• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 542
  • 376
  • 73
  • 29
  • 16
  • 16
  • 16
  • 16
  • 14
  • 11
  • 10
  • 10
  • 10
  • 10
  • 10
  • Tagged with
  • 1209
  • 519
  • 417
  • 343
  • 252
  • 211
  • 184
  • 139
  • 136
  • 113
  • 105
  • 95
  • 86
  • 76
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Influência da utilização de uma fibra de nylon modificada na resistência à flexão e alteração dimensional de resinas acrílicas /

Gonçalves, Fernanda de Cássia Papaiz. January 2012 (has links)
Orientador: Tarcísio José de Arruda Paes Júnior / Banca: Eduardo Shigueyuki Umera / Banca: Murilo Baena Lopes / Resumo: O propósito desta pesquisa foi avaliar o comportamento das resinas acrílicas quando reforçadas por fibras de nylon. Para tanto uma resina acrílica termoativada (RAAT) em microondas (Vipi-Wave - Vipi Dental Ltda.) e uma resina ativada quimicamente rígida para reembasamentos (Tokuso-Tokuyama) foram testadas quanto à resistência a flexão e alteração dimensional. Corpos de prova em formato de barra nas dimensões de 20x10x3 mm (n=9) foram analisados para a resistência a flexão nas seguintes situações: RAAT com ou sem fibra de nylon (modificada ou não por sílica) e, RAAT com reembasador de modo similar ao citado anteriormente. Teve-se ainda para outros grupos estabelecidos a realização de ciclagem termomecânica dos espécimes. Na observação da alteração dimensional fez-se comparação da distância entre pontos pré-determinados em dentes artificiais posicionados em próteses totais do arco maxilar (n=6) e que foram submetidos à ciclagem térmica prévia. Quanto aos tipos de testes, a resistência à flexão em três pontos foi mensurada em máquina de ensaio universal e os resultados dados em megapascal (MPa). Na análise da alteração dimensional foi feita a captura de imagens oclusais antes e após polimerização das próteses totais e ensaio para programa Image Tool e os resultados dados em milímetros. Os valores obtidos foram compilados e submetidos aos testes estatísticos ANOVA e Tukey (5%), confirmando que a adição da fibra de nylon modificada aumentou substancialmente a resistência à flexão e diminuiu a alteração dimensional da resina acrílica, independentemente dessa ser reembasada(AU) / Abstract: The aim of this study was to evaluate some properties of acrylic resins when reinforced by a nylon fiber. A microwave heat cured acrylic resin (RAAT) (Vipi-Wave) and a hard self cured acrylic resin for rebasing (Tokuso) were tested for flexural strength and dimensional stability. Specimens bar shaped 20x10x3mm (n=9) were analyzed for flexural strength in following situations: RAAT containing or not nylon fibers (modified or not by silica), and RAAT rebased with hard liner. In another groups thermal mechanical cycling of the specimens was realized. Dimensional stability was checked by analyses of predetermined points measurement on artificial teeth in upper complete dentures (n=6) and that also was submitted prior to thermocycling and the groups were established in the same conditions related previously reported. To flexural strength three points bending test was used in a universal testing machine and the results obtained in MPa. Dimensional stability measurement was made to capture occlusal images before and after polymerization of prosthesis and scanned for the Image Tool. Data analysis were compiled, distributed and comparatively evaluated by ANOVA and Tukey test (5%). Confirming the adding of the modified nylon fiber has substantially increased the flexural strength and decreased dimensional change of acrylic resin, whether this be rebased(AU) / Mestre
302

Eficácia da imersão e da escovação mecânica combinada com diferentes agentes de limpeza de prótese na redução da viabilidade de biofilme multiespécies /

Panariello, Beatriz Helena Dias. January 2013 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Cláudia Pavarina / Banca: Cláudia Helena Lovato da Silva / Resumo: O objetivo deste estudo foi investigar a eficácia da escovação com diferentes agentes de limpeza para reduzir a viabilidade de um biofilme multiespécies em resinas acrílicas. Amostras de Lucitone 550 (L) e Tokuyama Rebase Fast II (T) (10 mm x 2 mm) foram preparadas, esterilizadas e inoculadas com uma suspensão de 107 células/mL de Candida albicans e Candida glabrata e de 108 células/mL de Streptococcus mutans. As amostras foram incubadas por 48 h a 37 °C para a formação do biofilme. Em seguida, foram divididas (n = 12) e submetidas à escovação ou imersão durante 10 s nas soluções: água destilada (A); ácido peracético 0,2% (Ac), digluconato de clorexidina 1% (Chx), solução água/dentifrício 1:1 (D), hipoclorito de sódio a 1% (NaOCl) e perborato de sódio (Pb). Os microrganismos viáveis foram avaliados por ensaio de XTT e contagem de colônias (ufc /mL). Os dados foram verificados por ANOVA e teste de Tukey com nível de significância de 5%. Neste estudo, a eficácia da remoção do biofilme foi aumentada pela escovação combinada com agentes químicos de limpeza, por outro lado, a imersão por 10 s em AC e NaOCl mostrou-se tão eficaz quanto a escovação em L e T. Este resultado é bastante interessante, pois a imersão nestes agentes de limpeza por um curto período poderia ser uma alternativa viável para a desinfecção de próteses de pacientes com dificuldades motoras para executar a escovação. / Abstract: The aim of this study was to investigate the efficacy of brushing with different cleaning agents in reducing the viability of multispecies biofilm in acrylic resins. Lucitone 550 (L) and Tokuyama Rebase Fast II (T) specimens (10 mm x 2 mm) were prepared, sterilized and inoculated with a Candida albicans and Candida glabrata suspension of 107 cells/mL and a suspension of 108 cells/mL of Streptococcus mutans. Specimens were incubated for 48 h at 37°C for the biofilm formation. Then, they were divided (n=12) and subjected to brushing or immersion for 10 s in the solutions: distilled water (W), 0.2% peracetic acid (Ac), 1% chlorhexidine digluconate (Chx), 1:1 water/dentifrice solution (D), 1% sodium hypochlorite (NaOCl) and sodium perborate (Pb). Viable microorganisms was evaluated by XTT assay and colony counts (cfu/mL). Data were performed by ANOVA and Tukey test with 5% significance level. In this study, the efficacy of biofilm removal was increased by brushing combined with chemical cleaning agents, on the other hand, immersion for 10 sec in NaOCl and AC has shown to be as effective as brushing for L and T. This result is quite interesting, inasmuch as immersion in these cleaning agents for a short period could be a viable alternative for prostheses disinfection of patients with motor disabilities to perform the brushing. / Mestre
303

Alteração dimensional da base de protese total superior e inferior, sob influencia da inclusão em mufla dupla / Dimensional change of the maxillary and mandibular denture base under influence of double flask

Zampieri, Marinaldo Henrique 20 February 2008 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T13:00:28Z (GMT). No. of bitstreams: 1 Zampieri_MarinaldoHenrique_M.pdf: 729614 bytes, checksum: 67cd861fbbbca6e4ac88c4d28cbc4975 (MD5) Previous issue date: 2008 / Resumo: O propósito deste trabalho foi estudar o efeito de muflas metálicas (convencional e mufla dupla experimental SR) e do tempo pós-prensagem (imediato e 6 horas) no nível de adaptação de bases de prótese total superior e inferior confeccionadas com resina acrílica Clássico ativada termicamente. Foramconfeccionados 80 conjuntos modelo de gesso-base de cera distribuídos aleatoriamente em 6 grupos (n=10), de acordo com o tipo de mufla metálica e do tempo pós-prensagem. A resina acrílica foi proporcionada e manipulada de acordo com as instruções do fabricante e prensada na fase plástica com carga inicial de 850 kgf e final de 1.250 kgf em prensa hidráulica de bancada. As bases foram polimerizadas em ciclo de água a 74°C por 9 horas. Depois do esfriamento das muflas até atingir a temperatura ambiente, as bases foram desincluídas, acabadas, fixadas nos respectivos modelos de gesso com adesivo à base de cianoacrilato e seccionados em três secções, correspondentes a distal de caninos (A), mesial de primeiros molares(B) e região palatina posterior(C). Em cada conjunto, o desajuste entre o modelo de gesso e a base de resina foi verificado nos seguintes pontos referenciais: 1- base superior: fundo do sulco vestibular direito e esquerdo, crista do rebordo alveolar direita e esquerda e linha mediana palatina; 2- inferior: fundo do sulco vestibular esquerdo e direito, crista do rebordo alveolar direita e esquerda, e fundo de sulco lingual direito e esquerdo. O desajuste foi verificado com microscópio comparador linear Olympus, com precisão de 0,0005mm. Os dados coletados foram submetidos à análise de variância e ao teste de Tukey (5%). Os resultados mostraram que houve diferença estatística significante entre as secções, onde A apresentou o melhor resultado, C o pior resultado e B demonstrou valor intermediário, para as bases superior e inferior. Na base de prótese superior, os tempos pós-prensagem em cada tipo de região e tipo de mufla mostraram diferença estatística, exceto na região A, para a mufla simples. Na comparação entre tipos de mufla para cada região no tempo imediato houve diferença estatística significante para todas as regiões. No tempo pós-prensagem de 6 horas não houve diferença estatística em todas as comparações. Entre os tipos de região para cada tempo pósprensagem da base inferior, o tempo imediato demonstrou diferença estatística em todas as regiões, quando o tipo de mufla foi comparado. O tempo de espera de 6 horas não mostrou diferença estatística entre as regiões e tipos de muflas / Abstract: The purpose of this work was to study the use of flask closure (conventional metallic flask closure nº5,5 and double SR flask closure.), regarding the adaptation of the prothesis'base (immediate and after six hours) in the upper total prothesis base and also the inferior total prothesis base adaptation. Both prothesis were made of acrylic resin activated by temperature (Classic®). 80 gypsum models were manufactured with wax base randomly distributed in 8 groups (n=10), according to the type of metallic flask closure used and the time that the prothesis remained under pressure (immediate or after six hours). The resin was proportionate and manipulated according to the manufacturer instructions and it was put under pressure in the plastic phase, starting with 850 Kgf until 1250 Kgf utilizing the hydraulic press of workbench. The bases were manufactured and polymerized in water cycle at 74°C for 9 hours. After they reached room temperature, the bases were removed, finished, and replaced in its respective models using cianocrilato adhesive on the base. The models were divided into three sections, corresponding to distal of canines, mesial of first molars and posterior palate region. In each model, the superior and lower maladjustment between the gypsum model and the resin base was verified in the reference points mention above; Superior model: bottom of vestibular sulcus (right and left sides), alveolar crest (right and left sides) and average line of the palate. Lower model: bottom of vestibular sulcus (right and left sides), crest of the edge alveolar crest (right and left sides) and bottom of lingual sulcus (right and left sides). In each section, the maladjustment between the model and resin base was verified with an Olympus comparative linear microscope, with 0,0005mm accuracy. The data were collected and submitted to analysis of variance and to the test of Tukey (5%). The test results demonstrated a significant statistical difference between the sections, where section A showed the best result, C the worst, and B showed an intermediate value, for the lower and upper bases of the prothesis. In the base of the upper prosthesis, the time that the material was under pressure in each region and type of flask closure showed statistical difference, except in region A, for the simple flask closure. In the comparison between types of flask closure for each region in the immediate time showed significant statistical difference for all the regions. There was no statistical difference during the time the material was under pressure (6 hours) for all comparisons. When the types of flask closure were compared regarding region types for each time the lower base was under pressure, the immediate time showed statistical difference in all the regions. There was no statistical difference between the regions and types of flask closure after a period of six hours / Mestrado / Protese Dental / Mestre em Clínica Odontológica
304

Desenvolvimento de materiais resinosos para infiltração em lesões cariosas incipientes em esmalte = avaliação do grau de conversão, densidade de ligações cruzadas e módulo de elasticidade / Development of resin materials in incipient enamel caries infiltration : evaluation of the degree of conversion, cross-linking density and elastic modulus

Araújo, Giovana Spagnolo Albamonte de, 1986- 18 August 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T06:18:48Z (GMT). No. of bitstreams: 1 Araujo_GiovanaSpagnoloAlbamontede_M.pdf: 1946748 bytes, checksum: 9a2061ac19b3f6740cb5cf8d0e2c07d5 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste trabalho foi avaliar o grau de conversão, densidade de ligações cruzadas e módulo de elasticidade de nove materiais resinosos experimentais contendo diferentes combinações de monômeros base e diluentes em comparação a um material comercialmente disponível,. Além disso, avaliar o módulo de elasticidade após aplicação em esmalte bovino cariado artificialmente. Foram preparados nove materiais resinosos experimentais contendo TEGDMA, BISEMA, HEMA, UDMA e etanol em diferentes proporções. O grau de conversão monomérico foi avaliado através da Espectroscopia Transformada por Infravermelho de Fourier (FTIR). A densidade de ligações cruzadas foi avaliada indiretamente através da taxa de redução de dureza após imersão em etanol. O módulo de elasticidade foi avaliado através do teste de flexão de três pontos para avaliação do módulo de elasticidade, utilizando máquina de ensaio universal (Instron). Adicionalmente, o módulo de elasticidade do esmalte bovino cariado e infiltrado com os materiais experimentais foi avaliado. Para tanto, blocos de esmalte bovino com 4mm x 2mm x 1mm foram preparados e submetidos ao desenvolvimento de cárie artificial. Os infiltrantes foram aplicados e o módulo de elasticidade foi determinado através do teste de flexão de três pontos em máquina de ensaio universal (Instron). Os resultados foram submetidos a dois tipos de análise, sendo a primeira ANOVA e teste de Tukey (5%), em que é feita a comparação entre os grupos experimentais. A segunda análise, os dados foram submetidos a ANOVA e teste de Dunnett (5%), em que é feita a comparação entre o grupo controle e os experimentais. Os materiais contendo etanol na composição apresentaram resultados inferiores em todos os testes, e os sem solvente na composição apresentaram os melhores resultados. A adição de UDMA não influenciou as propriedades testadas, porém o BisEMA influenciou de forma negativa.O material resinoso contendo TEGDMA e o comercial apresentaram os maiores valores de grau de conversão comparando-se aos demais grupos. Em relação à densidade de ligações cruzadas, houve maior redução de dureza do grupo contendo TEGDMA, UDMA e etanol em comparação com o grupo controle (comercial). Os grupos que continham etanol na composição apresentaram os menores valores de módulo de elasticidade, sendo diferentes do grupo controle. Em relação ao módulo de elasticidade das amostras cariadas e infiltradas não houve diferença significativa entre os grupos infiltrados e o grupo controle (cariados) e nem entre os grupos experimentais. A adição de etanol e HEMA influenciou de forma negativa todas as propriedades testadas O TEGDMA como monômero base, sem adição de solvente apresentou-se como o infiltrante com melhores propriedades em todos os testes / Abstract: The aim of this study was to evaluate the degree of conversion, crosslink density and elastic modulus of nine experimental resin materials containing different combinations of base monomers and solvents on comparison to a material commercially available. Moreover, to evaluate the elastic modulus after application to artificially carious enamel. Were prepared nine experimental resin materials containing TEGDMA, BISEMA, HEMA, UDMA and ethanol in different proportions. The degree of conversion was measured by Fourier Transformed Infrared Spectroscopy (FTIR). The crosslink density was indirectly assessed by the rate of reduction of hardness after immersion in ethanol. The elastic modulus of was evaluated by three-point bending test to evaluate the elastic modulus, using a universal testing machine (Instron). Additionally, the elastic modulus of enamel caries and infiltrated with the experimental materials was evaluated. For that, bovine enamel blocks with 4mm x 2mm x 1mm were prepared and submitted to the development of caries. The experimental resin materials were applied and the elastic modulus was determined by three-point bending test in a universal testing machine (Instron). The results were subjected to two types of analysis, the first ANOVA and Tukey test (5%), in which a comparison is made between the experimental groups. The second analysis, data were analyzed by ANOVA and Dunnett's test (5%), in which a comparison is made between the control and experimental groups. The materials in the composition containing ethanol exhibited inferior in all tests, and the solvent-free composition showed the best results. The addition of UDMA not influence the properties tested, but the manner influenced BisEMA negativa.O resinous material containing commercial and TEGDMA showed the highest degree of conversion compared to the other groups. Regarding the crosslink density, a greater reduction of hardness of the group containing TEGDMA, UDMA and ethanol compared with the control group (commercial). The groups containing ethanol showed the lowest elastic modulus, being different from the control group. Regarding the elasticity of the samples infiltrated decayed and there was no significant difference between groups infiltrated and control group (decayed) or between experimental groups. The addition of ethanol, and HEMA influenced negatively all properties tested as the TEGDMA monomer base, without addition of solvent appeared as infiltrating the best properties in all tests / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
305

Estudos de purificacao de uranio por saturacao seletiva do cloreto de uranilo em resina anionica forte

GOCHNARG, ISRAEL 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:23:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:31Z (GMT). No. of bitstreams: 1 00939.pdf: 1759518 bytes, checksum: 13e7c7b34c66d55c7d42e8522a1cc678 (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
306

Purificacao do molibdenio-99 obtido a partir da fissao do uranio-235 utilizando-se a resina chelex-100

LAVINAS, TATIANA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:44Z (GMT). No. of bitstreams: 1 06437.pdf: 4468034 bytes, checksum: 590a8fa00a608b9ee7764f05c4eca4d1 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
307

Estudo comparativo in vitro da capacidade adesiva da resina fotoativada pela luz halogena e por laser de argonio, utilizando-se brackets metalicos em pre-molares humanos

CARILLO, VITORIA E.B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:49Z (GMT). No. of bitstreams: 1 09878.pdf: 6131893 bytes, checksum: 6f914465126a59ad76dc82dbeae6a39f (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
308

Influencia da cor na passagem de luz e relação com propriedades mecanicas de compositos / Influence of shade on light trannmission and mechanics propriety of resin composite

Guiraldo, Ricardo Danil 13 August 2018 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T02:07:33Z (GMT). No. of bitstreams: 1 Guiraldo_RicardoDanil_D.pdf: 566212 bytes, checksum: fb0b1aef64c61609d93e862d3667585d (MD5) Previous issue date: 2009 / Resumo: Para muitos tipos e tonalidades de resina composta, o grau de polimerização satisfatório não é alcançado através da espessura de 2 mm. A fim de tornar os objetivos do efeito da luz mais evidente, o estudo foi dividido em dois capítulos. Capítulo 1: O objetivo foi investigar a influência de diferentes cores de resinas compostas na transmissão de luz através do compósito e a diferença percentual de diminuição da dureza Knoop entre a base e o topo (PDD). Resinas compostas restauradoras (Filtek Z350 e Esthet X) foram utilizadas nas cores A1 e A3,5. A irradiância da unidade fotoativadora (LCU) foi mensurada com medidor de potência Ophir Optrônicos (780 mW/cm2). Vinte espécimes foram feitos para cada cor. Ensaios de transmissão da luz: A irradiância da luz que passou através dos compósitos foi mensurada (n=10). Ensaio de Dureza Knoop: A PDD do mesmo espécime foi calculado (n=10). Irradiância de luz que passou através do compósito cor A1 foi estatisticamente superior ao da cor A3,5 para ambos os compósitos (p=0,00001). Para Esthet X, a PDD da cor A3,5 foi estatisticamente maior do que a cor A1. Entretanto, para o Filtek Z350 não houve diferença significativa (p=0,03035). Diferentes resinas compostas influenciaram a transmissão da luz e a PDD. Cores escuras influenciaram a transmissão de luz, mas não estão necessariamente correlacionadas com a PDD. Capítulo 2: O objetivo foi investigar a influência de diferentes cores de resina composta na transmissão de luz através dos compósitos, dureza e densidade de ligação cruzada (DLC). O compósito Filtek Z250 foi utilizado nas cores A1, A3 e A3,5. A irradiância da unidade fotoativadora (LCU) foi mensurada com medidor de potência Ophir Optrônicos (900 mW/cm2). Trinta espécimes foram confeccionados para cada cor. Ensaios de transmissão da luz: a irradiância da luz que passou através dos compósitos foi mensurada (n = 10). A diferença na porcentagem de diminuição da dureza Knoop entre a base e o topo (PD) da mesma amostra foi calculada (n=10). A densidade de ligação cruzada foi calculada pelo amolecimento produzido pelo etanol, pelo decréscimo na dureza (n=10). A irradiância da luz que passou através do compósito na cor A1 foi estatisticamente superior que da cor A3, a qual também foi maior que da cor A3,5. A PDD da cor A3,5 foi estatisticamente maior que da cor A3, que também foi maior que a cor A1. Não houve diferença estatisticamente significativa na DLC. Cores escuras têm influência significativa na transmissão da luz através da resina composta e na dureza. Entretanto, a densidade de ligação cruzada não foi influenciada pelas cores mais escuras do compósito dental / Abstract: For many types and shades of resin, a high degree of cure is not achieved through a 2 mm thickness photo-activated resin composite. The study was divided into two Chapters in order to make the objectives clearer. Chapter 1: The aim was to investigate the influence of different composite resin shades on light transmission through the composite and the difference in percentage of decrease of Knoop hardness between bottom and top (PHD). Two restorative resin composites of shades A1 and A3.5 were used (Esthet X and Filtek Z350). Light curing unit (LCU) irradiance was measured with a power meter Ophir Optrônicos (780 mw/cm2). Twenty specimens were made for each color. Light transmission test: The irradiance of light that passed through the composite was measured. Knoop Hardness test: the PHD of the same specimen was calculated (n=10). Irradiance of light that passed through composite shade A1 was statistically higher than though shade A3.5 for both composite (p=0.00001). For Esthet X the PHD of shade A3.5 was statistically higher than that of shade A1 but for Filtek Z350 there was no difference (p=0.03035). Different composite resins influenced the light transmission and the PHD. Darker shades influenced the light transmission, but they are not necessarily correlated with the PHD. Chapter 2: The aim was to investigate the influence of different composite resin shades on light transmission through the composite, hardness and cross-link density (CLD). The composite Filtek Z250 was used in shades A1, A3 and A3.5. Light curing unit irradiance was measured with a power meter Ophir Optronics (900 mw/cm2). Thirty specimens were made for each shade. Light transmission test: Irradiance of light that passed through the composite was calculated (n=10). The difference in percentage of decrease of Knoop hardness between bottom and top (PHD) of the same specimen was calculated (n=10). The cross-link density was calculated by the softening effect produced by ethanol, by the decrease in hardness (n=10). Irradiance of light that passes through the composite shade A1 was statistically greater than though shade A3 that was also greater than though the shade A3.5. The PHD of shade A3.5 was statistically higher than that of shade A3, which that was also greater than that of shade A1. There was no statistically significant difference in CLD. Darker shades have a significant influence on light transmission through the dental resin composite and its hardness. However, the cross-link density was not affected by darker dental composite shades / Doutorado / Doutor em Materiais Dentários
309

Efeito de sucessivos ciclos de desinfecção por microondas sobre a microdureza e rugosidade superficial de diferentes bases de próteses totais: estudo longitudinal / Effect of successive microwave disinfection cycles on the hardness and roughness of different denture base resins: a longitudinal study

Flora Freitas Fernandes Távora 22 June 2007 (has links)
O objetivo desse estudo foi investigar longitudinalmente, o efeito de sucessivos ciclos de desinfecção sobre as propriedades de microdureza e rugosidade superficial de 4 diferentes resinas acrílicas. Foram confeccionados 200 corpos de prova, utilizando um material para base de dentaduras (Lucitone 550) e três materiais rígidos para reembasamento (Jet, Kooliner e Tokuyama Rebase II Fast), os quais foram divididos, para cada resina, em cinco grupos: imersos em água (controle) e submetidos à irradiação por microondas em quatro combinações diferentes de potência-tempo. Esses grupos foram avaliados em relação à rugosidade superficial (Ra-µm) e microdureza Knoop (KHN) em um período anterior às desinfecções e após 30, 90 e 180 ciclos de desinfecção. Os dados foram submetidos à análise de variância, seguida por teste de Tukey a 5%. As principais alterações nos valores de microdureza (diminuição) e rugosidade superficial (aumento) ocorreram após 30 ciclos de desinfecção em microondas. Após esse período existiu uma tendência para a estabilização dos valores dessas propriedades, mesmo quando ciclos adicionais (90 e 180 ciclos) foram realizados. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) não foram os principais fatores que tiveram influência sobre a propriedade de microdureza. É provável que a redução dos valores de microdureza tenha sido mais dependente da sorpção de água do que da energia de microondas por si só. O principal efeito sobre a microdureza através da irradiação por microondas parece ser o efeito da água. A exposição da prótese a fluidos como água e saliva é uma condição que não pode ser evitada. Esse comportamento não foi observado para a rugosidade superficial. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) tiveram influência sobre a propriedade de rugosidade superficial. De maneira geral observou-se que os valores de rugosidade superficial dos espécimes somente imersos em água foram menores do que os valores dos espécimes irradiados. Apesar da rugosidade de alguns espécimes ter ficado acima de 0.2 um, isso não parece contra-indicar a desinfecção por microondas. As técnicas convencionais de acabamento e polimento aplicadas para as outras superfícies dificilmente atingem níveis de rugosidade superficial inferiores a 0,2 µm. Dessa maneira parece ser prudente a afirmação de que a desinfecção através da energia de microondas pode ser utilizada para a desinfecção de próteses. / The objective of this study was to investigate the longitudinal effect of microwave disinfection on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 200 specimens were fabricated using one denture base material (Lucitone 550; n=50) and three hard chairside reliners (Jet; n=50, Kooliner; n=50, Tokuyama Rebase II Fast; n=50), which were immersed in water (control), and submitted to microwave disinfection at four different arrangements of power and time. These specimens were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before disinfection, after 30, 90 and 180 disinfection cycles). Data were analyzed by Variance Analysis which was followed by the Turkey\'s test at a level of 5%. The principal alterations on hardness (reduction) and on roughness (elevation) occurred after 30 disinfection cycles. Both of the properties remained stable after this period, even after 90 and 180 disinfection cycles. The different arrangements of power and time carried out for the experimental groups did not have influence on hardness. It is possible that this property was more affected from water sorption than microwave energy only. During its clinical use, the denture is exposed to water and saliva and it seems that this condition cannot be prevented. This fact was not observed for roughness. The different arrangements of power and time carried out for the experimental groups had influence on roughness. It was observed that the control group had lower roughness values when compared to the experimental groups. The roughness values of some specimens were greater than 0.2 um. However, this fact does not compromise the indication of microwave disinfection. The finishing and polishing techniques commonly used for the other surfaces of the denture do not get roughness values below 0.2 um. Therefore, it is very likely that microwave disinfection could be recommended for the disinfection of dentures.
310

Efeito da desinfecção química sobre a microdureza e rugosidade superficial de resinas para base de dentaduras e resinas rígidas para reebasamento: estudo longitudinal / Effect of chemical disinfection on the hardness and roughness of denture base resins and hard chairside resins: a longitudinal study

Luciana de Rezende Pinto 20 April 2007 (has links)
O objetivo deste estudo foi investigar, longitudinalmente, o efeito de cinco soluções desinfetantes sobre a microdureza e rugosidade superficial de uma resina acrílica termopolimerizável e três materiais reembasadores rígidos. Um total de 240 corpos de prova circulares (30 X 6mm) foram fabricados, utilizando um material para base de dentaduras (Lucitone 550; n=60), e três materiais rígidos, para reembasamento (Jet; n=60, Kooliner; n=60, Tokuyama rebase II fast; n=60), os quais foram imersos em água (controle), e em cinco soluções desinfetantes (hipoclorito de sódio a 1%, hipoclorito de sódio a 2%, hipoclorito de sódio a 5,25%, glutaraldeído a 2% e gluconato de clorexidina a 4%), e testados para avaliação de microdureza Knoop (KHN) e rugosidade superficial (Ra-µm) em diferentes intervalos (antes das imersões, após 30, 90 e 180 ciclos de desinfecção. Em cada condição experimental foram utilizados 10 corpos de prova de cada material estudado. Os dados foram analisados através de esquema fatorial (6X4) e as médias foram analisadas por meio de análise de variância, seguida por teste de Tukey a 5%. Para as resinas Lucitone 550 (20,61 ± 1,36 a 15,44 ± 1,26 KHN), Jet (18,74 ± 0,47 a 13,75 ± 0,95 KNH), Kooliner (14,09 ± 1,63 a 7,52 ± 0,88 KHN) e Tokuyama rebase II fast (12,57 ± 0,94 a 8,28 ± 0,39 KHN), foi observada uma diminuição significativa dos valores de microdureza, independente da solução utilizada, após 180 ciclos de imersão. Não foi observada interação significativa para a rugosidade da resina Kooliner. Para a resina Lucitone 550 (0,06 ± 0,01 a 0,20 ± 0,02µm) e Jet (0,07 ± 0,01 a 0,23 ± 0,04µm), foi observado aumento significativo dos valores de rugosidade superficial, independente da solução desinfetante utilizada, e a após 180 ciclos de imersão em água, estes materiais mantiveram valores semelhantes ao da avaliação inicial. A resina Tokuyama rebase II fast não mostrou diferenças significativas nos valores de rugosidade superficial quando imersa em água, hipoclorito de sódio a 2%, 5,25% e glutaraldeído a 2%, durante o período do estudo. Ao final da avaliação (180 ciclos), conclui-se que, embora todas as soluções tenham causado redução da microdureza da resina Lucitone 550, os espécimes submetidos às imersões em H5,25% e H2% apresentaram menores valores, no entanto, não ocorreu diferença significante entre os desinfetantes para as resinas autopolimerizáveis. As soluções H1%, H2% e GC4% causaram maior alteração na rugosidade superficial da resina Lucitone 550. Estas mesmas soluções, além de H5,25%, promoveram maior rugosidade na resina Jet, enquanto que, para a resina Tokuyama Rebase II fast, não houve diferença entre os desinfetantes. / The aim of this study was to investigate the longitudinal effect of five disinfection solutions on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 240 circular specimens (30 X 6mm) were fabricated using one denture base material (Lucitone 550; n=60) and three hard chairside reliners (Jet; n=60, Kooliner; n=60, Tokuyama rebase II fast; n=60), which were immersed in water (control), and five disinfecting solutions (1% sodium hypochlorite; 2% sodium hypochlorite; 5,25% sodium hypochlorite, 2% glutaraldehyde; 4% chlorhexidine gluconate) that were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before immersions, after 30, 90 and 180 immersion cycles). For each experimental condition, 10 specimens were used from each material. Data was analyzed by factorial scheme (6 X 4) and the means were analyzed by The Variance Analysis which was followed by Tukey\'s test 5%. For Lucitone 550 (from 20,61 ± 1,36 to 15,44 ± 1,26 KHN), Jet (from 18,74 ± 0,47 to 13,75 ± 0,95 KHN), Kooliner (from 14,09 ± 1,63 to 7,52 ± 0,88 KHN), Tokuyama rebase II fast (from 12,57 ± 0,94 to 8,28 ± 0,39 KHN) significant decrease in hardness was observed regardless of the solution used, after 180 immersion cycles. No significant interactions were observed for Kooliner roughness. Between Lucitone (from 0,06 ± 0,01 to 0,20 ± 0,02µm) and Jet, (from 0,07 ± 0,01 to 0,23 ± 0,04µm) there was a significant increase in roughness regardless of the disinfectant solution used; Jet showed significant increase in roughness after immersion in water for 180 cycles. Tokuyama rebase II fast showed no significant differences in roughness when immersed in water, 2% sodium hypochlorite, 5.25% sodium hypochlorite, and 2% glutaraldehyde after 180 cycles. In conclusion, this study showed that Lucitone 550 specimens exhibited significant decrease in hardness regardless of the disinfection solution used, and the specimens immersed in H5,25% and H2% showed lower hardness values; However, no significant differences were noted between all disinfectants solution, for hard chairside resins. The solutions H1%, H2% and GC4% caused more alteration in roughness of Lucitone 550. These solutions along with H5,25% caused an increase in the roughness of Jet, while with the Tokuyama rebase II fast there was no difference between the disinfection solutions.

Page generated in 0.0558 seconds