• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 193
  • 32
  • 29
  • 26
  • 14
  • 13
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 417
  • 46
  • 42
  • 39
  • 38
  • 35
  • 33
  • 33
  • 26
  • 23
  • 22
  • 20
  • 20
  • 20
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Applications of an electronic transformer in a power distribution system

Ratanapanachote, Somnida 01 November 2005 (has links)
In electrical power distribution and power electronic applications, a transformer is an indispensable component which performs many functions. At its operating frequency (60/50 Hz), it is one of the most bulky and expensive components. The concept of the electronic transformer introduced previously has shown considerable reduction in size, weight, and volume by operating at a higher frequency. In this dissertation, the concept of the electronic transformer is further extended to the auto-connected phase-shifting type to reduce harmonics generated by nonlinear loads. It is shown that with the addition of primary side and secondary side AC/AC converters achieves phase-shifting. With the addition of converters, magnetic components are operated at a higher frequency to yield a smaller size and weight. Two types of auto-connected electronic transformer configurations are explored. In the first configuration, the secondary converter is eliminated and the output is suitable for rectifier type loads such as adjustable speed drives. In the second configuration, the secondary converter is added to obtain a sinusoidal phase-shifted AC output voltage. This approach is applicable in general applications. With the proposed approaches, the th and 7th harmonic in utility line currents, generated by two sets of nonlinear loads, are subtracted within the electronic transformer, thereby reducing the total harmonic distortion (THD) of the line current. The analysis and simulation results are presented. In the second part of the dissertation, the electronic transformer concept is applied to a telecommunication power supply (-48 VDC) system. The proposed approach consists of a matrix converter to convert the low frequency three-phase input AC utility to a high frequency AC output without a DC-link. The output of the matrix converter is then processed via a high frequency isolation transformer to produce -48 VDC. Digital control of the system ensures that the output voltage is regulated and the input currents are of high quality, devoid of low frequency harmonics and at near unity input power factor under varying load conditions. Due to the absence of DC-link electrolytic capacitors, the power density of the proposed rectifier is shown to be higher. Analysis, design example and experimental results are presented from a three-phase 208 V, 1.5 kW laboratory prototype converter.
72

Article: Reducing the electricity cost of a three-pipe water pumping system : a case study using software / White Rautenbach

Rautenbach, John White January 2004 (has links)
Efficient control is often the most cost-effective option to improve on the running cost of a Three-Pipe Water Pumping System. However, the effect of changing the control strategy (i.e. on energy consumption) is usually difficult to predict. To obtain this information more easily, a new simulation tool, QUICKcontrol, was developed. This new tool was used to investigate the energy cost savings potential in a Three-Pipe Water Pumping System. The influence of pump scheduling, dam level set points, control parameters and different combinations thereof was investigated. The simulation models were firstly verified with measurements obtained from the existing system to confirm their accuracy for realistic control retrofit simulations. With the aid of the integrated simulation tool it was possible to predict savings of R 195'000 per year with an average 3.8 MW of load shifted. / Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2005.
73

Modeling, Simulation and Optimization of Residential and Commercial Energy Systems

Bregaw, Mohamed Abdussalam 12 August 2013 (has links)
A Residential Energy Management System (REMS) in smart grid provides capability to manage a daily load curve in order to reduce power consumption and energy cost. Consequently, (REMS) offers significant benefits for both the electricity suppliers and consumers in terms of control and schedule time of use of major appliances. In recent years, however, the rate of energy demand has increased rapidly throughout the world while the price of energy has been fluctuating. Numerous methods for (REMS) are used; this thesis analyzes many candidate scenarios during peak load periods comparing to the tariff to reduce the usage and its associated costs. It presents simulated results of proposed (REMS) to provide an automated least cost demand response. The main approach will be to ensure the satisfaction of the requirements with constraints on efficient use of energy. Multiphasic system behaviors of smart appliances in (REMS) with a realistic manner are proposed. / This thesis examines many mathematical models of home appliances in order to calculate the physical quantities that reflect the parameters’ impact and the system behavior. Main contribution determines the optimal solution of (TOU) problem to reduce energy cost and determine the best operation time by using (Linear optimization technique).
74

THREE DIMENSIONAL RECONSTRUCTION OF OBJECTS BASED ON DIGITAL FRINGE PROJECTION

Talebi, Reza 09 October 2013 (has links)
Three-dimensional reconstruction of small objects has been one of the most challenging problems over the last decade. Computer graphics researchers and photography professionals have been working on improving 3D reconstruction algorithms to fit the high demands of various real life applications. In this thesis, we implemented a 3D scanner system based on fringe projection method. Two different methods have been implemented and used as the unwrapping solution in fringe projection method. A parameterization tool has been created in order to generate different fringe patterns for distinctive needs in the fringe projection method. Considering our first practical implementation (based on phase shifting and multi wavelength techniques) the number of pictures used in phase shifting method has been decreased and the effects of reducing the fringe patterns on the level of precision of the 3D model have been investigated. Optical arrangement and calibration of the system (fringe projection method) have been studied, and numerous suggestions have been proposed to improve the precision of the system. Also, an evaluation method has been implemented based on calibration techniques. The error rate on both surface and height of the 3D model compare with the object has been calculated.
75

Fasta driftställen på internet : Ett koncept på (juridiskt) lös grund?

Johnsson, Jakob January 2015 (has links)
No description available.
76

Article: Reducing the electricity cost of a three-pipe water pumping system : a case study using software / White Rautenbach

Rautenbach, John White January 2004 (has links)
Efficient control is often the most cost-effective option to improve on the running cost of a Three-Pipe Water Pumping System. However, the effect of changing the control strategy (i.e. on energy consumption) is usually difficult to predict. To obtain this information more easily, a new simulation tool, QUICKcontrol, was developed. This new tool was used to investigate the energy cost savings potential in a Three-Pipe Water Pumping System. The influence of pump scheduling, dam level set points, control parameters and different combinations thereof was investigated. The simulation models were firstly verified with measurements obtained from the existing system to confirm their accuracy for realistic control retrofit simulations. With the aid of the integrated simulation tool it was possible to predict savings of R 195'000 per year with an average 3.8 MW of load shifted. / Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2005.
77

Comparison between automated and manual DSM pumping projects / R.P. Richter

Richter, Rudolph Petrus January 2008 (has links)
The purpose of this dissertation is to identify the best alternative method of load shifting on clear water pumping systems in the mining industry. This can be done through a comparison analysis between manual and automated Demand Side Management (DSM) projects. The study holds benefits for Eskom and any client wishing to participate in the program. Eskom, by choosing the best method, will ensure sustainable load shifting while the client benefits financially through lower electricity costs. In order to perform this study, research was conducted on the requirements for additional electricity supply in South Africa. Research showed that there is an urgent requirement for additional electricity supply to ensure continued economical growth. DSM was identified as one of the most favourable methods that could be implemented to address the problem. A reason for this is DSM projects are economically viable and can be implemented in a relatively short time. The initiative would also decrease the need for increasing electrical generation capacity. During the research study important information regarding the computation process for load shifting and cost saving performance was gathered. Research was also conducted on the effect of DSM on labour and maintenance cost reduction, as well as economical engineering methods that can be used for alternative selection. The difference in performance between automated and manual systems was compared. The results showed that a 40% improvement of automated systems over manual systems were attainable and sustainable. This will realise a total saving of approximately 45% in electricity costs for the client. Savings in labour and maintenance costs are shown to be achievable through the automation of pumping systems. These saving results were used in the Engineering Economic alternative selection methods where applicable. Economic calculations confirmed that automated projects are the most viable control method. From the comparison study, it is shown that automated controlled systems are more advantageous than manually controlled systems. It will therefore be in the best interest of the client to automate a manually controlled pumping system, as it will result in additional load shifting and cost saving. / Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2009.
78

Comparison between automated and manual DSM pumping projects / R.P. Richter

Richter, Rudolph Petrus January 2008 (has links)
The purpose of this dissertation is to identify the best alternative method of load shifting on clear water pumping systems in the mining industry. This can be done through a comparison analysis between manual and automated Demand Side Management (DSM) projects. The study holds benefits for Eskom and any client wishing to participate in the program. Eskom, by choosing the best method, will ensure sustainable load shifting while the client benefits financially through lower electricity costs. In order to perform this study, research was conducted on the requirements for additional electricity supply in South Africa. Research showed that there is an urgent requirement for additional electricity supply to ensure continued economical growth. DSM was identified as one of the most favourable methods that could be implemented to address the problem. A reason for this is DSM projects are economically viable and can be implemented in a relatively short time. The initiative would also decrease the need for increasing electrical generation capacity. During the research study important information regarding the computation process for load shifting and cost saving performance was gathered. Research was also conducted on the effect of DSM on labour and maintenance cost reduction, as well as economical engineering methods that can be used for alternative selection. The difference in performance between automated and manual systems was compared. The results showed that a 40% improvement of automated systems over manual systems were attainable and sustainable. This will realise a total saving of approximately 45% in electricity costs for the client. Savings in labour and maintenance costs are shown to be achievable through the automation of pumping systems. These saving results were used in the Engineering Economic alternative selection methods where applicable. Economic calculations confirmed that automated projects are the most viable control method. From the comparison study, it is shown that automated controlled systems are more advantageous than manually controlled systems. It will therefore be in the best interest of the client to automate a manually controlled pumping system, as it will result in additional load shifting and cost saving. / Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2009.
79

Walking on two feet : Tagbanwa adaptation to Philippine society

Warner, Katherine January 1979 (has links)
Typescript. / Thesis (Ph. D.)--University of Hawaii at Manoa, 1979. / Bibliography: leaves 176-185. / Microfiche. / xi, 185 leaves ill. 29 cm
80

Gaddang agriculture the focus of ecological and cultural change /

Wallace, Ben J., January 1967 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1967. / Typescript. Vita. Description based on print version record. Includes bibliographical references.

Page generated in 0.0536 seconds