• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 41
  • 41
  • 27
  • 14
  • 7
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Synthesis of a hybrid digital/analog symbol generator for cathode ray tube display

Sobocinski, Richard Steven, January 1968 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1968. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
12

An environmental systems analysis of cathode ray tube waste management

Lundy, Chancee'. Chan-Hilton, Amy B. January 2006 (has links)
Thesis (M.S.)--Florida State University, 2006. / Advisor: Amy B. Chan-Hilton, Florida State University, College of Engineering, Dept. of Civil and Environmental Engineering. Title and description from dissertation home page (viewed Sept. 18, 2006). Document formatted into pages; contains xiii, 116 pages. Includes bibliographical references.
13

The interactive generation of facial images on a CRT using a heuristic strategy /

Gillenson, Mark Lee January 1974 (has links)
No description available.
14

A study of the persistence characteristics of various cathode ray tube phosphors

January 1948 (has links)
W.T. Dyall. / "January 16, 1948." Based on a thesis submitted to M.I.T. Dept. of Physics, 1948. / Bibliography: p. 102-104. / Army Signal Corps Contract No. W-36-039 sc-32037.
15

Realization of radiobiological in vitro cell experiments at conventional X-ray tubes and unconventional radiation sources

Beyreuther, Elke 24 November 2010 (has links) (PDF)
More than hundred years after the discovery of X-rays different kinds of ionizing radiation are ubiquitous in medicine, applied to clinical diagnostics and cancer treatment as well. Irrespective of their nature, the widespread application of radiation implies its precise dosimetric characterization and detailed knowledge of the radiobiological effects induced in cancerous and normal tissue. Starting with in vitro cell irradiation experiments, which define basic parameters for the subsequent tissue and animal studies, the whole multi-stage process is completed by clinical trials that translate the results of fundamental research into clinical application. In this context, the present dissertation focuses on the establishment of radiobiological in vitro cell experiments at unconventional, but clinical relevant radiation qualities. In the first part of the present work the energy dependent biological effectiveness of photons was studied examining low-energy X-rays (≤ 50 keV), as used for mammography, and high-energy photons (≥ 20 MeV) as proposed for future radiotherapy. Cell irradiation experiments have been performed at conventional X-ray tubes providing low-energy photons and 200 kV reference radiation as well. In parallel, unconventional quasi-monochromatic channeling X-rays and high-energy bremsstrahlung available at the radiation source ELBE of the Forschungszentrum Dresden-Rossendorf were considered for radiobiological experimentation. For their precise dosimetric characterization dosimeters based on the thermally stimulated emission of exoelectrons and on radiochromic films were evaluated, whereas just the latter was found to be suitable for the determination of absolute doses and spatial dose distributions at cell position. Standard ionization chambers were deployed for the online control of cell irradiation experiments. Radiobiological effects were analyzed in human mammary epithelial cells on different subcellular levels revealing an increasing amount of damage for decreasing photon energy. For this reason, the assumed photon energy dependence was reconfirmed for a cell line other than human lymphocytes, an important finding that was discussed on the 2007 Retreat of the German Commission on Radiological Protection. After successful finalization of the photon experiments the focus of the present dissertation was directed to the realization of in vitro cell irradiation experiments with laser-accelerated electrons. This research was carried out in the frame of the project onCOOPtics that aims on the development of laser-based particle accelerators, which promise accelerators of potentially compact size and more cost-effectiveness suitable for a widespread medical application, especially for high precision hadron therapy. The unique properties, i.e., the ultrashort bunch length and resultant ultrahigh pulse dose rate, of these unconventional particle accelerators demand for extensive investigations with respect to potential effects on the dosimetric and radiobiological characterization. Based on the experiences gained at ELBE first experiments on the radiobiological characterization of laser-accelerated electrons have been performed at the Jena Titanium:Sapphire laser system. After beam optimization, a sophisticated dosimetry system was established that allow for the online control of the beam parameters and for the controlled delivery of dose to the cell sample. Finally, worldwide first systematic in vitro cell irradiation experiments were carried out resulting in a reduced biological effectiveness for laser-accelerated electrons relative to the 200 kV X-ray reference, irrespectively on the biological effect and cell lines examined. These successful results are the basis for future in vivo studies and experiments with laser-accelerated protons.
16

Electron transport modelling in X-ray tubes

Hess, Robert January 1997 (has links)
No description available.
17

A study of the effect of surround and ambient lighting conditions on CRT screen colors /

Ouellette, Diane. January 1988 (has links)
Thesis (M.S.)--Rochester Institute of Technology, 1988. / Includes bibliographical references (leaves 38-39).
18

Achromatic perception in color image displays /

Gorzynski, Mark E. January 1992 (has links)
Thesis (M.S.)--Rochester Institute of Technology, 1992. / Typescript. Includes bibliographical references (leaves [152]-164).
19

Estudo do envelhecimento de um tubo de raios X por métodos não invasivos

BOTTARO, MARCIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:12Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
20

Estudo do envelhecimento de um tubo de raios X por métodos não invasivos

BOTTARO, MARCIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:12Z (GMT). No. of bitstreams: 0 / O objetivo do presente trabalho foi a avaliação do envelhecimento de um tubo de raios X com anodo de tungstênio utilizado para aplicações de radiodiagnóstico, por meio de aplicação de cargas de acordo com distribuições de cargas de trabalho da realidade brasileira e avaliações periódicas de grandezas associadas à qualidade de radiação produzida. Para o propósito deste trabalho, um sistema clínico com retificação monofásica de onda completa foi utilizado. Para avaliação em longo prazo das características do tubo de raios X relacionadas à carga de trabalho foi necessária a medição de parâmetros que pudessem representar de forma quantitativa o envelhecimento do tubo de raios X, estando estes relacionados principalmente ao desgaste do anodo. Esta medição indireta do envelhecimento do tubo levou a escolha de quatro parâmetros, alguns deles normalmente empregados na prática de controle de qualidade de equipamentos de radiologia diagnóstica: primeira e segunda camada semi-redutora (CSR), dimensões dos pontos focais, medida não invasiva do Potencial de Pico Prático e espectrometria de raios X. Estes parâmetros foram medidos inicialmente e após cada aplicação de carga pertinente. Para garantir a confiabilidade dos resultados, condições de reprodutibilidade foram estabelecidas para cada parâmetro de avaliação. As incertezas envolvidas em todos os processos de medição foram calculadas para avaliação da real contribuição dos efeitos do envelhecimento do tubo de raios X nos parâmetros não invasivos. Dentre os parâmetros avaliados, os que mostraram maior sensibilidade aos efeitos da aplicação de carga em longo prazo foram as energias médias obtidas por meio de espectrometria de raios X e as camadas semi-redutoras. Um modelo relacionado a estes parâmetros foi aplicado e estimativas da taxa de envelhecimento do tubo de raios X para diferentes tensões de aceleração e correntes anódicas foram obtidas. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0414 seconds