• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 542
  • 376
  • 73
  • 29
  • 16
  • 16
  • 16
  • 16
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • Tagged with
  • 1209
  • 519
  • 417
  • 343
  • 252
  • 211
  • 184
  • 139
  • 136
  • 113
  • 105
  • 95
  • 86
  • 76
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Estudo comparativo in vitro da capacidade adesiva da resina fotoativada pela luz halogena e por laser de argonio, utilizando-se brackets metalicos em pre-molares humanos

CARILLO, VITORIA E.B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:49Z (GMT). No. of bitstreams: 1 09878.pdf: 6131893 bytes, checksum: 6f914465126a59ad76dc82dbeae6a39f (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
292

Avaliação imediata e após 6 meses da resistência de união a dentina de restaurações de resina composta classe I in vivo e in vitro

Rêgo, Heleine Maria Chagas [UNESP] 23 June 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-23. Added 1 bitstream(s) on 2016-06-07T17:17:18Z : No. of bitstreams: 1 000865416.pdf: 2581195 bytes, checksum: baec4e58131e8a8b1372e9f152ca300b (MD5) / Este estudo avaliou a resistência de união a dentina de restaurações de resina composta de forma imediata (24 horas) e em longo prazo (6 meses), submetidos a diferentes protocolos de envelhecimento. Cem dentes posteriores humanos foram divididos em cinco grupos (n = 20) de acordo protocolo de envelhecimento que receberam e posteriormente subdivididos em dois subgrupos (n = 10) de acordo com o tempo de armazenamento, totalizando dez subgrupos: In vivo (permaneceu em atividade bucal por 24 horas ou 6 meses); Estufa (armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem (submetidos a 27/666 ou 5000/120000 ciclos termomecânicos); Estufa com Pressão Pulpar Simulada (PPS) (restauração realizada sob PPS e em seguida armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem com PPS (restauração realizada sob PPS e em seguida submetidos a 27/666 -24 horas- ou 5000/120000 -6 meses- ciclos termomecânicos). Após a abertura da cavidade, a restauração foi realizada com a aplicação de ácido fosfórico a 37% (Vigodent), sistema adesivo Adper Single Bond 2 (3M ESPE) e resina composta Grandio (Voco), seguindo a orientação dos fabricantes. Após os diferentes tratamentos os espécimes foram seccionados obtendo-se palitos que foram submetidos ao teste de microtração. Os valores obtidos foram submetidos ao teste ANOVA dois fatores (protocolo de envelhecimento e tempo de armazenamento) e em seguida ao Teste de Tukey (5%). Os resultados para os testes de microtração foram (em MPa ±dp): Grupo estufa 24 h, 24,96±0,95A; Grupo ciclagem 24 horas, 23,96 ± 0,56AB; Grupo in vivo 24 horas, 23,21 ± 1,23AB; Grupo ciclagem com PPS 24 horas, 19,49 ± 1,51BC, Grupo ciclagem 6 meses, 18,16 ± 0,80CD; Grupo ciclagem com PPS 6 meses, 17,88 ± 1,25CD; Grupo estufa com PPS 24 horas, 17,65 ± 0,45CD; Grupo estufa 6 meses, 16,68 ± 1,30CD; Grupo estufa com PPS 6 meses, 14,33 ± 1,48D; Grupo in vivo 6 meses,.... / This study evaluated the bond strength of composite resin restorations submitted to different storage aging protocols, immediately and long-term (6 months). One hundred human posterior teeth were divided into five groups (n = 20) according storage aging protocol: Group, Group in vivo, Group water, Group cycling, Group water with Simulated Pulpal Pressure (PPS) and Group cycling with Simulated Pulpal Pressure. As further subdivided into two subgroups (n = 10) according to the time of storage were performed: 24 hours (24 hours in vivo 24 hours in water, 27/666 thermal and mechanical cycles) 6 months (6 months in vivo, 6 months in water and 5000/120000 thermal and mechanical cycles). After the opening of the cavity, the restoration was carried out with the use of phosphoric acid 37% (Vigodent), Single Bond 2 adhesive system (3M ESPE) and composite resin Grandio (Voco), following the lead of the manufacturers. After being held aging protocols for the storage time subgroup belonging specimens were sectioned obtaining sticks were submitted to microtensile test. Data were submitted to ANOVA two factors (aging and storage time) and then Tukey test (5%). The results for the microtensile tests were (MPa) ± SD: Group water 24 hours, 24.96 ± 0.95A; Group cycling 24 hours, 23.96 ± 0.56AB; Group in vivo 24h, 23.21 ± 1.23AB; Group cycling with PPS 24 hours, 19.49 ± 1.51BC, group cycling six months, 18.16 ± 0.80CD; Group cycling with PPS 6 months, 17.88 ± 1.25CD; Group water with PPS 24 hours, 17.65 ± 0.45CD; Group water 6 months, 16.68 ± 1.30CD; Group water with PPS 6 months, 14.33 ± 1,48D; In vivo group 6 months, 14.16 ± 1,51D. It was concluded that the different aging protocols used as storage times influence the bond strength dentin-resin
293

Incorporação do metacrilato 2-tert-butilaminoetil a uma resina acrílica para a base protética: caracterização química e efeito sobre a resistência flexural

Rodriguez, Larissa Santana [UNESP] 05 April 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-05Bitstream added on 2014-06-13T19:17:33Z : No. of bitstreams: 1 rodriguez_ls_me_arafo.pdf: 1313049 bytes, checksum: 4063f1e0e598d952104412578f2d3739 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A fim de prevenir infecções bucais e consequentemente melhorar a qualidade de vida dos usuários de prótese, diversas tentativas de incorporar agentes antimicrobianos a resinas acrílicas tem sido relatadas na literatura. A incorporação do metacrilato 2-tert-butilaminoetil (TBAEMA) a uma resina acrílica para base protética seria uma alternativa plausível no intuito de se reduzir ou eliminar a colonização dessa superfície por microrganismos patogênicos, pois esta substância apresenta grupos amina em sua composição, o que poderia indicar uma possível atividade antimicrobiana da base protética. Objetivo: O objetivo deste trabalho foi investigar a interação química entre o TBAEMA e a resina acrílica bem como a presença de grupos amina na superfície da resina, e ainda avaliar a temperatura de transição vítrea e a resistência à flexão da resina após a incorporação de TBAEMA. Material e método: Os espécimes foram divididos em cinco grupos de acordo com as concentrações de TBAEMA incorporadas à resina Onda-Cryl: 0%, 1%, 2%, 3% e 4%. A superfície dos espécimes foi avaliada por meio de Espalhamento Superficial de Elétrons com Análise Química (XPS-ESCA) para detectar a presença de grupos amina, representado por índices de nitrogênio. As análises de Espectroscopia de Infravermelho por Transformada de Fourier (FTIR) e Calorimetria Diferencial de Varredura (DSC) foram utilizadas para avaliar o processo de polimerização da resina 17 acrílica na presença do TBAEMA e a influência da incorporação do TBAEMA na temperatura de transição vítrea (Tg) da resina, respectivamente. A resistência à flexão dos espécimes também foi avaliada e os resultados foram analisados por meio de análise de variância a um fator (ANOVA) seguido pelo teste de Tukey ( <0.05). Resultados: Foram observados diferentes índices de nitrogênio: 0,36%, 0,54%, 0,35% e 0,20% para... / With a purpose of to prevent oral infections and therefore improve the quality of life of dentures wearers, several attempts to incorporate antimicrobial agents into acrylic resins have been reported in the literature. The incorporation of 2-tert-butylaminoethyl methacrylate (TBAEMA) into denture base acrylic resin would be a plausible alternative in order to reduce or eliminate colonization of that surface by pathogenic microorganisms, on this account this substance has amine groups in their composition, which could indicate a possible antimicrobial activity of the denture base. Purpose: The purpose of this study was to investigate the chemical interaction between the TBAEMA and acrylic resin and the presence of amine groups in the resin surface, and assess the glass transition temperature and flexural strength of the resin after the incorporation TBAEMA. Material and Method: The specimens were divided in five groups according to the concentration of TBAEMA incorporated to Onda-Cryl: 0%, 1%, 2%, 3% and 4%. Specimens surfaces were evaluated by Electron Spectroscopy for Chemical Analysis (ESCA) to detect the presence of amino groups, represented by nitrogen ratios. Fourier Transform Infrared Spectroscopy (FTIR) and Differential Scanning Calorimetry (DSC) analysis were used to evaluate the polymerization process of acrylic resin in the presence of TBAEMA and the influence of the incorporation of TBAEMA on the glass transition temperature (Tg) of acrylic resin, respectively. Flexural strength of the... (Complete abstract click electronic access below)
294

Obtenção de compósitos de borracha natural com resíduo industrial de couro reticulados com diferentes peróxidos /

Santos, Renivaldo José dos. January 2014 (has links)
Orientador: Aldo Eloizo Job / Banca: José Antonio Malmonge / Banca: Ana Maria Pires / Banca: Eduardo Ribeiro de Azevedo / Banca: Maria Alice Martins / Resumo: Processos de curtimento de couro têm causado impacto ambiental como resultado da geração de resíduo sólido, resíduos provenientes do processo de lavagem do couro (waterwaste) bem como a liberação de gases durante os procedimentos. O descarte inapropriado deste resíduo pode promover, por exemplo, a oxidação do cromo, passando de Cr III para Cr IV, tornando-se extremamente tóxico. Além disso, o descarte apropriado do resíduo (principalmente o resíduo sólido) em aterros regularizados aumenta consideravelmente o custo de produção para a indústria de couro. Baseado nestas informações, esta tese de doutorado, reporta um método de reciclagem de resíduo industrial de couro (coletado na região de Presidente Prudente) implementado na preparação de compósitos de borracha natural, variando a quantidade de resíduo incorporado nos compósitos de 40 e 80 phr, bem como avaliado o uso de diferentes agentes de vulcanização, os quais são peróxido de dicumila (DCP), peróxido 2,5 Dimetil Hexano 2,5 Di Terc-Butil, (DHBP) e enxofre (S), todo obtidos comercialmente. Os compósitos foram preparados sob alta pressão e nas de temperaturas de 150 e 180ºC. A caracterização foi realizada utilizado reometria, cálculo de energia da ativação aparente, determinação da densidade de ligações cruzadas por inchamento e ressonância magnética nuclear, ensaio de envelhecimento acelerado, resistência a tração na ruptura, resistência a abrasão, dureza Shore A, microscopia eletrônica de varredura (MEV), espectroscopia por FT-IR no modo ATR, calorimetria exploratória diferencial (DSC), termogravimetria (TG) acoplada a espectroscopia no infravermelho (TG/FTIR), análise dinâmica mecânica (DMA) e lixiviação. O principal resultado demonstra que aumentando a quantidade de resíduo de couro aumenta-se a tensão de ruptura e resistência ao desgaste, apresentando boa reprodutibilidade bem como uniformidade na distribuição do resíduo... / Abstract: Leather tanning processes have occasioned environmental impact as a result of the generation of solid waste, wasterwater and release of gases during the procedures. The improper disposal of such waste may promote the oxidation of chromium, increasing the Cr III to Cr IV, in which becomes extremely toxic. Furthermore, the appropriate disposal of the residue (mainly solid residue) at regularized landfil increase substantialy the production cost to the leather industry. Based on this information, this Ph.D. thesis reports a new method to recycling industrial leather waste (collected around Presidente Prudente city) implemented on preparation of natural rubber composites varying the amount of residue between 20 and 80 phr as well as evaluating different curing agents (crosslink generation) using dicumyl peroxide (DCP), peroxide 2,5 Dimethyl Hexane 2.5 Di Tert. Butyl (DHBP) and sulfur (S) obtained commercially. The composites were prepared under high pressure at a range of temperature of 150 to 180ºC. Moreover, the characterization was performed using, rhemetry, calculation of the apparent activation energy, determination of crosslink density by swelling and nuclear magnetic resonance, accelerated aging tests, stress-strain tests (rupture resistance at break), abrasion resistance, hardness Shore A, scanning electron microscopy (SEM), FT-IR spectroscopy in ATR mode, differential scanning calorimetry (DSC), thermalgravimetric (TG) coupled to infrared spectroscopy (TGA/FTIR), dynamic mechanical analysis (DMA) and evaluation of the leaching compounds. The main result showed that increasing the waste leather amount increased the tensile strength and abrasion resistance, with good reproducibility and uniformity of residuals distribution as fillers (miscible materials). The production of the natural rubber/leather waste composite lead to a correct management to the leather waste into a viable industrial application, eliminating a major... / Doutor
295

Base metal equilibrium prediction on ion exchange resin

Rejaldien, Moegamat Zain January 2002 (has links)
Thesis (MTech (Chemical Engineering)--Cape Technikon, Cape Town, 2002 / This study is the first phase of an investigation into an alternative process to recover base metals from solution, namely ion exchange. An identified ion exchange resin was employed to study the recovery of copper, nickel and cobalt from electrolytic solutions. The main focus of the investigation was the prediction of equilibrium conditions in this multi-component system using a batch configuration. In order to predict equilibrium conditions. existing multi-component isotherms such as Fritz and Schleunder were tested. It has been shown that traditional isothem15 did not accurately predict equilibrium conditions. hence the need for development of new isotherms. Essentially two approaches were followed in the development of new isotherms namely. an effective concentration approach as well as a heat transfer approach. Both yielded positive outcomes with the effective concentration approach proving to be the most accurate. In addition to these two approaches a thermodynamical approach was also tested which also showed favourable predictions for Cu loading
296

The recovery of metal cyanides by ion exchange resins

Strangfeld, Vinzenz Klaus January 2000 (has links)
Thesis (MTech (Chemical Engineering))--Cape Technikon, Cape Town, 2000 / Cyanide is used extensively in the mining industry to leach gold and silver from their ores. Cyanide, in the form of sodium or potassium cyanide, is added in excess to that required theoretically due to equilibrium and kinetic considerations in the leaching step. This results in free cyanide and various other cyanide complexes reporting to the effluent streams of these operations In this study the removal of these species from solution by means of ion exchange resins was investigated Equilibrium conditions, kinetic parameters and the competitive exchange nature of the process was evaluated. The experimental work focused on contacting the various resins individually in a batch reactor with free cyanide, Iron cyanide and copper cyanide complexes. The experimental data obtained was found to be well explained by the Freundlich-type multiand single-component isotherms. Furthermore, mass transfer parameters were investigated revealing that ceI1ain cyanide species outperform others kinetically in the ion exchange process. During this study it was shown that ion exchange processes could be effective in effluent clean-up of those streams containing cyanide complexes
297

Desorption of lithium 7 isotope from a degraded amberlite lithiated mixed-bed-resin

Basitere, Moses January 2011 (has links)
Thesis (MTech (Chemical Engineering))--Cape Peninsula University of Technology, 2011. / Lithium 7 (⁷Li⁺) is an isotope, which is used in the nuclear industry as lithium hydroxide (⁷LiOH) for the chemical control (pH control) of the high purity reactor coolant water process in order to prevent corrosion in the Pressurised Water Reactor (PWR). Furthermore, the ⁷Li⁺ isotope is used in an ionic form in the nuclear grade cation ion-exchange resin. This resin is used to purify the nuclear reactor coolant water by reducing cationic corrosion by-products such as Cesium and Cobalt, which are generated from nuclear fission reactions. In view of the fact that an inorganic salt of the isotope is used as an alkali sing agent in the PWR, the use of lithiated resin prevents the removal of the ⁷Li⁺ isotope in the coolant water. As most users of the nuclear grade resin purchase their resin in bulk, it follows that the resin has to be evaluated in order to determine its usability. In certain cases, the resin may be considered unusable as a result of the degradation caused by unsuitable transportation and storage conditions. These, in turn, perpetuate the release of leachates, which may further contribute to corrosion in the PWR. This necessitated the undertaking of this study, which was to evaluate whether it is possible to recover the high value ⁷Li⁺ isotope from a degraded nuclear grade resin in such a way that the isotope may be used in the PWR.
298

Avaliação do efeito da fumaça do cigarro na translucidez da resina composta : influência do selante da superfície e da escovação /

Takeuchi, Cristina Yoshie Garcia. January 2004 (has links)
Orientador: Welingtom Dinelli / Banca: José Roberto Cury Saad / Banca: Regina Guenka Palma Dibb / Resumo: O objetivo deste estudo foi avaliar in vitro a translucidez da resina composta, em função do efeito do selamento superficial; da exposição à fumaça de cigarro e da escovação. Para tanto, 40 corpos-de-prova (10 mm X 1 mm) foram confeccionados com resina composta Filtek Z250 divididos aleatoriamente em 4 grupos (n=10), sendo: G1 - controle (saliva artificial e sem selante); G2 - saliva artificial e com selante (Protect-it!); G3 - cigarro e sem selante e G4 - cigarro e com selante. Os espécimes foram submetidos à avaliação da translucidez em diferentes tempos: T1: imediatamente após a confecção; T2: após o polimento; T3: após o selamento (G2 e G4); T4: após o 1º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T5: após serem submetidos a 1ª escovação (850 ciclos); T6: após o 2º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T7: após serem submetidos a 2ª escovação (850 ciclos); T8: após o 3º tratamento (10 dias imersos em saliva artificial ou manchados por 200 cigarros); T9: após serem submetidos a 3ª escovação (850 ciclos). Os valores de translucidez foram obtidos no aparelho JOUAN e analisados estatisticamente pelos testes de Mann-Whitney, Kruskal-Wallis, Friedman, seguidos da Análise de Variância e teste de Tukey. Observou-se que o selamento não provocou alteração significativa da translucidez dos espécimes e que após a 1ª escovação ocorreu aumento significativo, mantendo-se constante nos G1 e G2, e para os G3 e G4 o cigarro provocou severo manchamento que foi removido parcialmente pela escovação. Concluindo que o selamento não promoveu melhora na translucidez com o tempo e nem protegeu contra manchamento, sendo que a escovação não restabeleceu a translucidez. / Abstract: The aim of this study was to assess in vitro the translucency of the composite resin, in function of the effect of the surface sealing; after the exposition to the cigarette smoke and of the toothbrushing. Forty specimens (10mm X 1mm) they were made with composite resin Filtek Z250 divided into 4 groups (n = 10), being: G1 - it controls (it artificial saliva and without sealant); G2 - it artificial saliva and with sealant (Protect-it!); G3 - cigarette and without sealant and G4 - cigarette and with sealant. The specimens were submitted to the evaluation of the translucency in different times: T1: immediately after the making; T2: after the polishing; T3: after the sealing (G2 and G4); T4: after the 1st treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T5: after they be submitted to 1st toothbrushing (850 cycles); T6: after the 2nd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T7: after they be submitted to 2nd toothbrushing (850 cycles); T8: after the 3rd treatment (10 submerged days in artificial saliva or spotted for 200 cigarettes); T9: after they be submitted to 3rd toothbrushing (850 cycles). The translucency values were obtained in the JOUAN apparel and analyzed by the tests of Mann-Whitney, Kruskal-Wallis and Friedman, following by the Analysis of Variance and test of Tukey. It was observed that the sealing didn't provoke significant alteration of the translucency of the specimens and that after to 1st toothbrushing it happened significant increase, staying constant in G1 and G2, and for G3 and G4 the cigarette provoked severe staining that was removed partially by the toothbrushing. Concluding that the sealing didn't promote improvement in the translucency with the time and nor it protected against staining, and the toothbrushing didn't reestablish the translucency. / Mestre
299

Influência da fonte de luz na estabilidade de cor de resina composta. Efeito dos meios e tempos de imersão /

Santos, Patrícia Aleixo dos. January 2008 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência da fonte de luz na estabilidade de cor da resina composta nanoparticulada Filtek Supreme submetida a diferentes meios e tempos de imersão. Para isso, foram utilizadas três fontes de luz: um LED UltraLume LED 5/ UltraDent; um aparelho de lâmpada halógena convencional - Curing Light XL 3000/ 3M/ESPE; e um de luz halógena de alta densidade de potência - Jet Lite 4000 Plus/ JMorita. Os espécimes (n=180) foram confeccionados em matriz de metal circular (10mm x 2mm) apoiada em placa de vidro e tira de poliéster. A resina composta foi inserida na matriz num único incremento e fotoativada por 40 segundos. Os espécimes foram divididos em três grupos (equipamento de fotopolimerização) e quatro subgrupos experimentais (meios de imersão: café, Coca-Cola®, chá e saliva artificial). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor no espectrofotômetro de colorimetria (CB-6807 color-guide /BYK-Gardner) pelo sistema CIELab. A partir desse período, passaram a ser mergulhados nos diferentes meios por cinco minutos, três vezes ao dia, por 60 dias, e nos intervalos foram mantidos em estufa à 37°C ± 1°C. A leitura da alteração de cor foi realizada após 24 e 48 horas, 7, 14, 21, 30 e 60 dias do início da imersão. Os dados foram analisados pelo teste não-paramétrico Kruskall-Wallis para os fatores fonte de luz e meio de imersão (p<0,05), enquanto, para o fator tempo, utilizou-se o teste ANOVA a dois critérios e o teste de Fisher (p<0,05). Os resultados mostraram que, para o fator fonte de luz, o Ultralume LED 5 apresentou a menor alteração de cor em comparação aos aparelhos halógenos. Em relação ao meio de imersão, o café mostrou a maior alteração de cor e de luminosidade (ΔE=8,40; _L=-5,21), a Coca-Cola® apresentou os menores valores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of light sources on color stability of a composite resin and the effect of immersion media. In this test, three light sources were used: a conventional halogen curing light unit (XL3000 - 3M/ESPE), a high power density halogen unit (Jet Lite 4000 Plus - JMorita) and a high power density LED unit (Ultralume LED 5 - Ultradent). There were four media immersion: coffee, tea, Coke® and artificial saliva. One nanofilled composite resin was selected: Filtek Supreme. A stainless steel matrix (10mmx2mm) was used to prepare 180 specimens. After this, all specimens were immersed in artificial saliva for 24hs at 37oC ± 1ºC and its initial color was measured with a spectrophotometer (Color Guide 45/0, BYKGardner) by CIELab system. Then, the specimens were divided into 4 subgroups according to each medium and were immersed in the respective medium three times a day during 5 minutes for 60 days. Color changes were recorded after 24hs, 48hs, 7, 14, 21, 30 and 60 days of immersion. Data from the color change and luminosity were analyzed and subjected to Kruskall-Wallis test to light source and immersion media factor (p<0,05). To immersion time, data were subjected to two-way ANOVA test and Fisher's test (p<0,05). The light source that more contributed to color stability was Ultralume LED 5. In relation to solutions, coffee caused an intense color alteration (ΔE=8,40; ΔL=-5,21) and Coke® showed the lowest color changes (ΔE=1,43; ΔL=0,36). Then, it might be concluded that Ultralume LED 5 was the light-curing unit that allowed better color stability and coffee was the immersion medium that promoted the highest influence on color stability of the studied composite resin. / Orientador: Patrícia Petromilli Nordi Sasso Garcia / Coorientador: Regina Guenka Palma-Dibb / Banca: Flávia Magnani Bevilacqua / Banca: Silmara Aparecida Milori Corona / Banca: Marcelo Ferrarezi de Andrade / Banca: Welingtom Dinelli / Doutor
300

Incorporação do metacrilato 2-tert-butilaminoetil a uma resina acrílica para a base protética: caracterização química e efeito sobre a resistência flexural /

Rodriguez, Larissa Santana. January 2011 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Banca: Ana Carolina Pero Vizoto / Resumo: A fim de prevenir infecções bucais e consequentemente melhorar a qualidade de vida dos usuários de prótese, diversas tentativas de incorporar agentes antimicrobianos a resinas acrílicas tem sido relatadas na literatura. A incorporação do metacrilato 2-tert-butilaminoetil (TBAEMA) a uma resina acrílica para base protética seria uma alternativa plausível no intuito de se reduzir ou eliminar a colonização dessa superfície por microrganismos patogênicos, pois esta substância apresenta grupos amina em sua composição, o que poderia indicar uma possível atividade antimicrobiana da base protética. Objetivo: O objetivo deste trabalho foi investigar a interação química entre o TBAEMA e a resina acrílica bem como a presença de grupos amina na superfície da resina, e ainda avaliar a temperatura de transição vítrea e a resistência à flexão da resina após a incorporação de TBAEMA. Material e método: Os espécimes foram divididos em cinco grupos de acordo com as concentrações de TBAEMA incorporadas à resina Onda-Cryl: 0%, 1%, 2%, 3% e 4%. A superfície dos espécimes foi avaliada por meio de Espalhamento Superficial de Elétrons com Análise Química (XPS-ESCA) para detectar a presença de grupos amina, representado por índices de nitrogênio. As análises de Espectroscopia de Infravermelho por Transformada de Fourier (FTIR) e Calorimetria Diferencial de Varredura (DSC) foram utilizadas para avaliar o processo de polimerização da resina 17 acrílica na presença do TBAEMA e a influência da incorporação do TBAEMA na temperatura de transição vítrea (Tg) da resina, respectivamente. A resistência à flexão dos espécimes também foi avaliada e os resultados foram analisados por meio de análise de variância a um fator (ANOVA) seguido pelo teste de Tukey ( <0.05). Resultados: Foram observados diferentes índices de nitrogênio: 0,36%, 0,54%, 0,35% e 0,20% para... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With a purpose of to prevent oral infections and therefore improve the quality of life of dentures wearers, several attempts to incorporate antimicrobial agents into acrylic resins have been reported in the literature. The incorporation of 2-tert-butylaminoethyl methacrylate (TBAEMA) into denture base acrylic resin would be a plausible alternative in order to reduce or eliminate colonization of that surface by pathogenic microorganisms, on this account this substance has amine groups in their composition, which could indicate a possible antimicrobial activity of the denture base. Purpose: The purpose of this study was to investigate the chemical interaction between the TBAEMA and acrylic resin and the presence of amine groups in the resin surface, and assess the glass transition temperature and flexural strength of the resin after the incorporation TBAEMA. Material and Method: The specimens were divided in five groups according to the concentration of TBAEMA incorporated to Onda-Cryl: 0%, 1%, 2%, 3% and 4%. Specimens surfaces were evaluated by Electron Spectroscopy for Chemical Analysis (ESCA) to detect the presence of amino groups, represented by nitrogen ratios. Fourier Transform Infrared Spectroscopy (FTIR) and Differential Scanning Calorimetry (DSC) analysis were used to evaluate the polymerization process of acrylic resin in the presence of TBAEMA and the influence of the incorporation of TBAEMA on the glass transition temperature (Tg) of acrylic resin, respectively. Flexural strength of the... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0604 seconds