• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Microscopic tunneling experiments on atomic impurities in graphene and on magnetic thin films

Scheffler, Martha 24 August 2015 (has links) (PDF)
This thesis presents investigations on hydrogenated graphene by scanning tunneling microscopy and spectroscopy (STM/STS) as well as the implementation of spin-polarized STM. Preparation processes for a magnetic standard sample and spin-sensitive chromium tips are developed. The measurements on graphene reveal specific hydrogen adsorption sites in low coverage and the formation of a pattern at higher coverage. Both is found to be in agreement with previous predictions and calculations. Upon hydrogenation, an impurity midgap state emerges in the density of states which is measured directly for the first time. Complementing angle resolved photoemission experiments confirm that this state is dispersionless over the whole Brillouin zone. A routine is developed to prepare the standard sample system of ultra-thin iron films on tungsten (Fe/W(110)). Investigations on this system confirm the magnetic properties known from literature, including the presence of a spin spiral, and prove that it is well suited for the characterization of spin-polarized tips. Different approaches for the preparation of tips from the antiferromagnetic material chromium are tested. Among these, a promising new method is presented: The coating of crystalline chromium tips with fresh chromium material suggests reproducibility of the tip characteristics. The performance of the produced tips in STM measurements is excellent in regard to a fixed spin-polarization, high resolution and stability. Especially, a recovery of the tip magnetization direction proposed in this thesis makes this new preparation method superior to all processes yielding antiferromagnetic tips reported so far. / Inhalt der vorliegenden Arbeit sind Untersuchungen von hydogeniertem Graphen mittels Rastertunnelmikroskopie und -spektroskopie (RTM/RTS) sowie die Einführung spin-polarisierter RTM. Im Rahmen dessen wurden Präparationsprozesse für magnetische Standardproben und spin-sensitive Chrom-Spitzen entwickelt. Die Messungen an Graphen zeigen spezifische Wasserstoff-Adsorptionsstellen bei geringer Bedeckung und die Ausbildung eines Musters bei höherer Bedeckung, jeweils in Übereinstimmung mit Vorhersagen und Berechnungen. Der durch Hydrogenierung entstehende Störstellenzustand in der Bandlücke der Zustandsdichte wurde zum ersten Mal direkt gemessen. Ergänzende winkelaufgelöste Photoelektronenspektroskopieexperimente bestätigen, dass dieser Zustand in der gesamten Brillouinzone dispersionsfrei ist. Ein Verfahren zur Herstellung magnetischer Standardproben aus ultradünnen Eisenfilmen auf Wolfram (Fe/W(110)) wurde entwickelt. RTM-Untersuchungen an diesem System bestätigen die bereits aus der Literatur bekannten magnetischen Eigenschaften, insbesondere das Vorhandensein einer Spinspirale. Damit ist Fe/W(110) hervorragend geeignet für die Charakterisierung spin-polarisierter Spitzen. Verschiedene Ansätze, die zur Herstellung von Spitzen aus dem antiferromagnetischen Material Chrom verfolgt wurden, werden präsentiert, darunter auch eine vielversprechende neue Methode: Das Aufwachsen eines frischen Chromfilms auf kristalline Spitzen desselben Materials verspricht eine Reproduzierbarkeit von Spitzeneigenschaften. Der Einsatz von so hergestellten Spitzen in RTMMessungen ist geprägt von einer festgelegten Spin-Polarisation, hohem Auflösungsvermögen und Stabilität. Insbesondere die mögliche Reproduzierbarkeit der Magnetisierungsrichtung, die in dieser Arbeit diskutiert wird, macht diese Methode allen bisher berichteten Herstellungprozessen antiferromagnetischer Spitzen überlegen.
2

Microscopic tunneling experiments on atomic impurities in graphene and on magnetic thin films

Scheffler, Martha 16 July 2015 (has links)
This thesis presents investigations on hydrogenated graphene by scanning tunneling microscopy and spectroscopy (STM/STS) as well as the implementation of spin-polarized STM. Preparation processes for a magnetic standard sample and spin-sensitive chromium tips are developed. The measurements on graphene reveal specific hydrogen adsorption sites in low coverage and the formation of a pattern at higher coverage. Both is found to be in agreement with previous predictions and calculations. Upon hydrogenation, an impurity midgap state emerges in the density of states which is measured directly for the first time. Complementing angle resolved photoemission experiments confirm that this state is dispersionless over the whole Brillouin zone. A routine is developed to prepare the standard sample system of ultra-thin iron films on tungsten (Fe/W(110)). Investigations on this system confirm the magnetic properties known from literature, including the presence of a spin spiral, and prove that it is well suited for the characterization of spin-polarized tips. Different approaches for the preparation of tips from the antiferromagnetic material chromium are tested. Among these, a promising new method is presented: The coating of crystalline chromium tips with fresh chromium material suggests reproducibility of the tip characteristics. The performance of the produced tips in STM measurements is excellent in regard to a fixed spin-polarization, high resolution and stability. Especially, a recovery of the tip magnetization direction proposed in this thesis makes this new preparation method superior to all processes yielding antiferromagnetic tips reported so far.:1 Introduction 2 Basics 2.1 Scanning tunneling microscopy 2.2 Spin-polarized STM – access to magnetic information 2.3 Measurement setup 3 Probing local hydrogen impurities in quasi-free-standing graphene 3.1 Functionalization of graphene 3.2 In-situ fabrication of quasi-free-standing graphene and its functionalization 3.3 Interpretation of the results 3.4 Short summary 4 Chromium tips for spin-polarized tunneling experiments 4.1 Magnetism at the nanoscale 4.2 Growth and properties of Fe/W(110) 4.3 Preparation of tips with outstanding properties 4.4 Short summary 5 Summary and outlook / Inhalt der vorliegenden Arbeit sind Untersuchungen von hydogeniertem Graphen mittels Rastertunnelmikroskopie und -spektroskopie (RTM/RTS) sowie die Einführung spin-polarisierter RTM. Im Rahmen dessen wurden Präparationsprozesse für magnetische Standardproben und spin-sensitive Chrom-Spitzen entwickelt. Die Messungen an Graphen zeigen spezifische Wasserstoff-Adsorptionsstellen bei geringer Bedeckung und die Ausbildung eines Musters bei höherer Bedeckung, jeweils in Übereinstimmung mit Vorhersagen und Berechnungen. Der durch Hydrogenierung entstehende Störstellenzustand in der Bandlücke der Zustandsdichte wurde zum ersten Mal direkt gemessen. Ergänzende winkelaufgelöste Photoelektronenspektroskopieexperimente bestätigen, dass dieser Zustand in der gesamten Brillouinzone dispersionsfrei ist. Ein Verfahren zur Herstellung magnetischer Standardproben aus ultradünnen Eisenfilmen auf Wolfram (Fe/W(110)) wurde entwickelt. RTM-Untersuchungen an diesem System bestätigen die bereits aus der Literatur bekannten magnetischen Eigenschaften, insbesondere das Vorhandensein einer Spinspirale. Damit ist Fe/W(110) hervorragend geeignet für die Charakterisierung spin-polarisierter Spitzen. Verschiedene Ansätze, die zur Herstellung von Spitzen aus dem antiferromagnetischen Material Chrom verfolgt wurden, werden präsentiert, darunter auch eine vielversprechende neue Methode: Das Aufwachsen eines frischen Chromfilms auf kristalline Spitzen desselben Materials verspricht eine Reproduzierbarkeit von Spitzeneigenschaften. Der Einsatz von so hergestellten Spitzen in RTMMessungen ist geprägt von einer festgelegten Spin-Polarisation, hohem Auflösungsvermögen und Stabilität. Insbesondere die mögliche Reproduzierbarkeit der Magnetisierungsrichtung, die in dieser Arbeit diskutiert wird, macht diese Methode allen bisher berichteten Herstellungprozessen antiferromagnetischer Spitzen überlegen.:1 Introduction 2 Basics 2.1 Scanning tunneling microscopy 2.2 Spin-polarized STM – access to magnetic information 2.3 Measurement setup 3 Probing local hydrogen impurities in quasi-free-standing graphene 3.1 Functionalization of graphene 3.2 In-situ fabrication of quasi-free-standing graphene and its functionalization 3.3 Interpretation of the results 3.4 Short summary 4 Chromium tips for spin-polarized tunneling experiments 4.1 Magnetism at the nanoscale 4.2 Growth and properties of Fe/W(110) 4.3 Preparation of tips with outstanding properties 4.4 Short summary 5 Summary and outlook

Page generated in 0.046 seconds