• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 11
  • 9
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 56
  • 36
  • 23
  • 15
  • 15
  • 14
  • 11
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
52

Analýza složení samčího sexuálního feromonu různých populací tropické ovocné mušky Ceratitis capitata (Diptera, Tephritidae) / Analysis of male sex pheromone of different population of tropic fruit fly Ceratitis capitata (Diptera, Tephritidae)

Ježková, Zuzana January 2012 (has links)
The Ceratitis capitata is a very important agricultural pest, whose reproduction behaviour is controled by chemical signals. Males initiate mating by creating leks, where they release sexual pheromones to attract females. The main goal of this diploma thesis was to determine the influence of host plants on the composition of male sex-pheromones C. capitata and to compare emanations of wild males with those originating from laboratory population. We studied the chemical composition of volatiles, released by calling males C. capitata from laboratory and two wild populations, using two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC×GC-TOFMS), gas chromatography with electroantennographic and flame ionization detection (GC-EAD-FID). All data were statistically analyzed by multivariate data analyses. Significant differences were observed in the quantitative and qualitative composition of the chemical emanations among males from the three populations. The GC-EAD-FID analyses revealed fourteen antenally active compounds with a possible behavioral function. Isomenthone, geraniol, bornyl acetate, geranyl acetone and ethyl octanoate were newly identified antenally active compounds of C. capitata male sex pheromone. Statistical analyses indicated that males and females of...
53

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
54

Desenvolvimento e validação de metodologia analítica para análise de aços por espectrometria de fluorescência de raios X por dispersão de energia (EDXRF)

Krummenauer, Alex January 2017 (has links)
O desenvolvimento e validação de métodos analíticos é um procedimento necessário quando um método não normalizado é utilizado por um laboratório de ensaios. A validação de métodos também é um requisito específico da norma ABNT NBR ISO/IEC 17025, que determina os requisitos gerais para a competência dos laboratórios de ensaio e calibração. O objetivo da validação é demonstrar que o método analítico, nas condições em que é executado, produz resultados com a exatidão requerida. O Laboratório de Corrosão, Proteção e Reciclagem de Materiais (LACOR), da UFRGS, tem o ensaio de determinação de metais por fluorescência de raios X, acreditado pelo CGCRE/INMETRO, conforme ABNT NBR ISO/IEC 17025. O ensaio é feito usando o método de espectrometria de fluorescência de raios X por dispersão de energia (EDXRF). Este método, contudo, não é normalizado e, portanto, o mesmo foi validado, neste trabalho de pesquisa, para atender a este requisito. A validação foi feita com base no documento orientativo DOQ-CGCRE-08 e no guia EURACHEM. Os parâmetros de validação, para o ensaio quantitativo por EDXRF, que foram calculados neste trabalho são: seletividade; limite de detecção (LD) e limite de quantificação (LQ); linearidade e faixa de trabalho; veracidade de medição (tendência, erro normalizado, Z-score e comparação com método de referência) e precisão (repetibilidade, precisão intermediária e reprodutibilidade). Além disso, foi desenvolvida uma metodologia de cálculo de incerteza de medição para o ensaio por EDXRF Os resultados obtidos neste estudo demonstram que o método EDXRF, usado na determinação de metais em aços, é um método não normalizado validado e compatível com os resultados obtidos com os métodos de referência: espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF), fotométricos e espectrometria de absorção atômica (AAS). Inclusive, o WDXRF é um método de referência usado em muitas normas internacionais, que descrevem métodos de análise de aços por fluorescência de raios X, como ASTM E572 ou ASTM E1085. O estudo desenvolvido nesta dissertação permitiu que o LACOR mantivesse sua acreditação no ensaio de determinação de metais por fluorescência de raios X, na avaliação do CGCRE/INMETRO, no presente ano. Outros frutos deste trabalho foram a confecção das curvas de calibração do espectrômetro NITON XL3t GOLDD+ e a revisão do procedimento de ensaio, onde esses novos conhecimentos sobre a técnica EDXRF foram aplicados. Futuramente, este trabalho pode ser usado por outros pesquisadores para desenvolver estudos em outras matrizes metálicas, como cobre, alumínio, titânio ou níquel, e, também, em outras áreas de aplicação como jóias, reciclagem de materiais metálicos ou, até mesmo, para análise elementar de resíduos retidos em membranas de troca iônica. / The development and validation of analytical methods is a required procedure when a non-standard method is used by a testing laboratory. Method validation is also a specific requirement of the ABNT NBR ISO / IEC 17025, which determines the general requirements for the competence of testing and calibration laboratories. The purpose of validation is to demonstrate that the analytical method, under the conditions in which it is performed, produces results with the required accuracy. The Corrosion, Protection and Recycling Materials Laboratory (LACOR), at UFRGS, has the X-ray fluorescence metal analysis, accredited by CGCRE / INMETRO, according to ABNT NBR ISO / IEC 17025. The test is performed using Energy Dispersive X-Ray Fluorescence spectrometry, EDXRF method. This method, however, is not standardized; therefore, it was validated in this research to meet this requirement. The validation was based on the DOQ-CGCRE-08 document and the EURACHEM guide. The method performance calculated in this study for quantitative testing by EDXRF are: selectivity; limit of detection (LOD) and limit of quantification (LOQ); linearity and working range; trueness (bias, normalized error, Z-score and comparison with reference method) and precision (repeatability, intermediate precision and reproducibility). In addition, a measurement uncertainty calculation methodology was developed for the EDXRF testing The results obtained in this study demonstrate that the EDXRF method, used in the determination in the chemical analysis of steels, is a validated non-standard method and compatible with the results obtained with the reference methods: Wavelength Dispersive X-Ray Fluorescence spectrometry (WDXRF), photometric and atomic absorption spectrometry (AAS). In addition, WDXRF is a reference method used in many international standards, which describes analysis of steels by X-ray fluorescence spectrometry such ASTM E572 or ASTM E1085. The study developed in this dissertation allowed LACOR to maintain its accreditation in the test of metal by X-ray fluorescence analysis, in the CGCRE / INMETRO audit, this year. Other fruits of this work were the preparation of calibration curves of NITON XL3t GOLDD + spectrometer and complete revision of testing procedure, where this new knowledge about the EDXRF technique was applied. In the future, this work can be used by other researchers to develop studies in other base metals such as copper, aluminum, titanium or nickel, and also in other areas of application such as jewelry, recycling of metallic materials or even for analysis elemental residues retained in ion exchange membranes.
55

Avaliação da qualidade da água subterrânea utilizada para consumo humano na região rural do município de Toledo-PR / Evaluation of groundwater quality used for human consumption in the rural municipality of Toledo-PR

Pauli, Aline Roberta de 26 February 2014 (has links)
Made available in DSpace on 2017-07-10T18:08:02Z (GMT). No. of bitstreams: 1 Aline Roberta de Pauli.pdf: 2301101 bytes, checksum: 8af3bc68b4e97fd013ba37cc5e0792bd (MD5) Previous issue date: 2014-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Freshwater is a naturally scarce resource because there are few sources of that water-type around the world. Moreover, pollution and uncontrolled use of water resources are increasing this shortage. In particular, groundwater is a major source of freshwater for human use in the city of Toledo PR, where the quality of groundwater is often not assessed and checked for its potability recommended standards. This study aims to monitor and assess the quality of groundwater used for human consumption in the rural municipality of Toledo - PR. Groundwaters of ten deep wells were monthly sampled during a year (November/2012 to October/2013) in this regard. Elemental content measurements were performed by using the both highly-sensitivity techniques of Total reflection X-ray Fluorescence (TXRF) and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The mean values of physico-chemical parameters and elemental content of the groundwater were statistical correlated and compared with the current Brazilian environmental legislation. A cluster analysis was made as well in order to assess the similarity of the water composition among the set of the sampled groundwaters of studied wells. In addition, a canonical correspondence analysis was also applied to assess the possible relationship based on the characteristics of wells, such as depth, age of the plumbing and distance from the septic tank and water quality. A water balance was performed, verifying surplus and water deficiency at the study site. According to the results, all the assessed wells showed some disagreement regarding the maximum allowable values for the parameters analyzed by Ordinance No. 2914 of the Ministry of Health (BRAZIL, 2011) for drinking water, requiring this water to be treated so that it can be consumed without risk to health. Using a cluster analysis, it was found that some of the closest wells were also geographically more similar in their chemical composition and it is likely that the chemical characteristics of the well waters are related to the rock in which the aquifer is inserted. The canonical correspondence analysis showed little influence on the characteristics of well water quality. Using a water balance, it was observed that there is surplus water in almost all months studied, indicating that there may be aquifer recharge, which influences the quality of groundwater. / A água doce vem se tornando um recurso naturalmente escasso devido a existência de poucas fontes provenientes dessa água no mundo, além disso, há aumento dessa escassez em consequência da poluição e do uso desordenado dos recursos hídricos . A água subterrânea é umas das principais fontes de água doce, e no município de Toledo PR a qualidade dessa água não é frequentemente aferida e verificada quanto a isenção de contaminantes naturais ou antropogênicos que lhe garantam a condição de uso humano. O presente trabalho tem por objetivo monitorar e avaliar a qualidade da água subterrânea utilizada para consumo humano na área rural do munícipio de Toledo PR. Para isto, foram amostrados mensalmente 3 L de águas subterrâneas obtidos de dez poços tubulares distribuídos aleatoriamente na zona rural do munícipio de Toledo - PR. Foram determinados mensalmente os parâmetros físico-químicos e o conteúdo elementar da água subterrânea durante o período de um ano, sendo posteriormente avaliadas quanto ao atendimento às exigências das normas ambientais para a água de consumo humano. Quanto à análise do conteúdo elementar, duas técnicas espectrométricas, uma de emissão óptica por indução de plasma (ICP-OES) e a outra de fluorescência de raios X por reflexão total (TXRF) foram utilizadas. O conjunto de dados físico-químicos e de composição elementar foi tratado estatisticamente de modo a avaliar a similaridade na característica da água entre os poços, aplicando uma análise de agrupamento (clusters), e quanto a comparação dos dados físico-geográficos do poço (profundidade, antiguidade e distâncias às fossas sépticas) por meio de uma análise de correspondência canônica. Em complementação a tais análises, realizou-se um balanço hídrico para verificar excedentes e deficientes hídricos no local de estudo. De acordo com os resultados obtidos, todos os poços avaliados apresentaram alguma desconformidade em relação aos valores máximos permitidos para os parâmetros analisados pela Portaria nº 2.914 do Ministério da Saúde (BRASIL, 2011) para água de consumo humano, sendo necessário o tratamento da água para que esta possa ser consumida sem riscos a saúde. Pela análise de agrupamento, verificou-se que alguns dos poços mais próximos geograficamente foram também mais similares em sua composição química, sendo provável que as características químicas das águas dos poços sejam provenientes da rocha em que parte do aquífero Serra Geral está inserido. A análise de correspondência canônica demonstrou que há pouca influência da profundidade e antiguidade dos poços e distâncias às fossas sépticas sobre a qualidade da água. Pelo balanço hídrico pode-se observar que há excedente hídrico em quase todos os meses estudados, podendo haver recarga do aquífero Serra Geral, o que poderia influenciar a entrada de poluentes superficiais para dentro do aquífero, por percolação, o que levaria a uma possível alteração na qualidade da água subterrânea.
56

Bildgebung und chemische Analytik mit Laserdesorptions-Massenspektrometrie im Bereich Forensik und Astrophysik / Imaging and Chemical Analysis with Laser Desorption Mass Spectrometry in Forensics and Astrophysics

Beinsen, Alexander 21 June 2011 (has links)
No description available.

Page generated in 0.0844 seconds