• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identificação de assinaturas químicas em resíduos de disparos de arma de fogo em diferentes alvos / Identification of chemical signatures of gunshot residues in differents fabrics

Freitas, João Carlos Dias de 29 October 2010 (has links)
A ciência forense moderna caminha lado a lado com a pesquisa científica. Os cientistas forenses se deparam diariamente com vários casos que requerem a análise de resíduos provenientes de disparos de arma de fogo (gunshot residues - GSR). Este trabalho contempla o desenvolvimento de uma metodologia para determinar assinaturas químicas de disparos de arma de fogo, medindo-se as concentrações de Pb, Ba e Sb presentes nos resíduos provenientes destes disparos depositados nas proximidades do orifício de entrada de projéteis, baseada na técnica de espectrometria de massas de alta resolução com fonte de plasma indutivamente acoplado (ICP-MS). Foram realizados disparos em cinco tipos de tecidos-alvos e coletados testemunhos em regiões próximas ao orifício de entrada dos projéteis. Os resultados demonstraram que o método possibilitou identificar e distinguir os resíduos de revólver calibre .38 ao de pistolas calibres .40 e 9 mm. O uso de gráficos ternários como ferramenta de análise dos dados coletados, permitiu identificar padrões específicos de distribuição de amostras em branco e dos resíduos depositados após disparos de revólveres e pistolas. A metodologia possibilitou a atribuição da origem dos disparos por meio de confirmação dos resíduos coletados também das mãos dos atiradores. Como conseqüência a metodologia representa um grande avanço nos procedimentos da polícia e visa adicionar uma contribuição valiosa às investigações forenses. / The modern forensic science goes hand in hand with scientific research. The forensic scientists are faced every day with many cases requiring the analysis of residues from firing gun (gunshot residues GSR). This works describes the development of a methodology to determine chemical signatures of shots from a firearm, by measuring the concentrations of Pb, Ba e Sb in the residues from these shots deposited near the entrance hole of bullets, based on the technique with high resolution inductively coupled plasma mass spectrometry (HRICP-MS). Shots were performed on five types of target-fabrics and collected testimonies from regions close to the entrance hole of projectiles. The results showed that the method enabled us to identify and distinguish the residues of the .38 caliber revolver and pistols .40 and 9mm caliber. The use of ternary graphs as a tool for data analysis helped to identify specific patterns of distribution of blank samples and gunshot residues deposited after firing revolvers and pistols. The methodology enabled the assignment of the origin of the shot through the confirmation of the residues collected also from the hands of shooters. As a result the methodology in police procedures and aims to add a valuable contribution to forensic investigations.
2

Identificação de assinaturas químicas em resíduos de disparos de arma de fogo em diferentes alvos / Identification of chemical signatures of gunshot residues in differents fabrics

João Carlos Dias de Freitas 29 October 2010 (has links)
A ciência forense moderna caminha lado a lado com a pesquisa científica. Os cientistas forenses se deparam diariamente com vários casos que requerem a análise de resíduos provenientes de disparos de arma de fogo (gunshot residues - GSR). Este trabalho contempla o desenvolvimento de uma metodologia para determinar assinaturas químicas de disparos de arma de fogo, medindo-se as concentrações de Pb, Ba e Sb presentes nos resíduos provenientes destes disparos depositados nas proximidades do orifício de entrada de projéteis, baseada na técnica de espectrometria de massas de alta resolução com fonte de plasma indutivamente acoplado (ICP-MS). Foram realizados disparos em cinco tipos de tecidos-alvos e coletados testemunhos em regiões próximas ao orifício de entrada dos projéteis. Os resultados demonstraram que o método possibilitou identificar e distinguir os resíduos de revólver calibre .38 ao de pistolas calibres .40 e 9 mm. O uso de gráficos ternários como ferramenta de análise dos dados coletados, permitiu identificar padrões específicos de distribuição de amostras em branco e dos resíduos depositados após disparos de revólveres e pistolas. A metodologia possibilitou a atribuição da origem dos disparos por meio de confirmação dos resíduos coletados também das mãos dos atiradores. Como conseqüência a metodologia representa um grande avanço nos procedimentos da polícia e visa adicionar uma contribuição valiosa às investigações forenses. / The modern forensic science goes hand in hand with scientific research. The forensic scientists are faced every day with many cases requiring the analysis of residues from firing gun (gunshot residues GSR). This works describes the development of a methodology to determine chemical signatures of shots from a firearm, by measuring the concentrations of Pb, Ba e Sb in the residues from these shots deposited near the entrance hole of bullets, based on the technique with high resolution inductively coupled plasma mass spectrometry (HRICP-MS). Shots were performed on five types of target-fabrics and collected testimonies from regions close to the entrance hole of projectiles. The results showed that the method enabled us to identify and distinguish the residues of the .38 caliber revolver and pistols .40 and 9mm caliber. The use of ternary graphs as a tool for data analysis helped to identify specific patterns of distribution of blank samples and gunshot residues deposited after firing revolvers and pistols. The methodology enabled the assignment of the origin of the shot through the confirmation of the residues collected also from the hands of shooters. As a result the methodology in police procedures and aims to add a valuable contribution to forensic investigations.
3

Desenvolvimento de sensor eletroquímico para monitoramento de chumbo em resíduos de disparos de armas de fogo / Development of an electrochemical sensor for lead analysis in gunshot residues

Salles, Maiara Oliveira 26 August 2011 (has links)
Duas metodologias distintas foram desenvolvidas para a determinação de chumbo em Resíduos de Disparos de Armas de Fogo (RDAF) utilizando microeletrodo de ouro. Na primeira delas, a superfície eletródica foi modificada com filme de bismuto em meio alcalino (pH = 13) e na outra as análises foram realizadas com microeletrodo não modificado em meio ácido com cloreto. Os RDAF foram coletados do alvo atingido pela bala e das mãos do atirador. Dos alvos, foi recortada uma região próxima ao orifício feito pela bala. Já para remoção dos RDAF das mãos do atirador, foi utilizado um algodão embebido em solução de EDTA 2% (m/v). Os resíduos foram submetidos a um processo de extração que consistiu em adicionar 10 mL de solução de HNO3 10% (m/m) ao frasco contendo o alvo ou o algodão com os RDAF. Em seguida, a mistura foi submetida ao ultrassom por 2 horas a uma temperatura de 60°C. As amostras provenientes dos alvos foram analisadas com o microeletrodo de ouro modificado com bismuto em meio alcalino por voltametria de redissolução anódica. Com essa metodologia, obteve-se um limite de detecção (3σ/sensibilidade) de 12,5 nmol L-1, uma faixa linear entre 40 e 6700 nmol L-1 e um desvio padrão relativo de 3,4% (n = 12). Foi possível analisar amostras provenientes de duas armas diferentes (pistola 9 mm e revólver 0.38 polegadas) e três munições distintas (normal, spl® e CleanRange®). Constatou-se um aumento da quantidade de chumbo presente nos resíduos à medida que o atirador se aproxima do alvo e que os valores dependem da arma e munição utilizadas. Com a outra metodologia as análises foram realizadas na própria solução extratora, com adição de cloreto, sem qualquer modificação da superfície eletródica. Neste caso, o limite de detecção (3σ/sensibilidade) encontrado foi de 1,7 nmol L-1, a faixa linear ficou entre 10 e 100 nmol L-1 e o desvio padrão relativo de 10 medidas foi 2,5%. Foram analisados resíduos provenientes das mãos dos atiradores de quatro diferentes armas (revólver 0.38 polegadas, espingardas calibre 12, 22 e 38) e de seis diferentes munições (CleanRange®, normal, semi-enjaquetada, 3T®, Eley® e CBC®). Os resultados obtidos com a metodologia proposta foram comparados com aqueles oriundos de análise por espectroscopia de absorção atômica e houve concordância em um nível de confiança de 95%. Foi também realizada uma análise quimiométrica das soluções contendo os RDAF. Os resultados mostraram a possibilidade de discriminação em relação à arma e munição utilizadas. Os filmes formados nas superfícies eletródicas foram estudados utilizando o Microscópio Eletroquímico de Varredura (SECM), a Microbalança Eletroquímica de Cristal de Quartzo (MECQ) e o Microscópio Eletrônico de Varredura (MEV). A deposição dos filmes de bismuto, chumbo e bismuto/chumbo em meio alcalino ocorre de forma heterogênea e esses filmes reagem com oxigênio e ferricianeto. Em meio ácido, a presença do cloreto na solução de depósito do filme de chumbo provoca aumento na rugosidade do filme, com consequente melhoria no sinal analítico. Também se observou que o cloreto facilita o processo de redissolução do filme de chumbo. / Two different methodologies were developed to analyze lead from gunshot residues (GSR) with a gold microelectrode: modification of the electrode surface with a bismuth film in alkaline solution (pH = 13) and use of an unmodified gold microelectrode in acidic media with chloride. GSR were collected from cloth targets and shooters\' hand after test firing. From the targets, a region close to the bullet hole was cutted off. GSR were removed from the shooters\' hand using a cotton swab embedded in a 2% (m/v) EDTA solution. The target and the cotton swab were placed in a steril vial containing 10 mL of a 10% (m/m) HNO3 solution to extract the GSR. Then, all vials were placed in the ultrasound for 2 hours at 60°C. Samples from the targets were analyzed with a gold microelectrode modified with a bismuth film in alkaline solution by anodic stripping voltammetry with a detection limit of 12.5 nmol L-1 (3σ/slope), linear range between 40 and 6700 nmol L-1 and a relative standard deviation of 3.4% (n = 12). Two different handguns (pistoll 9 mm and a revolver 0.38 inches) and tree different ammunition (normal, spl® and CleanRange®) were analyzed and the lead amount was dependent on the gun and ammunition used in the tests. An increase in the amount of lead from the GSR was observed as the distance between the shooter and the target decreased. Lead analyses were also performed in the extraction solution with bare gold microelectrodes in the presence of chloride ions. In this case, the detection limit was 1.7 nmol L-1 (3σ/slope), the linear range lied between 10 and 100 nmol L-1 and the relative standard deviation for 10 measurements was 2.5%. GSR residues form four different guns (revolver 0.38 inches, 12 caliber pump, a repeating rifle 0.38 and a semi automatic .22 caliber rifle) and six different ammunitions (CleanRange®, normal, semi jacketed, 3T®, Eley® and CBC®) were analyzed. The results obtained with the proposed methodology were compared with those from atomic absorption spectroscopy analysis and the paired t-test student indicated that there was no significant difference between the results obtained with both methods at a 95% confidence level. A chemometric analysis was also performed and the results showed the possibility to discriminate the guns and the ammunitions used. Metallic flms formed onto the electrode surface were studied by using Scanning Electrochemial Microscopy (SECM), Electrochemical Quartz Crystal Microbalance (EQCM) and Scanning Electronic Microscopy (SEM). The deposition of bismuth, lead and bismuth/lead films in alkaline solution is heterogeneous and the films react with oxygen and ferricyanide. In acidic media, the presence of chloride ions in the depositing solution causes an increase in the film roughness and facilitates the lead film dissolution
4

Desenvolvimento de sensor eletroquímico para monitoramento de chumbo em resíduos de disparos de armas de fogo / Development of an electrochemical sensor for lead analysis in gunshot residues

Maiara Oliveira Salles 26 August 2011 (has links)
Duas metodologias distintas foram desenvolvidas para a determinação de chumbo em Resíduos de Disparos de Armas de Fogo (RDAF) utilizando microeletrodo de ouro. Na primeira delas, a superfície eletródica foi modificada com filme de bismuto em meio alcalino (pH = 13) e na outra as análises foram realizadas com microeletrodo não modificado em meio ácido com cloreto. Os RDAF foram coletados do alvo atingido pela bala e das mãos do atirador. Dos alvos, foi recortada uma região próxima ao orifício feito pela bala. Já para remoção dos RDAF das mãos do atirador, foi utilizado um algodão embebido em solução de EDTA 2% (m/v). Os resíduos foram submetidos a um processo de extração que consistiu em adicionar 10 mL de solução de HNO3 10% (m/m) ao frasco contendo o alvo ou o algodão com os RDAF. Em seguida, a mistura foi submetida ao ultrassom por 2 horas a uma temperatura de 60°C. As amostras provenientes dos alvos foram analisadas com o microeletrodo de ouro modificado com bismuto em meio alcalino por voltametria de redissolução anódica. Com essa metodologia, obteve-se um limite de detecção (3σ/sensibilidade) de 12,5 nmol L-1, uma faixa linear entre 40 e 6700 nmol L-1 e um desvio padrão relativo de 3,4% (n = 12). Foi possível analisar amostras provenientes de duas armas diferentes (pistola 9 mm e revólver 0.38 polegadas) e três munições distintas (normal, spl® e CleanRange®). Constatou-se um aumento da quantidade de chumbo presente nos resíduos à medida que o atirador se aproxima do alvo e que os valores dependem da arma e munição utilizadas. Com a outra metodologia as análises foram realizadas na própria solução extratora, com adição de cloreto, sem qualquer modificação da superfície eletródica. Neste caso, o limite de detecção (3σ/sensibilidade) encontrado foi de 1,7 nmol L-1, a faixa linear ficou entre 10 e 100 nmol L-1 e o desvio padrão relativo de 10 medidas foi 2,5%. Foram analisados resíduos provenientes das mãos dos atiradores de quatro diferentes armas (revólver 0.38 polegadas, espingardas calibre 12, 22 e 38) e de seis diferentes munições (CleanRange®, normal, semi-enjaquetada, 3T®, Eley® e CBC®). Os resultados obtidos com a metodologia proposta foram comparados com aqueles oriundos de análise por espectroscopia de absorção atômica e houve concordância em um nível de confiança de 95%. Foi também realizada uma análise quimiométrica das soluções contendo os RDAF. Os resultados mostraram a possibilidade de discriminação em relação à arma e munição utilizadas. Os filmes formados nas superfícies eletródicas foram estudados utilizando o Microscópio Eletroquímico de Varredura (SECM), a Microbalança Eletroquímica de Cristal de Quartzo (MECQ) e o Microscópio Eletrônico de Varredura (MEV). A deposição dos filmes de bismuto, chumbo e bismuto/chumbo em meio alcalino ocorre de forma heterogênea e esses filmes reagem com oxigênio e ferricianeto. Em meio ácido, a presença do cloreto na solução de depósito do filme de chumbo provoca aumento na rugosidade do filme, com consequente melhoria no sinal analítico. Também se observou que o cloreto facilita o processo de redissolução do filme de chumbo. / Two different methodologies were developed to analyze lead from gunshot residues (GSR) with a gold microelectrode: modification of the electrode surface with a bismuth film in alkaline solution (pH = 13) and use of an unmodified gold microelectrode in acidic media with chloride. GSR were collected from cloth targets and shooters\' hand after test firing. From the targets, a region close to the bullet hole was cutted off. GSR were removed from the shooters\' hand using a cotton swab embedded in a 2% (m/v) EDTA solution. The target and the cotton swab were placed in a steril vial containing 10 mL of a 10% (m/m) HNO3 solution to extract the GSR. Then, all vials were placed in the ultrasound for 2 hours at 60°C. Samples from the targets were analyzed with a gold microelectrode modified with a bismuth film in alkaline solution by anodic stripping voltammetry with a detection limit of 12.5 nmol L-1 (3σ/slope), linear range between 40 and 6700 nmol L-1 and a relative standard deviation of 3.4% (n = 12). Two different handguns (pistoll 9 mm and a revolver 0.38 inches) and tree different ammunition (normal, spl® and CleanRange®) were analyzed and the lead amount was dependent on the gun and ammunition used in the tests. An increase in the amount of lead from the GSR was observed as the distance between the shooter and the target decreased. Lead analyses were also performed in the extraction solution with bare gold microelectrodes in the presence of chloride ions. In this case, the detection limit was 1.7 nmol L-1 (3σ/slope), the linear range lied between 10 and 100 nmol L-1 and the relative standard deviation for 10 measurements was 2.5%. GSR residues form four different guns (revolver 0.38 inches, 12 caliber pump, a repeating rifle 0.38 and a semi automatic .22 caliber rifle) and six different ammunitions (CleanRange®, normal, semi jacketed, 3T®, Eley® and CBC®) were analyzed. The results obtained with the proposed methodology were compared with those from atomic absorption spectroscopy analysis and the paired t-test student indicated that there was no significant difference between the results obtained with both methods at a 95% confidence level. A chemometric analysis was also performed and the results showed the possibility to discriminate the guns and the ammunitions used. Metallic flms formed onto the electrode surface were studied by using Scanning Electrochemial Microscopy (SECM), Electrochemical Quartz Crystal Microbalance (EQCM) and Scanning Electronic Microscopy (SEM). The deposition of bismuth, lead and bismuth/lead films in alkaline solution is heterogeneous and the films react with oxygen and ferricyanide. In acidic media, the presence of chloride ions in the depositing solution causes an increase in the film roughness and facilitates the lead film dissolution

Page generated in 0.0896 seconds