• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 2
  • Tagged with
  • 13
  • 13
  • 12
  • 12
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise numérica e experimental na determinação da potência térmica dissipada em componentes eletrônicos

Sousa, Reginaldo Ribeiro de [UNESP] 28 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-28Bitstream added on 2014-06-13T19:55:37Z : No. of bitstreams: 1 sousa_rr_me_ilha.pdf: 2111422 bytes, checksum: 55ec661a37c8225f8f3075712c8ec225 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Os objetivos deste trabalho são determinar a potência térmica dissipada dos componentes eletrônicos de forma experimental e verificar a eficácia do método através de simulações numéricas computacionais utilizando o software comercial ANSYS. O Software ANSYS foi usado como ferramenta de Dinâmica de Fluidos Computacional neste trabalho. Para a realização deste trabalho um ensaio experimental foi executado a fim de obter alguns dados para o cálculo da potência térmica dissipada, outros foram fornecidos pelo CPqD e Trópico. Foi montado um Laboratório Computacional com o apoio da Trópico e do CPqD na UNESP, campus de Ilha Solteira para a simulações numéricas. O método de cálculo de potência apresentou-se eficaz, de modo na melhor situação os resultados apresentaram um erro relativo médio de 1,94%. / The purpose of this study is to determine the thermal power dissipation of electronic components through an experimental test and verify the effectiveness of the method through numerical simulations using the computational software ANSYS commercial. Software ANSYS was used as a tool for Computational Fluid Dynamics for this work. For this work an experimental test was done to obtain some data to calculate the thermal power dissipation, others were supplied by CPqD, Nilko and Trópico. It was dubbed a Computer Laboratory with the support of the Trópico, CPqD and at UNESP, campus de Ilha Solteira for the numerical simulations. The method of calculation of power proved to be effective, that the better the results showed a mean relative error is 1.94%.
12

Modelagem e simulação da operação de sistema antigelo eletrotérmico de um aerofólio. / Modeling and simlulation of an electro-thermal airfoil anti-ice system operation.

Silva, Guilherme Araújo Lima da 11 March 2002 (has links)
No presente trabalho foi implementado um modelo matemático para simular o sistema antigelo eletrotérmico de um aerofólio. Por meio do programa ONERA2D simulou-se o escoamento potencial completo com velocidade 44,7 m/s (100 mph) e 89,4 m/s (200 mph) em torno de um aerofólio perfil NACA0012 de corda 0,914 m (3 pés) com ângulo de ataque de 0°, e calculou-se a eficiência de coleta local de gotículas de água com diâmetro mediano volumétrico de 20 μm. Foram simuladas quatro condições de teste com diferentes distribuições de fluxo de calor nos aquecedores elétricos do sistema antigelo. O modelo previu a distribuição de temperaturas na superfície sólida do aerofólio e no filme de água líquida, e as distribuições de fluxo de água líquida sobre a superfície do aerofólio (\"runback water\") e de coeficiente de transferência de calor por convecção de calor entre a superfície do aerofólio e o escoamento gasoso. Os resultados da simulação obtidos com o modelo foram comparados com resultados experimentais da NASA e os resultados numéricos dos programas LEWICE/ANTICE (EUA) e CANICE (Canada). Para as regiões molhadas pelo filme de água líquida, obteve-se um desvio máximo de temperatura de 2,6°C entre os resultados do presente modelo e o resultados experimentais. Para as regiões secas, onde não existe o filme de água líquida sobre a superfície do aerofólio, obteve-se um desvio de máximo de temperatura de 8°C. As previsões para distribuição de vazão de \"runback\", posição do término do filme de água líquida foram comparadas com os resultados do programa LEWICE/ANTICE. O modelo desenvolvido simula com adequada aproximação os efeitos da transferência de calor e de massa por convecção entre a superfície não-isotérmica do aerofólio ou do filme de água líquida e o escoamento gasoso, bem como os efeitos da transição entre o escoamento laminar e o turbulento na camada limite dinâmica e térmica e ainda a influência do escoamento do filme de água líquida sobre o desempenho do sistema de antigelo do aerofólio. / An electro-thermal anti-ice system was simulated with a mathematical model developed in the present work. A 44.7 m/s (100 mph) and 89.4 m/s (200 mph) full potential flow around a 0.914 m (3 ft) chord NACA0012 airfoil with 0° angle of attack and the local water catch efficiency of 20 μm median volumetric diameter droplets impingement were calculated by the numerical code ONERA2D. Four test conditions were simulated with four different heat flux distributions of the anti-ice system according to the experimental work developed at NASA. The model predicted distributions of solid surface and liquid water film temperatures, runback water flow and convection heat transfer coefficient between airfoil or water surface and gaseous flow. The simulated results obtained by the mathematical model developed were compared to NASA experimental results and the ones predicted by the numerical codes LEWICE/ANTICE (US) and CANICE (Canada). For the regions wetted by the water film, the present model provided 2.6°C maximum temperature deviations between the predicted results and experimental data. For the dry regions, where there is no liquid water on the airfoil surface, an 8°C maximum temperature deviation was obtained. The runback flow and water film ending point position were compared to LEWICE/ANTICE numerical results. The developed model predicts adequately the convection heat and mass transfer effects between the non-isothermal airfoil or liquid water film surface and the gaseous flow, as well the effects of laminar to turbulent flow transition within dynamic and thermal boundary layer and the influence of the liquid water film flow on the anti-ice system performance.
13

Modelagem e simulação da operação de sistema antigelo eletrotérmico de um aerofólio. / Modeling and simlulation of an electro-thermal airfoil anti-ice system operation.

Guilherme Araújo Lima da Silva 11 March 2002 (has links)
No presente trabalho foi implementado um modelo matemático para simular o sistema antigelo eletrotérmico de um aerofólio. Por meio do programa ONERA2D simulou-se o escoamento potencial completo com velocidade 44,7 m/s (100 mph) e 89,4 m/s (200 mph) em torno de um aerofólio perfil NACA0012 de corda 0,914 m (3 pés) com ângulo de ataque de 0°, e calculou-se a eficiência de coleta local de gotículas de água com diâmetro mediano volumétrico de 20 μm. Foram simuladas quatro condições de teste com diferentes distribuições de fluxo de calor nos aquecedores elétricos do sistema antigelo. O modelo previu a distribuição de temperaturas na superfície sólida do aerofólio e no filme de água líquida, e as distribuições de fluxo de água líquida sobre a superfície do aerofólio (\"runback water\") e de coeficiente de transferência de calor por convecção de calor entre a superfície do aerofólio e o escoamento gasoso. Os resultados da simulação obtidos com o modelo foram comparados com resultados experimentais da NASA e os resultados numéricos dos programas LEWICE/ANTICE (EUA) e CANICE (Canada). Para as regiões molhadas pelo filme de água líquida, obteve-se um desvio máximo de temperatura de 2,6°C entre os resultados do presente modelo e o resultados experimentais. Para as regiões secas, onde não existe o filme de água líquida sobre a superfície do aerofólio, obteve-se um desvio de máximo de temperatura de 8°C. As previsões para distribuição de vazão de \"runback\", posição do término do filme de água líquida foram comparadas com os resultados do programa LEWICE/ANTICE. O modelo desenvolvido simula com adequada aproximação os efeitos da transferência de calor e de massa por convecção entre a superfície não-isotérmica do aerofólio ou do filme de água líquida e o escoamento gasoso, bem como os efeitos da transição entre o escoamento laminar e o turbulento na camada limite dinâmica e térmica e ainda a influência do escoamento do filme de água líquida sobre o desempenho do sistema de antigelo do aerofólio. / An electro-thermal anti-ice system was simulated with a mathematical model developed in the present work. A 44.7 m/s (100 mph) and 89.4 m/s (200 mph) full potential flow around a 0.914 m (3 ft) chord NACA0012 airfoil with 0° angle of attack and the local water catch efficiency of 20 μm median volumetric diameter droplets impingement were calculated by the numerical code ONERA2D. Four test conditions were simulated with four different heat flux distributions of the anti-ice system according to the experimental work developed at NASA. The model predicted distributions of solid surface and liquid water film temperatures, runback water flow and convection heat transfer coefficient between airfoil or water surface and gaseous flow. The simulated results obtained by the mathematical model developed were compared to NASA experimental results and the ones predicted by the numerical codes LEWICE/ANTICE (US) and CANICE (Canada). For the regions wetted by the water film, the present model provided 2.6°C maximum temperature deviations between the predicted results and experimental data. For the dry regions, where there is no liquid water on the airfoil surface, an 8°C maximum temperature deviation was obtained. The runback flow and water film ending point position were compared to LEWICE/ANTICE numerical results. The developed model predicts adequately the convection heat and mass transfer effects between the non-isothermal airfoil or liquid water film surface and the gaseous flow, as well the effects of laminar to turbulent flow transition within dynamic and thermal boundary layer and the influence of the liquid water film flow on the anti-ice system performance.

Page generated in 0.056 seconds