• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Single crystal silicon Lorentz force actuated micromirror and MEMS blazed grating for optics and sensors

Li, Meiting 18 January 2016 (has links)
Micromirrors and diffraction gratings were developed for spectroscopy and magnetic field sensor in this thesis. MEMS blazed gratings were successfully fabricated in different grating periodicities to cover a wide infrared wavelength range. Lorentz force actuated micromirrors were investigated, and two types of mirrors were fabricated: rotating and pop-up micromirrors. The deflection angle of the mirrors was controllable by altering the driving current on the mirror. Deflection angle vs. driving current was studied for different mirror types and different spring dimensions. A Lorentz force based magnetic field sensor is also demonstrated. The sensor employs the rotating micromirror as a resonator. With an AC current flowing around the micromirror, a periodic Lorentz force is generated which drives the resonator. The rotational amplitude of the micromirror is measured with an optical positioning system and external circuits. The highest resolution of the magnetic field sensor is 0.4 nT at 50 mArms, and 53 mHz filter bandwidth. With appropriate current level, this sensor can measure a wide range of magnetic field, from nT to T. / October 2016
2

Direct Measurement of the Spectral Distribution of Thermal Noise

Slagmolen, Bram Johannes Jozef, BRAM.SLAGMOLEN@ANU.EDU.AU January 2005 (has links)
This thesis investigates the direct measurement of the thermal noise spectral distribution. Long base line gravitational wave detectors, being commissioned around the world, are limited in sensitivity in the intermediate frequencies by the thermal noise. These detectors are utilising suspended test mirrors for the detection of gravitational waves by measuring their relative displacement. One of the fundamental noise sources in these detectors is the thermally induced displacement of the suspension onto and within the mirrors. This thermally induced motion of the test mirrors limits the displacement sensitivity of the gravitational wave detectors. Knowledge of the spectral behavior of thermal noise over a wide frequency range will improve predictions and understanding of the behavior of the suspension and test mirrors.¶ In this thesis the direct measurement of the thermal noise spectral distribution of a mechanical flexure resonator is described. The mechanical flexure resonator is an unidirectional ’wobbly table’ made from copper-beryllium, which hinges around four thin flexures 15 mm wide, 1 mm high and ~116 µm thick. The mechanical flexure resonator has a resonant frequency of 192 Hz, with a quality factor of ~3000.¶ The thermal noise induced displacement of the mechanical flexure resonator was measured using an optical cavity. The end mirror of a two mirror optical cavity was mounted on the mechanical flexure resonator. A laser was made resonant with the test cavity by use of a locking control system. Thermal noise induced displacement moved the test cavity away from resonance. By measuring the error-signal in the control system, the equivalent thermal noise displacement was obtained.¶ The thermal noise induced displacement of the mechanical flexure resonator was predicted to be in the order of 10^(−12) to 10^(−17) m/sqrtHz over a frequency range of 10 Hz to 10 kHz. All other external noise sources needed to be suppressed to below this level. A major noise source was the laser frequency fluctuations. When the test cavity was locked to the laser, the laser frequency fluctuations dominated the read out signal. To suppress the frequency fluctuations, the laser was locked to a rigid long optical reference cavity. This allowed the frequency fluctuations to be suppressed to below the equivalent thermal noise displacement of the test cavity over the frequency range of interest.¶ Acoustic noise was suppressed by placing the whole experiment inside a vacuum chamber, and evacuating the air inside the chamber down to a pressure level of 10^(−4) mbar. A seismic vibration isolation system was used to suppress the seismic noise in the laboratory to below 10^(−14) m/sqrtHz at frequencies above 4 Hz.¶ With the experimental set up, the thermal noise displacement of the mechanical flexure resonator has been measured. Due to the degradation of the isolator performance, measurement of the thermal noise behavior over a wide frequency range of the mechanical flexure resonator was unsuccessful. By using an analytical curve fitting routine around the fundamental and first order resonant modes of the resonator, a loss factor of (3.5 ± 1.5 − 3.7 ± 1.5) × 10^(−4) for the copper-beryllium mechanical flexure resonator was obtained and structural damping was inferred.

Page generated in 0.046 seconds