• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação de protocolos para colagem de bráquetes cerâmicos e remoção do adesivo remanescente com vistas á preservação da integridade de esmalte dentário/

Vianna, Alexandre Protásio. January 2013 (has links)
Orientador: Edson Alves de Campos / Banca: Ronald de Freitas Paixão / Banca: Patrícia Panizzi Gimenes Sakima / Banca: Luiz Gonzaga Gandini Júnior / Banca: Ary dos Santos-Pinto / Banca: / Resumo: Introdução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated... (Complete abstract click electronic access below) / Doutor
62

Efeito de diferentes concentrações de ascorbato de sódio na resistência de união ao esmalte clareado

Silva, Cristiano Pires e 06 February 2015 (has links)
Submitted by Kamila Costa (kamilavasconceloscosta@gmail.com) on 2015-06-24T20:51:58Z No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-08T18:16:12Z (GMT) No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-08T18:19:19Z (GMT) No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) / Made available in DSpace on 2015-07-08T18:19:19Z (GMT). No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) Previous issue date: 2015-02-06 / Não Informada / After completing the tooth bleaching, reaction products remain in the tooth structure not allowing the correct polymerization of adesives restorations. The purpose of this study was to investigate the antioxidants effects of sodium ascorbate hydrogel on the residual oxygen in the bovine enamel structure bleached with hydrogen peroxide and after restorated with composite resin. One hundred and twenty bovines teeth were divided into twelve groups (n: 10), the groups G1;G2;G3;G4;G5;G6 were subjected to a test of shear strength after one week, the groups G7;G8;G9;G10;G11;G12 were tested after six months (aged), being G1; G7 - restored without bleaching ; G2; G8 - bleached and restored after fourteen days; G3; G9 - bleached and restored at the same day; G4; G10 - bleached, treated with sodium ascorbate hydrogel of 10% and restored; G5; G11 - bleached, treated with sodium ascorbate hydrogel of 20% and restored and G6; G12 - bleached, treated with sodium ascorbate hydrogel of 40% and restored. The results of the shear test were subjected to two ANOVA’s criteria and Tukey's analysis to compare the scores (p≤ 0,05). The groups G1: 152,6N +- 21,2; G2: 183,2N +- 31,4; G5: 171,53N +- 20,6; G6: 179,9N +- 33,1 showed similar resistance to shear and the groups G3: 99,3N +- 33,9; G4: 101,3N +- 29,3 were statistically significant lower resistance. The second group had lower shear resistance, however maintained the same pattern of statistical difference between the groups. The aged groups G7: 98,1 +- 22,6; G8: 111,9 +- 34,0; G11: 91,9 +- 24,0; G12: 90,0 +- 13,1 showed lower shear resistance when compared to the non-aged. However, when compared between the aged, as well as between no-aged, the groups G9: 59,3 +- 19,9; G10: 59,7 +- 10,9 also showed lower resistance when compared to the others groups. We can conclude that the tooth bleaching with 35% hydrogen peroxide promoted reduction of the bond strength. In addition, treatment of the bleached enamel with 20% and 40% sodium ascorbate hydrogel allowed to reach values of bond strength similar of the enamel not bleached. / Após finalizar o tratamento de clareamento dentário os subprodutos da reação permanecem na estrutura dentária impedindo a correta polimerização das restaurações adesivas. O objetivo deste trabalho foi investigar os efeitos antioxidantes do hidrogel de ascorbato de sódio sobre o oxigênio residual na estrutura de esmalte bovino clareado com peróxido de hidrogênio e posteriormente restaurado com resina composta. Cento e vinte dentes bovinos foram divididos em 12 grupos (n=10), os grupos G1;G2;G3;G4;G5;G6 foram submetidos ao teste de cisalhamento após uma semana, os grupos G7;G8;G9;G10;G11;G12 foram testados após seis meses (envelhecimento), sendo G1;G7 - restaurado sem clareamento; G2;G8 - clareado e restaurado após 14 dias; G3;G9 - clareado e restaurado no mesmo dia; G4;G10 - clareado, tratado com hidrogel de ascorbato de sódio 10% e restaurado; G5;G11 - clareado, tratado com hidrogel de ascorbato de sódio a 20% e restaurado e G6;G12 - clareado, tratado com hidrogel de ascorbato de sódio a 40% e restaurado. Os resultados do teste de cisalhamento foram submetidos a ANOVA a 2 critérios e teste de Tukey para comparação das medias (p≤ 0,05). Os grupos G1: 152,6N +-­‐ 21,2; G2: 183,2N +-­‐ 31,4; G5: 171,53N +-­‐ 20,6; G6: 179,9N +-­‐ 33,1 apresentaram resistência ao cisalhamento semelhante e os grupos G3: 99,3N +-­‐ 33,9; G4: 101,3N +-­‐ 29,3 apresentaram resistência inferior estatisticamente significativa. O segundo grupo apresentou menor resistência ao cisalhamento porém, mantive o mesmo padrão de diferença estatística entre os grupos. Os grupos envelhecidos G7: 98,1N +- 22,6; G8: 111,9N +- 34,0; G11: 91,9N +- 24,0; G12: 90,0N +- 13,1 apresentaram menor resistência ao cisalhamento quando comparados aos não envelhecidos. No entanto, quando comparado entre os envelhecidos, assim como nos não envelhecidos, os grupos G9: 59,3N +- 19,9; G10: 59,7N +- 10,9 também apresentaram resistência inferior comparado aos demais grupos. Podemos concluir que o clareamento dental com o peróxido de hidrogênio a 35% promoveu redução da resistência adesiva. Além disso, o tratamento do esmalte clareado com hidrogel de ascorbato de sódio a 20% e a 40% permitiu alcançar valores de resistência de união similar ao esmalte não clareado.
63

Desenvolvimento de equipamento para ensaios Simple Shear

Corte, Marina Bellaver January 2016 (has links)
Em virtude da presença cada vez mais frequente de solicitações cíclicas nas estruturas de engenharia e do aprimoramento da análise de projetos, os ensaios em solos sob carregamentos cíclicos tiveram seu interesse renovado nos últimos anos. Os ensaios de laboratório são realizados de forma que simulem, da melhor maneira possível, as condições observadas em campo. Tais condições auxiliam na escolha dos ensaios a serem conduzidos para a determinação de parâmetros geotécnicos relevantes a cada situação observada em campo. Dentre os ensaios empregados na Engenharia Geotécnica, destaca-se o simple shear. Este ensaio é conhecido e utilizado para medir a resistência ao cisalhamento e a rigidez de solos. Este é o único ensaio de laboratório capaz de submeter uma amostra a condições de deformação plana sob volume constante e permitir a rotação das tensões principais. Tais condições são frequentemente representativas em diversas situações em campo como, por exemplo, o modo de cisalhamento adjacente ao fuste de uma estaca ou sob plataformas offshore com base gravitacional. Nesse contexto, um equipamento foi desenvolvido para a realização de ensaios do tipo simple shear. O aparato conta com uma câmara, na qual é aplicada pressão à amostra de solo. Diferenciando-se do equipamento comercial para tais ensaios, que emprega uma membrana com anéis metálicos, a amostra de solo neste equipamento é envolta por uma membrana de látex, o que possibilita a consolidação de forma isotrópica ou anisotrópica. Quanto ao carregamento, o equipamento desenvolvido permite que o carregamento seja realizado de forma monotônica ou clíclica. Quando do carregamento cíclico, este pode ainda ser realizado de forma a se manter a tensão controlada ou a deformação. Foram conduzidos ensaios de calibração e validação do equipamento empregando-se uma areia fina de granulometria uniforme cujas propriedades são amplamente conhecidas através de outros ensaios. Os resultados obtidos foram então comparados com estudos no mesmo material em equipamentos triaxiais, cisalhamento direto e outro simple shear. Os resultados mostraram-se satisfatórios, validando o equipamento desenvolvido. / In view of the ever more frequent presence of the cyclic solicitations on Engineering structures and the enhancement of design analysis, the soil testing under cyclic loading conditions had its interest renewed in the last years. The laboratory tests are conduced in a way that simulates, in the best way possible, the observed field conditions. Said conditions aid on the choice of the tests to be conducted in order to determinate the relevant geomechanics parameters.to each situation observed on the field. Among the employed tests in Geotechnical Engineering, it is highlighted the simple shear. This test is known and used to measure the shear strength and soil righty. This is the only laboratory test capable of submitting the sample to plane strain conditions under constant volume and allows the main stress rotations. Said conditions are frequently representative in many field situations, such as, the adjacent shear mechanism to the shaft of a pile or, under offshore platforms with gravitational base. In this context, a equipment was developed to perform simple shear tests. The apparatus has a chamber, in which it is applied confining pressure to the soil sample. Contrasting from the commercial equipment for said tests, that uses a membrane with metallic rings, in this equipment the soil sample is involved by a latex membrane, allowing the consolidation being carried out isotropically or anisotropically. The loading on this equipment can be conduced on monotonic or cyclic conditions. The cyclic loading can even be conduced by controlling the deformation or the stress. Calibration and validation testes where conduced on the equipment using a fine sand of uniform granulometry which properties are largely known through other tests. The obtained results where then compared to other tests carried out on the same material in triaxial tests, direct shear and other simple shear, The results obtained were considered satisfactory, validating the developed equipment.
64

Influência de agentes clareadores de uso caseiro e em consultório na resistência de união braquetes ao esmalte em diferentes tempos após clareamento

NUNES, Mauro de Amorim Acatauassú 24 May 2013 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2017-01-26T14:06:43Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_InfluenciaAgentesClareadores.pdf: 2187712 bytes, checksum: 239885fed927517fdaed5f44e3ec90e2 (MD5) / Approved for entry into archive by Cleide Dantas (cleidedantas@ufpa.br) on 2017-01-26T14:07:28Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_InfluenciaAgentesClareadores.pdf: 2187712 bytes, checksum: 239885fed927517fdaed5f44e3ec90e2 (MD5) / Made available in DSpace on 2017-01-26T14:07:28Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_InfluenciaAgentesClareadores.pdf: 2187712 bytes, checksum: 239885fed927517fdaed5f44e3ec90e2 (MD5) Previous issue date: 2013-05-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo teve como objetivo avaliar a influência de agentes clareadores na resistência de união de bráquetes metálicos ortodônticos ao esmalte utilizando-se um agente de cimentação resinoso em diferentes tempos após o tratamento clareador e o modo de fratura. Cento e oitenta dentes incisivos permanentes bovinos foram selecionados e aleatoriamente divididos em três grupos: Grupo 1 (controle): sem clareamento. Grupo 2: clareados com Peróxido de Carbamida a 20%, (Opalescence® PF) durante 21 dias, 10 horas/dia. Grupo 3: clareados com Peróxido de Hidrogênio a 38% (Opalescence® Boost™) em duas aplicações de 15 minutos a cada 7 dias (por 21 dias). A seguir, os grupos (2 e 3) foram novamente separados em sub-grupos (n=15) de acordo com o tempo após clareamento para a realização dos procedimentos de colagem de bráquetes ao esmalte: imediato, 24 horas, 7 dias, 14 dias, 21 dias e 28 dias. Os testes de resistência de união por cisalhamento foram realizados em máquina universal de ensaios (EMIC) com velocidade de 0,5mm/min e os valores registrados em MPa. Em seguida, os dentes foram examinados em uma lupa estereoscópica com ampliação de 40 vezes para registrar o Índice de Remanescente Adesivo (IRA). A ANOVA mostrou que a interação técnica x tempo foi significativa (p=0,0310). Os escores foram analisados por meio do teste de Kruskal Wallis e Dunn para comparações entre os tempos e Mann Whitney para comparações entre as técnicas e comparações dos grupos com o controle. Foi considerado o nível de significância de 5%. Em relação ao Grupo 2, não houve diferença estatisticamente significante entre os tempos. Para o Grupo 3, houve menor resistência de união dos bráquetes ao esmalte no tempo imediato, sendo este tempo também diferente estatisticamente do Grupo controle. O tempo imediato não foi estatisticamente diferente dos tempos 14 e 21 dias. Os tempos entre 1 e 28 dias também não foram estatisticamente diferentes entre si. A maioria das fraturas foram do tipo coesiva na interface bráquete/resina ortodôntica. Para o grupo que utilizou o peróxido de hidrogênio a 38% no tempo imediato, as fraturas adesivas na região esmalte/resina ortodôntica foram predominantes. A utilização de peróxido de carbamida a 20%, não influenciou a resistência de união de bráquetes ortodônticos; por outro lado, o uso de peróxido de hidrogênio a 38% imediatamente antes da colagem reduziu a resistência ao cisalhamento. / The aim of this study was to evaluate the influence of bleaching agents on the shear bond strength of metal orthodontic brackets to enamel using a resin cementing agent; and fracture mode, at different time intervals after bleaching treatment. One-hundred-and-eighty bovine permanent incisors were sectioned and randomly divided into three groups: Group I - (control): without bleaching. Group 2: bleached with 20% Carbamide Peroxide, (Opalescence® PF) for 21 days, 10 hours/day. Group 3: bleached with 38% Hydrogen Peroxide, (Opalescence® Boost™) in two 15-minute applications every 7 days (for 21 days). After this, the groups bleached were again divided into sub-groups (n=15) according to the time interval after bleaching to perform procedures for bracket bonding to enamel: immediate, 24 hours, 7, 14, 21 and 28 days. The shear bond strength tests were performed in a universal test machine (EMIC) at a speed of 0.5mm/min and the values were recorded in MPa. After, the teeth were examined under a stereoscopic loupe at 40X magnification, to record the Adhesive Remnant Index (ARI). ANOVA showed the technique x time interaction was significant (p=0.0310). Scores were analyzed by Kruskal Wallis and Dunn tests for comparisons between times and Mann Whitney; between techniques, and comparisons with control group. The level of significance considered was 5%. As regards the Group 2, there was no statistically significant difference among time intervals. For the Group 3, there was lower bond strength of brackets to enamel in the immediate time, and this time also differed statistically from that of the Control group. Immediate time did not differ statistically from the times at 14 and 21 days. Times between 1 and 28 days also did not differ statistically among them. The fractures, were a larger number of the cohesive type at the bracket/ orthodontic resin interface. For the group in which 38% Hydrogen Peroxide was used, adhesive fractures in the enamel/ orthodontic resin region were predominant in the immediate time. Use of 20% Carbamide Peroxide, had no influence on the bond strength of orthodontic brackets; whereas the use of 38% Hydrogen Peroxide immediately before bracket bonding reduced the shear bond strength. Performing bracket bonding immediately after conclusion of bleaching treatment must be contra-indicated.
65

Influência do teor de bentonita na condutividade hidráulica e na resistência ao cisalhamento de um solo arenoso utilizado como barreira impermeabilizante / Influence of the bentonita content on the hydraulic conductivity and shear strength of sandy-soil used for liners

Lukiantchuki, Juliana Azoia 29 June 2007 (has links)
A utilização de solo natural misturado com bentonita empregado em camadas impermeáveis para retenção de contaminante é bastante comum em aterros sanitários. Neste trabalho, serão apresentados os resultados de ensaios com misturas de solo-bentonita nos teores de 3%, 5% e 7%, utilizando-se um solo arenoso proveniente da região de Pindorama (SP). Os ensaios de condutividade hidráulica para o solo-bentonita foram realizados em permeâmetros de parede flexível. Os resultados obtidos indicam que para os teores de 5% e 7% de bentonita a condutividade hidráulica apresenta-se com valores adequados para a construção de barreiras impermeáveis. A resistência ao cisalhamento do solo compactado puro e das misturas compactadas foi avaliada através de ensaios triaxiais do tipo consolidado não drenado (CU) e ensaios de compressão simples. A coesão efetiva e o ângulo de atrito efetivo do solo aumentou e diminuiu, respectivamente, com a adição de bentonita. Os ensaios de resistência à compressão simples para as misturas com 5% de bentonita atingiram valores aceitáveis para o emprego em camadas impermeabilizantes. / It is becoming very common the use of soil-bentonite mixtures for building sanitary landfill liners with the purpose of retaining pollutants. This work shows the results of hydraulic conductivity and shear strength tests performed with soil-bentonite mixtures with 3%, 5% and 7% bentonite content. The natural soil was gathered in the Pindorama area, which is located in the northeast of Sao Paulo state. The hydraulic conductivity tests were performed in a flexible wall permeameter. Test results show that mixtures with 5% and 7% bentonite content are suitable, in terms of hydraulic conductivity, for construction of sanitary landfill liners. The shear strength parameters of natural soil and mixtures have been assessed performing undrained triaxial compression tests and unconfined compression tests. The effective cohesion and the effective friction angle increased and decreased with the increase of the bentonite content, respectively. The unconfined compression test results have shown that mixtures with 5% bentonite content are suitable, in terms of shear strength, for construction of sanitary landfill liners.
66

Resistência ao cisalhamento de solos com fibras de politereftalato de etileno reciclado / Shear strength of soils with polyethylene terephthalate recycled fibers

Castilho, Tayane Westermann Lopes 18 December 2017 (has links)
Submitted by TAYANE WESTERMANN LOPES CASTILHO null (tayanewest@uol.com.br) on 2018-01-26T16:12:01Z No. of bitstreams: 1 Dissertação Tayane Westermann Lopes Castilho.pdf: 4997047 bytes, checksum: c0457ac97bc5e87fd929dbe70703dd0d (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-01-26T18:07:08Z (GMT) No. of bitstreams: 1 castilho_twl_me_bauru.pdf: 4997047 bytes, checksum: c0457ac97bc5e87fd929dbe70703dd0d (MD5) / Made available in DSpace on 2018-01-26T18:07:08Z (GMT). No. of bitstreams: 1 castilho_twl_me_bauru.pdf: 4997047 bytes, checksum: c0457ac97bc5e87fd929dbe70703dd0d (MD5) Previous issue date: 2017-12-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho avaliou a influência da inclusão de fibras recicladas extraídas de garrafas constituídas de politereftalato de etileno (PET) na resistência ao cisalhamento de solos arenoso e argiloso. Por meio de ensaios de compressão simples das amostras dos solos e misturas desses com diferentes teores e comprimentos de fibras, obteve-se que a combinação de 1,5% de fibras, em relação à massa de solo seco, com comprimento de 20 mm levou a um aumento de 92,8% na resistência não confinada para a amostra de solo arenoso, e de 10,5% para a de solo argiloso. Ensaios de cisalhamento direto foram realizados com essa dosagem, em duas diferentes condições de compactação, e revelam o ganho de 66,4% no intercepto de coesão para o solo arenoso com grau de compactação de 100%, e de 55,5% com grau de compactação de 95%, em relação ao solo sem fibra. Enquanto os ângulos de atrito interno praticamente não se alteraram. A mesma dosagem para o solo argiloso promoveu reduções de coesão de 7,6% e 5,4%, respectivamente, para os graus de compactação de 100% e de 95% e aumentos relativos de 2,9% e 7,3% no ângulo de atrito interno. Esses resultados aplicados em dois casos hipotéticos, capacidade de carga de fundações em sapatas e estabilidade de taludes de aterros, demonstram o efeito da inclusão de fibras na melhoria da estimativa da capacidade de carga para ambos os solos e o aumento do fator de segurança para o solo arenoso. O trabalho oferece uma alternativa tecnicamente viável para a melhoria dos solos e que prioriza o reuso de garrafas PET, colaborando para preservação ambiental, mas não só, pois a atividade promove ainda benefícios sociais e econômicos. / This study presents an analysis of the influence of the inclusion of polyethylene terephthalate (PET) fibers, extracted from waste plastic bottles, in the shear strength of sandy and clayey soils. Simple compression tests were performed with soil samples and mixtures of these with different fiber contents and lengths. The combination of 1,5% of fibers in relation to the dry soil mass with a length of 20 mm led to a 92.8% increase in the unconfined resistance for the sandy soil sample and 10.5% for the clayey soil sample. Direct shear tests were carried out with this dosage, with two different compaction conditions, showing the gain of 66.4% in the cohesion intercept for sandy soil with 100% compaction degree, and 55.5% with the degree of 95%, in relation to the soil without fiber. While the angles of internal friction remained almost constant. The same dosage for clayey soil promoted cohesion reductions of 7.6% and 5.4%, respectively, for compaction degrees of 100% and 95% and relative increases of 2.9% and 7.3% in the angle of internal friction. These results, applied in two hypothetical cases, load capacity of an isolated footing foundation and slope stability of landfills, demonstrate the effect of the inclusion of fibers in improving the estimation of the load capacity for both soils and the increase of the safety factor for the sandy soil. The study offers a technically feasible alternative for the improvement of soils, and that prioritizes the reuse of PET bottles, collaborating for environmental preservation, but not only, since the activity also promotes social and economic benefits.
67

Avaliação de tratamentos de superfície na união de cimento resinoso ao titânio comercialmente puro

Almeida Junior, Antonio Alves de [UNESP] 26 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-26Bitstream added on 2014-06-13T20:18:31Z : No. of bitstreams: 1 almeidajunior_aa_me_arafo.pdf: 459545 bytes, checksum: df0008777c6ad28ca07cacdc0ed332ac (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo avaliou a resistência ao cisalhamento da união entre o titânio comercialmente puro fundido e o cimento resinoso não-adesivo (RelyX ARC – 3M ESPE) após diferentes tratamentos na superfície metálica. Noventa discos de titânio comercialmente puro foram divididos aleatoriamente em nove grupos, os quais receberam um dos seguintes tratamentos, antes da aplicação do RelyX ARC: (n=10): 01) Al2O3 (50 μm); 02) Al2O3 (50 μm) + adesivo; 03) Al2O3 (50 μm) + silano; 04) Cojet Sand (30 μm); 05) Cojet Sand + adesivo; 06) Cojet Sand + silano; 07) Al2O3 (50 μm) + Rocatec (110 μm); 08) Al2O3 (50 μm) + Rocatec + adesivo; 09) Al2O3 (50 μm) + Rocatec + silano. Os espécimes foram termociclados (5.000 ciclos - 5 – 55 oC - 30 segundos de imersão) e então submetidos ao ensaio de cisalhamento As médias de resistência ao cisalhamento da união dos grupos de 1 a 9 foram respectivamente: 4,10 ± 0,79CD; 6,14 ± 0,99B; 4,34 ± 0,71CD; 2,58 ± 0,37EF; 2,31 ± 0,23 F; 5,70 ± 0,93B; 3,65 ± 0,70DE; 5,25 ± 1,08BC e 8,36 ± 1,63A. O teste t de Student apontou igualdade estatística entre os grupos jateados com partículas de Al2O3 e com partículas revestidas por sílica (P=0,630). A análise de 22 variância (ANOVA) a dois critérios seguida pelo teste de Tukey indicaram que: 1) o Rocatec apresentou resistência significativamente maior que o Cojet Sand (P<0,05); 2) o jateamento com partículas de óxido de alumínio apresentou resistência significativamente maior quando associado ao adesivo (P<0,001) enquanto o silano foi o melhor tratamento pós jateamento para as partículas revestidas por sílica (P<0,001) e 3) O jateamento com Rocatec seguido da aplicação do silano proporcionou a maior resistência ao cisalhamento de união entre o titânio comercialmente puro e o RelyX ARC. Todos os grupos apresentaram falha 100% adesiva. / This study evaluated the shear bond strength of a conventional resin cement (RelyX ARC – 3M ESPE) to cast commercially pure titanium (cp Ti) after different treatments on metal surface. Ninety cp Ti disks were randomly divided into 9 groups which received one of the following treatments before the application of RelyX ARC: (n=10): 01) Al2O3 (50 μm); 02) Al2O3 (50 μm) + adhesive; 03) Al2O3 (50 μm) + silane; 04) Cojet Sand (30 μm); 05) Cojet Sand + adhesive; 06) Cojet Sand + silane; 07) Al2O3 (50 μm) + Rocatec (110 μm); 08) Al2O3 (50 μm) + Rocatec + adhesive; 09) Al2O3 (50 μm) + Rocatec + silane. All specimens were thermal cycled (5000 cycles, 5 - 55 oC – 30-second dwell time) before tested in shear mode. The mean bond strength values (Mpa) for all groups were, respectively: 4,10 ± 0,79CD; 6,14 ± 0,99B; 4,34 ± 0,71CD; 2,58 ± 0,37EF; 2,31 ± 0,23 F; 5,70 ± 0,93B; 3,65 ± 0,70DE; 5,25 ± 1,08BC e 8,36 ± 1,63A. The Student t test showed that there was no significant difference between Al2O3 particles and silica-modified Al2O3 particles (P=0.630). Two-way ANOVA and post hoc Tukey test (=.05) showed that: 1) Rocatec demonstrated significantly higher shear bond strength than Cojet Sand (P<0.05); 2) airborne-particle abrasion with Al2O3 particles exhibited the highest shear bond strength with adhesive (P<0.001) while silica-modified Al2O3 particles exhibited the best behavior when associated with silane (P<0.001); 3) Rocatec plus silane provided the highest shear bond strength between cp Ti and RelyX ARC. All groups showed 100% adhesive failure.
68

Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinoso

Ribeiro, João Gustavo Rabelo [UNESP] 03 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-03Bitstream added on 2014-06-13T19:16:51Z : No. of bitstreams: 1 ribeiro_jgr_me_arafo.pdf: 3291389 bytes, checksum: 7433b8057e44c506b548538c7a3e997e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de a e b. As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos... / The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) a and b treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values.
69

Efeito de tratamento de superfície do titânio comercialmente puro na resistência de união com cimentos ionomérico e resinosos

Abi Rached, Filipe de Oliveira [UNESP] 31 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-31Bitstream added on 2014-06-13T20:18:32Z : No. of bitstreams: 1 abirached_fo_me_arafo.pdf: 762282 bytes, checksum: bf4b7b544331c76ec042fed619402110 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O titânio, em virtude de suas atrativas propriedades, foi introduzido na área de reabilitação oral podendo ser indicado para a confecção de restaurações metalocerâmicas dento- ou implanto-suportadas. No entanto, apresenta dificuldade de união com materiais resinosos, o que poderia comprometer a longevidade dessas restaurações, considerando a importância da qualidade de união na interface metal/cimento. Para contornar este problema, pode-se lançar mão de tratamentos de superfície do titânio, empregados isoladamente ou em associação. Este estudo avaliou a eficácia de diferentes tratamentos de superfície na resistência ao cisalhamento (RC) da união do cimento ionomérico modificado por resina RelyX Luting 2 e dos cimentos resinosos RelyX ARC e RelyX U100 ao titânio comercialmente puro (Ti cp). Duzentos e quarenta discos (9 x 3 mm) foram fundidos em Ti cp, incluídos em tubos de PVC e regularizados com lixas de carbeto de silício (150, 400 e 600) em politriz. Os espécimes foram divididos aleatoriamente em oito grupos (n=30), os quais receberam um dos seguintes tratamentos de superfície: (1) Al2O3 50 μm; (2) Al2O3 120 μm; (3) Al2O3 250 μm; (4) Al2O3 50 μm + silano; (5) Al2O3 120 μm + silano; (6) Al2O3 250 μm + silano; (7) Cojet Sand (30 μm) + silano; (8) Al2O3 120 μm + Rocatec (110 μm) + silano. Os cimentos (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 foram aplicados às superfícies tratadas do Ti cp (n=10). Os espécimes foram termociclados (5.000 ciclos, 5 e 55 °C, 30 segundos de imersão) e, então, submetidos ao ensaio de cisalhamento (0,5 mm/min). O modo de fratura foi avaliado em estereomicroscópio (x20). Os dados foram analisados por ANOVA 2 fatores e teste de Tukey (α=0,05). Os cimentos RelyX Luting 2 e RelyX U100 apresentaram comportamento semelhante com relação ao tratamento de superfície... / Titanium was introduced in the field of oral rehabilitation because of its attractive properties, as it can be indicated for fabricating tooth- or implant-supported metal ceramic restorations. However, difficulties have been shown to exist as regards the bond between resin-based materials and titanium, which could compromise the longevity of these restorations, considering the importance of the bond quality at the metal/cement interface. To overcome this problem, titanium surface treatments can be applied alone or they can be combined with each other. This study evaluated the efficacy of different surface treatments on the shear bond strength (SBS) of RelyX Luting 2 resin-modified glass ionomer cement, RelyX ARC and RelyX U100 resin cements to commercially pure titanium (CP Ti). Two hundred and forty discs (9 x 3 mm) were cast from CP Ti, embedded in PVC tubes and smoothed with silicon carbide papers (150, 400 and 600) using a polisher. Specimens were randomly divided into 8 groups (n=30), which received one of the following surface treatments: (1) 50 μm Al2O3; (2) 120 μm Al2O3; (3) 250 μm Al2O3; (4) 50 μm Al2O3 + silane; (5) 120 μm Al2O3 + silane; (6) 250 μm Al2O3 + silane; (7) Cojet Sand (30 μm) + silane; (8) 120 μm Al2O3 + Rocatec (110 μm) + silane. The luting cements (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 were applied to the treated CP Ti surfaces (n=10). Specimens were thermal cycled (5,000 cycles, 5 and 55 °C, 30-second dwell time), and afterwards submitted to SBS testing (0.5 mm/min). Failure mode was evaluated under a stereomicroscope (x20). Data were analyzed using 2-way ANOVA and Tukey’s test (α=0.05). The RelyX Luting 2 and RelyX U100 luting cements exhibited similar behavior regards to the surface treatment. For both, only the group abraded with 50 μm Al2O3 particles promoted lower SBS than the other groups (P>.05)... (Complete abstract click electronic access below)
70

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese

Azevedo, Andréa [UNESP] 24 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-24Bitstream added on 2014-06-13T18:58:04Z : No. of bitstreams: 1 azevedo_a_me_arafo.pdf: 1794729 bytes, checksum: de3688df34dcd910d44637e0076e7e4c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)... / This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below)

Page generated in 0.139 seconds