1 |
乱流中の変動圧力の計測について辻, 義之, TSUJI, Yoshiyuki, 今飯田, 純, IMAIIDA, Jun, 阿部, 浩幸, ABE, Hiroyuki 07 1900 (has links)
No description available.
|
2 |
Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings AnalysisKimla, John 2009 December 1900 (has links)
The potential of static pressure reset (SPR) control to save fan energy in variable air
volume HVAC systems has been well documented. Current research has focused on the creation
of reset strategies depending on specific system features. As the commissioning process has
begun to require the prediction of savings, knowledge of the extent to which various SPR control
strategies impact fan energy has become increasingly important. This research aims to document
existing SPR control strategies and utilize building data and simulation to estimate fan energy
use.
A comprehensive review of the literature pertaining to SPR control was performed and
the results were organized into a top-down flow chart tool. Based on the type of feedback
available from a particular system, or lack thereof, this tool will facilitate the selection of a SPR
control strategy. A field experiment was conducted on a single duct variable air volume system
with fixed discharge air temperature and static pressure setpoints. Finally, an air-side model of
the experimental system was created using detailed building design information and calibrated
using field measurements. This model was used to estimate the fan energy required to supply
the trended airflow data using fixed static pressure (FSP) and SPR control based on zone
demand, system demand, and outside air temperature.
While utilizing trend data from November 1, 2008 to February 12, 2009, the FSP control
of the experimental system was used as the baseline for ranking the energy savings potential of
nine different forms of duct static pressure control. The highest savings (73-74%) were achieved
using zonal demand based SPR control. System demand based SPR control yielded savings
ranging from 59 to 76%, which increased when the duct sensor was positioned near the fan
discharge and under similar zone load conditions. The outside air temperature based SPR
control yielded savings of 65% since the experimental system supplied primarily perimeter
zones. Finally, increasing the FSP setpoint from 2 to 3 inWG increased fan energy by 45%,
while decreasing the setpoint from 2 to 1 inWG decreased fan energy by 41%.
|
3 |
Hydrofoil static pressure acquisition at high Reynolds number /Hamel, Joshua M. January 2001 (has links)
Thesis (M.S. in Mechanical Engineering)--University of Michigan, 2001. / Includes bibliographical references (p. 49). Also available online.
|
4 |
Analýza nadzvukového proudění v experimentální komoře při vložení tlakových a teplotních sond / Analysis of supersonic flow in experimental chamber by insertion of pressure and temperature probesŠabacká, Pavla January 2020 (has links)
For the supersonic flow mode, which occurs in the internal flow behind the aperture separating two spaces with a large pressure drop, the critical flow is a characteristic phenomenon. In the case of critical flow behind the aperture, a supersonic flow area with reduced pressure ending with a shock wave with a step change in state variables is created. When diagnosing velocities, which are obtained from the values of static and total pressure, due to the changes caused by the shock wave passage, correction of the diagnostic quantities obtained by measuring by means of mathematical relations taking into account the physical phenomena is necessary.
|
5 |
Srovnávací analýza proudění plynu clonou v nízkých tlacích pomocí mechaniky kontinua s metodou Monte Carlo / Comparative analysis of the gas flow through the aperture at low pressures using the continuum mechanics with the Monte Carlo methodMardanova, Elvira January 2021 (has links)
This thesis is based on the series of scholarly article dedicated to the issue ofpumping in the differential scanning chamber of an environmental scanning microscope. The thesis is based on Danilatos’s study where the pumping of the differential pumped chamber is solved by means of the Monte Carlo statistical method. The thesis performs analysis of gas flow at low pressures through orifice separating the spaces with a large pressure drop Dr. Danilate. The analyses will be used for the design of the experimental chamber which will serve for the experimental evaluation of the flow results in the chamber using the continuum mechanics.
|
6 |
Cavitation assessment of the Baihetan discharge tunnel – Using Computational Fluid Dynamics / Bedömning av risken för kavitation i utskovstunneln för Baihetankraftverket med CFD-beräkningar.Alderman, Carin, Andersson, Sophia January 2012 (has links)
Recently it has become more common in the construction of large dams to reuse diversion tunnels as flood discharge tunnels in the final structure. These tunnels handle large flows with the characteristics of open channel flow. When such large hydrological forces act upon a structure there are several problems to be expected. One of these is the occurrence of cavitation, which could have potential hazardous erosion as a consequence. Cavitation is the formation and collapse of bubbles that create a shockwave strong enough to erode the underlying material. The Baihetan dam is one of the largest hydro power projects in China at present. It has three discharge tunnels that all run the risk of developing cavitation damages. By modelling one of the tunnels using Computational Fluid Dynamics (CFD) it is possible to investigate where in the tunnel structure cavitation is likely to occur. This degree project assesses the risk of cavitation erosion in the Baihetan tunnel using the static pressure distribution, the velocity distribution and modern cavitation theory. Several modifications of the tunnel – including alterations in the gradient and construction parameters – are simulated in order to investigate if changes in the design can mitigate the cavitation problem. None of the analysed modifications completely eliminate the problem and aeration is recommended to counteract the problem. This study indicates where cavitation might be a problem in the Baihetan tunnel and can be used as a basis for further research.
|
7 |
Some Features of Tip Gap Flow Fields of a Linear Compressor CascadeTian, Qing 16 January 2004 (has links)
This thesis presents some results from an experimental study of three-dimensional turbulent tip gap flows in the linear cascade wind tunnel, for two different tip gap clearances (t/c=1.65% and 3.3%). The experiments focus on near-wall flow field measurements for the stationary wall and moving wall, and static pressure measurement on the low end-wall for the stationary wall case. The representative flows were pressure driven, three-dimensional turbulent boundary layers in the linear cascade tunnel for the stationary wall case, and the combination of the pressure driven and shear driven flow for the moving wall case.
Several experimental techniques are used in the studies: a three-orthogonal-velocity-component fiber-optic laser Doppler anemometer (3D-LDA) system, surface oil flow visualization, and a scanivalve system for static pressure measurement through pressure ports on the end-wall. From the details of the oil flow visualization pattern on the end-wall, some features of the passage flow, cross flow, and the tip leakage vortex in this cascade flow were captured. Oil flow visualization on the blade surface reveals the reattachment of the tip leakage vortex on the blade surface. The static pressure results on the lower end-wall and mid-span of the blade show huge pressure drop on the lower end-wall from the pressure side to the suction side of the blade and from mid-span to the lower end wall. The end-wall skin friction velocity is calculated from near-wall LDA data and pressure gradient data using the near-wall momentum equation.
The statistics of Reynolds stresses and triple products in two-dimensional turbulent boundary layer and three-dimensional turbulent boundary layer was examined using a velocity fluctuation octant analysis in three different coordinates (the wall collateral coordinates, the mid tip gap coordinates, and the local mean flow angle coordinates). The velocity fluctuation octant analysis for the two-dimensional turbulent boundary layer reveals that ejections of the low speed streaks outward from the wall and the sweeps of high speed streaks inward toward the wall are the dominant coherent motions. The octant analysis for the three-dimensional turbulent boundary layer in the tip gap shows that the dominant octant events are partially different from those in the two-dimensional turbulent boundary layer, but ejection and sweep motions are still the dominant coherent motions. For the three-dimensional turbulent boundary layer in the moving wall flow, the near-wall shear flow reinforces the sweep motion to the moving wall and weakens the out-ward ejection motion in the shear flow dominant region. Between the passage flow and the shear flow, is the interaction region of the high speed streaks and the low speed streaks. This is the first time that the coherent structure of the three-dimensional turbulent boundary in the linear cascade tip gap has been studied. / Master of Science
|
8 |
Efficient Volvo Bus Cooling System,Using Electrical Fans : A comparison between hydraulic and electrical fansFernandes, Rita January 2014 (has links)
Economical and environmental factors together with energy policies towards more efficient systemsare the driving force for the development of the vehicle industry. Significant changes have beenmade to fulfill new emissions legislation but the basic internal combustion vehicle architecture hasbeen kept. New emission treatment systems that increase the thermal loading of the cooling systemhad been added within the same package envelope as before, which means less space to place coolingfans and a greater need for airflow. Changes in the cooling system, namely the replacement of thehydraulic fan drive system by electrical fans is one of the energy efficient alternatives for severalcity buses under certain environments, like the ”typical red city buses”, well-known in the UnitedKingdom. In this thesis study, hydraulic fans are compared with electrical fans and a road-mapof the benefits and drawbacks of the two systems is developed, based on real traffic performanceperformance data and the results of existing simulations and tests. In addition, new simulations arepresented in order to find the most efficient design for the cooling system as well as a comparisonof these results with previous ones. This road map will be used later by Volvo-Buses Group as atool to better understand in which circumstances electrical fans can be beneficial, in terms of fuelconsumption, noise production, cooling performance, control of the fans and associated costs.
|
9 |
Modelling Gas Flow Behaviour in Gas AtomizerVasanthasenan Reji, Aravind Senan January 2022 (has links)
Gas atomization is regarded as a reliable method for creating high-quality metal powders from molten metal. The liquid metal is fed into the chamber as a free-falling stream through a nozzle, where it is impinged by high-velocity gas jets, causing degeneration and production of metal droplets, which solidify to create metal powders. As the metal droplets fall lower towards the collection hoopers, the solidification process begins. As a result, having a strong handle on the process parameters helps to produce metal powders that are fine, spheroidized, and have good characteristics. A free fall atomizer with twelve discrete nozzles, having a cylindrical internal profile, arranged in two different levels has been employed to introduce high-velocity gas jets into the chamber, for the current study. A cross-sectional sketch created by Uddeholm AB provided the geometric dimensions, and CFD was used to generate a simulation experiment for the system. Fluent setup input values were derived from literature data. The primary objective of the study is to analyze the influence of varying inlet pressure and the number of discrete gas jet nozzles, on the flow behavior of the atomizing gas. Additionally, the Discrete Phase Model approach was adopted to study the interaction of particles with the gas flow. The simulation model was validated by carrying out the visualization experiment, Schlieren imaging. From the study, it was realized that the results of the numerical model showed a mismatch relative to the experimental value. This can be attributed to the discretization technique, input parameters and the numerical model employed in this study. However, the parametric study provided a qualitative analysis regarding the influence of input parameters on flow behavior. It was studied that with increasing the inlet pressure and number of discrete nozzles there is a subsequent increase in the maximum velocity attained by the atomizing gas, resulting in a decrease in velocity of melt introduced into the system. Additionally, a radial pressure gradient was observed to be present that increased in accordance with the parameters, resulting in reduction of the melt film thickness produced during pre-filming mechanism. However, the Discrete Phase Model provided evidence that with increment in the gas to melt ratio, the number of particles that get dispersed to make collision with the domain wall increased. Thus, a subsequent increase in downstream velocity was required to maintain the particles within the domain walls as the study parameters were increased. / Gasatomisering betraktas vara en tillförlitlig metod för att skapa högkvalitativt metallpulver från smält metall. Den flytande metallen matas in i en kammare som en fri fallande ström genom ett munstycke, där den trycks in av höghastighetsstrålar. Vilket skapar en degeneration och en bildandet av metalldroppar som stelnar till att metallpulver kan skapas. Stelningsprocessen börjar när metalldropparna faller emot uppsamlingsbågarna. Ett fint och sfärisk metall metallpulver med goda egenskaper kan produceras genom att ha en god kontroll på processparametrarna. I denna studie har en ”Free Fall Atomizer” med tolv diskreta munstycken med en cylindrisk profil arrangerade i två olika nivåer använts för att introducera höghastighetsstrålar i kammaren. De geometriska dimensionerna var försedda från en ritning i tvärsnitt skapad av Uddeholms AB och samt användes en CFD för att generera ett simulationsexperiment av systemet. Ingångsvärden för inställningarna av flödena härleddes från litteraturdata. Huvudsyftet med studien var att studera flödesbeteendet av den atomiserande gasen genom att analysera inflytandet av att variera ingångstrycket och antalet diskreta gasstrålmunstycken. Dessutom togs det till en diskret fasmodell för att studera partiklarnas interaktion med gasflödet. Simulationsmodellen validerades genom att utföra ett visualiseringsexperiment genom Schlierenfotografering. Det framgick i studien att den numeriska modellens resultat inte stämde överens med det experimentella värdet. Detta kan attribueras till diskretiseringstekniken, inmatningsparametrarna och den numeriska modellen som användes i studien. Hur som helst försedde den parametriska studien en kvalitativ analys angående inflytandet av inmatningsparametrarna på flödesbeteendet. Det framgick att en ökning av ingångstrycket och av antalet av diskreta munstycken gav en påföljande ökning i den maximala hastigheten som den atomiserande gasen kan erhålla. Vilket resulterar till en sänkning av hastigheten av smältan som introduceras till systemet. Dessutom observerades en radiell tryckgradient vara närvarande som ökade i enlighet med parametrarna. Det resulterade i en reduktion av smältfilmtjockleken som producerades under förfilmingsmekaniskmen. Trots det visade den diskreta fasmodellen att en ökning av gas till smältförhållandet också ökade antalet partiklar som sprids vidare för att kollidera med domänväggen. Således krävdes en påföljande ökning av nedströmningshastigheten för att bibehålla partiklarna inom domänväggar när studiens parametrar ökade.
|
10 |
Measurement Of Static Pressure Over Bodies In Hypersonic Shock Tunnel Using MEMS-Based Pressure Sensor ArrayRam, S N 12 1900 (has links) (PDF)
Hypersonic flow is both fascinating and intriguing mainly because of presence of strong entropy and viscous interactions in the flow field. Notwithstanding the tremendous advancements in numerical modeling in the last decade separated hypersonic flow still remains an area where considerable differences are observed between experiments and numerical results. Lack of reliable data base of surface static pressures with good spatial resolution in hypersonic separated flow field is one of the main motivations for the present study.
The experiments in hypersonic shock tunnels has an advantage compared to wind tunnels for simulating the total energy content of the flow in addition to the Mach and Reynolds numbers. However the useful test time in shock tunnels is of the order of few milliseconds. Hence in shock tunnel experiments it is essential to have pressure measurement devices which has special features such as small in size, faster response time and the sensors in array form with improved spatial resolutions. Micro Electro Mechanical Systems (MEMS) is an emerging technology, which holds lot of promise in these types of applications. In view of the above requirement, MEMS based pressure sensor array was developed to measure the static pressure distribution.
The study is comprised of two parts: one is on the development of MEMS based pressure sensor array, which can be used for hypersonic application and other is on experimental static pressure measurement using MEMS based sensors in separated hypersonic flow over a backward facing step model.
Initially a static pressure sensor array with 25 sensors was developed. The static calibration of sensor array was carried out to characterize the sensor array for various characteristic parameters. The preliminary experimental study with cluster of 25 MEMS sensor array mounted on the flat plate did not provide reliable and repeatable results, but gave valuable inputs on the typical problems of using MEMS sensors in short duration hypersonic ground test facilities like shock tunnels. Incidentally, to the best of our knowledge this is first report on use of MEMS based pressure sensors in hypersonic shock tunnel. Later cluster of 5 sensor array was developed with improved electronic packaging and surface finish. The experiments were conducted with flat plate by mounting 5 sensor array shows good agreement in static pressure measurement compared with standard sensors.
In the second part of the study a backward facing step model, which simulates the typical gasdynamic flow features associated with hypersonic flow separation is designed. Backward facing step model with step height of 3 mm was mounted with sensor array along the length of model. Just after the step, static pressure measurements were carried out with MEMS sensors. It is important to note that, in the space available in backward facing step model we could mount only one conventional Kulite pressure transducer. The experiments were conducted at Mach number of 6.3 and at stagnation enthalpy of 1.5 MJ/kg in hypersonic shock tunnel (HST-5) at IISc. Based on the static pressure measurement on backward facing step, the location of separation and reattachment points were clearly identified. The static pressure values show that reattachment of flow takes place at about 7 step heights. Numerical simulations were carried out using commercial CFD code, FLUENT for flat plate and backward facing step models to compliment the experiments. The experimental tests results match well with the illustrative numerical simulations results.
|
Page generated in 0.1019 seconds