamento do presente estudo, não mostrou similaridade entre os dois métodos avaliados. / Introduction: The aim of this study was to evaluate the reproducibility and to compare the cephalometric measurements in images from conventional lateral radiographs (CLR) and in images synthesized from cone beam computed tomography (CBCT). / Methodology: Twenty patients who had both a CBCT and a conventional lateral radiograph were recruited. Three observers digitized landmarks used for 10 measurements in CBCT images and in CLR from all patients at two different times (T1 and T2). The cephalometric analyses were conducted on the Radiocef Studio 2 software (RadioMemory Ltda., Belo Horizonte, MG, Brazil). In order to asses the reproducibility of exams in each technique, the ICC was calculatedd for each cephalometric measurement in each of techniques investigated. Differences between the modalities in T1 and T2 were calculated used t-student test. To compare the measurements from the three observers, Friedman test was used. Statistical significance was defined as 5% (p≤0,05). / Results: the ICC of all measurements were above 0.8 in both methods, except for Nperp-Pog (ICC=0.66) for the Observer 2. There were statiscally and clinicaly differences for the Co-A (5,59 mm), Co-Gn (8,2 mm) and ENA-Me (5,9 mm) measurements between the methods. Differences were also found for NPerp-Pog (1,17 mm) and EixoY (0,68º). / Conclusion: the reproducibility was good for all the measurements in both methods. The significant differences between the modalities were shown in 5 of the 10 measurements analized in this study. Measurements from CBCT synthesized cephalograms are not similar to those based on conventional radiographic images.
210

Análise morfológica das estruturas anatômicas da região anterior de maxila e suas variações avaliadas por meio de imagens tomográficas de feixe cônico

Velho, Fernando Mathias Teixeira January 2016 (has links)
Introdução: A reconstrução e avaliação tridimensional das estruturas ósseas do crânio por meio da Tomografia Computadorizada de Feixe Cônico (TCFC) abriu a possibilidade para uma melhor investigação dos acidentes anatômicos presentes na região de interesse do cirurgião-dentista. A TCFC representa o padrão-ouro no quesito qualidade e fidelidade de seus cortes, possibilitando maior clareza na detecção das alterações morfológicas de tecidos duros e elementos dentários observadas em imagens tomográficas. Objetivo: Investigar as variações anatômicas e morfológicas encontradas nas fossas nasais, canal nasopalatino (com medições de comprimento, espessura e dos diâmetros do forame incisivo e foramina de Stenson), canalis sinuosus e foraminas acessórias por meio de exames tomográficos de feixe cônico relacionando com gênero, idade e presença ou ausência dentária na região anterior da maxila. Material e Métodos: Após a aplicação dos critérios de exclusão, as estruturas acima foram analisadas em 1.143 exames de TCFC, de 628 mulheres e 515 homens, por três examinadores treinados e calibrados, especialistas em Radiologia Odontológica e Imaginologia. Os dados finais foram avaliados de forma descritiva com a utilização de porcentagem e frequência dos achados em relação à amostra. A correlação dos dados foi realizada através do Test t, ANOVA, Kruskal-Wallis, Tukey, Testes Qui-Quadrados exatos de Fisher e de Pearson isolando as variáveis de gênero, idade e presença ou ausência dentária (significância de 0,5%). / Introduction: The reconstruction and tridimensional evaluation of bone skull structures through Cone Beam Computed Tomography (TCFC) opened the possibility for a better inquiry of the anatomic accidents present in the interest region of the dentist-surgeon. The TCFC represent the gold-pattern in the quality question and fidelity of its cuts, enabling greater clarity on morphological alterations detection observed in tomographic images. Objective: Investigate the anatomic variations found in nasal fossae, nasopalatine canal (with measures of length, thickness and diameter of the incisor foramen and Stenson's foramina), canalis sinuosus and acessory foramina by means of CBCT, relating with gender, age and presence or absence of teeth in the anterior region of the maxila. Material and methods: After applying the exclusion criteria, the above strcutures were analysed in 1.143 TCFC exams, of 628 female and 515 male, by three trained and calibrated examiners, specialized in Dental Radiology. The final data were evaluated in descriptive way using percentage and frequency of the findings related to the sample. The correlation of the data was carried out using t test , ANOVA, Kruskal-Wallis, Tukey, and Fisher's and Pearson's exact Chi-Square tests, isolating the variables of gender, age and dental presence or absence (0.5% significance).

Page generated in 0.1105 seconds