Avalia??o da influ?ncia da resistividade el?trica do solo e de tipos de envelopamento no sistema de aterramento el?trico de subesta??es / Evaluation of the influence of the electrical resistivity of the soil and of the types of enveloping in the electrical grounding system of substationsPimenta, Camila Madeiros Alcantara 15 December 2017 (has links)
Submitted by SBI Biblioteca Digital (sbi.bibliotecadigital@puc-campinas.edu.br) on 2018-02-19T16:48:56Z
No. of bitstreams: 1
CAMILA MADEIROS ALCANTARA PIMENTA.pdf: 4765494 bytes, checksum: dac59f354329911b1dfcb8422a61af1b (MD5) / Made available in DSpace on 2018-02-19T16:48:56Z (GMT). No. of bitstreams: 1
CAMILA MADEIROS ALCANTARA PIMENTA.pdf: 4765494 bytes, checksum: dac59f354329911b1dfcb8422a61af1b (MD5)
Previous issue date: 2017-12-15 / Electrical grounding is part of the Atmospheric Discharge Protection System (ADPS), whose functions are to provide a path for the circulation of electric current in the ground and to enable the detection of a possible fault between the energized conductors and the earth. For grounding to be efficient, some characteristics must be taken into account, such as soil type and resistivity. In this sense, measurements of resistivity and soil stratification are important for a correct sizing of the grounding system. Soils with high water concentration (low resistivity) are better current conductors than dry soils, for example. Soils with high resistivity can cause a return current. Thus, some decisions aimed at strengthening the grounding system should be taken when there are soils with inadequate grounding characteristics. Therefore, this work aims to evaluate the influence of soil electrical resistivity and enveloping types using concrete types in the substation electrical grounding system through software simulations, taking into account soil resistivity characteristics. In the analysis of types of envelopment, it was possible to observe that the concretes with greater amount of water in their composition have a lower electrical resistivity. The use of concrete enveloping is feasible for soils with high resistivity, as in the case of the land located in the city of Campinas, and it was possible to verify that for soils with low resistivity its use may be impractical since other options such as inclusion of more cables and installation of the rods in the layers with less resistivity are sufficient and more economical. / O aterramento el?trico faz parte do Sistema de Prote??o Contra Descargas Atmosf?ricas (SPDA), cujas fun??es s?o fornecer um caminho para a circula??o de corrente el?trica na terra, escoamento para a terra de cargas induzidas nas carca?as dos equipamentos el?tricos e, em conjunto com os dispositivos diferenciais-residuais, possibilitar a detec??o de uma poss?vel falha entre os condutores energizados e a terra. Para que o aterramento seja eficiente, algumas caracter?sticas devem ser levadas em considera??o, tais como o tipo e a resistividade do solo. Neste sentido, medi??es da resistividade e a estratifica??o do solo s?o importantes para um dimensionamento correto do sistema de aterramento. Solos com alta concentra??o de ?gua (baixa resistividade) s?o melhores condutores de corrente do que um solo seco, por exemplo. Solos com alta resistividade podem ocasionar uma corrente de retorno. Assim, algumas decis?es visando o refor?o do sistema de aterramento devem ser tomadas quando se tem solos com caracter?sticas inadequadas ao aterramento. Portanto, esse trabalho teve como objetivo avaliar a influ?ncia da resistividade el?trica do solo e de tipos de envelopamento utilizando tipos de concreto no sistema de aterramento el?trico de subesta??es atrav?s de simula??es em software, levando em conta as caracter?sticas de resistividade do solo. Nas an?lises de tipos de envelopamento, foi poss?vel observar que os concretos com maior quantidade de ?gua em sua composi??o possuem uma resistividade el?trica mais baixa. A utiliza??o do envelopamento de concreto ? vi?vel para solos com alta resistividade, como ? o caso do terreno localizado na cidade de Campinas, e foi poss?vel verificar que para solos com resistividade baixa sua utiliza??o pode ser invi?vel j? que outras op??es como inclus?o de mais cabos e instala??o das hastes nas camadas com menor resistividade s?o suficientes e mais econ?micas.
|
112 |
Anisotropia de resistividade elétrica em filmes finos nanoestruturados. / Electrical resistivity anisotropy in nanostructured thin films.Fernanda de Sá Teixeira 18 May 2007 (has links)
O objetivo principal deste trabalho foi desenvolver um dispositivo de filme fino com anisotropia de resistividade elétrica. A idéia foi usar um efeito quântico presente em filmes muito finos de materiais condutores ou semicondutores com morfologia anisotrópica na superfície. A morfologia foi um perfil unidirecional quase-senoidal. As resistividades foram determinadas medindo-se as resistências elétricas destes materiais em direções ortogonais, levando-se em conta a geometria da amostra e suas dimensões. O material condutor usado foi Polimetilmetacrilato (PMMA) com ouro implantado na superfície. A profundidade média de implantação foi 2,7 nm. Na fabricação do dispositivo foi utilizada micro e nanolitografia, caracterização por Microscopia Eletrônica de Varredura e Microscopia de Força Atômica e implantação de ouro por MePIIID (Metal Plasma Immersion Ion Implantation and Deposition). / The main purpose of this work was to develop a thin film device with electrical anisotropic resistivity. The idea was to use a quantum effect which is present in very thin films of conductor or semiconductor materials with anisotropic morphology on the surface. The morphology was a sinusoidal-like unidirectional profile. The resistivities were determined measuring the electrical resistances of theses materials in orthogonal directions, taking in account the sample geometry and dimensions. The conductive material used was Polymethylmethacrylate (PMMA) with gold implanted on the surface. The average implanted depth was 2.7 nm. In the device fabrication were used micro and nanolithography, characterization by Scanning Electron Microscopy and Atomic Force Microscopy and gold implantation by MePIIID (Metal Plasma Immersion Ion Implantation and Deposition).
|
113 |
Uma proposta de representação de sistemas de aterramento diretamente no domínio do tempo / A proposal of representation of grounding systems directly in the time domainSeixas, Claudiner Mendes de [UNESP] 25 August 2017 (has links)
Submitted by CLAUDINER MENDES DE SEIXAS null (claudiner2010@gmail.com) on 2017-10-21T02:06:24Z
No. of bitstreams: 1
Tese_Claudiner_seixas_ac_dr_ilha.pdf: 3441885 bytes, checksum: 9e1f3e2ff82a0a8220457c535d4cea55 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-26T14:27:13Z (GMT) No. of bitstreams: 1
seixas_cm_dr_ilha.pdf: 3441885 bytes, checksum: 9e1f3e2ff82a0a8220457c535d4cea55 (MD5) / Made available in DSpace on 2017-10-26T14:27:13Z (GMT). No. of bitstreams: 1
seixas_cm_dr_ilha.pdf: 3441885 bytes, checksum: 9e1f3e2ff82a0a8220457c535d4cea55 (MD5)
Previous issue date: 2017-08-25 / Este trabalho apresenta uma proposta de representação de sistemas de aterramento elétrico diretamente no domínio do tempo, tendo como vantagem os benefícios da modelagem realizada no domínio da frequência, com os resultados fornecidos diretamente no domínio do tempo, sem passar por transformadas inversas (Laplace ou Fourier). Os modelos no domínio do tempo são facilmente inseridos nos softwares convencionais de análise transitória, onde as tensões e correntes são melhor compreendidas. A maior contribuição deste trabalho está no desenvolvimento de uma técnica capaz de representar o aterramento com elementos discretos e positivos de circuitos (resistores-R, capacitores-C e indutores-L). Assim, o circuito equivalente representativo do aterramento será sempre um circuito possível de ser implementado fisicamente. Nesta proposta o aterramento é inicialmente modelado no domínio da frequência, sua impedância harmônica é obtida e representada por meio de elementos discretos de circuitos (RLC) associados em série e/ou paralelo. Aterramentos constituídos por um eletrodo horizontal ou uma haste vertical foram representados por meio de aproximação usando o método dos mínimos quadrados (vector fitting), que permite obter a função racional equivalente à admitância do aterramento, a partir da qual são extraídos os ramos de circuitos e consequentemente o circuito equivalente. Apesar de ser possível representar uma infinidade de aterramentos, dependendo do comprimento e diâmetro do eletrodo/haste combinado com determinadas resistividade e permissividade elétricas do solo, esse método pode não garantir que todos os elementos RLC sejam positivos. Por isso foi desenvolvido uma nova técnica e testada em aplicações com configurações de aterramento mais complexas (malhas). Essa técnica fornece resultados precisos e garante que todos os elementos RLC serão positivos. Sua validação foi realizada comparando os resultados propostos com os resultados obtidos pelo modelo de linha de transmissão (no caso de eletrodo/haste) e pelo modelo eletromagnético híbrido HEM (no caso das malhas). Essa técnica permite o uso de qualquer modelo capaz de fornecer a impedância harmônica, podendo ser aplicada a configurações genéricas de aterramento, o que a torna muito versátil e atrativa. / This work presents a proposal to represent of electrical grounding systems directly in time domain, taking into account the benefits in frequency domain modelling, without employing inverse Laplace or Fourier transforms. The time domain models are easily inserted in conventional electromagnetic transient software, where voltages and currents are better understood. The main contribution of this work is the development of a technique that can represent grounding by discrete and positive circuits elements (R-resistors, C-capacitors and L-inductors). The representation of the grounding is an electric circuit, possible to be implemented physically. Grounding systems is initially modelled in the frequency domain, where its harmonic impedance is obtained and then represented by elements of circuit (RLC) made in series and/or parallel association. Grounding systems constituted by a horizontal electrode or a vertical rod were represented by means of an approximation using the method of the least squares (vector fitting). It reproduces the rational function equivalent to the admittance of the grounding, which branches of circuits are extracted, forming an equivalent circuit. Although it is possible to represent an infinity of groundings, depending on the length and diameter of the electrode / rod combined with certain electrical resistivity and permittivity of the soil, this technique may not guarantee that all RLC elements are positive. However, a new technique was developed and tested in more complex grounding systems (grids). This technique provides accurate results and ensures that all RLC elements will be positive. Its validation was performed comparing the proposed results with the results obtained by the TLM (Transmission Line Model) employed for the horizontal electrodes and vertical rods and by the HEM (Hybrid Electromagnetic Model) employed for grounding grids. This technique allows the use of any model capable of providing harmonic impedance, and can be applied to generic ground configurations, making it very attractive to electromagnetics transient analyses.
|
114 |
Um estudo das condi??es de percola??o e estabilidade em barragens de terra mediante m?todos geof?sicos: caso do dique de Sant Lloren? de Montgai - EspanhaTeixeira, Washington Luiz Evangelista 17 June 2013 (has links)
Made available in DSpace on 2015-02-24T19:48:45Z (GMT). No. of bitstreams: 1
WashingtonLET_TESE.pdf: 9876489 bytes, checksum: b0b53c16cdf88ab9e63cb1b22c08ab0f (MD5)
Previous issue date: 2013-06-17 / The monitoring of Earth dam makes use of visual inspection and instrumentation to identify and characterize the deterioration that compromises the security of earth dams and associated structures. The visual inspection is subjective and can lead to misinterpretation or omission of important information and, some problems are detected too late. The instrumentation are efficient but certain technical or operational issues can cause restrictions. Thereby, visual inspections and instrumentation can lead to a lack of information. Geophysics offers consolidated, low-cost methods that are non-invasive, non-destructive and low cost. They have a strong potential and can be used assisting instrumentation. In the case that a visual inspection and strumentation does not provide all the necessary information, geophysical methods would provide more complete and relevant information. In order to test these theories, geophysical acquisitions were performed using Georadar (GPR), Electric resistivity, Seismic refraction, and Refraction Microtremor (ReMi) on the dike of the dam in Sant Lloren? de Montgai, located in the province of Lleida, 145 km from Barcelona, Catalonia. The results confirmed that the geophysical methods used each responded satisfactorily to the conditions of the earth dike, the anomalies present and the geological features found, such as alluvium and carbonate and evaporite rocks. It has also been confirmed that these methods, when used in an integrated manner, are able to reduce the ambiguities in individual interpretations. They facilitate improved imaging of the interior dikes and of major geological features, thus inspecting the massif and its foundation. Consequently, the results obtained in this study demonstrated that these geophysical methods are sufficiently effective for inspecting earth dams and they are an important tool in the instrumentation and visual inspection of the security of the dams / O monitoramento do comportamento de barragens de terra faz uso da inspe??o visual e da instrumenta??o para identificar e caracterizar danos no barramento ou estruturas auxiliares. A primeira ? subjetiva possibilitando erros de interpreta??o ou omiss?o, mesmo assim, alguns problemas s? podem ser detectados tardiamente. A instrumenta??o tem se mostrado satisfat?ria, mas pode apresentar restri??es por quest?es t?cnicas ou operacionais. Assim, pode existir defici?ncia nas informa??es produzidas pela inspe??o visual e pela instrumenta??o. A Geof?sica disp?e de m?todos consolidados, n?o invasivos, n?o destrutivos, e de baixo custo, com forte potencial para atuar auxiliando a instrumenta??o convencional, podendo, no caso de inexist?ncia ou falha geral desta, fornecer informa??es mais completas e relevantes que a inspe??o visual. Para fundamentar essas afirma??es, foram realizadas aquisi??es geof?sicas de Resistividade El?trica, Georadar (GPR), S?smica de refra??o, e Refraction Microtremor (ReMi) no dique da barragem de Sant Lloren? de Montgai, localizada na prov?ncia de Lleida, a 145 Km de Barcelona Catalunha. Os resultados obtidos confirmaram que os m?todos geof?sicos utilizados respondem individualmente de forma satisfat?ria ?s condi??es construtivas do dique de terra, ?s anomalias presentes, e ? geologia encontrada (aluvi?o, rochas carbon?ticas e evapor?ticas). Pode se afirmar ainda que esses m?todos, quando utilizados de forma integrada, s?o capazes de diminuir as ambiguidades nas interpreta??es individuais e permitem o imageamento satisfat?rio do interior do dique e das principais fei??es geol?gicas e dessa forma inspecionar o maci?o e sua funda??o. Dessa forma, os resultados apresentados por essa pesquisa demonstram que os m?todos geof?sicos constituem uma importante ferramenta que pode ser utilizada na verifica??o das condi??es do maci?o de uma barragem de terra
|
115 |
MODELAGEM DE REDES AÉREAS COM RETORNO POR TERRA EM SISTEMAS DE DISTRIBUIÇÃO DE ENERGIA ELÉTRICA PARA ANÁLISES DE FALTAS DE ALTA IMPEDÂNCIA / MODELING OF AERIAL NETS WITH RETURN FOR LAND IN SYSTEMS OF DISTRIBUTION OF ELECTRIC ENERGY STOPS ANALYSES OF LACKS OF HIGH IMPEDANCESouza, Júlio César Nascimento 22 September 2006 (has links)
Made available in DSpace on 2016-08-17T14:53:02Z (GMT). No. of bitstreams: 1
Julio Cesar Nascimento Sousa.pdf: 971697 bytes, checksum: b4ee5e79977202a1c5eba4528ed34766 (MD5)
Previous issue date: 2006-09-22 / This work focuses on the modeling of single-phase and three-phase distribution with
earth return, for high impedance faults analysis. The main motivation is the lack of definitive
solutions for such faults. These faults often occur when an overhead conductor breaks and
falls on high impedance surface such as asphalt road, cement, trees, among others. That fault
is analyzed in a Single wire earth return system - SWER, and in a rural three-phase feeder.
The SWER is deduced starting from a generic three-phase system, where
simplifications based on practical assumptions are added. Simulations are accomplished in
two distribution test systems, with the objective of identifying the behavior pattern of the high
impedance faults. It is also included a discussion and analysis of results and suggestions
related to future works. / Este trabalho focaliza a modelagem das redes de distribuição monofásicas e trifásicas
com retorno por terra, para análise das faltas de alta impedância. A motivação principal está
no fato de não existirem soluções definitivas para essas faltas. Este tipo de falta ocorre quando
um cabo energizado rompe e cai sobre um tipo de superfície, tal como asfalto, areia, árvores,
dentre outros. Essa falta é analisada em uma rede Monofásica com Retorno por Terra MRT
em uma rede trifásica rural.
A rede MRT é deduzida a partir de uma rede trifásica genérica, onde são adicionadas
hipóteses simplificadoras práticas. São realizadas simulações em dois sistemas testes de
distribuição, com o objetivo de identificar o padrão de comportamento das faltas de alta
impedância. É realizada uma discussão e análise de resultados, sugerindo-se trabalhos futuros.
|