• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The use of scintigraphy to study gastric emptying, motility and small intestinal transit in patients who have ingested a selection of common poisons

Adams, Bruce Keith January 1995 (has links)
Poisoning is common and carries considerable morbidity and mortality. Two to three patients are admitted to the Emergency Unit at Groote Schuur Hospital every day with drug overdose. As absorption occurs in the small intestine the rates at which ingested poisons pass into and through the small bowel are important factors in determining the amount of poison potentially available for absorption. Although the effects of pharmacological doses of many drugs on gastric emptying and motility are known, information on the effects of higher doses is limited. I investigated patients who took overdoses of certain commonly used drugs to determine their effects on gastric emptying and motility and small intestinal transit. The study was divided into two parts. One hundred and four patients were studied in Part 1. These patients took overdoses of tricyclic antidepressants (n = 31), carbamazepine (n = 15), phenytoin (n = 12), paracetamol (n = 29) and opioid-paracetamol mixtures (n = 17). They received standard hospital management of which sorbitol was not a part. Part 2 consisted of sixty-one patients who had sorbitol added to their treatment. These patients had taken overdoses of the tricyclic antidepressants (n = 15), carbamazepine (n = 7), phenytoin (n = 8), paracetamol (n = 13) and opioid-paracetamol mixtures (n = 18). The effects of sorbitol on gastric emptying and small intestinal transit were evaluated. A third study-the paracetamol control test was done on 5 healthy volunteers. Each subject was studied twice; the first time after taking 1 G of paracetamol and the second time after no drug ingestion.
2

The diagnostic accuracy to Technetium 99m labelled erythrocyte scintigraphy in the investigation of hepatic mass lesions : special reference to hepatic cavernous haemangioma and hepatocellular carcinoma

Lourens, Steven January 1995 (has links)
The distinction between cavernous haemangiomas of the liver (which are the second most common hepatic mass lesions) from malignant lesions, is often difficult. An incorrect diagnosis of cavernous haemangioma, in a patient with malignancy, may adversely influence the outcome of subsequent treatment in these patients, due to delay in therapy. Although previous studies have suggested that ⁹⁹ᵐTc erythrocyte blood pool scintigraphy is both highly sensitive and specific for haemangiomas, a basic flaw in all previous studies has been the small number of control patients studied. Bayesian analysis clearly shows that specificity for a test is dependant on the pre-test probability of the lesion being present. Thus all the studies done to date, may reflect an inappropriately high specificity for ⁹⁹ᵐTc scintigraphy, in diagnosing cavernous haemangiomas, because they have mainly studied patients with haemangiomas and relatively few patients with other lesions. This study was thus undertaken to clarify the true accuracy of this technique, in distinguishing haemangiomas from other hepatic mass lesions, by studying a large number of patients with haemangiomas and other hepatic mass lesions.
3

Use of a Technetium99m-Sestamibi Scan to Detect Ipsilateral Double Adenoma in a Patient With Primary Hyperparathyroidism: A Case Report

Gabriel, Joseph G., Contreras, Alejandro, Rosenthal, Andrew 01 January 2017 (has links)
INTRODUCTION: Patients with primary hyperparathyroidism generally have a single parathyroid adenoma that causes excessive excretion of parathyroid hormone. For about 2% to 15% of these patients, a double adenoma is present that involves one lesion on each side of the neck. CASE PRESENTATION: We describe a case of double parathyroid adenoma causing asymptomatic hypercalcemia. A presurgical technetium99m (Tc99m) sestamibi scan suggested an ipsilateral double adenoma in the left thyroid lobe. An intraoperative parathyroid hormone assay confirmed its successful removal. DISCUSSION: Although double adenomas are not yet widely acknowledged, presurgical imaging and nuclear scans can help to localize multiple lesions, and intraoperative parathyroid hormone assays can confirm the diagnosis and cure.
4

Considerações referentes à influência do posicionamento dos membros superiores sobre o resultado da cintilografia de perfusão do miocárdio / Considerations about the influence of upper arms positioning on myocardial perfusion scintigraphy results

Izaki, Marisa 01 August 2008 (has links)
I NTRODUÇÃO: Na cintilografia de perfusão do miocárdio, contrariamente ao desenvolvimento tecnológico ao longo do tempo, manteve-se desde o princípio a mesma forma, por vezes desconfortável ou mesmo inviável, de posicionamento na aquisição das imagens: decúbito dorsal com os braços elevados. OBJETIVOS: O objetivo da pesquisa foi o de avaliar se na aquisição da cintilografia de perfusão do miocárdio o posicionamento com os membros superiores abaixados(T) apresenta os mesmos resultados que os obtidos com os membros superiores elevados(C), tanto em termos de alterações perfusionais como em relação aos parâmetros funcionais. . MÉTODOS: Foram estudados 120 pacientes, 83 (69%) do sexo masculino, com idade 59,4 ± 11,4 anos e peso 72,8 ± 14 kg. Foi realizada primeiramente a aquisição C e na seqüência a aquisição T, utilizando protocolo de um dia de repouso-estresse (dose 370 MBq e 1110 MBq de sestamibi-99mTc), com estresse sincronizado ao eletrocardiograma (gated- SPECT). Três modelos distintos de equipamentos de dois detectores foram utilizados no estudo. Os estudos foram processados usando reconstrução iterativa (OSEM). Na interpretação foi utilizado o modelo de segmentação miocárdica de 17 segmentos, pontuados de 0 a 4 (normal a ausente) segundo o grau de captação. Baseada na análise de um observador dentre um grupo de sete, foi realizada a comparação da totalidade dos segmentos e também segmento a segmento das aquisições C e T nas etapas de estresse e de repouso. Foi comparada também a somatória das pontuações das etapas de estresse(SSS) e repouso(SRS). Os pacientes foram divididos segundo dois critérios: primeiramente, normais (SSS=0) e anormais (SSS>1) e posteriormente, em de baixo risco (SSS3) e de maior risco (SSS>3) A comparação dos parâmetros funcionais de fração de ejeção do ventrículo esquerdo (FEVE), volume diastólico final (VDF), volume sistólico final(VSF), somatória dos escores de motilidade (SMS) e somatória dos escores de espessamento (STS) foi baseada nos valores obtidos de modo automático utilizando o programa computacional Quantitative Gated SPECT. RESULTADOS: No modo C, 23,3% dos pts referiram algum grau de dor no membro superior ou no ombro e no modo T 5 %. Houve diferença significativa (p<0,05) na comparação dos 2040 segmentos miocárdicos entre C e T, ao estresse e ao repouso. Nos 63 pts normais não houve diferença significativa dos escores entre C e T ao estresse e ao repouso. O mesmo foi observado nos 80 pts de baixo risco. Nos 57 pts anormais houve boa correlação entre os valores de SSS (Rho=0,93, p=0,0001) e SRS (Rho=0,93, p=0,0001), mas com valores não equivalentes (p<0,05), sendo a média dos valores de SSS (9,28±8,10) e SRS (7,89±7,34) da aquisição T inferiores à média dos valores de SSS (10,07±7,71) e SRS (8,46±7,35) encontrada na aquisição C. Nos 40 pts de risco, houve boa correlação dos valores de SSS(Rho=0,95, p=0,0001) e SRS(Rho=0,96 p=0,0001), porém a média dos valores de SSS (12,53±7,54) e SRS (10,60±7,08) da aquisição T foi significantemente (p<0,05) inferior à média dos valores de SSS (13,43±6,81) e SRS(11,33±6,97) encontrados na aquisição C. Os parâmetros funcionais apresentaram boa correlação entre C e T, exceto o VDF(p=0,0001). CONCLUSÕES: Os modos C e T apresentam boa correlação dos parâmetros funcionais, exceto o VDF. Embora a aquisição T tenha sido um pouco mais confortável e tenha demonstrado boa correlação nos achados perfusionais, em pts anormais e de maior risco há tendência à subestimação dos defeitos perfusionais. Considerando a importância da medida precisa da intensidade e extensão das alterações perfusionais em termos de avaliação prognostica e decisão terapêutica, a aquisição com membro superior abaixado deve ser evitada. Em situações onde a aquisição com membros superiores abaixados é a única alternativa, os resultados da cintilografia devem ser interpretados com cuidado, especialmente em pacientes anormais e de maior risco, onde as alterações podem estar subestimadas / Contrary to the advances in imaging technology for nuclear cardiology applications, we keep using the same often uncomfortable and sometimes impracticable patient position- supine with arms raised above the head (C). We tested another position modality: supine with arms down at the sides of the trunk (T). The purpose of this study was to verify if the functional and perfusion results of the acquisition T are equivalent to those of the acquisition mode C. We studied 120 patients (pts), 83 (69%) male, aged 59.4±11.4 years and weighting 72.8±14 kg. We performed a one-day protocol (rest gated/stress), using 99mTc-sestamibi (370 MBq and 1110 MBq). In both times (rest and stress), we first performed acquisition in C and in sequence the acquisition in T. The studies were performed in three types of dual detector SPECT systems. T mode was executed successfully in all pts. Images were processed by the iterative reconstruction method (OSEM). Each study was independently interpreted by one nuclear medicine specialist from a group of seven physicians using the 17-segment model. The segments were scored using a 5-point model ranging from 0 (normal uptake) to 4 (uptake absent). The total score of the left ventricle at stress is referred to as the summed stress score (SSS) and at rest as the summed rest score (SRS). The patients were categorized in subgroups by two criteria: normal (SSS=0) or abnormal (SSS1) and low risk (SSS3) or risk (SSS>3). The values of the functional parameters of left ventricular ejection fraction (LVEF), end diastolic volume (EDV), end systolic volume (ESV), stress motion score (SMS) and stress thickening score (STS) for both C and T were automatically obtained by the quantitative gated SPECT (QGS) program and results were compared. Shoulder and/or back pain occurred in 23.3% of C patients and in 5% of T patients. There was no agreement between the 2040 segmental scores of both rest and stress in C and T modes (p<0.05). No significant differences between C and T were found for SSS and SRS in the 63 normal individuals nor in the 80 low risk patients. Good correlation between C and T was found for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001) in the 57 abnormal pts, but the mean SSS (9.28±8.10) and SRS (7.89±7.34) values of T were significantly lower (p<0.05) than the mean for SSS (10.07±7,71) and SRS(8.46±7,35) of C mode. Similar patterns were observed in the 40 risk pts; good correlation was found between C and T modes for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001), but the mean SSS (12.53±7.54) and SRS (10.60±7.08) values of T were significantly lower (p<0.05) than SSS (13.43±6.81) and SRS (11.33±6.97) of C mode. Good correlation between C and T was found for all functional parameters, except for EDV (p=0.0001). Although T mode appears to be more comfortable and presented a good correlation between SSS and SRS values, in abnormal and risk pts, the extent and severity of defects can be underestimated. Considering the important therapeutic and prognostic implications of an accurate perfusion measurement, the cardiac SPECT acquisition with the arms in down position should be avoided. When arms-down acquisition is the only alternative, scintigraphy results must be carefully interpreted, especially in abnormal scans whereas the amount of perfusion abnormalities can be underestimated.
5

Considerações referentes à influência do posicionamento dos membros superiores sobre o resultado da cintilografia de perfusão do miocárdio / Considerations about the influence of upper arms positioning on myocardial perfusion scintigraphy results

Marisa Izaki 01 August 2008 (has links)
I NTRODUÇÃO: Na cintilografia de perfusão do miocárdio, contrariamente ao desenvolvimento tecnológico ao longo do tempo, manteve-se desde o princípio a mesma forma, por vezes desconfortável ou mesmo inviável, de posicionamento na aquisição das imagens: decúbito dorsal com os braços elevados. OBJETIVOS: O objetivo da pesquisa foi o de avaliar se na aquisição da cintilografia de perfusão do miocárdio o posicionamento com os membros superiores abaixados(T) apresenta os mesmos resultados que os obtidos com os membros superiores elevados(C), tanto em termos de alterações perfusionais como em relação aos parâmetros funcionais. . MÉTODOS: Foram estudados 120 pacientes, 83 (69%) do sexo masculino, com idade 59,4 ± 11,4 anos e peso 72,8 ± 14 kg. Foi realizada primeiramente a aquisição C e na seqüência a aquisição T, utilizando protocolo de um dia de repouso-estresse (dose 370 MBq e 1110 MBq de sestamibi-99mTc), com estresse sincronizado ao eletrocardiograma (gated- SPECT). Três modelos distintos de equipamentos de dois detectores foram utilizados no estudo. Os estudos foram processados usando reconstrução iterativa (OSEM). Na interpretação foi utilizado o modelo de segmentação miocárdica de 17 segmentos, pontuados de 0 a 4 (normal a ausente) segundo o grau de captação. Baseada na análise de um observador dentre um grupo de sete, foi realizada a comparação da totalidade dos segmentos e também segmento a segmento das aquisições C e T nas etapas de estresse e de repouso. Foi comparada também a somatória das pontuações das etapas de estresse(SSS) e repouso(SRS). Os pacientes foram divididos segundo dois critérios: primeiramente, normais (SSS=0) e anormais (SSS>1) e posteriormente, em de baixo risco (SSS3) e de maior risco (SSS>3) A comparação dos parâmetros funcionais de fração de ejeção do ventrículo esquerdo (FEVE), volume diastólico final (VDF), volume sistólico final(VSF), somatória dos escores de motilidade (SMS) e somatória dos escores de espessamento (STS) foi baseada nos valores obtidos de modo automático utilizando o programa computacional Quantitative Gated SPECT. RESULTADOS: No modo C, 23,3% dos pts referiram algum grau de dor no membro superior ou no ombro e no modo T 5 %. Houve diferença significativa (p<0,05) na comparação dos 2040 segmentos miocárdicos entre C e T, ao estresse e ao repouso. Nos 63 pts normais não houve diferença significativa dos escores entre C e T ao estresse e ao repouso. O mesmo foi observado nos 80 pts de baixo risco. Nos 57 pts anormais houve boa correlação entre os valores de SSS (Rho=0,93, p=0,0001) e SRS (Rho=0,93, p=0,0001), mas com valores não equivalentes (p<0,05), sendo a média dos valores de SSS (9,28±8,10) e SRS (7,89±7,34) da aquisição T inferiores à média dos valores de SSS (10,07±7,71) e SRS (8,46±7,35) encontrada na aquisição C. Nos 40 pts de risco, houve boa correlação dos valores de SSS(Rho=0,95, p=0,0001) e SRS(Rho=0,96 p=0,0001), porém a média dos valores de SSS (12,53±7,54) e SRS (10,60±7,08) da aquisição T foi significantemente (p<0,05) inferior à média dos valores de SSS (13,43±6,81) e SRS(11,33±6,97) encontrados na aquisição C. Os parâmetros funcionais apresentaram boa correlação entre C e T, exceto o VDF(p=0,0001). CONCLUSÕES: Os modos C e T apresentam boa correlação dos parâmetros funcionais, exceto o VDF. Embora a aquisição T tenha sido um pouco mais confortável e tenha demonstrado boa correlação nos achados perfusionais, em pts anormais e de maior risco há tendência à subestimação dos defeitos perfusionais. Considerando a importância da medida precisa da intensidade e extensão das alterações perfusionais em termos de avaliação prognostica e decisão terapêutica, a aquisição com membro superior abaixado deve ser evitada. Em situações onde a aquisição com membros superiores abaixados é a única alternativa, os resultados da cintilografia devem ser interpretados com cuidado, especialmente em pacientes anormais e de maior risco, onde as alterações podem estar subestimadas / Contrary to the advances in imaging technology for nuclear cardiology applications, we keep using the same often uncomfortable and sometimes impracticable patient position- supine with arms raised above the head (C). We tested another position modality: supine with arms down at the sides of the trunk (T). The purpose of this study was to verify if the functional and perfusion results of the acquisition T are equivalent to those of the acquisition mode C. We studied 120 patients (pts), 83 (69%) male, aged 59.4±11.4 years and weighting 72.8±14 kg. We performed a one-day protocol (rest gated/stress), using 99mTc-sestamibi (370 MBq and 1110 MBq). In both times (rest and stress), we first performed acquisition in C and in sequence the acquisition in T. The studies were performed in three types of dual detector SPECT systems. T mode was executed successfully in all pts. Images were processed by the iterative reconstruction method (OSEM). Each study was independently interpreted by one nuclear medicine specialist from a group of seven physicians using the 17-segment model. The segments were scored using a 5-point model ranging from 0 (normal uptake) to 4 (uptake absent). The total score of the left ventricle at stress is referred to as the summed stress score (SSS) and at rest as the summed rest score (SRS). The patients were categorized in subgroups by two criteria: normal (SSS=0) or abnormal (SSS1) and low risk (SSS3) or risk (SSS>3). The values of the functional parameters of left ventricular ejection fraction (LVEF), end diastolic volume (EDV), end systolic volume (ESV), stress motion score (SMS) and stress thickening score (STS) for both C and T were automatically obtained by the quantitative gated SPECT (QGS) program and results were compared. Shoulder and/or back pain occurred in 23.3% of C patients and in 5% of T patients. There was no agreement between the 2040 segmental scores of both rest and stress in C and T modes (p<0.05). No significant differences between C and T were found for SSS and SRS in the 63 normal individuals nor in the 80 low risk patients. Good correlation between C and T was found for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001) in the 57 abnormal pts, but the mean SSS (9.28±8.10) and SRS (7.89±7.34) values of T were significantly lower (p<0.05) than the mean for SSS (10.07±7,71) and SRS(8.46±7,35) of C mode. Similar patterns were observed in the 40 risk pts; good correlation was found between C and T modes for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001), but the mean SSS (12.53±7.54) and SRS (10.60±7.08) values of T were significantly lower (p<0.05) than SSS (13.43±6.81) and SRS (11.33±6.97) of C mode. Good correlation between C and T was found for all functional parameters, except for EDV (p=0.0001). Although T mode appears to be more comfortable and presented a good correlation between SSS and SRS values, in abnormal and risk pts, the extent and severity of defects can be underestimated. Considering the important therapeutic and prognostic implications of an accurate perfusion measurement, the cardiac SPECT acquisition with the arms in down position should be avoided. When arms-down acquisition is the only alternative, scintigraphy results must be carefully interpreted, especially in abnormal scans whereas the amount of perfusion abnormalities can be underestimated.

Page generated in 0.1151 seconds