1 |
Avaliação do grau de conversão de uma resina composta fotoativada por lâmpada halógena e LEDs, por meio de espectrometria no infravermelho e ultravioletaDaniel, Sandra Cristina Scarbi 16 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:22Z (GMT). No. of bitstreams: 1
Sandracr.pdf: 955996 bytes, checksum: 8d2e096cd1c87011d908615d47978334 (MD5)
Previous issue date: 2006-02-16 / The aim of this study was to evaluate the quantity of residual monomers of a
microhibrid composite resin, photocured with different types of light curing units:
halogen and LEDs based on different times of photopolymerization (10, 20 and 40
seconds). Samples of the composite resin were made with Teflon bipartite matrix with
a center hole of 6 mm diameter compatible with the tips of the light curing units. The
distance of the light guide curing unit to the composite samples was 4 mm. The
average a width of the samples Charisma® composite resin color A2 and SL were 2
mm. The curing units used were Optilux 401 (Demetron) and Optilight LD III
(Gnatus). The materials were prepared and weighed on an accuracy scale and
stored in solvent, in the dark, at room temperature for 24 hours. The solvent used to
separate the organic and inorganic load was chloroform thirty six samples were
made, stored in chloroform and analysed with infrared spectroscopy (FTIR) and the
presence of carbon double bonds were found. Another solvent investigated in this
study was methanol, because it is considered an efficient solvent for extracting
present monomers in the resin, with an advantage because it acts as an inhibitor in
this type of polymerization while maintaining the characteristic of the sample for
quantitative analysis. Parallel to that, one hundred new samples were made. They
were appropriately stored in methanol and analysed with UV- visible light
spectroscopy (UV-Vis), through observance spectrum. The collected data was
analysed in Origin 5.0 programs at the peak of observance in the same wavelength.
The percentage of residual monomers was analysed by ANOVA and Games Howell
tests. The results indicated that Charisma® composite resin color A2 showed less
residual monomers. The halogen and LEDs light cure units showed the same
percentage of residual monomers results, or rather, it showed a larger conversion of
monomers in polymers. The LED based system promoted a smaller conversion
degree compared to halogen light. The 10, 20 and 40 seconds of photocured
presented the same quantity of residual monomers. / Neste trabalho foi avaliada a quantidade de monômeros residuais de uma resina
composta micro-híbrida de duas cores, com dois aparelhos: halógena e outro à base
de LEDs, em três tempos de fotoativação (10, 20 e 40 s). Para a confecção dos
corpos-de-prova foi utilizada uma matriz bipartida de teflon com orifício central de 6
mm de diâmetro, compatível com as pontas dos equipamentos fotoativadores. A
distância da ponta ativa do fotopolimerizador aos corpos-de-prova foi de 4 mm. A
espessura média dos corpos-de-prova de resina composta Charisma® (Heraeus
Kulzer) cor A2 e SL foi de 2 mm. Os aparelhos utilizados foram: lâmpada halógena
Optilux 401 (Demetron) e Optilight LD III (Gnatus), à base de LEDs. Os materiais
foram preparados e pesados em balança analítica e armazenados durante 24 horas
em solventes ao abrigo da luz e à temperatura ambiente. O solvente utilizado para
separar a fração orgânica das partículas inorgânicas foi o clorofórmio. Foram
confeccionados 36 corpos-de-prova armazenados em clorofórmio e analisados em
espectrômetro de infravermelho (FTIR) e foi verificada a presença das ligações
duplas de carbono-carbono. Outro solvente utilizado neste experimento foi o
metanol, por ser um solvente eficiente para a extração dos monômeros presentes na
resina, com a vantagem de agir como inibidor deste tipo de polimerização,
preservando as características da amostra para a análise quantitativa.
Paralelamente foram confeccionados 120 corpos-de-prova devidamente
armazenados em metanol e analisados em espectrômetro de ultravioleta-visível (UVVis)
ou equipamento de espectrometria na região do ultravioleta-visível, através de
espectros de absorvância. A leitura e interpretação dos dados obtidos foram feitos
no programa Origin 5,0 nos picos de maior absorvância (%A) no mesmo
comprimento de onda (nm). A porcentagem de monômeros residuais foi analisada
pelo teste de Variância e teste de Games Howel. Os resultados evidenciaram que a
resina composta Charisma® cor SL apresentou uma menor quantidade de
monômero residual, ou seja, apresentou uma maior conversão de monômeros em
polímeros. O sistema à base de LEDs promoveu um menor grau de conversão
comparado a lâmpada halógena. Os tempos de 10, 20 e 40 s de fotoativação
proporcionaram a mesma quantidade de monômeros residuais.
|
2 |
Determina??o do teor de diclofenaco s?dico em comprimidos por espectroscopia no infravermelho pr?ximo NIR com calibra??o multivariada PLSFerreira Neto, Francisco 29 February 2012 (has links)
Made available in DSpace on 2014-12-17T15:42:01Z (GMT). No. of bitstreams: 1
FranciscoFN_DISSERT.pdf: 2089554 bytes, checksum: 7f494e90c450d766696575e9a76682d2 (MD5)
Previous issue date: 2012-02-29 / Universidade Federal do Rio Grande do Norte / This work is combined with the potential of the technique of near infrared
spectroscopy - NIR and chemometrics order to determine the content of diclofenac tablets,
without destruction of the sample, to which was used as the reference method, ultraviolet
spectroscopy, which is one of the official methods. In the construction of multivariate
calibration models has been studied several types of pre-processing of NIR spectral data,
such as scatter correction, first derivative. The regression method used in the construction of
calibration models is the PLS (partial least squares) using NIR spectroscopic data of a set of
90 tablets were divided into two sets (calibration and prediction). 54 were used in the
calibration samples and the prediction was used 36, since the calibration method used was
crossvalidation method (full cross-validation) that eliminates the need for a validation set.
The evaluation of the models was done by observing the values of correlation coefficient R 2
and RMSEC mean square error (calibration error) and RMSEP (forecast error). As the forecast
values estimated for the remaining 36 samples, which the results were consistent with the
values obtained by UV spectroscopy / Neste trabalho s?o combinadas as potencialidades da t?cnica de espectroscopia no
infravermelho pr?ximo NIR e da quimiometria visando ? determina??o do teor de
diclofenaco em comprimidos, sem destrui??o da amostra, para o qual utilizou-se como
refer?ncia o m?todo de espectroscopia no ultravioleta, que ? um dos m?todos oficiais. Na
constru??o dos modelos de calibra??o multivariada estudou-se v?rios tipos de pr?processamento
dos dados espectrais NIR, como corre??o do espalhamento da luz, primeira
derivada. O m?todo de regress?o usado na constru??o dos modelos de calibra??o foi o PLS
(m?nimos quadrados parciais) utilizando dados espectrosc?picos do NIR de um conjunto de
90 comprimidos divididos em dois conjuntos (calibra??o e previs?o). Na calibra??o foram
usadas 54 amostras e na previs?o foram usadas 36, uma vez que o m?todo de calibra??o
utilizada foi o m?todo de valida??o cruzada (full cross validation) que dispensa a necessidade
de um conjunto de valida??o. A avalia??o dos modelos foi feita observando os valores de
coeficiente de correla??o R2 e os erros quadrados m?dios RMSEC (erro de calibra??o) e
RMSEP (erro de previs?o). Sendo os valores de previs?o estimados para as demais 36
amostras, o qual os resultados se mostraram coerentes com os valores obtidos por
espectroscopia no ultravioleta
|
3 |
Development and characterization of novel organic coatings based on biopolymer chitosanKumar, Girdhari. January 2006 (has links)
Thesis (Ph. D.)--Ohio State University, 2006. / Full text release at OhioLINK's ETD Center delayed at author's request
|
4 |
The UV photoelectron spectroscopy of transients : An experimental and computational investigation of electronic structure and reaction mechanisms /Bajorek, Tom. Werstiuk, Nick H. January 2003 (has links)
Thesis (Ph.D.)--McMaster University, 2003. / Advisor: N. Werstiuk. Includes bibliographical references (leaves 148-156). Also available via World Wide Web.
|
5 |
Multivariate analyses of near-infrared and UV spectral dataDogra, Jody A. Busch, Kenneth W. Busch, Marianna A. January 2009 (has links)
Thesis (Ph.D.)--Baylor University, 2009. / Includes bibliographical references (p. 184-195).
|
6 |
Coumarin-based molecular probes : exploring the spectroscopic properties of complex mixtures and applications in colloid chemistryZhao, Shangqing January 2018 (has links)
Warfarin is a well-known anticoagulant drug that is used to prevent cardiovascular disease and blood coagulation such as thrombosis. In this study, the main aim was to investigate the photo physical characteristics of warfarin in the different molecular environments provided by sodium dodecyl sulfate (SDS) micelles by using ultraviolet absorption and fluorescence emission spectroscopic techniques. Warfarin and a structural analogue not existing in solution as a cyclic hemiketal, phenprocoumon, were mixed with different concentrations of SDS and spectral changes for these warfarin and phenprocoumon were recorded. Interestingly, results demonstrated, based on an evident increase in the absorption intensity at 273 nm and an evident blue shift in the fluorescence emission spectrum after the addition of an increasing concentration of SDS, that primarily the cyclic hemiketal isomer of warfarin was found to be solvated by SDS micelles at an apparent recorded critical micelle concentration of ~8mM. Altogether these observations suggest that warfarin may be used as a molecular probe to explore the polarities of complex colloidal mixtures. Moreover, the possibility of using micelles for controlling the isomeric state of warfarin is interesting and can potentially be used for better controlling dosage of warfarin thereby reducing side effects.
|