• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 14
  • 14
  • 14
  • 10
  • 10
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Concreto com agregados graúdos reciclados de concreto : influência da idade de reciclagem nas propriedades dos agregados e concretos reciclados. / Concrete with recycled concrete coarse aggregates : influence of age of recycling in the properties of recycled aggregates and concretes

Buttler, Alexandre Marques 12 May 2003 (has links)
Os resíduos de concreto apresentam grande potencial para serem reciclados quando comparados com outros resíduos, entretanto, o número de estudos realizados no Brasil é muito pequeno dificultando a utilização deste material em dosagens estruturais. Em virtude disso, desenvolveu-se um estudo teórico-experimental visando caracterizar algumas propriedades do agregado e do concreto reciclado; no estudo teórico exploraram-se aspectos relacionados à geração, deposição, processos para recuperação, britagem, casos práticos, pesquisas envolvendo reciclados de concreto e as recomendações normativas existentes. No desenvolvimento experimental, analisou-se a influência do período decorrido entre a moldagem e a reciclagem do concreto nas propriedades dos agregados e concretos. Os resultados indicam que resíduos reciclados logo após sua geração, contribuem positivamente para as propriedades mecânicas do concreto, devido à existência de grande quantidade de partículas não-hidratadas de cimento, tais concretos obtiveram resultados superiores para a resistência à compressão e tração quando comparados aos concretos com agregados naturais. / The concrete residues show a large potential to be recycled when compared with other residues; however, the number of studies in Brazil is very small hindering the use of this material in structural dosage. By virtue of that, it was developed a theoretical-experimental study to characterize some properties of aggregate and recycled concrete; in the theoretical study it was explored aspects related to the generation, deposition, processes for recovery, crushing, practical cases, researches involving recycled of concrete and the existent normative recommendations. In the experimental development, it was analyzed the influence of the period elapsed between the molding and the recycling of the concrete in the properties of the aggregates and concretes. The results indicate that residues recycled soon after generation, these contribute positively to the mechanical properties of the concrete due to the existence of large amount of nonhydrated cement particles, such concretes obtained results superiors for the compression strenght and tensile strenght when compared to the concretes with natural aggregates.
2

Influência do carregamento precoce na retração por secagem do concreto

Silva, Lucilia Maria Silveira Bernardino da January 2016 (has links)
Apesar dos avanços tecnológicos e do conhecimento disponível sobre o concreto e suas propriedades, muitas estruturas apresentam-se degradadas prematuramente. Assim, são necessárias frequentes intervenções para reparo havendo, em consequência, consumo de quantidades expressivas de materiais, com importantes impactos financeiros e ambientais. A preocupação crescente com o desempenho das estruturas de concreto tem incentivado vários segmentos da sociedade a buscarem soluções que assegurem sua durabilidade. Nesse sentido, muitas pesquisas acadêmicas vêm sendo desenvolvidas para melhor entender o comportamento do concreto frente a diferentes condições de uso, considerando-se suas propriedades mecânicas e de durabilidade. Esta pesquisa teve por objetivo analisar o desempenho de concretos frente à retração por secagem, após terem sido submetidos ao pré-carregamento. Foram utilizados os cimentos CP V ARI e CP IV, nas relações a/c 0,35, 0,50 e 0,70, e adotadas as idades de cura de 7 e 28 dias. Nas idades 1, 3 e 7 dias, os concretos foram submetidos a carregamentos de 25%, 50% e 75% da carga média de ruptura à tração na flexão (NBR 12142, ABNT, 2010). Realizou-se o ensaio para determinação da retração por secagem (ASTM C157/C157M-08, 2014e1), em concretos de referência e nos pré-carregados. Foram também realizadas análises complementares, como determinação da velocidade da onda ultrassônica (NBR 8802, ABNT, 2013), porosimetria por intrusão de mercúrio e microtomografia de raios X. Comparando-se o desempenho dos concretos pré-carregados ao dos concretos de referência, o cimento CP V ARI apresentou redução da retração média, exceto para a relação a/c 0,35 com cura de 7 dias. Nos concretos com cimento CP IV, a retração média diminuiu para a relação a/c 0,70, com ambas as idades de cura. O pré-carregamento provocou, em maior ou menor grau, a associação de dois diferentes efeitos. Por um lado, a compactação ocasionou a quebra dos compostos menos resistentes da matriz, havendo um efeito físico de redução dos vazios capilares, além da exposição de grãos anidros. Em paralelo, ocorreu a microfissuração do concreto, favorecendo, também, a exposição de grãos anidros. A cura por imersão possibilitou a continuidade da hidratação, com a formação de novos produtos resistentes na matriz, reduzindo as porosidades total e efetiva e, portanto, a taxa da retração do concreto. Além da densificação da matriz, a cura prolongada possibilitou a hidratação dos grãos anidros de cimento expostos nas paredes das microfissuras, favorecendo a sua autocicatrização (self-healing), o que contribuiu com a recuperação da capacidade resistente dos concretos, frente aos esforços da secagem. Assim, a associação destes fatores promoveu a redução da retração por secagem nos concretos estudados, principalmente nos mais porosos. / The growing concern with the performance of structures has encouraged several segments of society to find solutions to improve concrete durability. Several studies have been made to provide a better understanding of the mechanical properties and concrete durability in different conditions. This study assessed the drying shrinkage performance of preloaded concrete. Cement types CP V ARI, equivalent to Portland type III (ASTM C150/C150M-16e1) and CP IV, equivalent to Portland type IP (ASTM C595/C595M-16) were used with w/b = 0.35, 0.50 and 0.70 and curing ages of 7 and 28 days. At the ages of 1, 3 and 7 days, concrete mixes were subject to loads of 25%, 50% and 75% of their mean ultimate flexural strength (Brazilian Standard NBR 12142, ABNT, 2010). Drying shrinkage in reference and preloaded concrete was determined according to ASTM C157/C157M-14e1. Additional tests included ultrasound pulse velocity (NBR 8802, ABNT, 2013), mercury intrusion porosimetry (MIP) and X-ray microtomography. Preloaded CP V ARI cement concrete showed a drop in mean shrinkage when compared with the reference mix, except for the mix with w/b = 0.35 cured for 7 days. For CP IV cement, mean shrinkage dropped with w/b =0.70 for both curing ages. Early loading caused a compaction effect, promoting the weakest compounds of the matrix to be broken, filling the capillary voids. In this process some unhydrous grains probably were exposed. On the other hand, microcracking also occurred, lefting unhydrated grains exposed in the microcracks walls. Due to immersion curing, the availability of water promoted the hydration continuity. New resistant hydrates filled the large voids and reduced the total and effective porosities in the cement matrix. The hydration of anhydrous grains in the microcracks walls had led to self-healing, with partial resistance capacity recovery. The combined effect of these factors promoted the drying shrinkage reducing, mainly for the more porous concrets.
3

Influência do carregamento precoce na retração por secagem do concreto

Silva, Lucilia Maria Silveira Bernardino da January 2016 (has links)
Apesar dos avanços tecnológicos e do conhecimento disponível sobre o concreto e suas propriedades, muitas estruturas apresentam-se degradadas prematuramente. Assim, são necessárias frequentes intervenções para reparo havendo, em consequência, consumo de quantidades expressivas de materiais, com importantes impactos financeiros e ambientais. A preocupação crescente com o desempenho das estruturas de concreto tem incentivado vários segmentos da sociedade a buscarem soluções que assegurem sua durabilidade. Nesse sentido, muitas pesquisas acadêmicas vêm sendo desenvolvidas para melhor entender o comportamento do concreto frente a diferentes condições de uso, considerando-se suas propriedades mecânicas e de durabilidade. Esta pesquisa teve por objetivo analisar o desempenho de concretos frente à retração por secagem, após terem sido submetidos ao pré-carregamento. Foram utilizados os cimentos CP V ARI e CP IV, nas relações a/c 0,35, 0,50 e 0,70, e adotadas as idades de cura de 7 e 28 dias. Nas idades 1, 3 e 7 dias, os concretos foram submetidos a carregamentos de 25%, 50% e 75% da carga média de ruptura à tração na flexão (NBR 12142, ABNT, 2010). Realizou-se o ensaio para determinação da retração por secagem (ASTM C157/C157M-08, 2014e1), em concretos de referência e nos pré-carregados. Foram também realizadas análises complementares, como determinação da velocidade da onda ultrassônica (NBR 8802, ABNT, 2013), porosimetria por intrusão de mercúrio e microtomografia de raios X. Comparando-se o desempenho dos concretos pré-carregados ao dos concretos de referência, o cimento CP V ARI apresentou redução da retração média, exceto para a relação a/c 0,35 com cura de 7 dias. Nos concretos com cimento CP IV, a retração média diminuiu para a relação a/c 0,70, com ambas as idades de cura. O pré-carregamento provocou, em maior ou menor grau, a associação de dois diferentes efeitos. Por um lado, a compactação ocasionou a quebra dos compostos menos resistentes da matriz, havendo um efeito físico de redução dos vazios capilares, além da exposição de grãos anidros. Em paralelo, ocorreu a microfissuração do concreto, favorecendo, também, a exposição de grãos anidros. A cura por imersão possibilitou a continuidade da hidratação, com a formação de novos produtos resistentes na matriz, reduzindo as porosidades total e efetiva e, portanto, a taxa da retração do concreto. Além da densificação da matriz, a cura prolongada possibilitou a hidratação dos grãos anidros de cimento expostos nas paredes das microfissuras, favorecendo a sua autocicatrização (self-healing), o que contribuiu com a recuperação da capacidade resistente dos concretos, frente aos esforços da secagem. Assim, a associação destes fatores promoveu a redução da retração por secagem nos concretos estudados, principalmente nos mais porosos. / The growing concern with the performance of structures has encouraged several segments of society to find solutions to improve concrete durability. Several studies have been made to provide a better understanding of the mechanical properties and concrete durability in different conditions. This study assessed the drying shrinkage performance of preloaded concrete. Cement types CP V ARI, equivalent to Portland type III (ASTM C150/C150M-16e1) and CP IV, equivalent to Portland type IP (ASTM C595/C595M-16) were used with w/b = 0.35, 0.50 and 0.70 and curing ages of 7 and 28 days. At the ages of 1, 3 and 7 days, concrete mixes were subject to loads of 25%, 50% and 75% of their mean ultimate flexural strength (Brazilian Standard NBR 12142, ABNT, 2010). Drying shrinkage in reference and preloaded concrete was determined according to ASTM C157/C157M-14e1. Additional tests included ultrasound pulse velocity (NBR 8802, ABNT, 2013), mercury intrusion porosimetry (MIP) and X-ray microtomography. Preloaded CP V ARI cement concrete showed a drop in mean shrinkage when compared with the reference mix, except for the mix with w/b = 0.35 cured for 7 days. For CP IV cement, mean shrinkage dropped with w/b =0.70 for both curing ages. Early loading caused a compaction effect, promoting the weakest compounds of the matrix to be broken, filling the capillary voids. In this process some unhydrous grains probably were exposed. On the other hand, microcracking also occurred, lefting unhydrated grains exposed in the microcracks walls. Due to immersion curing, the availability of water promoted the hydration continuity. New resistant hydrates filled the large voids and reduced the total and effective porosities in the cement matrix. The hydration of anhydrous grains in the microcracks walls had led to self-healing, with partial resistance capacity recovery. The combined effect of these factors promoted the drying shrinkage reducing, mainly for the more porous concrets.
4

Influência do carregamento precoce na retração por secagem do concreto

Silva, Lucilia Maria Silveira Bernardino da January 2016 (has links)
Apesar dos avanços tecnológicos e do conhecimento disponível sobre o concreto e suas propriedades, muitas estruturas apresentam-se degradadas prematuramente. Assim, são necessárias frequentes intervenções para reparo havendo, em consequência, consumo de quantidades expressivas de materiais, com importantes impactos financeiros e ambientais. A preocupação crescente com o desempenho das estruturas de concreto tem incentivado vários segmentos da sociedade a buscarem soluções que assegurem sua durabilidade. Nesse sentido, muitas pesquisas acadêmicas vêm sendo desenvolvidas para melhor entender o comportamento do concreto frente a diferentes condições de uso, considerando-se suas propriedades mecânicas e de durabilidade. Esta pesquisa teve por objetivo analisar o desempenho de concretos frente à retração por secagem, após terem sido submetidos ao pré-carregamento. Foram utilizados os cimentos CP V ARI e CP IV, nas relações a/c 0,35, 0,50 e 0,70, e adotadas as idades de cura de 7 e 28 dias. Nas idades 1, 3 e 7 dias, os concretos foram submetidos a carregamentos de 25%, 50% e 75% da carga média de ruptura à tração na flexão (NBR 12142, ABNT, 2010). Realizou-se o ensaio para determinação da retração por secagem (ASTM C157/C157M-08, 2014e1), em concretos de referência e nos pré-carregados. Foram também realizadas análises complementares, como determinação da velocidade da onda ultrassônica (NBR 8802, ABNT, 2013), porosimetria por intrusão de mercúrio e microtomografia de raios X. Comparando-se o desempenho dos concretos pré-carregados ao dos concretos de referência, o cimento CP V ARI apresentou redução da retração média, exceto para a relação a/c 0,35 com cura de 7 dias. Nos concretos com cimento CP IV, a retração média diminuiu para a relação a/c 0,70, com ambas as idades de cura. O pré-carregamento provocou, em maior ou menor grau, a associação de dois diferentes efeitos. Por um lado, a compactação ocasionou a quebra dos compostos menos resistentes da matriz, havendo um efeito físico de redução dos vazios capilares, além da exposição de grãos anidros. Em paralelo, ocorreu a microfissuração do concreto, favorecendo, também, a exposição de grãos anidros. A cura por imersão possibilitou a continuidade da hidratação, com a formação de novos produtos resistentes na matriz, reduzindo as porosidades total e efetiva e, portanto, a taxa da retração do concreto. Além da densificação da matriz, a cura prolongada possibilitou a hidratação dos grãos anidros de cimento expostos nas paredes das microfissuras, favorecendo a sua autocicatrização (self-healing), o que contribuiu com a recuperação da capacidade resistente dos concretos, frente aos esforços da secagem. Assim, a associação destes fatores promoveu a redução da retração por secagem nos concretos estudados, principalmente nos mais porosos. / The growing concern with the performance of structures has encouraged several segments of society to find solutions to improve concrete durability. Several studies have been made to provide a better understanding of the mechanical properties and concrete durability in different conditions. This study assessed the drying shrinkage performance of preloaded concrete. Cement types CP V ARI, equivalent to Portland type III (ASTM C150/C150M-16e1) and CP IV, equivalent to Portland type IP (ASTM C595/C595M-16) were used with w/b = 0.35, 0.50 and 0.70 and curing ages of 7 and 28 days. At the ages of 1, 3 and 7 days, concrete mixes were subject to loads of 25%, 50% and 75% of their mean ultimate flexural strength (Brazilian Standard NBR 12142, ABNT, 2010). Drying shrinkage in reference and preloaded concrete was determined according to ASTM C157/C157M-14e1. Additional tests included ultrasound pulse velocity (NBR 8802, ABNT, 2013), mercury intrusion porosimetry (MIP) and X-ray microtomography. Preloaded CP V ARI cement concrete showed a drop in mean shrinkage when compared with the reference mix, except for the mix with w/b = 0.35 cured for 7 days. For CP IV cement, mean shrinkage dropped with w/b =0.70 for both curing ages. Early loading caused a compaction effect, promoting the weakest compounds of the matrix to be broken, filling the capillary voids. In this process some unhydrous grains probably were exposed. On the other hand, microcracking also occurred, lefting unhydrated grains exposed in the microcracks walls. Due to immersion curing, the availability of water promoted the hydration continuity. New resistant hydrates filled the large voids and reduced the total and effective porosities in the cement matrix. The hydration of anhydrous grains in the microcracks walls had led to self-healing, with partial resistance capacity recovery. The combined effect of these factors promoted the drying shrinkage reducing, mainly for the more porous concrets.
5

Concreto com agregados graúdos reciclados de concreto : influência da idade de reciclagem nas propriedades dos agregados e concretos reciclados. / Concrete with recycled concrete coarse aggregates : influence of age of recycling in the properties of recycled aggregates and concretes

Alexandre Marques Buttler 12 May 2003 (has links)
Os resíduos de concreto apresentam grande potencial para serem reciclados quando comparados com outros resíduos, entretanto, o número de estudos realizados no Brasil é muito pequeno dificultando a utilização deste material em dosagens estruturais. Em virtude disso, desenvolveu-se um estudo teórico-experimental visando caracterizar algumas propriedades do agregado e do concreto reciclado; no estudo teórico exploraram-se aspectos relacionados à geração, deposição, processos para recuperação, britagem, casos práticos, pesquisas envolvendo reciclados de concreto e as recomendações normativas existentes. No desenvolvimento experimental, analisou-se a influência do período decorrido entre a moldagem e a reciclagem do concreto nas propriedades dos agregados e concretos. Os resultados indicam que resíduos reciclados logo após sua geração, contribuem positivamente para as propriedades mecânicas do concreto, devido à existência de grande quantidade de partículas não-hidratadas de cimento, tais concretos obtiveram resultados superiores para a resistência à compressão e tração quando comparados aos concretos com agregados naturais. / The concrete residues show a large potential to be recycled when compared with other residues; however, the number of studies in Brazil is very small hindering the use of this material in structural dosage. By virtue of that, it was developed a theoretical-experimental study to characterize some properties of aggregate and recycled concrete; in the theoretical study it was explored aspects related to the generation, deposition, processes for recovery, crushing, practical cases, researches involving recycled of concrete and the existent normative recommendations. In the experimental development, it was analyzed the influence of the period elapsed between the molding and the recycling of the concrete in the properties of the aggregates and concretes. The results indicate that residues recycled soon after generation, these contribute positively to the mechanical properties of the concrete due to the existence of large amount of nonhydrated cement particles, such concretes obtained results superiors for the compression strenght and tensile strenght when compared to the concretes with natural aggregates.
6

Controle da fissuração em compósitos com fibras orgânicas aplicando conceito de materiais com gradação funcional. / Control of cracking in fiber cement apply concepts of functionally graded materials.

Giordano, Brunoro Leite 09 December 2011 (has links)
O objetivo deste trabalho é controlar a incidência de fissuras em fibrocimentos aplicando o conceito de materiais com gradação funcional através da protensão química gerada pela aplicação de silicato de sódio alcalino entre as camadas dos fibrocimentos. Atualmente é bastante comum os fibrocimentos apresentarem fissuras ao longo das bordas devido aos gradientes de umidade gerados durante a estocagem das pilhas de telhas no pátio das indústrias. O potencial da protensão química foi avaliado através da porosidade total, da quantificação das fases hidratadas, da retração por secagem e do desempenho mecânico. A aplicação de silicato de sódio alcalino no ligante CPII F provocou retração por secagem 1,5 vezes maior que a referência aos 91 dias. O módulo de ruptura (MOR) não sofreu alteração, mas o limite de proporcionalidade da matriz (LOP) aumentou em torno de 95%. O módulo de elasticidade dinâmico foi 13 % maior. O aumento da retração por secagem e o ganho de desempenho mecânico apontam o potencial da protensão química para o controle da fissuração em fibrocimentos produzidos pelo processo Hatschek. / The objective of this work is controlling the incidence of cracks in fiber cement, using the concept of functionally graded materials through the chemical prestressing, generated by application of alkaline sodium silicate among fiber cement layers. Currently, its very common the fiber cements present cracks along the edges due to moisture gradients, caused during storage of piles of tiles in the courtyard of the industry. The chemical prestressing potential was evaluated through of the total porosity, the quantification of hydrate phases, the drying shrinkage and the mechanical performance. The application of alkaline sodium silicate in the cement CPII F caused drying shrinkage 1,5 times greater than the reference to 91 days. The modulus of rupture (MOR) didnt suffer change, but the proportional limit of matrix (LOP) increased by around 95%. The dynamic modulus of elasticity was 13% higher. The increase of drying shrinkage and the mechanical performance gain indicate the chemical prestressing potential to control the cracking in fiber cement produced by the process Hatschek.
7

Controle da fissuração em compósitos com fibras orgânicas aplicando conceito de materiais com gradação funcional. / Control of cracking in fiber cement apply concepts of functionally graded materials.

Brunoro Leite Giordano 09 December 2011 (has links)
O objetivo deste trabalho é controlar a incidência de fissuras em fibrocimentos aplicando o conceito de materiais com gradação funcional através da protensão química gerada pela aplicação de silicato de sódio alcalino entre as camadas dos fibrocimentos. Atualmente é bastante comum os fibrocimentos apresentarem fissuras ao longo das bordas devido aos gradientes de umidade gerados durante a estocagem das pilhas de telhas no pátio das indústrias. O potencial da protensão química foi avaliado através da porosidade total, da quantificação das fases hidratadas, da retração por secagem e do desempenho mecânico. A aplicação de silicato de sódio alcalino no ligante CPII F provocou retração por secagem 1,5 vezes maior que a referência aos 91 dias. O módulo de ruptura (MOR) não sofreu alteração, mas o limite de proporcionalidade da matriz (LOP) aumentou em torno de 95%. O módulo de elasticidade dinâmico foi 13 % maior. O aumento da retração por secagem e o ganho de desempenho mecânico apontam o potencial da protensão química para o controle da fissuração em fibrocimentos produzidos pelo processo Hatschek. / The objective of this work is controlling the incidence of cracks in fiber cement, using the concept of functionally graded materials through the chemical prestressing, generated by application of alkaline sodium silicate among fiber cement layers. Currently, its very common the fiber cements present cracks along the edges due to moisture gradients, caused during storage of piles of tiles in the courtyard of the industry. The chemical prestressing potential was evaluated through of the total porosity, the quantification of hydrate phases, the drying shrinkage and the mechanical performance. The application of alkaline sodium silicate in the cement CPII F caused drying shrinkage 1,5 times greater than the reference to 91 days. The modulus of rupture (MOR) didnt suffer change, but the proportional limit of matrix (LOP) increased by around 95%. The dynamic modulus of elasticity was 13% higher. The increase of drying shrinkage and the mechanical performance gain indicate the chemical prestressing potential to control the cracking in fiber cement produced by the process Hatschek.
8

Análise experimental e analítica da fissuração de pavimentos de concreto continuamente armados em clima tropical. / Experimental and analytical analysis of continuously reinforced concrete pavements cracking in tropical weather.

Cargnin, Andréia Posser 23 November 2016 (has links)
Os primeiros estudos sobre pavimentos de concreto continuamente armados (PCCA) foram desenvolvidos em zonas cujo clima característico é o temperado (EUA, Holanda e Bélgica), não se tendo estudos técnicos acerca do comportamento do pavimento em ambiente tropical. A premissa de funcionamento do PCCA está baseada na não execução de juntas de retração, obrigatórias em pavimentos de concreto simples (PCS), ou seja, as fissuras devido à retração do concreto ocorrem aleatoriamente, sendo controladas pela elevada taxa de armadura longitudinal disposta longitudinalmente ao longo de toda a extensão do pavimento. Como essa armadura não possui função estrutural, pois é colocada acima da linha neutra da placa, no banzo comprimido, sua função é manter as fissuras fortemente apertadas, garantindo suavidade ao rolamento e elevada transferência de carga (LTE), a qual ocorre pelo intertravamento dos agregados nas faces fissuradas, proporcionando assim um pavimento de alta durabilidade e que dispende baixíssimos custos com manutenção. No Brasil, a primeira experiência com PCCA teve início no ano de 2010, quando foram construídas quatro seções de 50 m de extensão cada, consideradas curtas em comparação aos 400 m de extensão de um PCCA rodoviário que podem ser alcançados ao final de um dia de trabalho. O monitoramento contínuo de tais seções mostrou haver uma diferença muito significativa de comportamento, comparado aos PCCA tradicionais, no que tange o tempo decorrido para estabelecimento do padrão de fissuração (a primeira fissura surgiu um ano após a construção), bem como espaçamento médio entre as fissuras, devido à curta extensão das placas e a inexistência de um sistema de ancoragem nas extremidades. Assim, para melhor compreender o comportamento de pavimentos de concreto com armadura contínua com padrões condizentes à realidade rodoviária em ambiente tropical, em janeiro de 2016, foi construído no campus da Universidade de São Paulo o primeiro PCCA de longa extensão do Brasil, com 200 m de comprimento. Foram empregados quatro diferentes tipos de concreto, variando o tipo de cimento e o tipo de agregado, bem como foram empregados aço galvanizado e aço comum. Para entender o comportamento do pavimento sob as condições climáticas brasileiras foram realizados três estudos: levantamento de fissuras (espaçamento e abertura), modelagem analítica do espaçamento entre fissuras através de modelos de previsão de retração em concreto e testes com FWD para avaliação da eficiência de transferência de carga (LTE) entre as fissuras. A análise do padrão de fissuração mostrou que o desenvolvimento das fissuras aconteceu conforme a literatura técnica, tendo início na primeira semana após a concretagem e atingindo aproximadamente 60% do número total de fissuras antes do primeiro mês. As seções centrais possuem o maior número de fissuras, pois estão ancoradas pelas seções de extremidade, onde o surgimento das fissuras é mais lento por conta da falta de ancoragem. As aberturas das fissuras mostraram-se maiores nas posições com aço galvanizado devido à menor aderência aço-concreto nesse caso, em comparação às posições com aço comum. O modelo de previsão de retração no concreto que melhor se aproximou do espaçamento médio desenvolvido em campo foi o modelo do Eurocode 2, com diferenças em torno de 30%, aproximadamente. As análises de LTE mostraram um desempenho muito satisfatório, apesar de a LTE nas regiões com aço galvanizado ter resultado menor do que a LTE nas regiões com aço comum. / The first studies on continuously reinforced concrete pavements (CRCP) were developed in areas in which the typical weather is temperate (United States, Netherlands and Belgium), with no technical studies carried out in tropical weather. CRCP structural premise is based on a slab without construction joints which are required in jointed plain concrete pavements (JPCP); i.e., CRCP cracks due to concrete shrinkage occur randomly being controlled by the high longitudinal reinforcement percentage, positioned longitudinally along the pavement length. As the longitudinal reinforcement has no structural role, because it is placed above the slab neutral axis, in the compression zone, its main function is to keep cracks strongly tight, ensuring a smooth ride and high load efficiency transfer (LTE) at cracks, which occurs through aggregates interlocking, thereby providing a highly durable pavement with low maintenance costs. The first experience with CRCP in Brazil started in 2010, when four experimental sections were constructed. Each section is 50 meters long, short when compared to the traditional CRCP that can extend for over 400 meters providing that concrete pouring does not stop. Continuous monitoring of these sections has shown that the short CRCP behaves differently from traditional CRCP, regarding the time taken for the cracking pattern full development (the first crack was visible on the surface one year after the construction), as well as average cracking space due to the slab\'s short extension and lack of anchorage. Therefore, in order to fully analyze the behavior of a traditional CRCP under tropical weather, in January 2016, the first long extension CRCP in Brazil was built, at the University of São Paulo campus, with 200 meters length. Four types of concrete were applied in the construction, varying cement and aggregate type. Galvanized and ordinary steel were used as well. To analyze the pavement behavior under Brazilian climatic conditions, three studies were carried out: cracks surveys (spacing and width), analytical modeling crack spacing through shrinkage prediction models and Falling Weight Deflectometer testing to evaluate the crack\'s load transfer efficiency (LTE). Cracking pattern analysis has shown cracks development consistent with technical literature. The first cracks appeared during the first week after concrete placement and, before the first month, about 60% of the total cracks number had developed. Central sections presented greatest number of cracks as they are anchored by the outer sections, where cracking occurs slower due to the lack of anchorage. Cracks width was higher in areas with galvanized steel due to the weaker steel-concrete bond, when compared to areas with common steel. The shrinkage prediction model for concrete that better approached the average field crack spacing was the Eurocode 2, with mean difference of 30%. LTE analysis has shown a quite satisfactory performance, even though LTE in areas with galvanized steel is lower than LTE in areas with common steel.
9

Tensões originadas pela retração em elementos de concreto com deformação restringida considerando-se o efeito da fluência. / Stress caused by shrinkage in concrete elements with restrained strain considering creep.

Amaral, José Carlos do 10 May 2011 (has links)
As estruturas feitas com pré-moldados são geralmente compostas por uma base (peça pré-fabricada) mais concreto moldado no local, como é o caso de lajes (pré- lajes, lajes alveolares, aduelas de pontes). No concreto novo junto à interface de contato entre os elementos surgem tensões de tração devidas à restrição a deformação de retração por secagem imposta pela base. Portanto, ressalta-se a importância em conhecer tais tensões, pois, as mesmas podem provocar a fissuração do concreto. Por essa relevância, estuda-se neste trabalho o comportamento da tensão de tração resultante na estrutura composta, onde o elemento de concreto simples novo (sem armadura) está com restrição contínua na base e o mesmo sofre tensões originadas pela retração por secagem, as quais são reduzidas pelas deformações de natureza viscosa (fluência). Este estudo é feito ao longo do tempo utilizando o modelo de previsão de retração e fluência da ABNT NBR 6118:2003 variando o tipo de cimento, classe de resistência à compressão, relação água/cimento (representada pelo abatimento), umidade relativa do ar, temperatura ambiente, altura da camada do elemento de concreto e o grau de restrição da base. As tensões de tração resultantes foram determinadas por método iterativo, proposto inicialmente pelo Engº José Zamarion Ferreira DINIZ (Diretor da Empresa Zamarion e Millen Consultores S/S Ltda) e melhorado por esse autor, considerando-se a evolução no tempo da retração e da fluência do concreto, a partir disso foi possível determinar um modelo simplificado que permite uma estimativa rápida das referidas tensões utilizando os conceitos de coeficiente de envelhecimento e grau de restrição. / Some Precast Structures usually are composed of two parts, a base (hardened concrete) and a new concrete (softened) build \"in locu\" to coating, for example, slabs and pre-slabs. In the new concrete next to the interface between the elements (base/new) appears tensile stress due to the restrained strain imposed for the base. Therefore, its important knows this tensile stress because can cracking the concrete. Therefore, the behavior of the resultant tensile stress in the composed structure is studied in this work, where the element of new simple concrete (without reinforced) its restrained by the continuous base and suffers stress caused by drying shrinkage, which they are reduced for the viscous strain (creep). This study it is made throughout the time having used the model of prediction shrinkage and creep of ABNT NBR 6118:2003 varying the type of cement, classroom of compressive strength, ration water/cement (represented by slump), relative humidity, ambient temperature, height of the concrete element and the degree of base restraint. The resultant tensile stress had been determined by iterative method, first proposed by Eng. José Zamarion Ferreira Diniz (Director of the Company Zamarion e Millen Consultores S/S Ltda.) and improved by this writer, considering development a long the time of the shrinkage and creep of concrete, therefore, it was possible to determine a simplified model that allows to a fast estimate of the related stress using the concepts of aging coefficient and degree of restraint.
10

Estudo da retração em fibrocimento reforçado com fibra polimérica. / Shrinkage in cement based composite reinforced with synthetic fibers.

Souza, Rui Barbosa de 07 November 2013 (has links)
O objetivo do trabalho é analisar e compreender os efeitos das características do fibrocimento reforçado com fibras sintéticas na retração por secagem deste compósito. A importância social do fibrocimento como material de construção, justifica a realização do presente trabalho, de modo a expor como acontece a retração por secagem neste compósito, e desta forma auxiliar o meio técnico na mitigação das manifestações patológicas relacionadas à retração e contribuindo para a redução do importante problema da indústria produtora de fibrocimento, que é a fissuração de borda nas telhas onduladas. Para tal buscou-se demostrar o efeito da porosidade e distribuição de tamanho de poros na retração por secagem. Além disso, foram realizados experimentos onde se variou o tipo de cimento utilizado, as quantidades de todas as matérias-primas envolvidas, além da aplicação de tratamentos modificadores da movimentação higroscópica, manipulando diretamente a tensão capilar causadora da retração. Concluiu-se que a porosidade elevada do fibrocimento faz com que a retração por secagem deste compósito seja fortemente influenciada pela porosidade total do mesmo, com correlação direta com a quantidade de mesoporos. Além disso, no estudo de caso realizado concluiu-se que a redução da retração devido à redução da tensão superficial da água do poro, se refletiu em menor fissuração de borda nas telhas onduladas. / The objective is to analyze and comprehend the effects of properties of cement based composite reinforced with synthetic fibers, on drying shrinkage of such composite. The social importance of fiber cement as construction material justifies the execution of the present work, in order to expose how drying shrinkage occurs on this composite and by those means to assist the technical community on mitigating pathological manifestations related to shrinkage, thus contributing for the reduction of an important problem on fiber cement industry, the edge cracking on corrugated sheets. In order to achieve this goal, it was sought to demonstrate the effect of porosity and pore size distribution on drying shrinkage. Moreover, experiments were performed, varying the type of cement used and the quantities of all materials involved, in addition to the application of treatments that modify hygroscopic movement, directly manipulating the capillary tension which causes shrinkage. It was concluded that the elevated porosity of the fiber cement causes drying shrinkage of this composite to be strongly influenced by its total porosity, directly correlated to the quantity of mesopores. Furthermore, in the case study performed it was concluded that shrinkage reduction due to the reduction of pore water surface tension was reflected into minor edge cracking on corrugated sheets.

Page generated in 0.1101 seconds