• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 11
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 68
  • 35
  • 18
  • 16
  • 11
  • 11
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Cost and Area Comparison Per Student of the Public Elementary Schools in Texas based on the Project Delivery Systems

Goyal Rakesh, Sheetal 16 December 2013 (has links)
It has been shown that there exists a correlation between the cost of construction of elementary schools and the project delivery systems. Previous research showed that Competitive Sealed proposal contract method of construction is $4000 cheaper than the Construction Manager at Risk method of construction per student for elementary school construction in Texas. This research investigates the elements causing construction cost variation in elementary schools of Texas by comparing and contrasting the two forms of contract documents, CSP and CMR. Two schools were selected for the study, although the schools are technically in different regions of Texas, the geological record suggests that there is not much difference in the techniques used for foundation construction and hence a reasonable comparison is possible. A comparison was completed of the contract documents for two elementary schools. School A was built using CSP and School B using CMR. The two schools were built for about $13000 per student in line with A. N. Reinisch’s findings for CSP contracts in Texas, but not CMR average costs. The two ISD’s who supplied the documents were clearly concerned at cost control and appear to have managed this process. The earlier findings of a cost difference between CSP and CMR are not overturned by this study. Future studies involving a greater number of schools and the development of a central database are recommended.
12

Analysis of the Texas A&M University System's Construction Project Delivery Method Performance: CMAR and CSP

Neidert, Andrew 2012 August 1900 (has links)
In recent decades, the use of construction manager-at-risk (CMAR) has surged as an innovative construction project delivery method in comparison to traditional competitive bid procurement methods. The conceptual pros and cons of the method are widely accepted throughout the construction industry; however, very little quantitative research exists validating such beliefs. The study presented in this technical paper empirically compares the performance of CMAR to that of the more traditional method of competitive sealed proposal (CSP) in the construction of higher educational facilities. In a study of 33 projects constructed by The Texas A&M University System, 19 procured using CMAR and 14 procured using CSP, observed results show a reduction in schedule growth and change order quantity when using CMAR over CSP. However, additional results show that CSP is more apt to result in decreased project and construction costs than CMAR. Business practices of The Texas A&M University System, statistical significance testing of research data, and practical applications of research findings are included.
13

Estudo e levantamento de parâmetros para montagem de um laboratório de produção de fontes radioativas utilizadas na verificação de equipamentos / Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipments

Érica Gauglitz 29 March 2010 (has links)
Este trabalho apresenta o levantamento de parâmetros para implementação adequada e segura de pisos, portas, janelas, bancadas, capelas entre outros, de um laboratório radioquímico. A disposição de cada item segue orientações de guias, normas nacionais da Comissão Nacional de Energia Nuclear (CNEN) e internacional da Agencia Internacional de Energia Atômica (IAEA), com objetivo de garantir a proteção radiológica do trabalhador e do ambiente. A disposição adequada dos itens do laboratório radioquímico, garante a qualidade e segurança na produção de fontes radioativas seladas de 57Co 137Cs e 133Ba com atividades 185, 9.3 e 5.4 MBq respectivamente. Estas fontes são utilizadas na verificação de medidores de atividade, equipamento que todo Centro de Medicina Nuclear deve ter disponível segundo recomendações da norma CNEN-NN-3.05 Requisitos de Radioproteção e Segurança para Serviços de Medicina Nuclear para verificação da atividade de radiofármacos que serão administrados nos pacientes para fins de diagnóstico e terapia. Um medidor de atividade fora adquirido pelo laboratório de produção de fontes, com o qual foram realizados os testes de precisão, exatidão, reprodutibilidade e linearidade, que devem apresentar resultados dentro dos limites estabelecidos na norma CNEN-NN-3.05. / This paper presents a survey of parameters for the proper and safe flooring, doors, windows, fume hoods and others, in a radiochemical laboratory. The layout of each item follows guidelines and national standards of the National Commission of Nuclear Energy (CNEN) and the International Atomic Energy Agency (IAEA), aiming to ensure the radiological protection of workers and environment. The adequate items arrangement in the radiochemical laboratory ensures quality and safety in the production of 57Co 137Cs and 133Ba radioactive sealed sources, with activities 185, 9.3 and 5.4 MBq, respectively. These sources are used to verify meter activity equipment and should be available throughout the Nuclear Medicine Center, following the recommendations of CNEN-NN-3.05 standard \"Requirements for Radiation Protection and Safety Services for Nuclear Medicine\", to verify the activity of radiopharmaceuticals that are administered in patients, for diagnosis and therapy.
14

Desenvolvimento de metodologia para a caracterizacao de fontes radioativas seladas / Methodology development for sealed radioactive sources characterization

FERREIRA, ROBSON de J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:44Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
15

Estudo e desenvolvimento de uma semente de irídio-192 para aplicação em câncer oftálmico / Study and development of an iridium-192 seed for use in opthalmic cancer

MATTOS, FABIO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:32Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
16

Estudo da migração de radionuclídeos em depósito para fontes seladas tipo poço tubular / Study of radionuclide migration in repository type tubular well for sealed souces deposition

SABBAG, MAURICIO G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:13Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:33Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
17

Desenvolvimento de um sistema fonte-detector de radiacao para perfilagem gama em colunas de fracionamento de petroleo

VASQUEZ SALVADOR, PABLO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:52Z (GMT). No. of bitstreams: 1 09668.pdf: 6341914 bytes, checksum: 8514c212809df88b758a80f7ad2d2fd8 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
18

Estudo e desenvolvimento de um sistema de soldagem a laser Nd:YAG para produção de sementes de iodo-125 utilizadas em braquiterapia / Study and developmenty of an Nd:YAG welding system for the production of iodine-125 used in brachytherapy

FEHER, ANSELMO 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T12:35:45Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T12:35:45Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
19

Desenvolvimento de metodologia para a caracterizacao de fontes radioativas seladas / Methodology development for sealed radioactive sources characterization

FERREIRA, ROBSON de J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:44Z (GMT). No. of bitstreams: 0 / Fontes radioativas seladas são largamente empregadas no mundo. A Agência Internacional de Energia Atômica AIEA estima em dezenas de milhões de fontes radioativas no mundo. No Brasil, este número é próximo de 500 mil unidades, considerando-se as fontes de pára-raios e detectores de fumaça. Uma fonte selada pode tornar-se desnecessária, seja devido ao seu decaimento ou outro motivo, sendo classificada como fontes radioativas seladas fora de uso (FRS). No Brasil, a maioria das FRS é considerada rejeito radioativo e são encaminhadas a um dos institutos da CNEN. Sem uma estratégia definida para a deposição das FRS, estas são armazenadas aguardando uma solução. A Gerência de Rejeitos Radioativos - GRR do IPEN-CNEN/SP é o principal centro de recepção desse material e até meados de 2010 havia recebido cerca de 14.000 fontes. O processo proposto para a gestão dessas FRS consiste em retirá-las de suas blindagens originais e transferi-las a outra blindagem, projetada para esse fim. As operações de transferência são realizadas em uma cela quente, garantindo a segurança radiológica. Uma das exigências da CNEN é que todas as fontes seladas sejam caracterizadas. No processo estudado, a avaliação da atividade de cada fonte será feita utilizando-se um detector, do tipo câmara de ionização tipo poço. O presente trabalho tem por objetivo desenvolver uma metodologia para aferir ou determinar a atividade de FRS armazenadas na GRR de acordo com sua geometria e determinar suas incertezas. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
20

Estudo e desenvolvimento de uma semente de irídio-192 para aplicação em câncer oftálmico / Study and development of an iridium-192 seed for use in opthalmic cancer

MATTOS, FABIO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:32Z (GMT). No. of bitstreams: 0 / Mesmo não estando entre os casos de câncer com maior incidência, os tumores oculares têm acometido a população brasileira. O Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), juntamente à Escola Paulista de Medicina (UNIFESP), criou um projeto que visa o desenvolvimento e implementação de um tratamento de câncer oftálmico alternativo que consiste na utilização de sementes de irídio-192 em braquiterapia. O Projeto surgiu pelo motivo da Escola Paulista tratar muitos casos oncológicos no âmbito do Sistema Único de Saúde (SUS) e pela experiência em pesquisas de fontes radioativas seladas do grupo de braquiterapia do IPEN. A metodologia foi desenvolvida a partir da infraestrutura disponível e pela experiência dos pesquisadores. O protótipo desenvolvido da semente se apresenta com um núcleo (irídio em liga de irídio-platina) de 3,0mm de comprimento selado por uma cápsula de titânio de 0,8mm de diâmetro externo, 0,05mm de espessura de parede e 4,5mm de comprimento. Nenhum estudo sobre a confecção destas sementes foi encontrado em literatura disponível. Criou-se uma metodologia que envolveu: caracterização do fio, criação do dispositivo para ativação neutrônica dos núcleos e testes de estanqueidade da fonte produzida. A análise dos resultados comprovaram a viabilidade do método. Como sugestão para trabalhos futuros, estudos quanto à metrologia e dosimetria destas fontes e aprimoramento da metodologia devem ser realizados, para uma futura implementação em caráter nacional. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.3722 seconds