Spelling suggestions: "subject:"shear key""
1 |
Reflective cracking of shear keys in multi-beam bridgesSharpe, Graeme Peter 02 June 2009 (has links)
Multi-beam bridges made from precast concrete box girders are one of the most
common bridge types used in the United States. One problem that affects these bridges
is the development of longitudinal or reflective cracks on the road surface because of
failure of the shear keys. Some states have attempted to correct this problem by
redesigning the shear key or adding post-tensioning, but the problem persists in many
new bridges.
The purpose of this study is to investigate why these shear key failures are
occurring. This project studies two types of box girder designs, the common
Precast/Prestressed Concrete Institute (PCI) box girder bridges and the Texas
Department of Tranportation (TxDOT) box girder bridge. In the past, reflective
cracking has occurred in bridges of both types.
The analysis procedure involves finite element analyses of bridge models with
realistic support and loading conditions, and comparing the PCI and TxDOT bridges.
The results indicate that both PCI and TxDOT box girder have sufficient strength to
resist cracking from vehicular loads, but uneven temperature changes and shrinkage strains cause high tensile stresses in the shear key regions and lead to reflective cracking.
The analyses showed the highest stresses were often times near the supports, rather than
at midspan.
Past studies have proposed using larger composite deck slabs, transverse posttensioning,
or full-depth shear keys to prevent shear key failure. Composite slabs were
the most effective way to reduce high stresses in shear keys, and were effective for all
loading cases considered. Post-tensioning and full-depth keys also showed a reduction
in shear key stresses, but were less effective.
|
2 |
Estudo de cálice de fundação com ênfase nos esforços nas paredes transversais do colarinho / Study of the socket base foundation with emphasis on the efforts of transverse wallsNunes, Vinicius César Pereira 08 May 2009 (has links)
Este trabalho apresenta uma análise da ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado, focando os esforços nas paredes transversais do colarinho. No programa experimental foram ensaiados dois protótipos submetidos à flexão com grande excentricidade: um com interface pilar-colarinho lisa e o outro com interface rugosa por meio de chaves de cisalhamento. Foi adotado um detalhamento diferenciado para as armaduras verticais principais concentrando as mesmas próximas aos cantos, bem como foi adotada, para o colarinho, uma espessura inferior à recomendada pela literatura técnica. Com os resultados experimentais foi possível analisar a resistência dos protótipos, as deformações das armaduras e os deslocamentos das paredes. Foi realizada uma análise dos resultados experimentais com um modelo de cálculo da literatura técnica, no que diz respeito às forças resultantes nas armaduras verticais principais e nas armaduras horizontais principais situadas nas paredes transversais do colarinho, considerando duas situações distintas de comportamento para as paredes transversais: flexo-tração e tração. Em função dos resultados foi verificado que as armaduras verticais situadas próximo aos cantos contribuíram efetivamente para a resistência do protótipo com interface lisa. Comprovou-se que as paredes transversais foram submetidas a uma flexo-tração e que o modelo teórico aplicado considerando 15% de flexão e 85% de tração apresenta os melhores resultados, se comparados com os valores obtidos experimentalmente. / This research presents an analysis of socket base connections of precast concrete structures, with emphasis on the e orts of transverse walls. In the experimental program were tested two prototypes subjected to bending with great eccentricity: one with smooth interface, and other with rough interface through shear keys. It adopted a different detail for main vertical reiforcement, concentrating them around the corner, and was adopted for the socket, a thickness less than that recommended by the technical literature. Based on experimental results were performed the analysis of the strenght of prototypes, the deformations of the reinforcement, and the deflection of the walls. It was performed an analysis of experimental results with a design model of the technical literature regarding to the forces resulting in main vertical and horizontal reinforcement located on the transverse walls of socket, considering two different situations of behavior to transverse walls: bending-tension and tension. Analyzing the results, it was verified that the vertical reinforcement located near the corners effectively contributed to the strength of the prototype with smooth interface. It has been proved that the walls were subjected to a bending tension and that the theoretical model applied with 15% of bending and 85% of tension gives the best results, when compared with the values obtained experimentally.
|
3 |
Ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado com profundidade de embutimento reduzida / Column-foundation connection through socket of precast concrete structures with reduced depthJaguaribe Júnior, Kenneth de Borja 17 November 2005 (has links)
Este trabalho consiste na análise experimental da ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado, com profundidade de embutimento reduzida em relação a recomendada pela NBR 9062:(1985). No programa experimental, foram ensaiados dois protótipos sob ação de força com grande excentricidade, variando-se o tipo e condição de interface: um com interface lisa e outro com interface rugosa. Em ambos os modelos, procurou-se eliminar a adesão na interface da ligação para representar a situação mais adequada de projeto. Com os resultados experimentais, foi possível analisar o comportamento da cada modelo no que diz respeito as deformações nas armaduras, os deslocamentos no cálice, a configuração das fissuras ocorridas durante o ensaio e a resistência última alcançada por cada modelo. Foi apresentada também uma análise comparativa entre estes modelos e os analisados em trabalho anterior sobre o mesmo tema, sendo que nestes os cálices possuíam profundidades de embutimento recomendados pela norma brasileira. Aplicou-se também os principais modelos de projeto encontrados na literatura com o objetivo de verificar a eficácia de cada um no que diz respeito a capacidade resistente da ligação, comparando-a aos obtidos experimentalmente. Com base em todas estas análises, pôde-se concluir que com a redução da profundidade de embutimento a capacidade resistente do protótipo também diminuiu e os modelos de projeto que melhor representaram os protótipos com comprimento de embutimento maior, não forneceram bons resultados para os cálices com profundidade reduzida / This research is an experimental analysis of column-foundation connection through socket of precast concrete structures, with the reduced depth of the socket comparing to that recommended by the NBR 9062:(1985). The experimental program included two models submitted to normal load with large eccentricity, changing the type and the condition interface: one model had smooth interface and other had rough interface. At both models, it was tried to eliminate the bond on the interface to represent the more appropriate situation of design. With the experimental results, it was possible to analyze each model behavior concerning reinforcements deformation, the socket displacement, cracks configuration during the tests and the maximum strength reached by each model. A comparative analysis was made of these models with those studied at a previous research, that had a depth of the socket recommended by the brazilian normalization. The main design models found at the technical literature were also applied to verify the efficiency of each one for strength capacity of the connection, comparing the results with those obtained experimentally. Based on all analysis, it was possible to conclude that with the depth reduction of the socket, the strength capacity also reduced and the design models that better represented the sockets with the recommended depth no more represented the reduced one
|
4 |
Estudo de cálice de fundação com ênfase nos esforços nas paredes transversais do colarinho / Study of the socket base foundation with emphasis on the efforts of transverse wallsVinicius César Pereira Nunes 08 May 2009 (has links)
Este trabalho apresenta uma análise da ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado, focando os esforços nas paredes transversais do colarinho. No programa experimental foram ensaiados dois protótipos submetidos à flexão com grande excentricidade: um com interface pilar-colarinho lisa e o outro com interface rugosa por meio de chaves de cisalhamento. Foi adotado um detalhamento diferenciado para as armaduras verticais principais concentrando as mesmas próximas aos cantos, bem como foi adotada, para o colarinho, uma espessura inferior à recomendada pela literatura técnica. Com os resultados experimentais foi possível analisar a resistência dos protótipos, as deformações das armaduras e os deslocamentos das paredes. Foi realizada uma análise dos resultados experimentais com um modelo de cálculo da literatura técnica, no que diz respeito às forças resultantes nas armaduras verticais principais e nas armaduras horizontais principais situadas nas paredes transversais do colarinho, considerando duas situações distintas de comportamento para as paredes transversais: flexo-tração e tração. Em função dos resultados foi verificado que as armaduras verticais situadas próximo aos cantos contribuíram efetivamente para a resistência do protótipo com interface lisa. Comprovou-se que as paredes transversais foram submetidas a uma flexo-tração e que o modelo teórico aplicado considerando 15% de flexão e 85% de tração apresenta os melhores resultados, se comparados com os valores obtidos experimentalmente. / This research presents an analysis of socket base connections of precast concrete structures, with emphasis on the e orts of transverse walls. In the experimental program were tested two prototypes subjected to bending with great eccentricity: one with smooth interface, and other with rough interface through shear keys. It adopted a different detail for main vertical reiforcement, concentrating them around the corner, and was adopted for the socket, a thickness less than that recommended by the technical literature. Based on experimental results were performed the analysis of the strenght of prototypes, the deformations of the reinforcement, and the deflection of the walls. It was performed an analysis of experimental results with a design model of the technical literature regarding to the forces resulting in main vertical and horizontal reinforcement located on the transverse walls of socket, considering two different situations of behavior to transverse walls: bending-tension and tension. Analyzing the results, it was verified that the vertical reinforcement located near the corners effectively contributed to the strength of the prototype with smooth interface. It has been proved that the walls were subjected to a bending tension and that the theoretical model applied with 15% of bending and 85% of tension gives the best results, when compared with the values obtained experimentally.
|
5 |
Ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado com profundidade de embutimento reduzida / Column-foundation connection through socket of precast concrete structures with reduced depthKenneth de Borja Jaguaribe Júnior 17 November 2005 (has links)
Este trabalho consiste na análise experimental da ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado, com profundidade de embutimento reduzida em relação a recomendada pela NBR 9062:(1985). No programa experimental, foram ensaiados dois protótipos sob ação de força com grande excentricidade, variando-se o tipo e condição de interface: um com interface lisa e outro com interface rugosa. Em ambos os modelos, procurou-se eliminar a adesão na interface da ligação para representar a situação mais adequada de projeto. Com os resultados experimentais, foi possível analisar o comportamento da cada modelo no que diz respeito as deformações nas armaduras, os deslocamentos no cálice, a configuração das fissuras ocorridas durante o ensaio e a resistência última alcançada por cada modelo. Foi apresentada também uma análise comparativa entre estes modelos e os analisados em trabalho anterior sobre o mesmo tema, sendo que nestes os cálices possuíam profundidades de embutimento recomendados pela norma brasileira. Aplicou-se também os principais modelos de projeto encontrados na literatura com o objetivo de verificar a eficácia de cada um no que diz respeito a capacidade resistente da ligação, comparando-a aos obtidos experimentalmente. Com base em todas estas análises, pôde-se concluir que com a redução da profundidade de embutimento a capacidade resistente do protótipo também diminuiu e os modelos de projeto que melhor representaram os protótipos com comprimento de embutimento maior, não forneceram bons resultados para os cálices com profundidade reduzida / This research is an experimental analysis of column-foundation connection through socket of precast concrete structures, with the reduced depth of the socket comparing to that recommended by the NBR 9062:(1985). The experimental program included two models submitted to normal load with large eccentricity, changing the type and the condition interface: one model had smooth interface and other had rough interface. At both models, it was tried to eliminate the bond on the interface to represent the more appropriate situation of design. With the experimental results, it was possible to analyze each model behavior concerning reinforcements deformation, the socket displacement, cracks configuration during the tests and the maximum strength reached by each model. A comparative analysis was made of these models with those studied at a previous research, that had a depth of the socket recommended by the brazilian normalization. The main design models found at the technical literature were also applied to verify the efficiency of each one for strength capacity of the connection, comparing the results with those obtained experimentally. Based on all analysis, it was possible to conclude that with the depth reduction of the socket, the strength capacity also reduced and the design models that better represented the sockets with the recommended depth no more represented the reduced one
|
Page generated in 0.0616 seconds