• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Inläckage i spillvattenledningar i Rengsjö : En utredning baserad på ammoniummetoden

Thor, Elin January 2016 (has links)
Denna studie handlar om en metod som används för att lokalisera inläckage av tillskottsvatten på spillvattennät. Grunden är de praktikperioder som författaren har haft hos VA-bolaget Helsinge Vatten AB och då det utförts flera försök till att utreda inläckage i spillvattenledningarna. Metoden går ut på att analysera koncentrationen av ammonium i flödet som hämtas från brunnarna ute på nätet. Analyserna sker med hjälp av en portabel spektrofotometer tillsammans med reagenskyvetter som analyserar koncentrationen på bara 15 minuter. Detta ger en indikation på hur utspätt spillvattnet är, om det är utspätt av tillskottsvatten så visar analysen ett lågt värde vilket tyder på inläckage av dagvatten, grundvatten eller dricksvatten. Denna metod är framtagen av Norrköping Vatten och Avfall som har lyckats bra med att lokalisera inläckage med metoden. Norrköping Vatten och Avfall är en stor källa till denna studie med sin rapport ”Minskning av in- och utläckage genom aktiv läcksökning”(Uusijärvi, 2013).  I rapporten redovisas de ammoniumanalyser som har gjorts med tillhörande diagram för att tydliggöra resultaten. Eftersom spillvattennät ofta hör samman med pumpstationer och reningsverk som påverkar elförbrukning har statistik tagits fram för den pumpstation som analysområdet hör samman med. Elförbrukning har jämförts med nederbördsmätning för att se om ledningsnätet är påverkat av nederbörd, eftersom pumpstationen får arbeta mer om det är tillskottsvatten i ledningarna.  För att få fram en uppskattad mängd inläckage så har en beräkning gjorts med hjälp av en mall som Norrköping vatten och avfall har tagit fram. Där används analysvärden som tyder på inläckage tillsammans med antal abonnenter, ledningssträcka och storförbrukares avlopp. Tillsammans blir det ett värde på uppskattat inläckage i liter per dygn och meter ledning(L/D/M).  I rapporten finns det tre områden som ingår i byn Rengsjö som är utredda med ammoniummetoden. I ett testområde blev resultatet inte som önskat men lärorikt för personalen. Ett område gav resultat som visar på god kvalitet av nätet med en jämförelse av torr- och regnväder. Samt ett område där ett troligt inläckage upptäckts som kommer utredas vidare under sommaren. Detta fynd kan ge stora mängder tillskottsvatten, vilket uppfyller delar av de mål som formulerats i rapporten, dvs. att hitta inläckage för att planera vidare utredning. Tillsammans med resultaten för varje område finns en omfattande diskussion där alla aspekter som påverkar de uppmätta analysvärdena tas upp.  Som slutsats konstateras ammoniummetoden som mycket framgångsrik i syfte för Helsinge Vatten att systematiskt kunna kartlägga och utreda sina spillvattennät. Det är en kostnadseffektiv och inte så resurskrävande metod som företaget själv kan använda på en lagom nivå. / This study aims to locate the intrusion of excess water in the sewage networks, analyzing the concentration of ammonium in the flow that is obtained from the wells in the network. The foundation for the work is the author’s previous attempts to investigate stormwater at the VA-company Helsinge Vatten AB. The analysis is carried out by using a portable spectrophotometer with such reagents that can measure ammonium concentration in just 15 minutes. This gives an indication of how diluted effluent is. If  it is diluted by excess water the analysis shows a low value which is indicating intrusion of possibly surface water, groundwater or drinking water. This method is developed by Norrköping vatten och avfall, who have been a major reference of this report, with their study “Minskning av in- och utläckage genom aktiv läcksökning”(Uusijärvi, 2013).  Results from the ammonium analyses have been presented with associated charts. Because the sewage networks often are associated with pumping stations and wastewater treatment plants, which effect the electricity consumption, the electricity consumption has been documented for the pump stations in the area of study. The electricity consumption increases when the pumps are working. A analysis has been made by comparing the electricity consumption and the precipitation to see if the sewage network is influenced by precipitation.  In order to obtain an estimated amount of excess water intrusion, a calculation have been made by using a template produced by Norrköping Vatten och Avfall. In the calculation, values indicating water intrusion along with the number of subscribers, management and those who discharge most wastewater have been used. Together it gives a result of estimated intrusion in liters per day and meter network (L/D/M).  In the report, three areas located in the village Rengsjö have been investigated by using this method. The first area where the outcome was not as desired, but very instructive for the staff. The second area gave results that show the good quality of the net with a comparison of dry and wet weather. And also an area where a likely intrusion is detected and will be investigated further during the summer. This finding can indicate large amounts of stormwater. Those findings compiles with parts of the objectives formulated in the report, to find the intrusion and to plan for further investigation. Together with the results for each area, include an extensive discussion in which all aspects that influence the measured analyses have been taken up.  The report shows that the ammonium method  has been proved to be successful in identifying excess water intrusion in Helsinge Vatten’s sewage networks. This method does not rely on many resources, and therefore it is suitable for companies that wish investigate excess water instruction in a cost-effective way.
2

Distributed Temperature Sensing för kontroll av inläckage i spillvattenledningar / Using Distributed Temperature Sensing to detect infiltration and inflow in foul sewers

Moa, Sandberg January 2021 (has links)
Infiltration and inflow (I/I) are common problems in the foul sewer system. A method to detect I/I that is not commonly used in Sweden is DTS, Distributed Temperature Sensing. DTS is based on continuous measurements of temperature over a predetermined distance in the sewer system. The I/I is detected as temperature differences in the temperature data that is registered in the sewer system. The measurements often take place over a couple of weeks or months in the sewer system. The aim of this project was to review previous studies where DTS was used to detect I/I in foul sewers.  Data from a wastewater treatment plant in Umeå together with meteorological data were analysed to be able to visualize the problem of I/I and then suggest how DTS can be applied in Sweden. Both automated and visual analyses was performed to find if there were any relationships between wastewater temperature, wastewater flow and precipitation.   The outcome was that it is possible to apply DTS in the foul sewages to detect I/I. DTS seemed to be able to detect I/I in all types of sewage material, however it is dependent on that the I/I temperature differs from the temperature of the foul sewage water. It is an expensive technique but if it is meant to be used many times to analyse bigger areas it can be worth the costs. If larger areas are to be investigated, the costs for DTS and current methods are approximately the same.  At the wastewater treatment plant in Umeå, a slight relationship between wastewater temperature, wastewater flow and precipitation could be detected. The degree of dilution was calculated to 1,34 which means that about 25% of the sewage water is I/I. The conclusion from this was that I/I exists in the foul sewers in Umeå. The leakage points could not be located with this analysis. DTS could be a possible method to detect the leakage points of I/I in foul sewers. Unlike smoke tests, colouring and video-inspection of the sewers, DTS might be able to detect smaller leakage points. / Tillskottsvatten är ett vanligt problem i spillvattenledningsnätet. DTS, Distributed Temperature Sensing är en metod som inte är vanlig i Sverige för kontroll av spillvattenledningar. Tekniken bygger på kontinuerliga temperaturmätningar under en tidsperiod över en förutbestämd sträcka och registrerar temperaturavvikelser som kan uppstå i samband med inläckage av tillskottsvatten. Syftet med projektet var att granska tidigare utförda studier med DTS för att ta reda på hur tekniken kan användas för att lokalisera inläckage i spillvattenledningar. För att vidare illustrera problematiken med tillskottsvatten i spillvattennätet samt föreslå hur DTS kan appliceras i Sverige genomfördes en analys av mätdata på inkommande vatten till reningsverket på Ön, Umeå. Både visuella och automatiserade analyser genomfördes där tolkningar gjordes utifrån mätdata från reningsverket tillsammans med nederbörds- och lufttemperaturdata. En regressionsanalys genomfördes som automatiserad analys för att undersöka eventuella samband mellan spillvattentemperatur, spillvattenflöde och nederbörd. Projektet inleddes med en litteraturstudie där det utreddes hur DTS fungerar teoretiskt och praktiskt. Litteraturstudien visade att DTS är praktiskt möjligt att applicera i spillvattenledningsnätet för att leta inläckagepunkter för tillskottsvatten. Inläckage kan registreras som ökningar eller sänkningar i spillvattentemperaturen beroende på lufttemperaturen. Den är inte beroende av material på ledningarna men däremot är DTS beroende av att tillskottsvattnet är av annan temperatur än spillvattnet. Det är en dyr teknik men kan vara värt investeringskostnaderna om mätningar tänkt ske många gånger under längre perioder. Vid kontroll av större områden med hjälp av röktest kombinerat med färgning av vatten och filmning är kostnaderna ungefär de samma. Utifrån mätdatan från reningsverket och nederbördsdatan från Umeå universitet kunde vissa samband påvisas mellan spillvattentemperatur, spillvattenflöde och nederbörd. Ett visst samband kunde även urskiljas mellan spillvattentemperatur och spillvattenflöde. Utspädningsgraden av spillvattnet beräknades till 1,34 vilket innebär att cirka 25% av vattnet i spillvattenledningarna är tillskottsvatten. Slutsatsen som kunde dras utifrån detta var att tillskottsvatten existerar i spillvattenledningsnätet som leder till reningsverket på Ön i Umeå. Däremot kunde inga slutsatser dras för att säga var inläckage av tillskottsvatten sker. DTS skulle kunna appliceras i ledningsnäten för att undersöka närmare var inläckagepunkterna är och tillskillnad från rökning, färgning av vatten och filmning som används idag kan DTS sannolikt upptäcka fler typer av inläckage.

Page generated in 0.0758 seconds