• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Volatile Organic Compounds and Antioxidants in Olive Oil: Their Analysis by Selected Ion Flow Tube Mass Spectrometry

Davis, Brett Murray January 2007 (has links)
The application of Selected Ion Flow Tube Mass Spectrometry (SIFT MS) to the analysis of olive oil shows several distinct advantages over more conventional analysis techniques. The two areas described in this thesis examining olive oil quality are the analysis of Volatile Organic Compounds (VOCs) and the assessment of antioxidant activity. VOCs are responsible for the aroma and much of the taste of olive oil, while antioxidants afford some protection from harmful reactions involving radical species inside the body by scavenging radicals when olive oil is ingested. The VOCs of olive oil are used by sensory panel judges to classify oils by their degree of suitability for human consumption. The major parameters used for this evaluation are the strengths of any defects and the degree of fruitiness. A defect is an indication of an undesired process which has occurred in the oil, while fruitiness is a fragile attribute which denotes a good quality oil and is easily masked by defects. SIFT MS was used to measure the strengths of the olive oil defects rancid, winey, musty, fusty and muddy. Great potential was demonstrated for all defects except musty and the concentrations of VOCs in olive oil head space were correlated with the peroxide value, a measure of the degree of oil oxidation. A study aimed at correlating the strength of the fruitiness attribute as determined by a sensory panel with the concentrations of VOCs in olive oil head space was unsuccessful. The SIFT MS Total Oxyradical Scavenging Capacity (TOSC) assay was used to measure olive oil antioxidants. This assay measures all antioxidants in oil, not only those removed by extraction with a solvent, as it is conducted in an emulsion. SIFT MS TOSC assay results were found to correlate well with those of the widely used Folin Ciocalteu assay and the total concentration of phenolic compounds present in olive oil. Discrepancies between the two assays were most likely due to hydrophobic antioxidants which are measured by the SIFT MS TOSC assay but not the other tests.
2

Volatile Organic Compounds and Antioxidants in Olive Oil: Their Analysis by Selected Ion Flow Tube Mass Spectrometry

Davis, Brett Murray January 2007 (has links)
The application of Selected Ion Flow Tube Mass Spectrometry (SIFT MS) to the analysis of olive oil shows several distinct advantages over more conventional analysis techniques. The two areas described in this thesis examining olive oil quality are the analysis of Volatile Organic Compounds (VOCs) and the assessment of antioxidant activity. VOCs are responsible for the aroma and much of the taste of olive oil, while antioxidants afford some protection from harmful reactions involving radical species inside the body by scavenging radicals when olive oil is ingested. The VOCs of olive oil are used by sensory panel judges to classify oils by their degree of suitability for human consumption. The major parameters used for this evaluation are the strengths of any defects and the degree of fruitiness. A defect is an indication of an undesired process which has occurred in the oil, while fruitiness is a fragile attribute which denotes a good quality oil and is easily masked by defects. SIFT MS was used to measure the strengths of the olive oil defects rancid, winey, musty, fusty and muddy. Great potential was demonstrated for all defects except musty and the concentrations of VOCs in olive oil head space were correlated with the peroxide value, a measure of the degree of oil oxidation. A study aimed at correlating the strength of the fruitiness attribute as determined by a sensory panel with the concentrations of VOCs in olive oil head space was unsuccessful. The SIFT MS Total Oxyradical Scavenging Capacity (TOSC) assay was used to measure olive oil antioxidants. This assay measures all antioxidants in oil, not only those removed by extraction with a solvent, as it is conducted in an emulsion. SIFT MS TOSC assay results were found to correlate well with those of the widely used Folin Ciocalteu assay and the total concentration of phenolic compounds present in olive oil. Discrepancies between the two assays were most likely due to hydrophobic antioxidants which are measured by the SIFT MS TOSC assay but not the other tests.
3

Nové metody hmotnostní spektrometrie pro stopovou analýzu látek v lidském dechu. / New mass spectrometric methods for trace gas analysis of human breath.

Brůhová Michalčíková, Regina January 2019 (has links)
This dissertation thesis summarizes results of experiments that have been carried out during my PhD studies related to the new mass spectrometric methods for trace gas analysis of human breath. The thesis is divided into the theoretical and experimental part. The chapter at the beginning of this dissertation summarizes the current research in the area of breath analysis. It is describing the common breath metabolites, benefits and challenges of the method for therapeutic monitoring and clinical diagnosis and current applications. The next chapter of the theoretical introduction describes the techniques suitable for this area of research, with a special emphasis on mass-spectrometric techniques (in particular the selected ion flow tube mass spectrometry, SIFT-MS, method that allows accurate quantification of trace gases and vapours in humid air/human breath). All these parts are elaborated via the scientific literature review. The following chapters are then directly related to my own research and describes the conducted experiment, including the results obtained. This experimental part "Results and Discussion" is divided to the individual subsections, which are conceived as the commentaries to the enclosed research papers published in peer reviewed journals. The first is the detailed step by step...
4

A FUNDAMENTAL AND APPLIED APPROACH TO SELECTED ION FLOW TUBE-MASS SPECTROMETRIC STUDY OF VOLATILE ORGANIC COMPOUNDS IN SWISS-TYPE CHEESES

Castada, Hardy Zingalaoa 29 December 2014 (has links)
No description available.
5

Kinetics of volatile generation during coffee roasting and analysis using Selected Ion Flow Tube-Mass Spectrometry

Krishnaswamy, Sangeetha 23 June 2017 (has links)
No description available.

Page generated in 0.1291 seconds