• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Padronização dos Radionuclídeos 201Tl e 55Fe em sistema de coincidências 4(PC)-NaI(Tl) / STANDARDIZATION OF 201Tl AND 55Fe RADIONUCLIDES IN A 4(PC)-NaI(Tl) COINCIDENCE SYSTEM

Pires, Carlos Augusto 07 April 2008 (has links)
No presente trabalho foi desenvolvido o método de padronização de radionuclídeos produzidos em cíclotrons utilizando o sistema de coincidências 4(PC)-NaI(Tl) composto de um contador proporcional operando a 0,1 MPa. Os radionuclídeos selecionados, foram o 201Tl, de uso em medicina nuclear e o 55Fe padrão primário muito utilizado na calibração de espectrômetros de raios-x. O 201Tl desintegra pelo processo de captura eletrônica, seguido pela emissão de radiação gama. A taxa de desintegração foi determinada pela técnica de extrapolação linear da eficiência empregando dois métodos: discriminação eletrônica e absorvedores externos. As fonte radioativas foram preparadas em substratos de Collodion com espessura de 20 g cm-2. O sistema eletrônico utilizado é o convencional para este tipo de medida. Os eventos observados foram registrados empregando o método TAC. O 55Fe desintegra pelo processo de captura eletrônica decaindo diretamente para o estado fundamental do 54Mn, emitindo raios-x com aproximadamente 6 keV. A taxa de desintegração foi determinada pelo método do traçador. Esta técnica foi aplicada utilizando dois radionuclídeos traçadores, que decaem pelo processo de captura eletrônica seguido da emissão de fótons, são eles 51Cr e 54Mn. As medidas foram feitas com 1 e 2 absorvedores de Al com espessura de 150 g cm-2. A atividade foi obtida extrapolando para zero espessura de Al. As incertezas envolvidas e suas correlações foram analisadas seguindo a metodologia de matriz de covariâncias. / In the present work the procedure for the standardization of radionuclides using the 4(PC)-NaI(Tl) coincidence system was developed. The radionuclides selected were 201Tl, used in nuclear medicine, and 55Fe primary standard source, used for x-ray spectrometers calibration. The 4(PC)-NaI(Tl) is composed of a 4 proportional counter operated at 0.1MPa coupled to two NaI(Tl) crystals. The 201Tl decays by electron capture process followed by a prompt gamma-ray. The disintegration rate was determined by extrapolation technique using two methods: electronic discrimination and external absorbers. The radioactive sources were prepared in a 20 g cm-2 thick Collodion film. The conventional electronic system was used. The observed events were registered by the TAC method. The 55Fe decays by electron capture process to the ground state of 55Mn, emitting x-rays with around 6 keV. The standardization was obtained by the tracing method. This technique was applied using two radionuclides, which decay by electron capture process followed by a prompt gamma-ray, namely 51Cr and 54Mn, as tracers. Measurements with 1 and 2 aluminum foils, each 150 g cm-2 thick were carried out. The activity was obtained by extrapolation for zero thickness Al foil. The uncertainties were treated by means of matrix covariance methodology and takes into account all correlations involved.
2

Padronização dos Radionuclídeos 201Tl e 55Fe em sistema de coincidências 4(PC)-NaI(Tl) / STANDARDIZATION OF 201Tl AND 55Fe RADIONUCLIDES IN A 4(PC)-NaI(Tl) COINCIDENCE SYSTEM

Carlos Augusto Pires 07 April 2008 (has links)
No presente trabalho foi desenvolvido o método de padronização de radionuclídeos produzidos em cíclotrons utilizando o sistema de coincidências 4(PC)-NaI(Tl) composto de um contador proporcional operando a 0,1 MPa. Os radionuclídeos selecionados, foram o 201Tl, de uso em medicina nuclear e o 55Fe padrão primário muito utilizado na calibração de espectrômetros de raios-x. O 201Tl desintegra pelo processo de captura eletrônica, seguido pela emissão de radiação gama. A taxa de desintegração foi determinada pela técnica de extrapolação linear da eficiência empregando dois métodos: discriminação eletrônica e absorvedores externos. As fonte radioativas foram preparadas em substratos de Collodion com espessura de 20 g cm-2. O sistema eletrônico utilizado é o convencional para este tipo de medida. Os eventos observados foram registrados empregando o método TAC. O 55Fe desintegra pelo processo de captura eletrônica decaindo diretamente para o estado fundamental do 54Mn, emitindo raios-x com aproximadamente 6 keV. A taxa de desintegração foi determinada pelo método do traçador. Esta técnica foi aplicada utilizando dois radionuclídeos traçadores, que decaem pelo processo de captura eletrônica seguido da emissão de fótons, são eles 51Cr e 54Mn. As medidas foram feitas com 1 e 2 absorvedores de Al com espessura de 150 g cm-2. A atividade foi obtida extrapolando para zero espessura de Al. As incertezas envolvidas e suas correlações foram analisadas seguindo a metodologia de matriz de covariâncias. / In the present work the procedure for the standardization of radionuclides using the 4(PC)-NaI(Tl) coincidence system was developed. The radionuclides selected were 201Tl, used in nuclear medicine, and 55Fe primary standard source, used for x-ray spectrometers calibration. The 4(PC)-NaI(Tl) is composed of a 4 proportional counter operated at 0.1MPa coupled to two NaI(Tl) crystals. The 201Tl decays by electron capture process followed by a prompt gamma-ray. The disintegration rate was determined by extrapolation technique using two methods: electronic discrimination and external absorbers. The radioactive sources were prepared in a 20 g cm-2 thick Collodion film. The conventional electronic system was used. The observed events were registered by the TAC method. The 55Fe decays by electron capture process to the ground state of 55Mn, emitting x-rays with around 6 keV. The standardization was obtained by the tracing method. This technique was applied using two radionuclides, which decay by electron capture process followed by a prompt gamma-ray, namely 51Cr and 54Mn, as tracers. Measurements with 1 and 2 aluminum foils, each 150 g cm-2 thick were carried out. The activity was obtained by extrapolation for zero thickness Al foil. The uncertainties were treated by means of matrix covariance methodology and takes into account all correlations involved.
3

Padronização em sistema primário por coincidências 4πβ-γ e determinação das intensidades de emissão gama por decaimento dos radionuclídeos Cu-64 e Ho-166 / Primary standardization of 64Cu and 166Ho radionuclides in the 4πβ(PC)-γ coincidence system and determination of its gamma-ray emission probability per decay

Yamazaki, Ione Makiko 12 February 2019 (has links)
O Laboratório de Metrologia Nuclear (LMN) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) realizou a padronização primária dos radionuclídeos 64Cu e 166Ho. Esses radioisótopos são utilizados na Medicina Nuclear em investigações diagnósticas e em radioterapia. A atividade absoluta foi determinada utilizando o método de coincidências 4πβ(PC)- γ associado à técnica de extrapolação de eficiência. Para isto, foram utilizados um contador proporcional em geometria 4π acoplado ao um contador de cintilação NaI (Tl). Para a padronização do 64Cu foram utilizados dois sistemas para registro de dados: sistema TAC e sistema SCS. No sistema TAC é utilizado o módulo Time to Amplitude Converter (TAC) associado a um analisador multicanal, sendo que a eficiência do detector 4πPC foi variada por meio de absorvedores externos e foi aplicado fator de correção para as eficiências beta denominado fator Kawada. No sistema SCS (Software Coincidence System) o registro dos eventos foi feito por meio da digitalização dos pulsos, a eficiência do detector 4πPC foi variada por discriminação eletrônica e a atividade foi obtida pela extrapolação biparamétrica. A padronização do 166Ho em sistema de coincidências 4πβ(PC)- γ foi realizada utilizando o sistema de aquisição de dados por software, SCS (Software Coincidence System). Para determinação das probabilidade de emissão gama dos radionuclídeos foi utilizado um espectrômetro gama HPGe calibrado com ampolas padrão de 152Eu, 60Co, 133Ba, 137Cs e 241Am, calibradas no sistema primário 4πβ(PC)- γ. A probabilidade de emissão gama por decaimento do fóton de 1345,7 keV do 64Cu obtida foi de 0,472 (10) % apresentando um bom acordo com os dados da literatura. A probabilidade de emissão gama por decaimento do fóton gama de 1379,45 keV do 166Ho foi de 0,936 (4) %. Por meio destas medidas foi possível também a determinação das intensidades relativas de outros fótons emitidos por este radionuclídeo. Os resultados obtidos foram concordantes com a literatura dentro da incerteza experimental. / The procedure followed by the Nuclear Metrology Laboratory (LMN) at the Nuclear and Energy Research Institute (IPEN) for the primary standardization of 64Cu and 166Ho is described. These radionuclides are widely applied to Nuclear Medicine such as in diagnostic investigations and in radiotherapy. The absolute activity of both radionuclides were determined by the efficiency extrapolation method applied to 4πβ(PC)-γ coincidence counting system using a proportional counter in 4π geometry coupled with NaI(Tl) scintillation counter. The primary standardisation of 64Cu for the conventional coincidence counting, the events were registered using a Time to Amplitude Converter (TAC) system associated with a multi-channel analyzer and by a software coincidence counting system, SCS, a digital method for primary activity measurements that simplifies the setting of optimal coincidence parameters. For perfoming the standardization of 64Cu in the TAC system, the efficiency of the 4πβ(PC)-γ detector was varied using external absorbers and in order to correct the beta efficiency, the Kawada factor was applied. In the SCS counting, the events were registered by means of pulse digitalization and the efficiencies (εEC and εβ) were varied through eletronic discrimination. The biparametric method was used for determining the absolute activity and the result was in good agreement with the ones obtained with TAC system. The standardization of 166Ho in the primary system was performed using the software coincidence counting, SCS. The gamma-ray emission probability per decay of the main transitions of both radionuclides were determined using the results obtained from the primary method, the 4πβ(PC)-γ coincidence system, associated with a calibrated HPGe gamma-ray spectrometer with standard ampoules of 152Eu, 60Co, 133Ba, 137Cs e 241Am, previously standardized in the 4πβ(PC)-γ system. The gamma-ray emission probability per decay of the 1345,7 keV transition of 64Cu was 0,472 (10) %, in good agreement with the literature. The gamma-ray emission probability per decay of the 1379,45 keV transition of 166Ho was 0,936 (4) %. It were also determined the relative gamma ray emmission probability of other gamma rays for this nuclide . All the results obtained were in good agreement with the literature.

Page generated in 0.0698 seconds