• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Eine Phantomstudie zur Strahlenexposition des Untersuchers bei Rotationsaquisitionen mit einer Flachdetektor-Angiographie-Anlage / A phantom-study about the radiation exposure to the examiner at rotational acquisitions using a flat-panel detector angiographic system

Friedrichs, Tatiana 24 July 2014 (has links)
Neben der konventionellen Digitalen Subtraktions-Angiografie (DSA) werden insbesondere seit Einführung der Angiografiesysteme mit Flachdetektor-Technologie zunehmend auch Rotationsangiografien und DYNA-CTs durchgeführt. Ziel der Studie ist die Bestimmung der Strahlenexposition für den Untersucher bei DSA-Serien im Vergleich zu Rotationsangiografien an einem biplanen Angiografiesystem unter Berücksichtigung gerätetechnischer Strahlenschutzvorrichtungen. Die Untersuchung erfolgte an einem biplanen Angiographiesystem mit Flachdetektor-Technologie (AxiomArtis dBA, Siemens). Die Strahlenexposition wurde als Ortsdosis in Höhe der Augen, Schilddrüse und Gonaden eines stehenden Untersuchers mit dem Dosimeter UMO LB 123 (Berthold) bestimmt. Alle Messungen wurden sowohl mit als auch ohne deckengeführtes Strahlenschutzschild und Unterkörperschutz mit Aufsatz durchgeführt. Die Messorte wurden in unterschiedlichen Abständen und Winkeln zum Isozentrum gewählt. Der Patient wurde durch ein Alderson-Phantom simuliert. Die Messergebnisse ergaben eine 90%ige Reduzierung der Strahlenexposition des Untersuchers durch die Strahlenschutzvorrichtung am Tisch. Für einen wirksamen Gonadenschutz ist der Aufsatz zum Unterkörperschutz unverzichtbar. Die optimale Schutzwirkung ist nur an der Position des Untersuchers nachweisbar; Personal direkt neben dem Untersucher ist einer bis zu 10mal größeren Strahlenexposition ausgesetzt. Die Strahlenexposition des Untersuchers ist bei der Durchführung einer Rotationsangiografie (8s DS H) auch unter Berücksichtigung aller gerätetechnischen Strahlenschutzvorrichtungen 9 bis 10fach höher, verglichen zu einer DSA-Serie in Standardprojektionen (6s, 3 Bilder/s). Die Strahlenexposition des Untersuchers an einem biplanen Angiografiesystem kann durch gerätetechnische Strahlenschutzvorrichtungen erheblich reduziert werden. Hochdosisprotokolle für Rotationsangiografien sollten auf ihre Notwendigkeit überprüft werden.
2

Integration of dynamic and functionnal patien-specific 3D models in support of interventional electrophysiological procedures / Intégration de modèles dynamiques et fonctionels spécifiques au patient en support de procedures d’électrophysiologie interventionelle

Wielandts, Jean-Yves 27 September 2016 (has links)
Vu le caractère non-invasif des procédures d’électrophysiologie interventionnelle, la visualisation de régions anatomiques d'intérêt et une orientation adéquate en cours de procédure sont nécessaires. L'objectif de cette thèse est d'étudier, d'optimiser et d'étendre l’utilisation des modalités d'imagerie radiographique. La dose de radiation effective (ED) est calculée d’une façon spécifique au patient pour l’angiographie rotationnelle 3D (3DRA) et il est démontré qu'en ajustant l’acquisition en 3DRA et en fluoroscopie, une réduction de dose importante est possible sans compromettre la qualité d’image nécessaire à la procédure. Un protocole d'acquisition et post traitement pour obtenir une imagerie dynamique basée sur le 3DRA est présenté,permettant une réduction du bruit d'image et une segmentation d'images automatique. L'extraction d'informations dynamiques, structurelles et fonctionnelles à partir d'images MDCT, relatives à la gestion de la fibrillation auriculaire (FA) est étudiée. La fonction auriculaire globale est examinée et des cartes de mouvement régional et de tissu adipeux épicardique sont produites et liés à la FA à différents stades. Une méthode automatisée est présentée pour mesurer l’orifice de l’appendice auriculaire gauche au long du cycle cardiaque et pour optimiser le déploiement de dispositifs de fermeture. Optimiser l’usage des rayons X, les protocoles d'acquisition et les méthodes de post traitement d’images, permet d’obtenir des informations supplémentaires pertinentes aux procédures d'électrophysiologie interventionnelle depuis les modalités d'imagerie radiographiques sans compromettre la qualité d’image ou le flux de travail procédural. / Due to their non-invasive character, interventional electro physiological procedures require visualisation of anatomical regions of interest and adequate guidance of procedural manoeuvres. The aim of this thesis was to study, optimise and expand the use of radiographic imaging modalities. The first part focuses on the influence of C-arm system image acquisition parameters on radiation dose incurred by the patient. We developed a patient-specific way to calculate effective dose (ED) in 3Drotational angiography (3DRA) and showed in 3DRA and fluoroscopy that by applying adequate protocol adjustments, an important dose reduction could be obtained without compromising necessary image quality. The second part focuses on the development and validation of an acquisition and post-processing protocol for dynamic imaging using 3DRA. This method enables automatic image noise reduction and image segmentation. The third part focuses on the extraction of dynamic,structural and functional information from MDCT images, relevant to management of atrial fibrillation (AF). We studied atrial function and generated maps of regional atrial motion and epicardial adipose tissue and related them to AF burden. We also developed an automated method to measure LA appendage orifice dimensions through out the cardiac cycle to optimise measurements for deployment of closure devices.Overall we demonstrate that by optimising radiation usage, acquisition protocols and image post-processing methods, additional information relevant to interventional electrophysiological procedures can be extracted from radiographic imaging modalities without compromising image quality or procedural workflow.
3

Malformation artério-veineuses cérébrales : d'une amélioration des techniques d'imagerie vers un changement de paradigme des traitements / Brain arteriovenous malformations : from imaging technique improvement toward treatment paradigm shift

Clarençon, Frédéric 11 December 2014 (has links)
Les malformations artério-­‐veineuses cérébrales (MAVc) sont des pathologies vasculaires agressives présentant un risque hémorragique lourd de conséquence en terme de morbi-­‐mortalité. Les outils d’imagerie disponibles actuellement ne permettent de comprendre que difficilement leur angio-­‐ architecture. Nous avons développé dans notre travail deux outils d’imagerie permettant d’affiner la compréhension de l’anatomie des ces malformations : un algorithme de segmentation semi-­‐automatisé et un algorithme d’anamorphose sphérique convexe. Ces algorithmes ont été élaborés pour être utilisés sur les acquisitions d’angiographie rotationnelle 3D ; ils permettent de mieux visualiser la veine de drainage principale des MAVc, notamment d’identifier une sténose ou une ectasie focale sur cette veine, et également de déceler de façon plus fiable la présence d’un anévrysme intra-­‐nidal. Ces améliorations dans l’analyse de l’angio-­‐architecture des MAVc permettront vraisemblablement de réduire le risque thérapeutique pour ces malformations. En vue de tester le potentiel des agents anti-­‐angiogéniques pour le traitement des MAVc, nous avons élaboré un modèle porcin simplifié de MAVc consistant en une occlusion unilatérale d’artère carotide primitive par voie endovasculaire. La comparaison entre le volume de rete mirabile à J0 et à 3 mois et les valeurs obtenues pour un groupe témoin a montré une augmentation significative du volume du rete mirabile chez les porcs ayant eu l’occlusion carotidienne. D’autre part, une tendance nette à l’augmentation des taux de VEGF (vascular endothelial growth factor) à proximité du rete mirabile était observée dans le groupe occlusion. Enfin, des modifications anatomopathologiques proches de celles des MAVc humaines étaient visualisées sur les pièces autopsiques des rete mirabile dans le groupe occlusion. / Brain arteriovenous malformations (bAVMs) are aggressive vascular malformations presenting a haemorrhagic complication risk that may lead to severe consequences in terms of morbi-­‐mortality. Available imaging tools poorly help in understanding their angio-­‐architecture. We have developed two imaging tools improving our understanding of the anatomy of these malformations: a semi-­‐automated segmentation algorithm and a convex spherical anamorphosis algorithm. These algorithms have been elaborated for use on 3D rotational angiography acquisitions; they provide a better visualisation of the bAVMs’ main draining vein, especially for venous stenosis or for focal ectasia. They also help in depicting accurately intranidal aneurysms. These improvements in the analysis of the bAVMs’ angioarchitecure may help in reducing the therapeutic risk for these malformations. For a further testing of the potential of anti-­‐angiogenic agents for the treatment of bAVMs, we have elaborated a simplified swine AVM model consisting in the occlusion of a common carotid artery by endovascular means. The comparison between the volume of the rete mirabile at D0 and 3 months and those measured in a control group showed a significant increasing of the retia in the occlusion group. Moreover, a tendency was observed concerning an increase in VEGF (vascular endothelial growth factor) serum levels close to the rete mirabile in the occlusion group. Finally, pathological changes close to those seen in human bAVMs were observed on autopsy samples in the occlusion group.

Page generated in 0.0912 seconds