• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Measuring and modelling light scattering in paper

Johansson, Niklas January 2015 (has links)
Avhandlingen behandlar de teoretiska och praktiska aspekterna av att använda spektrala vinkelupplösta reflektansmätningar för optisk karakterisering av fiberbaserade material såsom papper och kartong. En spektral goniofotometer används för att mäta det reflekterade ljusets vinkelfördelning. En stor del av arbetet utgörs av att utvärdera instrumentets noggrannhet, samt utreda hur de vinkelupplösta mätningarna skall utföras på bästa sätt för att erhålla en så fullständig karakterisering som möjligt. Det reflekterade ljuset består av tre komponenter; ytreflektans, bulkreflektans samt fluorescens. En fullständig karakterisering förutsätter att dessa tre komponenter kan analyseras separat, vilket i detta arbete görs genom nyutvecklade metoder. En metod har utvecklats för separation av ytreflektans och bulkreflektans. Metoden bygger på att analysera hur den totala reflektansen förändras vid ökande absorption i det reflekterande materialet. Absorptionen kontrolleras genom inkjet-tryckning där tryckfärg appliceras på substratet i sådan mängd att bulkreflektansen helt släcks ut. Genom att kombinera mätningar på tryckt och otryckt substrat kan de båda komponenterna separeras. Trots att ytreflektansen från ett matt papper är liten i förhållande till bulkreflektansen, så visar resultaten att den ökar markant med ökande betraktningsvinkel och kan därmed ha stor inverkan på den totala reflektansen. Bidraget från fluorescens kan kvantitativt analyseras genom att kombinera mätningar utförda med respektive utan UV-filter. Vinkelupplösta mätningar och Monte Carlo-simuleringar av fluorescensens vinkelfördelning visar att dess anisotropi är relaterad till det medeldjup vid vilket fluorescensen emitteras. Resultaten förklarar observerade skillnader och motstridigheter i tidigare rapporterade studier kring huruvida fluorescens kan anses vara Lamberskt fördelad. Samtliga goniofotometriska mätningar är utförda med ett kompakt, kommersiellt tillgängligt, dubbelstråleinstrument. För att undersöka instrumentets lämplighet för absoluta reflektansmätningar utförs en analys av dess mätnoggrannhet. Resultaten visar att instrumentets kompakta storlek i kombination med den anisotropa reflektansen från papper introducerar systematiska fel av samma storleksordning som den totala mätnoggrannheten. Dessa fel uppstår på grund av den relativt stora detektorapertur som måste användas vid mätningar av diffus reflektans, vilket är karakteristiskt för papper och kartong. Resultaten visar även att felen är störst vid flacka mätvinklar och för prover med hög grad av anisotropisk reflektans, och en geometrisk korrektionsmetod för denna typ av systematiska fel föreslås. Spektrala och vinkelupplösta mätningar medför per automatik stora mängder mätdata. Genom att använda strålningstransportteori som en matematisk modell för hur ljus sprids i papper kan mätdatat reduceras till en uppsättning beskrivande materialparameterar. Att uppskatta dessa optiska parametrar utifrån vinkelupplösta reflektansmätningar är i sig ett komplicerat problem, vilket dessutom är känsligt för mätfel och val av mätvinklar. Detta inversa problem analyseras i detalj, och speciellt hur valet av mätvinklar kan reduceras utan att försämra förutsättningarna för estimeringen. Simuleringar visar att mätningarna kan begränsas till infallsplanet, eller till och med enbart framåtriktningen, så länge tillräckligt flacka mätvinklar är inkluderade i mätsekvensen. / This thesis is about measuring and modelling light reflected from paper by using goniophotometric measurements. Measuring bidirectional reflectance requires highly accurate instruments, and a large part of the work in this thesis is about establishing the requirements that must be fulfilled to ensure valid data. A spectral goniophotometer is used for measuring the light reflected from paper and methods are developed for analyzing the different components, i.e. the fluorescence, surface reflectance and bulk reflectance, separately. A separation of the surface and bulk reflectance is obtained by inkjet printing and analyzing the total reflectance in the absorption band of the ink. The main principle of the method is to add dye to the paper until the bulk scattered light is completely absorbed. The remaining reflectance is solely surface reflectance, which is subtracted from the total reflectance of the undyed sample to give the bulk reflectance. The results show that although the surface reflectance of a matte paper is small in comparison with the bulk reflectance, it grows rapidly with increasing viewing angle, and can have a large influence on the overall reflectance. A method for quantitative fluorescence measurements is developed, and used for analyzing the angular distribution of the fluoresced light. The long-standing issue whether fluorescence from turbid (or amorphous) media is Lambertian or not, is resolved by using both angle-resolved luminescence measurements and radiative transfer based Monte Carlo simulations. It is concluded that the degree of anisotropy of the fluoresced light is related to the average depth of emission, which in turn depends on factors such as concentration of fluorophores, angle of incident light and the absorption coefficient at the excitation wavelength. All measurements are conducted with a commercially available benchtop sized double-beam spectral goniophotometer designed for laboratory use. To obtain reliable results, its absolute measurement capability is evaluated in terms of measurement accuracy. The results show that the compact size of the instrument, combined with the anisotropic nature of reflectance from paper, can introduce significant systematic errors of the same order as the overall measurement uncertainty. The errors are related to the relatively large detection solid angle that is required when measuring diffusely reflecting materials. Situations where the errors are most severe, oblique viewing angles and samples with high degree of anisotropic scattering, are identified, and a geometrical correction is developed. Estimating optical properties of a material from bidirectional measurements has proved to be a challenging problem and the outcome is highly dependent on both the quality and quantity of the measurements. This problem is analyzed in detail for optically thick turbid media, and the study targets the case when a restricted set of detection angles are available. This is the case when e.g. an unobstructed view of the sample is not possible. Simulations show that the measurements can be restricted to the plane of incidence (in-plane), and even the forward direction only, without any significant reduction in the precision or stability of the estimation, as long as sufficiently oblique angles are included.
2

Kalibrovaný výběr skutečných barev pro aplikace v rozšířené realitě / A Calibrated Real-World Colour Picker for Augmented Reality Applications

Zikmund, Martin January 2019 (has links)
This thesis describes the process of creating an augmented reality mobile application which allows designers, architects and researchers to retrieve accurate colour information picked from the real-world environment. Specifically, the goal is not only to obtain colour coordinates for the area of interest but to find a set of matching colour samples in an extensive database of colour atlases provided with the application. To properly understand how the camera sensor perceives colour under current lighting conditions, it must be calibrated beforehand using a physical colour chart. Based on this calibration, we can estimate the picked colour coordinates in a standardised colour space. The mobility aspect is the main advantage of the resulting application. Instead of carrying multiple colour atlases, the user can estimate colour matching just using a mobile device and a portable colour chart.
3

Quantification of Solar Photovoltaic Encapsulant Browning Level Using Image Processing Tool

January 2016 (has links)
abstract: In recent years, solar photovoltaic (PV) industry has seen lots of improvements in technology and of growth in market with crystalline silicon PV modules being the most widely used technology. Plant inspections are gaining much importance to identify and quantitatively determine the impacts of various visual defects on performance. There are about 86 different types of defects found in the PV modules installed in various climates and most of them can be visually observed. However, a quantitative determination of impact or risk of each of identified defect on performance is challenging. Thus, it is utmost important to quantify the risk for each of the visual defects without any human subjectivity. The best way to quantify the risk of each defect is to perform current-voltage measurements of the defective modules installed in the plant but it requires disruption of plant operation, expensive measuring equipment and intensive human resources. One of the most riskiest and dominant visual defects is encapsulant browning which affects the PV module performance in the form of current degradation. The present study deals with developing an automated image processing tool which can address the issues of human subjectivity on browning level impacting performance. The image processing tool developed in this work can be directly used to quantify the impact of browning on performance without intrusively disconnecting the modules from the plant. In this work, the quantified browning level impact on performance has also been experimentally validated through a correlation study using short-circuit current and reflectance/transmittance measurements of browned PV modules retrieved from aged plants/systems installed in diverse climatic conditions. The primary goal of the image processing tool developed in this work is to determine the performance impact of encapsulant browning without interrupting the plant operation for I-V measurements. The use of image processing tool provides a single numerical value, called browning index (BI), which can accurately quantify browning levels on modules and also correlate with the performance and reflectance/transmittance parameters of the modules. / Dissertation/Thesis / Masters Thesis Mechanical Engineering 2016
4

Light-tissue interactions for developing portable and wearable optoelectronic devices for sensing of tissue condition, diagnostics and treatment in photodynamic therapy (PDT)

Kulyk, Olena January 2016 (has links)
This thesis presents the development and in-vivo applications of wearable and portable devices for the investigation of light interaction with tissue involved in Photodynamic therapy (PDT) and during contraction of muscles. A hand-held device and a clinical method were developed for time course in-vivo imaging of the fluorescence of the photosensitizer Protoporphyrin IX (PpIX) in healthy and diseased skin with the aim to guide improvement of PDT protocols. The device was used in a small clinical study on 11 healthy volunteers and 13 patients diagnosed with non-melanoma skin cancer (NMSC). Two types of PpIX precursors were administered: Ameluz gel and Metvix® cream. The fluorescence was imaged with a 10 minute time step over three hours which was the recommended metabolism time before commencing PDT treatment at Ninewells Hospital, Dundee. The fluorescence time course was calculated by integrating the areas with the highest intensity. The fluorescence continued to grow in all subjects during the three hours. The time course varied between individuals. There was no statistical significance between either healthy volunteers or patients in Ameluz vs Metvix® groups; nor was there statistical difference between the three lesions groups (Actinic keratosis (AK) Ameluz vs AK Metvix® vs Basal cell carcinoma (BCC) Metvix®). The p-value was larger than 0.05 in a two sample t-test with unequal variances for all the groups. However, there was strong body site dependence between the head & neck compared to the lower leg & feet, or the trunk & hands body site groups (p-value < 0.01). One of the possible explanations for this was temperature and vasculature variation in skin at different body sites: the temperature is higher and the vasculature structure is denser at the head and the neck compared to the lower leg or the trunk. The temperature was not measured during the study. So in order to support this hypothesis, typical skin temperatures at the lesion sites were taken from the IR thermal images of healthy skin available in literature. PpIX fluorescence had a positive correlation to temperature. If this hypothesis is true, it will be highly important to PDT treatment. Increasing the temperature could speed up the metabolism and reduce the waiting time before starting the treatment; ambient temperature should be taken into account for daylight PDT; cooling air as pain management should be administered with caution. Potential improvements for wearable PDT light sources were investigated by modelling light transport in skin for the current LED-based Ambulight PDT device, a commercial OLED for future devices and a directional OLED developed in the group. The optical models were implemented in commercial optical software (with intrinsic Monte Carlo ray tracing and Henyey-Greenstein scattering approximation) which was validated on diffuse reflectance and transmittance measurements using in-house made tissue phantoms. The modelling was applied to investigate the benefits from diffusive and forward scattering properties of skin on light transmission in treatment light sources. 1 mm thick skin can only compensate approximately 10% of non-uniform irradiance. It means that uniform illumination is crucial for the treatment light sources. Forward scattering in skin showed a 10% improved light transmission from a collimated emission compared to a wide angle Lambertian emission. However, depth-dependent transmission measurements of directional vs Lambertian emission from organic light emitting films (a nano-imprinted grating was fabricated to provide directional emission in one of the films), collimated vs diffused HeNe laser light through fresh porcine skin did not show the expected improvement. This could be explained by skin roughness which was previously found to change the optical properties and may also affect light coupling. The modelling was applied to guide an optical design of another wearable device – a muscle contraction sensor. Muscle is fibrous and because of that scatters light differently in different directions. The sensor detects the change in backscattered light in parallel and perpendicular directions with respect to muscle fibres. The sensor was implemented on a wearable bandage on fully flexible substrate with flexible OLED and organic photodiodes. The major advantages of organic optoelectronic sensing compared to conventional electromyography (EMG) sensors are the ability to distinguish two types of contractions (isotonic and isometric), insensitivity to electromagnetic interference and the absence of an immune response due to non-invasive electrode-free sensing. Optical modelling was performed to understand the operation of the sensor. A 3D anisotropic optical model of scattering in muscle was created by geometrical manipulations with the standard Henyey-Greenstein scattering volumes. The penetration depth from the Super Yellow OLED was found to be 20-25 mm; the optimal separation between the source and the detector was found to be 20 mm. This distance provided a still detectable signal along with the best discrimination between the two backscatterings. When a 2 mm thick layer of skin and a 2 mm thick layer of adipose tissue were added to the model, the signal was hugely diffused. The discrimination between the two backscatterings decreased by three orders of magnitude, the penetration depth in muscle was reduced, and the intensity of the signal dropped down but was still detectable. With 5 mm thick adipose tissue and 2 mm thick skin the signal was too diffused and interacted with very shallow layers of muscle which approached the limits of the optical sensing of muscle activity.
5

Measurements of the complex refractive index of volcanic ash

Reed, Benjamin Edward January 2016 (has links)
This thesis describes laboratory measurements of the complex refractive index of volcanic ash particles. These measurements are needed to model the radiative impact of volcanic ash, vital for accurate satellite remote sensing. Three experimental methods have been developed, and the results for the complex refractive index and optical properties of a wide range of volcanic ash samples are presented. Measurements were made of the spectral transmission of radiation through suspended volcanic ash particles inside an aerosol cell, using a Fourier transform spectrometer at infrared wavelengths and two diffraction grating spectrometers covering ultraviolet, visible, and near-infrared wavelengths. In addition to the optical measurements, a suite of sampling and sizing instruments were connected downstream of the aerosol cell to measure the particle size distribution. The method was calibrated using two quartz samples. Mass extinction coefficients for nine volcanic ash samples, at 0.3-14 μm, are presented and show considerable variation. These variations are linked to the composition of the samples, measured using X-ray fluorescence (XRF) analysis. The complex refractive index, at 0.3-14 μm, of the two quartz samples and two samples of volcanic ash from the 2010 Eyjafjallajökull eruption were retrieved from the extinction measurements. The forward model used Mie theory and a classical damped harmonic oscillator (CDHO) model to represent the complex refractive index of the samples in terms of a finite set of band parameters, as well as the real refractive index of the sample in the small wavelength limit. Previous studies have shown that there is a redundancy in the retrievals between the band strength parameters and the real refractive index in the small wavelength limit, which can lead to spurious values for the retrieved complex refractive index. This problem was overcome by using an independent measurement of the real refractive index at a visible wavelength, to constrain the model parameter of the real refractive index in the short wavelength limit. Independent measurements of the complex refractive index at visible wavelengths are also important because the extinction produced at these wavelengths is highly sensitive to the particle size distribution, and any uncertainty in the measured size distribution will contribute to significant systematic error in the refractive index retrieved from extinction. The retrieved spectral complex refractive index of Eyjafjallajökull ash was applied using the ORAC retrieval scheme to measurements of the 2010 Eyjafjallajökull eruptionmade by theMODIS instrument aboard NASA's Terra satellite. Significant difference were found in the retrieved plume parameters of optical path, effective radius, and plume altitude, compared to assuming a literature measurement for the refractive index of pumice. For three discrete visible wavelengths (450, 546.7, and 650 nm) an optical microscope was used to make measurements of the complex refractive index of the volcanic ash samples. The long-established Becke line method was used to measure the real refractive index of the samples. For the imaginary refractive index, a new and novelmethod was developed involving measurements of the attenuation of light in individual particles. A strong linear correlation was found between the SiO<sub>2</sub> content of the samples and both their real and imaginary refractive indices at the visible wavelengths investigated. Furthermore, from the XRF compositional analysis of the samples values were calculated for the ratio of non-bridging oxygen atoms per tetrahedral cation (NBO/T), and it was found that NBO/T was an even stronger predictor of real refractive index at visible wavelengths. The optical microscope measurements could only be applied to particles with a radius larger than 10 μm. A new refractometer method was investigated for retrieving the real refractive index of submicron particles from colloidal reflectance measurements close to the critical angle in an internal reflection configuration. A coherent scattering model (CSM) was used to model the coherent reflection from a half-space of monodisperse or polydisperse particles, and a simple extension of the model is presented to properly account for the modified size distribution at the interface in an internal reflection set-up. A rigorous sensitivity analysis was performed to determine how experimental uncertainties propagate into uncertainty associated with the retrieved real refractive index, and the uncertainty due to non-spherical effects was estimated using T-matrix methods. Experimental reflectance data at a wavelength of 635 nm were obtained for spherical monodisperse polystyrene calibration particles, a polydisperse sand sample, and a polydisperse volcanic ash sample. The retrieved values for the real refractive index agreed, within propagated uncertainties, with values measured using other techniques. The method is shown to be a viable technique for measuring the real refractive index of small quantities of submicron particles, and can also retrieve the concentration and size of particles.

Page generated in 0.5474 seconds