Vliv vodivých vzorků na vznik deformací vf magnetického pole / Impact of conductive material on RF magnetic field deformationVondra, Petr January 2009 (has links)
The work analyses formation of deformations of RF magnetic field within the environment of electrically and magnetically conductive materials. An analytic solution of the problem is created and the problems of numerical modeling are solved. In theoretical way, the work also familiarize with the use of magnetic resonance imaging method - the spin echo method (SE), with its features and possibilities of its use within the aim of the project. This method is used for experimental measurements of electrically conductive materials in the NMR laboratory in ISI AV Czech Republic. Results of the simulation are compared with results of the experimental measurement.
|
12 |
Zvýraznění kontrastu pro rozlišení tkání a detekci kontrastních nanočástic metodami magnetickorezonančního zobrazování / Contrast enhancement for tissue discrimination and contrast nanoparticle detection by MRIBačovský, Jaromír January 2013 (has links)
Magnetic resonance imaging is a routine and powerful diagnostic technique capable of providing detailed information about the structure and composition of the tissues. This diploma thesis is concerned with the mechanisms of contrast origin and contrast modifications by molecular and nanoparticle contrast agents. First sections of the thesis summarize basic knowledge about pulse sequences and it aims to provide an overview on MRI contrast agent with a special emphasis on paramagnetic gadolinium contrast agents and superparamagnetic nanoparticles. The main purpose of this study is to develop the software called MRICalc, which is able to optimize contrast in MRI images. Based on analysis of signal formula of typical pulse sequences, MRICalc is able to propose the parameters of the pulse sequence for compartment-specific enhancement of the contrast. User chooses from the list of the samples and after calculation he obtains the values of echo time, repetition time and flip angle, all of which simultaneously seem to create the appropriate setting to enhance the contrast. MRICalc also allows to plot contrast function with respect to the chosen parameter. Software, including its graphical user interface, is designed in Python. The sample consists from solution of CuSO4 and distilled water was designed to verify the correct function of MRICalc. Sulphate represents a contrast agent. Preclinical MR system Bruker BioSpec 94/30 USR located at Institute of Scientific Instruments of the ASCR, v.v.i was used to measure contrast curve of FLASH pulse sequence, which is a typical representative of gradient echo. Results of the measurement were compared to the theoretical model provided by MRICalc.
|
13 |
INTERAKCE V ROZTOCÍCH A GELECH NA PODNĚTY REAGUJÍCICH POLYMERNÍCH SYSTÉMŮ STUDOVANÝCH NMR SPEKTROSKOPIÍ / Interactions in solutions and gels of stimuli-responsive polymer systems investigated by NMR spectroscopyKonefał, Rafał January 2018 (has links)
Stimuli-responsive (stimuli-sensitive, intelligent, or smart) polymers are polymer materials which, after small external stimuli, evidently change their physical or chemical properties. Smart polymers can be classified according stimuli they respond to such as: temperature changes, mechanical stress, light irradiation, ultrasonic treatment, application of external magnetic as well as electric field, changes of pH, ionic strength, addition of the chemical agents and presence of biomolecules and bioactive molecules. Stimuli-responsive synthetic polymer systems has attracted considerable attention due to wide range of applications, i.e. controlled drug delivery and release systems, diagnostics, tissue engineering and 'smart' optical systems, as well as biosensors, microelectromechanical systems, coatings, and textiles. Among the types of stimuli for this dissertation temperature, pH and reactive oxygen species (ROS) responsive polymer systems were studied. In case of thermoresponsive polymers, when polymer chains are molecularly dissolved in a good solvent, changes (increasing or decreasing) of temperature result in insolubility (globular nanoparticles formation) of polymer chains, called temperature induced phase-separation. pH responsive polymers change properties such as: solubility, volume (gels),...
|
14 |
Nové typy a principy optimalizace digitálního zpracování obrazů v EIT / New Optimization Algorithms for a Digital Image Reconstruction in EITKříž, Tomáš January 2016 (has links)
This doctoral thesis proposes a new algorithm for the reconstruction of impedance images in monitored objects. The algorithm eliminates the spatial resolution problems present in existing reconstruction methods, and, with respect to the monitored objects, it exploits both the partial knowledge of configuration and the material composition. The discussed novel method is designed to recognize certain significant fields of interest, such as material defects or blood clots and tumors in biological images. The actual reconstruction process comprises two phases; while the former stage is focused on industry-related images, with the aim to detect defects in conductive materials, the latter one concentrates on biomedical applications. The thesis also presents a description of the numerical model used to test the algorithm. The testing procedure was centred on the resulting impedivity value, influence of the regularization parameter, initial value of the numerical model impedivity, and effect exerted by noise on the voltage electrodes upon the overall reconstruction results. Another issue analyzed herein is the possibility of reconstructing impedance images from components of the magnetic flux density measured outside the investigated object. The given magnetic field is generated by a current passing through the object. The created algorithm for the reconstruction of impedance images is modeled on the proposed algorithm for EIT-based reconstruction of impedance images from voltage. The algoritm was tested for stability, influence of the regularization parameter, and initial conductivity. From the general perspective, the thesis describes the methodology for both magnetic field measurement via NMR and processing of the obtained data.
|
15 |
Nízkoteplotní rastrovací tunelová mikroskopie / Low temperature scanning tunneling microscopySojka, Antonín January 2017 (has links)
The diploma thesis is divided into two main parts. The first part describes the production of chrome and cobalt tips for SP-STM with subsequent testing of chrome tips on the Fe-Ir system (111). Furthermore, the first results from the growth studies of niobium on iridium(111) are presented. In the second part is described in detail the experimental LT-STM microscope of the Faculty of Physical Engineering. The chapter deals with the development of the microscope and its testing on a HOPG sample under atmospheric and vacuum conditions. The chapter describes the biggest problems which were solved when the microscope was puting into operation state. The second part also introduces the design of a new vacuum transport system, which consists of a tip and sample transport pallet. At the end of the second part is described the testing of cooling systems for LT-STM and the design of their modifications.
|
16 |
Akvizice a předzpracování MRI obrazových sekvencí pro klinické perfusní zobrazování / MRI Acquisition and Preprocessing of Image Sequences for Clinical Perfusion ImagingKrchňavý, Jan January 2012 (has links)
This thesis describes the theory for static and dynamic magnetic-resonance imaging using contrast agents affecting T1 relaxation time. The available acquisition methods in the specified facility of Masaryk Oncological Institute in Brno are described. The sequences for subsequent experimental measurements are selected. The used phantoms are described. Acquisition protocol for measuring is described briefly and the evaluation method for the measured data is suggested. The best acquisition sequence and a method of measurements is chosen influenced by estimation of relaxation time T1, sensitivity and signal to noise ratio. Perfusion analysis is executed and perfusion parameters are calculated. The work was supported by the European Regional Development Fund and the State Budget of the Czech Republic (RECAMO, CZ.1.05/2.1.00/03.0101).
|