• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 1
  • 1
  • Tagged with
  • 14
  • 14
  • 14
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Case Study Analysis of Parameter Effects within the Nitrification and Denitrification Processes of Rendering Wastewater using Data Mining Techniques

Elrod, Jon L., B.S. 14 October 2013 (has links)
No description available.
2

Remoção de nitrogênio de águas residuárias com elevada concentração de nitrogênio amoniacal em reator contendo biomassa em suspensão operado em bateladas seqüenciais e sob aeração intermitente / Nitrogen removal of wastewaters with high ammonium nitrogen concentrations in reactor containing suspended biomass operated in sequential batch and under intermittent aeration

Iamamoto, Cristina Yuriko 04 August 2006 (has links)
O reator em batelada seqüencial com biomassa em suspensão foi submetido a concentrações de N-amoniacal de 125, 250 e 500 mg N/L e em condições de oxigênio dissolvido (OD) no reator de 2 mg 'O IND.2'/L, em ciclos de 2h/2h de anóxico/aeróbio. Em todas as fases, o reator foi operado como batelada alimentada. Na condição de 125 mg N/L obteve-se eficiência de remoção de 87% de N, tendo o nitrato sido o principal produto da nitrificação. Na condição de 250 mg N/L, obteve-se eficiência de remoção de N de 84%, com predominância de nitrito como principal produto da nitrificação e com ocorrência de nitrificação e desnitrificação simultânea durante os dois primeiros ciclos aeróbios. Na condição de 500 mg N/L, as condições de concentração de OD de 2 mg 'O IND.2'/L e aeração intermitente a cada 2h não foram suficientes para promover a remoção total de nitrogênio amoniacal. Foram feitas alterações: ciclos de 2h anóxico e 9h aeróbios, com concentração média de 2,8 mg 'O IND.2'/L, que resultaram em eficiências de remoção de N de 94%, com predominância de nitrito. Foram isoladas cepas desnitrificantes com similaridade de 97% para Thauera mechernichensis e Thauera sp. 27 nas condições operacionais de 125 e 250 mg N/L e de 99% para Ochrobactrum anthropi e Ochrobactrum tritici, na condição operacional de 500 mg N/L. O longo tempo de operação resultou na diminuição da população de bactérias oxidantes de nitrito, podendo ter sido uma das causas que contribuiu para que se criassem condições que levariam à nitrificação via nitrito na concentração de 500 mg N/L. O sucesso na prevenção da inibição do processo por amônia livre foi atribuído à adoção das condições operacionais do reator, que foi operado sob aeração intermitente e batelada alimentada. / The sequential batch reactor with suspended bioma was subjected to ammonium concentrations of 125, 250 and 500 mg N/L, oxygen dissolved (OD) concentrations of 2 mg 'O IND.2'/L, 2h/2h of anoxic/aerobic steps. The reactor was operated under fed-batch feeding. At the operational condition of 125 mg N/L, the mean nitrogen removal efficiency of 87% was obtained and nitrate was the main nitrification product. At operational condition of 250 mg N/L, was gotten nitrogen removal efficiencies of 84% and nitrite was the predominant form of nitrogen and simultaneous nitrification and denitrification occurred during the two first aerobic steps of the cycle. At 500 mg N/L, the operating conditions imposed to the reactor (OD concentrations of 2 mg 'O IND.2'/L and intermittent aeration of 2h) did not lead to complete nitrification during the aerated steps, thus affecting nitrogen removal. The conditions were altered increasing the aerated steps to 9 hours, with OD concentration of 2,8 mg 'O IND.2'/L, and keeping the duration of the anoxic steps in 2 hours. Under such conditions, the mean nitrogen removal efficiency attained 94% and nitrite was the predominant oxidized nitrogen specie. It was isolated denitrifiers with similarity of 97% for Thauera mechernichensis and Thauera sp. 27 at the operational conditions of 125 and 250 mg N/L and of 99% for Ochrobactrum anthropi and Ochrobactrum tritici, at operational condition of 500 mg N/L. The long term operation resulted in the decrease of nitrite oxidizers populations and this was probably the main factor contributing for the creation of conditions for the partial nitrification via nitrite to prevail during the operation at ammonium concentration of 500 mg N/L. The success in preventing free ammonia inhibition was attributed to the adoption of intermittent aeration and fed batch operation.
3

Remoção de nitrogênio de águas residuárias com elevada concentração de nitrogênio amoniacal em reator contendo biomassa em suspensão operado em bateladas seqüenciais e sob aeração intermitente / Nitrogen removal of wastewaters with high ammonium nitrogen concentrations in reactor containing suspended biomass operated in sequential batch and under intermittent aeration

Cristina Yuriko Iamamoto 04 August 2006 (has links)
O reator em batelada seqüencial com biomassa em suspensão foi submetido a concentrações de N-amoniacal de 125, 250 e 500 mg N/L e em condições de oxigênio dissolvido (OD) no reator de 2 mg 'O IND.2'/L, em ciclos de 2h/2h de anóxico/aeróbio. Em todas as fases, o reator foi operado como batelada alimentada. Na condição de 125 mg N/L obteve-se eficiência de remoção de 87% de N, tendo o nitrato sido o principal produto da nitrificação. Na condição de 250 mg N/L, obteve-se eficiência de remoção de N de 84%, com predominância de nitrito como principal produto da nitrificação e com ocorrência de nitrificação e desnitrificação simultânea durante os dois primeiros ciclos aeróbios. Na condição de 500 mg N/L, as condições de concentração de OD de 2 mg 'O IND.2'/L e aeração intermitente a cada 2h não foram suficientes para promover a remoção total de nitrogênio amoniacal. Foram feitas alterações: ciclos de 2h anóxico e 9h aeróbios, com concentração média de 2,8 mg 'O IND.2'/L, que resultaram em eficiências de remoção de N de 94%, com predominância de nitrito. Foram isoladas cepas desnitrificantes com similaridade de 97% para Thauera mechernichensis e Thauera sp. 27 nas condições operacionais de 125 e 250 mg N/L e de 99% para Ochrobactrum anthropi e Ochrobactrum tritici, na condição operacional de 500 mg N/L. O longo tempo de operação resultou na diminuição da população de bactérias oxidantes de nitrito, podendo ter sido uma das causas que contribuiu para que se criassem condições que levariam à nitrificação via nitrito na concentração de 500 mg N/L. O sucesso na prevenção da inibição do processo por amônia livre foi atribuído à adoção das condições operacionais do reator, que foi operado sob aeração intermitente e batelada alimentada. / The sequential batch reactor with suspended bioma was subjected to ammonium concentrations of 125, 250 and 500 mg N/L, oxygen dissolved (OD) concentrations of 2 mg 'O IND.2'/L, 2h/2h of anoxic/aerobic steps. The reactor was operated under fed-batch feeding. At the operational condition of 125 mg N/L, the mean nitrogen removal efficiency of 87% was obtained and nitrate was the main nitrification product. At operational condition of 250 mg N/L, was gotten nitrogen removal efficiencies of 84% and nitrite was the predominant form of nitrogen and simultaneous nitrification and denitrification occurred during the two first aerobic steps of the cycle. At 500 mg N/L, the operating conditions imposed to the reactor (OD concentrations of 2 mg 'O IND.2'/L and intermittent aeration of 2h) did not lead to complete nitrification during the aerated steps, thus affecting nitrogen removal. The conditions were altered increasing the aerated steps to 9 hours, with OD concentration of 2,8 mg 'O IND.2'/L, and keeping the duration of the anoxic steps in 2 hours. Under such conditions, the mean nitrogen removal efficiency attained 94% and nitrite was the predominant oxidized nitrogen specie. It was isolated denitrifiers with similarity of 97% for Thauera mechernichensis and Thauera sp. 27 at the operational conditions of 125 and 250 mg N/L and of 99% for Ochrobactrum anthropi and Ochrobactrum tritici, at operational condition of 500 mg N/L. The long term operation resulted in the decrease of nitrite oxidizers populations and this was probably the main factor contributing for the creation of conditions for the partial nitrification via nitrite to prevail during the operation at ammonium concentration of 500 mg N/L. The success in preventing free ammonia inhibition was attributed to the adoption of intermittent aeration and fed batch operation.
4

Reator anaeróbio em batelada seqüencial contendo biomassa imobilizada submetido a aumento de carga orgânica tratando água residuária sintética / Effects of increasing organic loading on the performance of an anaerobic sequential batch reactor containing immobilized biomass treating synthetic wastewater

Siman, Renato Ribeiro 07 April 2003 (has links)
Nesse estudo, procurou-se investigar a influência do aumento de carga orgânica em um ASBR operado a 30ºC, agitado mecanicamente e contendo microrganismos imobilizados em suporte inerte. Para tal, foi aplicado um carregamento orgânico volumétrico variando de 1,5 a 6,0 g DQO/L.dia, alimentando-se um reator construído em acrílico (5,4 L) com 2 L de água residuária sintética com concentrações de 500 a 2000 mg DQO/L com fontes de carboidrato/proteína/lipídio, em bateladas de 8 a 12 h. O sistema apresentou eficiências de remoção de material orgânico entre 73% e 88% para as condições estudadas. Entretanto, quando o reator foi alimentado com uma concentração de 2000 mg DQO/L em bateladas de 8 h, verificou-se o acúmulo de ácidos voláteis totais, refletindo na redução da eficiência de remoção de material orgânico para 55%, para amostras filtradas. Os perfis dinâmicos ao longo da batelada permitiram concluir que, para a condição com o mesmo carregamento orgânico, porém com concentrações afluentes e tempos de ciclo diferentes, a produção inicial de ácidos voláteis totais foi mais acentuada para o caso de alimentação com maior concentração. Para condições com concentrações afluentes iguais, o tempo a mais para o ciclo foi fundamental para obter-se efluente de melhor qualidade em termos de remoção de matéria orgânica. / The current study investigated the effect of increasing organic load in an ASBR operated at 30ºC with mechanical stirring and containing immobilized on inert support. Accordingly, volumetric organic loading rates ranging from 1.5 to 6.0 g COD/L.day were used by feeding an acrylic reactor (5.4 L) with 2 L of influent at concentrations of 500 to 2000 mg COD/L from wastewater containing carbohydrates, proteins and lipids in 8 and 12 h batches. Organic matter removal efficiencies between 73% and 88% were observed under the conditions investigated. However, when the reactor was fed at a concentration of 2000 mg COD/L in 8 h batches, accumulation of total volatile acids was detected, leading to a reduction in organic matter removal efficiency as low as 55% for filtered samples. The dynamic batches profiles allowed to conclude that for the same organic loading rates and different concentration influent and cycle times, the initial production of total volatile acids showed to be more pronounced for better quality effluent in terms of organic matter removal.
5

Reatores seqüenciais em batelada em sistema anaeróbio/aeróbio tratando esgoto sanitário sintético e com remoção de nutrientes / Sequential batch reactors in anaerobic/aerobic system treating synthetic domestic wastewater

Callado, Nélia Henriques 22 March 2001 (has links)
Esta tese apresenta e discute o desempenho de um sistema misto anaeróbio/aeróbio, com reatores seqüenciais em batelada, para remoção de carbono (DQO), nitrogênio e fósforo de esgoto sanitário sintético. O sistema era composto de três reatores operados em série, sendo dois anaeróbios, RSBAn1 e RSBAn2, e um aeróbio, RSBAe, com a seguinte configuração: RSBAn1/ RSBAe/RSBAn2. Os reatores foram construídos em acrílico transparente com volume total de 16,5 L e volume útil de 14,5 L. Os reatores operaram com ciclos de 24, 12, 8 e 6 horas tratando 8,0 L/batelada. Os RSBAn1 e RSBAn2 foram agitados intermitentemente recirculando-se o gás produzido e o RSBAe foi aerado/agitado continuamente. Foram utilizados substrato sintético, efluente do RSBAn1, metanol, etanol e metano como fonte externa de carbono para desnitrificação no RSBAn2, e acetato de sódio como fonte externa de carbono no RSBAe para desnitrificação e remoção biológica de fósforo. Os resultados obtidos permitiram concluir que o sistema pode apresentar efluentes com qualidade compatível aos de tratamento terciário nas condições operacionais ensaiadas. / This thesis presents and discusses the performance of an integrated anaerobic/aerobic system consisted of batch sequential reactors for the removal of carbon (DQO), nitrogen and phosphorus from synthetic wastewater simulating sewage. The system was composed of three reactors, two anaerobic (RSBAn1 e RSBAn2) and one aerobic (RSBAe) operated in series, at the following configuration RSBAnl/RSBAe/RSBAn2. The reactors were built in transparent Plexiglas with total volume of 16,5 L and useful volume of 14,5 L. They operated with cycles of 24, 12, 8 and 6 hours treating 8,0 L/batch. The RSBAn1 and RSBAn2 were agitated intermittently by recycling the gas produced, and the RSBAe was aerated/agitated continuously. Synthetic substrate, RSBAn1 effluent, methanol, ethanol and methane were used as external carbon sources for denitrification in RSBAn2. Sodium acetate was used as external carbon source in RSBAe for both denitrification and biological removal of phosphorus. The results obtained permitted to conclude that the system operated at the conditions assayed is able to produce high quality effluents, at level compatible to tertiary treatment.
6

Tratamento por coagulação-floculação de lixiviado bruto de aterro sanitário com e sem pré-tratamento biológico em reator sequencial em batelada

Gewehr, André Granzotto January 2012 (has links)
A forma de tratamento e destinação final ainda mundialmente preponderante para os resíduos sólidos urbanos é o aterro sanitário, método que gera, além de uma massa sólida residual, parcialmente estabilizada, subprodutos finais líquidos e gasosos. O efluente líquido, conhecido como lixiviado, necessita tratamento específico, devido a sua elevada nocividade ao meio ambiente, em função, principalmente, de suas elevadas concentrações de nitrogênio amoniacal e de matéria orgânica, em elevado percentual, recalcitrante. O presente trabalho avaliou em escala de bancada o tratamento, via processo físico-químico, através de coagulação-floculação, de lixiviado bruto proveniente de aterro sanitário Central de Resíduos do Recreio (operado pela Companhia Riograndense de Valorização de Resíduos), desprovido de qualquer tratamento prévio, e de lixiviado pré-tratado biologicamente em reatores sequenciais em batelada (RSB). Para o processo de coagulação-floculação foram testados os coagulantes policloreto de alumínio (PAC), cloreto férrico, sulfato férrico e tanino. Sucessivas etapas foram planejadas para a determinação de dosagem e ajuste de pH ótimos, para cada coagulante empregado, e para a verificação da influência de tempos e gradientes de misturas, bem como foi testada a aplicação de polímeros auxiliares de floculação. As variáveis resposta utilizadas para o monitoramento e a avaliação de eficiências foram a cor verdadeira, turbidez (com e sem prévia filtração), DQO, volume de lodo gerado e pH. O uso de reator sequencial em batelada objetivou nitrificação/desnitrificação convencional das elevadas concentrações de nitrogênio amoniacal e eventual oxidação de matéria carbonácea. Verificou-se que os diferentes tempos e gradientes de mistura testados, assim como a utilização de polímeros auxiliares, não produziram impactos nos resultados. Os coagulantes inorgânicos apresentaram elevadas eficiências de remoção, com destaque para o cloreto férrico, o qual na dosagem de 1102 mgFe+3/L e ajuste inicial de pH em 6,2 removeu 98% da cor verdadeira e da turbidez filtrada, 63% da DQO, 40% da DBO5, e 88% de turbidez não filtrada do lixiviado bruto. Apesar da recalcitrância de considerável fração da matéria orgânica do lixiviado, o RSB2 removeu 40% da DQO e 60% da DBO5 originais. A coagulação-floculação do efluente do RSB2 necessitou inferiores dosagens dos coagulantes em relação ao processo com lixiviado bruto. O cloreto férrico, em dosagem ótima de 826 mgFe+3/L e ajuste de pH em 6,3, removeu 95% da cor, 77% da DQO, 82% da DBO5, 94% da turbidez filtrada e 92% da turbidez não filtrada. Concluiu-se por elevada viabilidade técnica do processo de coagulação-floculação para o lixiviado com e sem pré-tratamento, a partir da otimização das condições de contorno do processo. O pré-tratamento em RSB, quando utilizado controle de pH, demonstrou grande potencial para nitrificação/desnitrificação e oxidação de significante parcela da matéria carbonácea do lixiviado bruto. / The form of treatment and disposal still prevalent worldwide for solid waste is the landfill, a method that generates, in addition to a solid mass residual partially stabilized, liquid and gas end products. The effluent liquid, known as leachate, requires specific treatment, due to its high harmfulness to the environment, due mainly to its high concentrations of ammonia nitrogen and organic matter in high percentage, recalcitrant. This study evaluated the treatment on bench scale, via physico-chemical process, by coagulation-flocculation, of raw leachate from Central de Resíduos do Recreio landfill (operated by Companhia Riograndense de Valorização de Resíduos), devoid of any previous treatment, and biologically pretreated leachate reactors in sequential batch reactors (SBR). For the process of flocculation-coagulation were tested polyaluminum chloride (PAC), ferric chloride, ferric sulfate and tannin. Successive stages were designed for determining dosage and optimum pH adjustment for each coagulant employed and for verifying the influence of times and gradients mixtures, as well as tested in the application of polymers flocculation auxiliaries. The answers used for parametric monitoring and evaluation of efficiencies were the true color, turbidity (with and without prior filtration), COD, sludge volume and pH. The use of sequential batch reactor aimed conventional nitrification/denitrification of the high concentrations of ammonia nitrogen and eventual oxidation of carbonaceous matter. It was found that the different gradients and mixing times tested, as well as the use of auxiliary polymers, did not produce impact on the results. The inorganic coagulants showed high removal efficiencies, especially ferric chloride, which at a dose of 1102 mgFe+3/L and initial pH adjusted to 6.2, removed 98% of the true color and filtered turbidity, 63% of COD, 40% of BOD5 and 88% of unfiltered turbidity. Despite the considerable fraction of the recalcitrance of organic matter in the leachate, the SBR2 removed 40% of COD and 60% of BOD5 of the original. The coagulation-flocculation of the effluent from SBR2 required lower dosages of coagulants in relation to the similar process with raw leachate. Ferric chloride in optimum dosage of 826 mgFe+3/L and adjusting pH to 6.3, removed 95% of color, 77% of COD, 82% of BOD5, 94% of the filtered turbidity and 92% of unfiltered turbidity. It was concluded by high technical feasibility of the process of flocculation-coagulation for the leachate with and without pre-treatment, based on the optimization of the boundary conditions of the process. The pre-treatment with SBR, when pH control, demonstrated high potential for nitrification/denitrification and oxidation of a significant portion of the carbonaceous of the raw leachate.
7

Tratamento por coagulação-floculação de lixiviado bruto de aterro sanitário com e sem pré-tratamento biológico em reator sequencial em batelada

Gewehr, André Granzotto January 2012 (has links)
A forma de tratamento e destinação final ainda mundialmente preponderante para os resíduos sólidos urbanos é o aterro sanitário, método que gera, além de uma massa sólida residual, parcialmente estabilizada, subprodutos finais líquidos e gasosos. O efluente líquido, conhecido como lixiviado, necessita tratamento específico, devido a sua elevada nocividade ao meio ambiente, em função, principalmente, de suas elevadas concentrações de nitrogênio amoniacal e de matéria orgânica, em elevado percentual, recalcitrante. O presente trabalho avaliou em escala de bancada o tratamento, via processo físico-químico, através de coagulação-floculação, de lixiviado bruto proveniente de aterro sanitário Central de Resíduos do Recreio (operado pela Companhia Riograndense de Valorização de Resíduos), desprovido de qualquer tratamento prévio, e de lixiviado pré-tratado biologicamente em reatores sequenciais em batelada (RSB). Para o processo de coagulação-floculação foram testados os coagulantes policloreto de alumínio (PAC), cloreto férrico, sulfato férrico e tanino. Sucessivas etapas foram planejadas para a determinação de dosagem e ajuste de pH ótimos, para cada coagulante empregado, e para a verificação da influência de tempos e gradientes de misturas, bem como foi testada a aplicação de polímeros auxiliares de floculação. As variáveis resposta utilizadas para o monitoramento e a avaliação de eficiências foram a cor verdadeira, turbidez (com e sem prévia filtração), DQO, volume de lodo gerado e pH. O uso de reator sequencial em batelada objetivou nitrificação/desnitrificação convencional das elevadas concentrações de nitrogênio amoniacal e eventual oxidação de matéria carbonácea. Verificou-se que os diferentes tempos e gradientes de mistura testados, assim como a utilização de polímeros auxiliares, não produziram impactos nos resultados. Os coagulantes inorgânicos apresentaram elevadas eficiências de remoção, com destaque para o cloreto férrico, o qual na dosagem de 1102 mgFe+3/L e ajuste inicial de pH em 6,2 removeu 98% da cor verdadeira e da turbidez filtrada, 63% da DQO, 40% da DBO5, e 88% de turbidez não filtrada do lixiviado bruto. Apesar da recalcitrância de considerável fração da matéria orgânica do lixiviado, o RSB2 removeu 40% da DQO e 60% da DBO5 originais. A coagulação-floculação do efluente do RSB2 necessitou inferiores dosagens dos coagulantes em relação ao processo com lixiviado bruto. O cloreto férrico, em dosagem ótima de 826 mgFe+3/L e ajuste de pH em 6,3, removeu 95% da cor, 77% da DQO, 82% da DBO5, 94% da turbidez filtrada e 92% da turbidez não filtrada. Concluiu-se por elevada viabilidade técnica do processo de coagulação-floculação para o lixiviado com e sem pré-tratamento, a partir da otimização das condições de contorno do processo. O pré-tratamento em RSB, quando utilizado controle de pH, demonstrou grande potencial para nitrificação/desnitrificação e oxidação de significante parcela da matéria carbonácea do lixiviado bruto. / The form of treatment and disposal still prevalent worldwide for solid waste is the landfill, a method that generates, in addition to a solid mass residual partially stabilized, liquid and gas end products. The effluent liquid, known as leachate, requires specific treatment, due to its high harmfulness to the environment, due mainly to its high concentrations of ammonia nitrogen and organic matter in high percentage, recalcitrant. This study evaluated the treatment on bench scale, via physico-chemical process, by coagulation-flocculation, of raw leachate from Central de Resíduos do Recreio landfill (operated by Companhia Riograndense de Valorização de Resíduos), devoid of any previous treatment, and biologically pretreated leachate reactors in sequential batch reactors (SBR). For the process of flocculation-coagulation were tested polyaluminum chloride (PAC), ferric chloride, ferric sulfate and tannin. Successive stages were designed for determining dosage and optimum pH adjustment for each coagulant employed and for verifying the influence of times and gradients mixtures, as well as tested in the application of polymers flocculation auxiliaries. The answers used for parametric monitoring and evaluation of efficiencies were the true color, turbidity (with and without prior filtration), COD, sludge volume and pH. The use of sequential batch reactor aimed conventional nitrification/denitrification of the high concentrations of ammonia nitrogen and eventual oxidation of carbonaceous matter. It was found that the different gradients and mixing times tested, as well as the use of auxiliary polymers, did not produce impact on the results. The inorganic coagulants showed high removal efficiencies, especially ferric chloride, which at a dose of 1102 mgFe+3/L and initial pH adjusted to 6.2, removed 98% of the true color and filtered turbidity, 63% of COD, 40% of BOD5 and 88% of unfiltered turbidity. Despite the considerable fraction of the recalcitrance of organic matter in the leachate, the SBR2 removed 40% of COD and 60% of BOD5 of the original. The coagulation-flocculation of the effluent from SBR2 required lower dosages of coagulants in relation to the similar process with raw leachate. Ferric chloride in optimum dosage of 826 mgFe+3/L and adjusting pH to 6.3, removed 95% of color, 77% of COD, 82% of BOD5, 94% of the filtered turbidity and 92% of unfiltered turbidity. It was concluded by high technical feasibility of the process of flocculation-coagulation for the leachate with and without pre-treatment, based on the optimization of the boundary conditions of the process. The pre-treatment with SBR, when pH control, demonstrated high potential for nitrification/denitrification and oxidation of a significant portion of the carbonaceous of the raw leachate.
8

Tratamento por coagulação-floculação de lixiviado bruto de aterro sanitário com e sem pré-tratamento biológico em reator sequencial em batelada

Gewehr, André Granzotto January 2012 (has links)
A forma de tratamento e destinação final ainda mundialmente preponderante para os resíduos sólidos urbanos é o aterro sanitário, método que gera, além de uma massa sólida residual, parcialmente estabilizada, subprodutos finais líquidos e gasosos. O efluente líquido, conhecido como lixiviado, necessita tratamento específico, devido a sua elevada nocividade ao meio ambiente, em função, principalmente, de suas elevadas concentrações de nitrogênio amoniacal e de matéria orgânica, em elevado percentual, recalcitrante. O presente trabalho avaliou em escala de bancada o tratamento, via processo físico-químico, através de coagulação-floculação, de lixiviado bruto proveniente de aterro sanitário Central de Resíduos do Recreio (operado pela Companhia Riograndense de Valorização de Resíduos), desprovido de qualquer tratamento prévio, e de lixiviado pré-tratado biologicamente em reatores sequenciais em batelada (RSB). Para o processo de coagulação-floculação foram testados os coagulantes policloreto de alumínio (PAC), cloreto férrico, sulfato férrico e tanino. Sucessivas etapas foram planejadas para a determinação de dosagem e ajuste de pH ótimos, para cada coagulante empregado, e para a verificação da influência de tempos e gradientes de misturas, bem como foi testada a aplicação de polímeros auxiliares de floculação. As variáveis resposta utilizadas para o monitoramento e a avaliação de eficiências foram a cor verdadeira, turbidez (com e sem prévia filtração), DQO, volume de lodo gerado e pH. O uso de reator sequencial em batelada objetivou nitrificação/desnitrificação convencional das elevadas concentrações de nitrogênio amoniacal e eventual oxidação de matéria carbonácea. Verificou-se que os diferentes tempos e gradientes de mistura testados, assim como a utilização de polímeros auxiliares, não produziram impactos nos resultados. Os coagulantes inorgânicos apresentaram elevadas eficiências de remoção, com destaque para o cloreto férrico, o qual na dosagem de 1102 mgFe+3/L e ajuste inicial de pH em 6,2 removeu 98% da cor verdadeira e da turbidez filtrada, 63% da DQO, 40% da DBO5, e 88% de turbidez não filtrada do lixiviado bruto. Apesar da recalcitrância de considerável fração da matéria orgânica do lixiviado, o RSB2 removeu 40% da DQO e 60% da DBO5 originais. A coagulação-floculação do efluente do RSB2 necessitou inferiores dosagens dos coagulantes em relação ao processo com lixiviado bruto. O cloreto férrico, em dosagem ótima de 826 mgFe+3/L e ajuste de pH em 6,3, removeu 95% da cor, 77% da DQO, 82% da DBO5, 94% da turbidez filtrada e 92% da turbidez não filtrada. Concluiu-se por elevada viabilidade técnica do processo de coagulação-floculação para o lixiviado com e sem pré-tratamento, a partir da otimização das condições de contorno do processo. O pré-tratamento em RSB, quando utilizado controle de pH, demonstrou grande potencial para nitrificação/desnitrificação e oxidação de significante parcela da matéria carbonácea do lixiviado bruto. / The form of treatment and disposal still prevalent worldwide for solid waste is the landfill, a method that generates, in addition to a solid mass residual partially stabilized, liquid and gas end products. The effluent liquid, known as leachate, requires specific treatment, due to its high harmfulness to the environment, due mainly to its high concentrations of ammonia nitrogen and organic matter in high percentage, recalcitrant. This study evaluated the treatment on bench scale, via physico-chemical process, by coagulation-flocculation, of raw leachate from Central de Resíduos do Recreio landfill (operated by Companhia Riograndense de Valorização de Resíduos), devoid of any previous treatment, and biologically pretreated leachate reactors in sequential batch reactors (SBR). For the process of flocculation-coagulation were tested polyaluminum chloride (PAC), ferric chloride, ferric sulfate and tannin. Successive stages were designed for determining dosage and optimum pH adjustment for each coagulant employed and for verifying the influence of times and gradients mixtures, as well as tested in the application of polymers flocculation auxiliaries. The answers used for parametric monitoring and evaluation of efficiencies were the true color, turbidity (with and without prior filtration), COD, sludge volume and pH. The use of sequential batch reactor aimed conventional nitrification/denitrification of the high concentrations of ammonia nitrogen and eventual oxidation of carbonaceous matter. It was found that the different gradients and mixing times tested, as well as the use of auxiliary polymers, did not produce impact on the results. The inorganic coagulants showed high removal efficiencies, especially ferric chloride, which at a dose of 1102 mgFe+3/L and initial pH adjusted to 6.2, removed 98% of the true color and filtered turbidity, 63% of COD, 40% of BOD5 and 88% of unfiltered turbidity. Despite the considerable fraction of the recalcitrance of organic matter in the leachate, the SBR2 removed 40% of COD and 60% of BOD5 of the original. The coagulation-flocculation of the effluent from SBR2 required lower dosages of coagulants in relation to the similar process with raw leachate. Ferric chloride in optimum dosage of 826 mgFe+3/L and adjusting pH to 6.3, removed 95% of color, 77% of COD, 82% of BOD5, 94% of the filtered turbidity and 92% of unfiltered turbidity. It was concluded by high technical feasibility of the process of flocculation-coagulation for the leachate with and without pre-treatment, based on the optimization of the boundary conditions of the process. The pre-treatment with SBR, when pH control, demonstrated high potential for nitrification/denitrification and oxidation of a significant portion of the carbonaceous of the raw leachate.
9

Reator anaeróbio em batelada seqüencial contendo biomassa imobilizada submetido a aumento de carga orgânica tratando água residuária sintética / Effects of increasing organic loading on the performance of an anaerobic sequential batch reactor containing immobilized biomass treating synthetic wastewater

Renato Ribeiro Siman 07 April 2003 (has links)
Nesse estudo, procurou-se investigar a influência do aumento de carga orgânica em um ASBR operado a 30ºC, agitado mecanicamente e contendo microrganismos imobilizados em suporte inerte. Para tal, foi aplicado um carregamento orgânico volumétrico variando de 1,5 a 6,0 g DQO/L.dia, alimentando-se um reator construído em acrílico (5,4 L) com 2 L de água residuária sintética com concentrações de 500 a 2000 mg DQO/L com fontes de carboidrato/proteína/lipídio, em bateladas de 8 a 12 h. O sistema apresentou eficiências de remoção de material orgânico entre 73% e 88% para as condições estudadas. Entretanto, quando o reator foi alimentado com uma concentração de 2000 mg DQO/L em bateladas de 8 h, verificou-se o acúmulo de ácidos voláteis totais, refletindo na redução da eficiência de remoção de material orgânico para 55%, para amostras filtradas. Os perfis dinâmicos ao longo da batelada permitiram concluir que, para a condição com o mesmo carregamento orgânico, porém com concentrações afluentes e tempos de ciclo diferentes, a produção inicial de ácidos voláteis totais foi mais acentuada para o caso de alimentação com maior concentração. Para condições com concentrações afluentes iguais, o tempo a mais para o ciclo foi fundamental para obter-se efluente de melhor qualidade em termos de remoção de matéria orgânica. / The current study investigated the effect of increasing organic load in an ASBR operated at 30ºC with mechanical stirring and containing immobilized on inert support. Accordingly, volumetric organic loading rates ranging from 1.5 to 6.0 g COD/L.day were used by feeding an acrylic reactor (5.4 L) with 2 L of influent at concentrations of 500 to 2000 mg COD/L from wastewater containing carbohydrates, proteins and lipids in 8 and 12 h batches. Organic matter removal efficiencies between 73% and 88% were observed under the conditions investigated. However, when the reactor was fed at a concentration of 2000 mg COD/L in 8 h batches, accumulation of total volatile acids was detected, leading to a reduction in organic matter removal efficiency as low as 55% for filtered samples. The dynamic batches profiles allowed to conclude that for the same organic loading rates and different concentration influent and cycle times, the initial production of total volatile acids showed to be more pronounced for better quality effluent in terms of organic matter removal.
10

Reatores seqüenciais em batelada em sistema anaeróbio/aeróbio tratando esgoto sanitário sintético e com remoção de nutrientes / Sequential batch reactors in anaerobic/aerobic system treating synthetic domestic wastewater

Nélia Henriques Callado 22 March 2001 (has links)
Esta tese apresenta e discute o desempenho de um sistema misto anaeróbio/aeróbio, com reatores seqüenciais em batelada, para remoção de carbono (DQO), nitrogênio e fósforo de esgoto sanitário sintético. O sistema era composto de três reatores operados em série, sendo dois anaeróbios, RSBAn1 e RSBAn2, e um aeróbio, RSBAe, com a seguinte configuração: RSBAn1/ RSBAe/RSBAn2. Os reatores foram construídos em acrílico transparente com volume total de 16,5 L e volume útil de 14,5 L. Os reatores operaram com ciclos de 24, 12, 8 e 6 horas tratando 8,0 L/batelada. Os RSBAn1 e RSBAn2 foram agitados intermitentemente recirculando-se o gás produzido e o RSBAe foi aerado/agitado continuamente. Foram utilizados substrato sintético, efluente do RSBAn1, metanol, etanol e metano como fonte externa de carbono para desnitrificação no RSBAn2, e acetato de sódio como fonte externa de carbono no RSBAe para desnitrificação e remoção biológica de fósforo. Os resultados obtidos permitiram concluir que o sistema pode apresentar efluentes com qualidade compatível aos de tratamento terciário nas condições operacionais ensaiadas. / This thesis presents and discusses the performance of an integrated anaerobic/aerobic system consisted of batch sequential reactors for the removal of carbon (DQO), nitrogen and phosphorus from synthetic wastewater simulating sewage. The system was composed of three reactors, two anaerobic (RSBAn1 e RSBAn2) and one aerobic (RSBAe) operated in series, at the following configuration RSBAnl/RSBAe/RSBAn2. The reactors were built in transparent Plexiglas with total volume of 16,5 L and useful volume of 14,5 L. They operated with cycles of 24, 12, 8 and 6 hours treating 8,0 L/batch. The RSBAn1 and RSBAn2 were agitated intermittently by recycling the gas produced, and the RSBAe was aerated/agitated continuously. Synthetic substrate, RSBAn1 effluent, methanol, ethanol and methane were used as external carbon sources for denitrification in RSBAn2. Sodium acetate was used as external carbon source in RSBAe for both denitrification and biological removal of phosphorus. The results obtained permitted to conclude that the system operated at the conditions assayed is able to produce high quality effluents, at level compatible to tertiary treatment.

Page generated in 0.3117 seconds