1

High-Temperature Displacement Sensor Using a White-Light Scanning Fiber Michelson Interferometer

Pedrazzani, Janet Renee 08 January 2000 (has links)
As specialized materials are developed for various applications, it becomes desirable to test them under adverse conditions, such as at elevated temperatures and in harsh environments. It is increasingly important that sensors be developed to meet the growing needs of research and industry. The ability of sapphire to withstand elevated temperatures and many chemically harsh environments has long been recognized. However, currently available sapphire fiber possesses poor optical quality and is not available with a cladding. It has found use in a variety of temperature sensors, but the investigation of sapphire-based strain and displacement sensors has been limited. The primary development of a white-light Michelson interferometer that utilizes a sapphire fiber sensing head is presented in this thesis. Development includes efforts to combat the poor optical quality of the sapphire fiber, minimize polarization mode fading, and preferentially excite the fundamental mode of the sapphire fiber. This thesis demonstrates the feasibility of fabricating a Michelson white-light interferometer capable of measuring displacements in environments ranging from room temperature to 800 degrees Celsius. The sensor developed in this work is capable of measuring displacements exceeding 6.4 millimeters at room temperature, and exceeding 1 millimeter at 800 degrees Celsius. This thesis also presents the application of this sensor to the alignment of a sapphire-fiber based Fabry-Perot sensor. This technique allows the Fabry-Perot sensor to be aligned so that usable fringes are always obtained. Alignment of the sapphire-fiber based Fabry-Perot sensors has been considered prohibitively difficult. / Master of Science
2

Sapphire Fiber Optic Sensor for High Temperature Measurement

Tian, Zhipeng 10 January 2018 (has links)
This dissertation focuses on developing new technologies for ultra-low-cost sapphire fiber-optic high-temperature sensors. The research is divided into three major parts, the souceless sensor, the simple Fabry-Perot (F-P) interrogator, and the sensor system. Chapter 1 briefly reviews the background of thermal radiation, fiber optic F-P sensors, and F-P signal demodulation. The research goal is highlighted. In Chapter 2, a temperature sensing system is introduced. The environmental thermal radiation was used as the broadband light source. A sapphire wafer F-P temperature sensor head was fabricated, with an alumina cap designed to generate a stable thermal radiation field. The radiation-induced optical interference pattern was observed. We demodulated the temperature sensor by white-light-interferometry (WLI). Temperature resolution better than 1°C was achieved. Chapter 3 discusses a novel approach to demodulate an optical F-P cavity at low-cost. A simple interrogator is demonstrated, which is based on the scanning-white-light-interferometry (S-WLI). The interrogator includes a piece of fused silica wafer, and a linear CCD array, to transform the F-P demodulation from the optical frequency domain to the spatial domain. By using the light divergence of an optical fiber, we projected a tunable reference F-P cavity onto an intensity distribution along a CCD array. A model for S-WLI demodulation was established. Performance of the new S-WLI interrogator was investigated. We got a good resolution similar to the well-known traditional WLI. At last, we were able to combine the above two technologies to a sapphire-wafer-based temperature sensor. The simple silica wafer F-P interrogator was optimized by focusing light to the image sensor. This approach improves the signal to noise ratio, hence allows the new integrator to work with the relatively weak thermal radiation field. We, therefore, proved in the experiment, the feasibility of the low-cost sourceless optical Fabry-Perot temperature sensor with a simple demodulation system. / PHD / Temperature measurements for high temperature harsh environments is a challenge industrial task. In this work, a low-cost sapphire fiber high temperature sensor is introduced which uses single crystal sapphire fiber as the light guiding and a sapphire-wafer-based Fabry-Perot (F-P) interferometer as the temperature sensing element. The research goal is to provide an optical sensing system whose price is competitive to the high temperature thermocouples. Two technologies were developed to reduce the cost of the sensing system, the sourceless sensor head design and the low-cost wafer-based F-P interrogator. The sourceless sensor head makes use of the environmental thermal radiation as a broadband light source, together with the white light interferometry signal demodulation method, for temperature measurements. In this case, the system avoids using not only an external light, but also the light driver and the light coupling element. A low-cost F-P cavity interrogation method was introduced to demodulate the sapphire-wafer-based temperature sensing F-P cavity. The signal demodulation is based on the scanning white light interferometry, but a reliable and low-cost reference F-P cavity is introduced. It includes only a piece of transparent wafer and a CCD array to transfer the interference fringe from the spectra domain to the spatial domain and therefore a low cost CCD can be directly applied to identify the optical path distance of the sensing OPD. Eventually, the above two technologies were able to put together and an extremely low-cost F-P temperature sensing system was built. It has a good potential for further applications and commercialization.
3

New biomedical applications of near-infrared femtosecond laser ablation

Qiu, Jinze 14 February 2012 (has links)
The main purpose of this research was to investigate new medical applications of femtosecond laser ablation. A near-infrared femtosecond laser was tested and proved to be able to overcome the existing limitations and outperform the conventional long-pulse lasers in the areas of human urinary calculus (kidney stone) lithotripsy and skin treatment. The two primary objectives of my research are: 1) to investigate the feasibility of using femtosecond pulsed laser radiation to ablate urinary calculus of various compositions. The laser-calculus interaction mechanism was characterized using pump probe imaging and fast flash imaging. A novel fiber delivery system was developed to transmit and focus high energy femtosecond pulses for urinary calculus lithotripsy. The successful demonstration of the femtosecond laser lithotripsy provided a promising treatment method better than the existing long-pulse laser lithotripsy in a few different aspects, including less collateral damage to surrounding tissue, small-size debris and more controlled experimental condition. 2) to investigate the depth limitation of femtosecond subsurface ablation in scattering skin sample and develop a prototype tissue optical clearing device to enhance femtosecond beam penetration for deeper subsurface cavitation production in the skin. The successful demonstration of the device has potential benefits to new femtosecond-based therapies for reshaping or removing subcutaneous tissues. / text
4

Sapphire Fiber Based Sensing Technologies for High Temperature Applications

Wang, Jiajun 11 March 2011 (has links)
Sapphire fiber has been studied intensively for harsh environment sensing in the past two decades due to its supreme mechanical, physical and optical properties. It is by far the most reported and likely the best optical fiber based sensing technology for sensing applications in temperature beyond 1000°C. Several sensing schemes have been proposed and studied to date including sapphire fiber extrinsic and intrinsic Fabry-Perot interferometers, fiber Bragg gratings and long period gratings inscribed in sapphire fibers. Lacking the cladding, sapphire fiber is highly multi-moded which renders sapphire fiber based sensor fabrication much more difficult than those based on silica fibers. Among all the reported work on sapphire fiber sensing, the vast majority is for single point temperature measurement. In this work, different sensing schemes are proposed to enhance the capability of the sapphire fiber based sensing technology. For the single point sensing, a miniaturized sapphire fiber temperature sensor for embedded sensing applications was proposed and studied. The sensors are no more than 75 µm in diameter and are ideal for non-invasive embedded sensing applications. Unlike existing sapphire fiber sensors, the thin film sensors are batch-fabrication oriented and thus have a potential to permit mass production with low cost. In addition to single point sensors, multiplexed sapphire fiber sensing systems are investigated for the first time. Two multiplexed sensing solutions, named frequency-multiplexing and spatial-multiplexing, are proposed and studied to achieve multiplexed sensing based on sapphire fibers. / Ph. D.
5

Sapphire Based Fiber-Optic Sensing for Extreme High Temperatures

Yu, Guo 13 June 2011 (has links)
Temperature sensing is one of the most common and needed sensing technique, especially in harsh environment like a coal gasifier or an airplane engine. Single crystal sapphire has been studied in the last two decades as a candidate for harsh environment sensing task, due to its excellent mechanical and optical properties under extreme high temperature (over 1000°C). In this research, a sapphire wafer based Fabry-Perot (FP) interferometer sensor has been proposed, whose functional temperature measurement can go beyond 1600°C. The size of the sensors can be limited to a 2cm-length tube, with 2mm outer diameter, which is suitable for a wide range of harsh environment applications. The sensors have shown linear sensing response during 20~1200°C temperature calibration, with high sensitivity and resolution, and strong robustness, which are ready for the field test in real-world harsh environment. / Master of Science
6

Sapphire Fiber-based Distributed High-temperature Sensing System

Liu, Bo 13 October 2016 (has links)
From the monitoring of deep ocean conditions to the imaging and exploration of the vast universe, optical sensors are playing a unique, critical role in all areas of scientific research. Optical fiber sensors, in particular, are not only widely used in daily life such as for medical inspection, structural health monitoring, and environmental surveillance, but also in high-tech, high-security applications such as missile guidance or monitoring of aircraft engines and structures. Measurements of physical parameters are required in harsh environments including high pressure, high temperature, highly electromagnetically-active and corrosive conditions. A typical example is fossil fuel-based power plants. Unfortunately, current optical fiber sensors for high-temperature monitoring can work only for single point measurement, as traditional fully-distributed temperature sensing techniques are restricted for temperatures below 800°C due to the limitation of the fragile character of silica fiber under high temperature. In this research, a first-of-its-kind technology was developed which pushed the limits of fully distributed temperature sensing (DTS) in harsh environments by exploring the feasibility of DTS in optical sapphire waveguides. An all sapphire fiber-based Raman DTS system was demonstrated in a 3-meters long sapphire fiber up to a temperature of 1400°C with a spatial resolution of 16.4cm and a standard deviation of a few degrees Celsius. In this dissertation, the design, fabrication, and testing of the sapphire fiber-based Raman DTS system are discussed in detail. The plan and direction for future work are also suggested with an aim for commercialization. / Ph. D. / This project studied the temperature dependence of Raman scattering characteristics in the single-crystal sapphire fiber. Based on these results, we designed and implemented a sapphire fiber-based fully distributed temperature sensing system using a high-power pulsed-laser. Our preliminary results show excellent and consistent temperature resolution from room temperature up to 1400 ºC. To our best knowledge, this is the first demonstration of a sapphire fiber-based distributed temperature sensing of any kind. These sensors are suitable for coal gasifiers in which the environment is corrosive, for aerospace engines and turbines requiring compact sensing elements and boilers with high-pressure environments.