• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 34
  • 6
  • 6
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 99
  • 99
  • 82
  • 34
  • 33
  • 29
  • 29
  • 29
  • 25
  • 24
  • 17
  • 15
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Study of the Square Wave Transformation of Point Processes

Dowling, Paul Douglas 10 1900 (has links)
Abstract Not Provided. / Thesis / Master of Science (MSc)
2

A Study of the Square Wave Transformation of Point Processes

Dowling, Paul Douglas 10 1900 (has links)
Abstract Not Provided. / Thesis / Master of Science (MSc)
3

\"Utilização de metodologia eletroanalítica para estudos de adsorção de pesticidas triazínicos em amostras de sedimentos do rio Mogi-Guaçu-SP\" / Electroanalytical methodology was employed aiming to study the behaviour of the triazinic pesticides Atrazine and Ametrine in water and sediment collected from the Mogi-Guaçu river.

Silva, Maria Raimunda Chagas 24 July 2006 (has links)
Neste trabalho foi utilizada uma metodologia eletroanalítica para o estudo do comportamento dos pesticidas triazínicos, Atrazina e Ametrina em água e sedimentos do rio Mogi-Guaçu. Para isto utilizou-se a técnica de voltametria de onda quadrada (SWV) e o eletrodo de gota suspensa de mercúrio (HMDE). Inicialmente, os parâmetros experimentais (e voltamétricos) foram otimizados a fim de se obter a melhor resposta, em termos de intensidade de corrente de pico e definição do perfil voltamétrico. As melhores condições encontradas foram: eletrólito suporte CaCl2 0,01 mol L-1 em pH 3,0 e 2,3, para Ametrina e Atrazina, respectivamente, f = 100 s-1; a = 50 mV e DEs=2,0 e 10,0, para Ametrina e Atrazina respectivamente. Após a otimização, curvas de trabalho foram construídas para os dois pesticidas. Foram determinados os limites de detecção (LD) e quantificação (LQ), fatores de recuperação, repetibilidade, reprodutibilidade e sensibilidade da metodologia utilizada. Os resultados obtidos utilizando esta metodologia eletroanalítica foram comparados com os obtidos por HPLC-UV. Para Ametrina e Atrazina em eletrólito preparado com água do Milli-Q, os valores de LD encontrados foram de 2,12 ?g L-1 e 1,16 ?g L-1 e os de LQ foram de 7,06 ?g L-1 e 3,90 ?g L-1, respectivamente. Os valores de LD obtidos utilizando HPLC-UV para Ametrina e para a Atrazina foram de 2,69 ?g L-1 e 1,37 ?g L-1, enquanto aqueles para o LQ foram de 9,01 e 10,62 ?g L-1, respectivamente. Observou-se, desta maneira, que os resultados obtidos usando as duas técnicas são muito próximos e inferiores aos valores recomendados pela Comissão Nacional do Meio Ambiente (CONAMA) para águas residuais e efluentes industriais, 50 ?g L-1 para a Atrazina. Além disto, os valores reportados acima são tão baixos quanto os valores máximos aceitos pela Enviromental Protection Agency (EPA - USA) para águas potáveis, 3 ?g L-1 e pela Agência Nacional de Vigilância Sanitária (ANVISA), também para águas potáveis, 2 ?g L-1. A aplicação da mesma metodologia para águas naturais forneceu parâmetros importantes para verificar o comportamento destes pesticidas em águas, principalmente no que se refere à sua persistência. Foram determinados os limites de detecção (LD) e quantificação (LQ), assim como os fatores de recuperação para amostras de água do Rio Mogi-Guaçu, coletadas em três pontos diferentes, utilizando a técnica de SWV. Para Ametrina em eletrólito preparado com água do rio, os valores de LD variaram entre 15,41 e 29,54 ?g L-1 enquanto que os valores de LQ situaram-se entre 51,38 e 98,49 ?g L-1. Já para a Atrazina, os valores de LD variaram entre 4,90 e 6,19 ?g L-1 e os valores de LQ entre 16,36 e 20,65 ?g L-1 respectivamente. Os fatores de recuperação para Ametrina variaram entre 98,12 e 98,50% e para Atrazina entre 98,00 e 98,80%. As fotodegradações dos pesticidas foram estudadas com a exposição à radiação solar de soluções contendo os pesticidas e preparadas com água do Milli-Q, água de rio e água de rio contendo amostras de sedimentos. Os decaimentos da corrente de pico de redução da Ametrina e da Atrazina com o tempo de exposição à luz solar, variaram conforme o ponto de coleta da água do rio Mogi- Guaçu e a natureza do pesticida. Assim, para a Ametrina as porcentagens de decaimento de corrente após 32 horas de exposição foram de 19,10% (água do Milli-Q); 28,24% (ponto 1); 47,62% (ponto 2) e 30,92% (ponto 3). Já para a Atrazina, as respectivas porcentagens de decaimento das correntes de pico de redução foram de 37,50%; 45,90%; 46,10% e 36,53%. Para soluções contendo os sedimentos, a porcentagem de degradação ficou por volta de 30% para Ametrina enquanto que para a Atrazina a diferença foi marcante, ficando em torno de 86%. Os valores dos coeficientes das isotermas de adsorção de Freundlich obtidos indicaram uma dependência da adsorção com o teor de matéria orgânica e argila no sedimento para os três pontos de coleta do sedimento. De acordo com o critério adotado pelo IBAMA, os pesticidas Ametrina e Atrazina apresentam adsorção baixa, ficando pouco adsorvidos no sedimento. Os valores do 1/n da isoterma de Freundlich variaram entre 1,00 e 1,15 indicando uma característica de partição linear para todos os pontos. Os valores de matéria orgânica para os três pontos de coleta, variaram de 5,45 a 15,16%. A matéria orgânica encontra-se revestindo grande parte das frações minerais do solo e sedimento. Estas frações minerais variam de 15,7 a 20,8%, sendo os teores de silte de 12,3 a 16,3%. / An electroanalytical methodology was employed aiming to study the behaviour of the triazinic pesticides Atrazine and Ametrine in water and sediment collected from the Mogi-Guaçu River. The square wave voltammetry (SWV) and the hanging mercury drop electrode (HMDE) were employed. In a first step, the experimental (and voltammetric) parameters were optimized in order to yield the highest current signals as well as the most well defined voltammetric profiles. The best conditions were achieved as: 0.01 mol L-1 CaCl2 as the support electrolyte at pH 3.0 and 2.3 for Ametrine and Atrazine respectively, f = 100 s-1, a = 50 mV and ?Es = 2.0 and 10.0 for Ametrine and Atrazine respectively. After this initial step, analytical curves were obtained for both pesticides. The corresponding detection (LD) and determination (LQ) limits were calculated, as well as the recovering factors, repeatability, reproducibility and sensibility for the analytical methodology, which was compared with those, obtained using the HPLC-UV. For Ametrine and Atrazine, in pure electrolyte the LD values were 2.12 and 1.16 ?g L-1, while the LQ ones were 7.06 and 3.90 ?g L-1, respectively. The same parameters, obtained with HPLC-UV yielded LD values of 2.69 and 1.37 ?g L-1 for Ametrine and Atrazine, respectively, while the LQ ones were 9.01 and 10.62 ?g L-1, respectively. In this way, it is apparent that the results obtained in this work were very close for both techniques and lower than the minimum limit allowed by the Conselho Nacional do Meio Ambiente (CONAMA) for waste water or industrial effluents, 50 ?g L-1. Moreover, they are close to the maximum allowed value for drinking water postulated by the Environmental Protection Agency (EPA – USA), 3 ?g L-1 and the Agência Nacional de Vigilância Sanitária (ANVISA), 2 ?g L-1. The application of the same methodology for natural water samples yielded important parameters to establish the behaviour of pesticides, mainly concerning with its persistency. It were determined the detection and quantification limits and recovering factors by the SWV technique, for river water samples collected in three different points. For Ametrine, the LD values for electrolytes prepared with river waters, varied between 15.41 and 29.54 ?g L-1, while the values for LQ were between 51.38 and 98.49 ?g L-1. The same values for Atrazine were determined between 4.90 and 6.19 for LD and 16.36 and 20.65 for LQ. The recovering factors for Ametrine were found to be between 91.12 and 98.50% and for Atrazine between 98 and 98.8%. The photodegradations of pesticide molecules were studied by exposition to daylight of solutions containing the pesticides prepared with Milli-Q water, river water and river water containing sediments. The peak current decaying for Ametrine and Atrazine with exposition time varied accordingly the water collection point in the Mogi-Guaçu River and the nature of the pesticide. In this way, for Ametrine the percentage of decaying after 32 hours of exposition were 19.10% for Milli-Q water, 28.24% point 1, 47.62% point 2 and 30.92% point 3. For Atrazine, the respective decaying percentages of peak currents were 37.5%, 45.90%, 46.10% and 36.53% respectively. For solutions containing sediments (also collected in points 1, 2 and 3) the degradation percentage was around 30% for Ametrine, while for Atrazine the difference, around 86%. The coefficients from Freundlich adsorption isotherms presented values depending on the organic matter and clay present in the sediment samples. The pesticides presented low adsorption characteristic on the sediments. The 1/n values from Freundlich isotherm varied between 1.00 and 1.15, indicating a linear partition coefficient characteristic in all points. In this way, it is possible to associate the Kf values with the partition coefficients (Kd). The organic matter content for the three collection points varied between 5.45 and 15.15. The organic matter is found to be covering the mineral fractions of soils and sediments. These mineral fractions varied from 15.7 to 20.8%, while silt content were among 12.3 and 16.3%.
4

Implementation of a Function Generator

You, Xin, Wang, Yongchun January 2012 (has links)
Function generator has been widely used in each electronics fields recent years. In this thesis, the authors will introduce some basic structure and working principles of a function generator, moreover a function generator which can create three kinds of wave: sine wave, square wave and triangle wave has been implemented. There are many ways to build the function generator; a method of combine the operational amplifier and discrete components is introduced in this thesis. First use the RC Wien bridge oscillator to achieve sinusoidal wave; and convert it into square wave by using the shaping circuit. Lastly, use the integrating circuit to obtain triangle wave. The basic simulation software Multisim has been used to simulate the circuit.
5

Scanning Electrochemical Microscopy (SECM) with Amalgam Microelectrodes

Rudolph, Douglas Alexander 20 May 2005 (has links)
This thesis focuses on in-situ studies at the solid-liquid interface by combining scanning electrochemical microscopy (SECM) with gold and platinum mercury amalgam microelectrodes. It is shown that stripping voltammetry experiments at imaging amalgam microelectrodes provide laterally resolved insight on the electrochemistry of biogeochemically relevant processes. SECM provides information on electroactive surface processes with high spatial resolution, and offers the opportunity to study heterogeneous electron-transfer reactions. Thereby, chemical species of interest, such as metal ions, can be electrochemically detected at mercury amalgam electrodes. Platinum and gold mercury amalgam microelectrodes were developed for the detection of biogeochemically relevant analytes such as manganese and iron during SECM imaging experiments at the mineral/water interface establishing the fundamental basis of SECM imaging with amalgam microelectrodes. SECM experiments were performed for the quantitative determination of Mn2+ during the dissolution of microstructured manganese carbonate (rhodochrosite) precipitates at mildly acidic conditions. SECM images along with spatially resolved quantitative data on the Mn2+ concentration were obtained. This measurement concept was then extended to the investigation of the corrosion behavior of diamond-like carbon (DLC) protected zinc selenide (ZnSe) waveguides applied in mid-infrared attenuated total reflectance spectroscopy at strongly oxidizing conditions. The corrosion behavior of DLC coated and uncoated ZnSe crystals was studied obtaining laterally resolved information on the oxidative degradation of ZnSe at defects of the DLC layer utilizing SECM in combination with square wave anodic stripping voltammetry (SWASV) at gold amalgam microelectrodes. Thereby, insight on the corrosion behavior of ZnSe and concentration profiles of Zn2+ at oxidizing conditions was obtained. These results corroborate the utility of SECM imaging with amalgam microelectrodes for addressing relevant analytical questions. Finally, the developed amalgam microelectrodes were applied for SECM studies of iron-reducing proteins separated from Shewanella microbes in native polyacrylamide gels. After calibration of Pt/Hg microelectrodes in bulk solution for the targeted analytes (iron and sulfur species), SECM approach curves recorded above the native gel enabled positioning of the amalgam electrode in close proximity above protein bands with suspected iron-reducing activity. This technique enabled the (semi)quantitative determination of the anaerobic respiratory activity associated with microbial proteins/protein complexes responsible for the reductive dissolution of manganese and iron oxides above microbial protein bands separated in a native gel matrix.
6

Fabrication and characterization of gold ultramicro-nanoelectrode ensembles.

Lee, Shern-long 17 August 2005 (has links)
none
7

Desenvolvimento de um sistema voltametrico microfluidico / Development of a microfluidic voltammetric system

Killner, Mario Henrique Montazzolli, 1982- 25 October 2007 (has links)
Orientador: Jarbas Jose Rodrigues Rohwedder / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-10T02:35:04Z (GMT). No. of bitstreams: 1 Killner_MarioHenriqueMontazzolli_M.pdf: 2163718 bytes, checksum: 57b0452d9c198120c39d7c2faffd08e3 (MD5) Previous issue date: 2007 / Resumo: O presente trabalho descreve o desenvolvimento de um sistema voltametrico microfluidico, de um potenciostato de baixo custo e de um programa computacional para controle do potenciostato e aquisição de dados. O sistema voltamétrico microfluídico foi confeccionado empregando dois fotopolímeros, sendo um sólido e outro líquido. Foi também avaliado o uso de uma resina acrílica. Técnica de litografia utilizando radiação UVA foi empregada para a confecção dos protótipos. O fotopolímero líquido, a base de uretano-acrilato, apresentou as melhores características como flexibilidade, fácil manuseio e boa selagem dos canais analíticos. Estes canais foram confeccionados com largura de 600 mm e profundidade de 100 mm. O eletrodo de trabalho foi construido empregando um fio de platina de 75 mm de diâmetro e 1,5 mm de comprimento. Uma agulha de aço inox de 13 mm de comprimento e 0,45 mm de diametro foi empregada como eletrodo auxiliar e um fio de prata de 600 mm de diâmetro e 2,0 mm de comprimento recoberto com cloreto de prata foi utilizado na construção do eletrodo de referência. Os resultados de voltametria cíclica para soluções de diferentes concentrações de FeK4(CN)6 obtidos utilizando o sistema desenvolvido foram semelhantes aqueles obtidos empregando um potenciostato comercial. A determinação de Pb(II) em uma amostra certificada (452,2 mg L) apresentou um erro relativo de -3,9% e desvio relativo de 2,0% (n=3) empregando voltametria de redissolução anódica com varredura de onda quadrada / Abstract: The present work describes the development of a microfluidic voltammetric system, a low cost potentiostat, and a software used for data acquisition and control of the potentiostat. The microfluidic voltammetric system was formed using two photopolymers, one solid and one liquid. In addition, the use of an acrylic resin was evaluated. The photolitography using UVA radiation was used for the fabrication of prototypes. The liquid polymer of urethane-acrylate showed better characteristics such as flexibility, easy manipulation and good sealing of the analytical channels. The analytical channels were 600 mm width and 100 mm depth. The work electrode was made of a platinum wire of 75 mm of diameter and 1,5 mm of length. A stainless steel needle 13 mm long and with 0,45 mm of diameter was employed as auxiliary electrode and a silver wire of 600 mm of diameter and 2,0 mm long covered with AgCl was employed as reference electrode. The results obtained using Cyclic Voltammetry for solutions of different concentrations of FeK4(CN)6 and the developed system were similar to those obtained using a commercial potentiostat. The determination of Pb(II) in a certificated sample of water (452,2 mg L) showed a relative error of ¿3,9% and a relative standard deviation of 2,0% (n=3) employing anodic stripping voltammetry and square wave potential scan / Mestrado / Quimica Analitica / Mestre em Química
8

\"Utilização de metodologia eletroanalítica para estudos de adsorção de pesticidas triazínicos em amostras de sedimentos do rio Mogi-Guaçu-SP\" / Electroanalytical methodology was employed aiming to study the behaviour of the triazinic pesticides Atrazine and Ametrine in water and sediment collected from the Mogi-Guaçu river.

Maria Raimunda Chagas Silva 24 July 2006 (has links)
Neste trabalho foi utilizada uma metodologia eletroanalítica para o estudo do comportamento dos pesticidas triazínicos, Atrazina e Ametrina em água e sedimentos do rio Mogi-Guaçu. Para isto utilizou-se a técnica de voltametria de onda quadrada (SWV) e o eletrodo de gota suspensa de mercúrio (HMDE). Inicialmente, os parâmetros experimentais (e voltamétricos) foram otimizados a fim de se obter a melhor resposta, em termos de intensidade de corrente de pico e definição do perfil voltamétrico. As melhores condições encontradas foram: eletrólito suporte CaCl2 0,01 mol L-1 em pH 3,0 e 2,3, para Ametrina e Atrazina, respectivamente, f = 100 s-1; a = 50 mV e DEs=2,0 e 10,0, para Ametrina e Atrazina respectivamente. Após a otimização, curvas de trabalho foram construídas para os dois pesticidas. Foram determinados os limites de detecção (LD) e quantificação (LQ), fatores de recuperação, repetibilidade, reprodutibilidade e sensibilidade da metodologia utilizada. Os resultados obtidos utilizando esta metodologia eletroanalítica foram comparados com os obtidos por HPLC-UV. Para Ametrina e Atrazina em eletrólito preparado com água do Milli-Q, os valores de LD encontrados foram de 2,12 ?g L-1 e 1,16 ?g L-1 e os de LQ foram de 7,06 ?g L-1 e 3,90 ?g L-1, respectivamente. Os valores de LD obtidos utilizando HPLC-UV para Ametrina e para a Atrazina foram de 2,69 ?g L-1 e 1,37 ?g L-1, enquanto aqueles para o LQ foram de 9,01 e 10,62 ?g L-1, respectivamente. Observou-se, desta maneira, que os resultados obtidos usando as duas técnicas são muito próximos e inferiores aos valores recomendados pela Comissão Nacional do Meio Ambiente (CONAMA) para águas residuais e efluentes industriais, 50 ?g L-1 para a Atrazina. Além disto, os valores reportados acima são tão baixos quanto os valores máximos aceitos pela Enviromental Protection Agency (EPA - USA) para águas potáveis, 3 ?g L-1 e pela Agência Nacional de Vigilância Sanitária (ANVISA), também para águas potáveis, 2 ?g L-1. A aplicação da mesma metodologia para águas naturais forneceu parâmetros importantes para verificar o comportamento destes pesticidas em águas, principalmente no que se refere à sua persistência. Foram determinados os limites de detecção (LD) e quantificação (LQ), assim como os fatores de recuperação para amostras de água do Rio Mogi-Guaçu, coletadas em três pontos diferentes, utilizando a técnica de SWV. Para Ametrina em eletrólito preparado com água do rio, os valores de LD variaram entre 15,41 e 29,54 ?g L-1 enquanto que os valores de LQ situaram-se entre 51,38 e 98,49 ?g L-1. Já para a Atrazina, os valores de LD variaram entre 4,90 e 6,19 ?g L-1 e os valores de LQ entre 16,36 e 20,65 ?g L-1 respectivamente. Os fatores de recuperação para Ametrina variaram entre 98,12 e 98,50% e para Atrazina entre 98,00 e 98,80%. As fotodegradações dos pesticidas foram estudadas com a exposição à radiação solar de soluções contendo os pesticidas e preparadas com água do Milli-Q, água de rio e água de rio contendo amostras de sedimentos. Os decaimentos da corrente de pico de redução da Ametrina e da Atrazina com o tempo de exposição à luz solar, variaram conforme o ponto de coleta da água do rio Mogi- Guaçu e a natureza do pesticida. Assim, para a Ametrina as porcentagens de decaimento de corrente após 32 horas de exposição foram de 19,10% (água do Milli-Q); 28,24% (ponto 1); 47,62% (ponto 2) e 30,92% (ponto 3). Já para a Atrazina, as respectivas porcentagens de decaimento das correntes de pico de redução foram de 37,50%; 45,90%; 46,10% e 36,53%. Para soluções contendo os sedimentos, a porcentagem de degradação ficou por volta de 30% para Ametrina enquanto que para a Atrazina a diferença foi marcante, ficando em torno de 86%. Os valores dos coeficientes das isotermas de adsorção de Freundlich obtidos indicaram uma dependência da adsorção com o teor de matéria orgânica e argila no sedimento para os três pontos de coleta do sedimento. De acordo com o critério adotado pelo IBAMA, os pesticidas Ametrina e Atrazina apresentam adsorção baixa, ficando pouco adsorvidos no sedimento. Os valores do 1/n da isoterma de Freundlich variaram entre 1,00 e 1,15 indicando uma característica de partição linear para todos os pontos. Os valores de matéria orgânica para os três pontos de coleta, variaram de 5,45 a 15,16%. A matéria orgânica encontra-se revestindo grande parte das frações minerais do solo e sedimento. Estas frações minerais variam de 15,7 a 20,8%, sendo os teores de silte de 12,3 a 16,3%. / An electroanalytical methodology was employed aiming to study the behaviour of the triazinic pesticides Atrazine and Ametrine in water and sediment collected from the Mogi-Guaçu River. The square wave voltammetry (SWV) and the hanging mercury drop electrode (HMDE) were employed. In a first step, the experimental (and voltammetric) parameters were optimized in order to yield the highest current signals as well as the most well defined voltammetric profiles. The best conditions were achieved as: 0.01 mol L-1 CaCl2 as the support electrolyte at pH 3.0 and 2.3 for Ametrine and Atrazine respectively, f = 100 s-1, a = 50 mV and ?Es = 2.0 and 10.0 for Ametrine and Atrazine respectively. After this initial step, analytical curves were obtained for both pesticides. The corresponding detection (LD) and determination (LQ) limits were calculated, as well as the recovering factors, repeatability, reproducibility and sensibility for the analytical methodology, which was compared with those, obtained using the HPLC-UV. For Ametrine and Atrazine, in pure electrolyte the LD values were 2.12 and 1.16 ?g L-1, while the LQ ones were 7.06 and 3.90 ?g L-1, respectively. The same parameters, obtained with HPLC-UV yielded LD values of 2.69 and 1.37 ?g L-1 for Ametrine and Atrazine, respectively, while the LQ ones were 9.01 and 10.62 ?g L-1, respectively. In this way, it is apparent that the results obtained in this work were very close for both techniques and lower than the minimum limit allowed by the Conselho Nacional do Meio Ambiente (CONAMA) for waste water or industrial effluents, 50 ?g L-1. Moreover, they are close to the maximum allowed value for drinking water postulated by the Environmental Protection Agency (EPA – USA), 3 ?g L-1 and the Agência Nacional de Vigilância Sanitária (ANVISA), 2 ?g L-1. The application of the same methodology for natural water samples yielded important parameters to establish the behaviour of pesticides, mainly concerning with its persistency. It were determined the detection and quantification limits and recovering factors by the SWV technique, for river water samples collected in three different points. For Ametrine, the LD values for electrolytes prepared with river waters, varied between 15.41 and 29.54 ?g L-1, while the values for LQ were between 51.38 and 98.49 ?g L-1. The same values for Atrazine were determined between 4.90 and 6.19 for LD and 16.36 and 20.65 for LQ. The recovering factors for Ametrine were found to be between 91.12 and 98.50% and for Atrazine between 98 and 98.8%. The photodegradations of pesticide molecules were studied by exposition to daylight of solutions containing the pesticides prepared with Milli-Q water, river water and river water containing sediments. The peak current decaying for Ametrine and Atrazine with exposition time varied accordingly the water collection point in the Mogi-Guaçu River and the nature of the pesticide. In this way, for Ametrine the percentage of decaying after 32 hours of exposition were 19.10% for Milli-Q water, 28.24% point 1, 47.62% point 2 and 30.92% point 3. For Atrazine, the respective decaying percentages of peak currents were 37.5%, 45.90%, 46.10% and 36.53% respectively. For solutions containing sediments (also collected in points 1, 2 and 3) the degradation percentage was around 30% for Ametrine, while for Atrazine the difference, around 86%. The coefficients from Freundlich adsorption isotherms presented values depending on the organic matter and clay present in the sediment samples. The pesticides presented low adsorption characteristic on the sediments. The 1/n values from Freundlich isotherm varied between 1.00 and 1.15, indicating a linear partition coefficient characteristic in all points. In this way, it is possible to associate the Kf values with the partition coefficients (Kd). The organic matter content for the three collection points varied between 5.45 and 15.15. The organic matter is found to be covering the mineral fractions of soils and sediments. These mineral fractions varied from 15.7 to 20.8%, while silt content were among 12.3 and 16.3%.
9

Voltametrie s předřazenou extrakcí jako nový přístup pro rychlé stanovení formaldehydu v dřevěných výrobcích / Voltammetry with Preliminary Extraction as a New Approach for Rapid Determination of Formaldehyde in Wood-Based Products

Dvořák, Pavel January 2020 (has links)
The aim of the presented Diploma Thesis was to develop a new method for the indirect determination of formaldehyde in wood-based products using gas-diffusion microextraction coupled with electrochemical detection on unmodified screen-printed electrodes (MLEM-SPCE). Formaldehyde released from the sample is derivatized using an acetylacetone reagent present in an acceptor solution. The product of derivatization of formaldehyde with acetylacetone is 3,5-diacetyl-1,4-dihydrolutidine (DDL) which forms a selective oxidation voltammetric peak at a potential of 0.4 V. Detection and quantification limits of 0.57 mg kg−1 and 1.89 mg kg−1 , respectively, were obtained, together with intra- and inter-day precision below 10% (as relative standard deviation, RSD). The developed methodology was applied to determine formaldehyde content in seven samples. Similar results were obtained from the European standard method EN 717-3 with a significant reduction of total analysis time. The developed method MLEM-SPCE, which combines the use of a new sample preparation procedure for volatile compounds with the firstly introduced determination of formaldehyde (as the derivative product DDL) on unmodified SPCEs, proves to be a promising alternative for the determination of formaldehyde in wood-based products and other samples.
10

Investigação do comportamento eletroquímico do inseticida fipronil e desenvolvimento de metodologia eletroanalítica / Investigation of the electrochemical behavior of the insecticide fipronil and development of electroanalytical methodology

Amaral, Raquel Bonatto do 25 May 2012 (has links)
Essa tese de doutorado apresenta o estudo eletroquímico da oxidação do inseticida fipronil bem como o desenvolvimento de metodologias analíticas para a determinação deste composto em amostras de águas naturais. Os experimentos foram realizados sobre os eletrodos de compósito grafite-poliuretana (GPU) e carbono vítreo modificado com nanotubos de carbono de paredes múltiplas (GC-MWCNTs) utilizando a Voltametria de Onda Quadrada (SWV). A Voltametria Cíclica (CV) foi utilizada para diagnosticar o grau de reversibilidade da reação de oxidação do inseticida assim como a natureza do transporte do material eletroativo para a superfície dos eletrodos. Os resultados dos estudos da oxidação eletroquímica do fipronil utilizando o eletrodo de GPU mostraram que a oxidação do fipronil apresenta um em 0,70 V (vs. EAg/AgCl) e ocorre de forma totalmente irreversível e controlada por adsorção das espécies na superfície do eletrodo. Foram obtidas curvas analíticas para o fipronil no intervalo de 2,0 a 14,0 x 10-5 mol L-1, resultando um limite de detecção (LD) de 139 µg L-1 e Limite de Quantificação (LQ) de 480 µg L-1. Para a oxidação do fipronil no eletrodo GC-MWCNTs os resultados mostraram que a oxidação do fipronil apresenta apenas um pico em 0,50 V (vs. EAg/AgCl) e ocorre de forma totalmente irreversível e controlado por difusão a adsorção das espécies na superfície do eletrodo. Os LD e LQ obtidos foram de 26 µg L-1 e 147 µg L-1, respectivamente. O estudo por eletrólise a potencial controlado revelou que a oxidação do inseticida fipronil envolve a participação de um elétron. A metodologia desenvolvida para ambos os eletrodos foi aplicada em amostras de águas naturais, testes de recuperação foram realizados mostrando eficiência de recuperação 96,0% para o eletrodo de GPU e de 94,6% para o eletrodo de GC-MWCNTs. / In this thesis a study of the electrochemical oxidation of the insecticide fipronil and the development of analytical methodologies for the determination of this compound in natural water samples is presented. The experiments were performed at graphite-polyurethane composite electrodes (GPU) and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs-GC). The electrodes were caracterized using square wave voltammetry (SWV). Cyclic voltammetry (CV) was used to diagnose the degree of reversibility of the oxidation reaction of the insecticide as well as the nature of the transport of the electroactive material to the surface of the electrodes. The electrochemical oxidation of fipronil studies using the GPU electrode showed that fipronil oxidation presents a peak at 0.70 V (vs. EAg/AgCl) which is totally irreversible and controlled by adsorption of species on the electrode surface. Analytical curves were obtained for fipronil in the range 2.0 to 14 x 10-5 mol L-1, with a detection limit (LD) of 139 µg L-1 and a quantification limit (LQ) of 480 µg L-1. For the oxidation of fipronil in the GC-MWCNTs electrode the results showed that fipronil oxidation presents a peak at 0.50 V (vs. EAg/AgCl) which is totally irreversible and diffusion controlled the adsorption of species on the electrode surface. The LD and LQ were obtained 26 µg L-1 and 147 µg L-1, respectively. The study by controlled potential electrolysis showed that oxidation of the insecticide fipronil involves the participation of one electron. The methodology developed for both electrodes was applied to natural water samples, recovery tests were performed showing recovery efficiency of 96.0% for the GPU electrode and 94.6% for MWCNTs-GC electrode.

Page generated in 0.0458 seconds