• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mätning av fuktkvot i sammansatta KL-träelement / Moisture content measurements in assembled CLT-elements

Andersson, Josefine, Svensson, Simon January 2018 (has links)
Fuktskador är ett problem som kan uppstå vid byggnation i trä om konstruktionen exponeras för nederbörd under byggtiden. Mätning av fuktkvoter i trä kan utföras med flera olika instrument och metoder. Syftet med arbetet är att studera fuktkvotsförändringar i korslimmade träelement som utsätts för långvarig nederbörd i laborationsmiljö. För att utveckla detta område har Linnéuniversitetet tillsammans med Saab utvecklat ett eget mätinstrument. Instrumentet mäter resistans i trä som jämförs med mätvärden från ett annat instrument vid namn Gigamodule. Det egenutvecklade sensorkortet är fortfarande under utveckling. Förutom i arbetets försöksuppställning testas instrumentet även i en byggnad i Växjö. För kontroll av mätresultat har fler metoder och instrument använts. Två modeller har använts som representerar detalj vid anslutning av väggelement-och mellanbjälklag. Båda modellerna har under lika lång tid varit nedsänkta i vattenbad. Försöksuppställningen har utförts mellan 19:e april och 18:e maj 2018. Mätningar och beräkningar har resulterat i jämförbara resultat. Skillnader i resultat utifrån träets fiberriktning har visats från flera instrument. KL-träelementen har uppvisat en god förmåga att trots höga fuktkvotsvärden torka ut och återgå mot normala värden under mätperioden. / Moisture related damage is an occurring problem in wood-based buildings if the material is exposed to rainfall during construction. Measurement of moisture content can be done with various instruments and methods. The purpose of the thesis is to study change in moisture content in cross-laminated-timber, with prolonged exposure to water in laboratory environment. To advance the field, the Linnaeus University has been developing a measurement instrument of their own in collaboration with the company Saab. The instrument measures electrical resistance in wood where the obtained values will be compared to similar measurements from a product named Gigamodule. The self-developed sensor card is still a product under development. In addition to the lab setting measurements the instrument was also installed in a local building in Växjö. To verify the result from the previously mentioned resistance measurers additional instruments and methods have been utilized. Two separate models have been used to represent the detail of the connection between the wall element and the joist. Both models have been submerged under water for an equal amount of time. The experimental setting took place between the 19th of April to the 18th of May 2018. The measurements and calculations have been resulting in values that can be the subject of internal evaluation. Difference in result based on the direction of the grain have been observed in several measurement methods. The CLT-elements demonstrated good drying properties despite periodically high moisture content and the wood indicate a return towards initial levels of moisture.

Page generated in 0.1116 seconds