11 |
Development of an assured systems management model for environmental decision–making / Jacobus Johannes Petrus VivierVivier, Jacobus Johannes Petrus January 2011 (has links)
The purpose of this study was to make a contribution towards decision–making in complex
environmental problems, especially where data is limited and associated with a high degree of
uncertainty. As a young scientist, I understood the value of science as a measuring and
quantification tool and used to intuitively believe that science was exact and could provide
undisputable answers.
It was in 1997, during the Safety Assessments done at the Vaalputs National Radioactive
Waste Repository that my belief system was challenged. This occurred after there were
numerous scientific studies done on the site that was started since the early 1980’s, yet with
no conclusion as to how safe the site is in terms of radioactive waste disposal. The Safety
Assessment process was developed by the International Atomic Energy Agency (IAEA) to
transform the scientific investigations and data into decision–making information for the
purposes of radioactive waste management.
It was also during the Vaalputs investigations when I learned the value of lateral thinking.
There were numerous scientists with doctorate and master’s degrees that worked on the site of
which I was one. One of the important requirements was to measure evaporation at the local
weather station close to the repository. It was specifically important to measure evaporation as
a controlling parameter in the unsaturated zone models. Evaporation was measured with an Apan
that is filled with water so that the losses can be measured. Vaalputs is a very dry place
and water is scarce. The local weather station site was fenced off, but there was a problem in
that the aardvark dug below the fence and drank the water in the A–pan, so that no
measurements were possible. The solution from the scientists was to put the fence deeper into
the ground. The aardvark did not find it hard to dig even deeper. The next solution was to put
a second fence around the weather station and again the aardvark dug below it to drink the
water. It was then that Mr Robbie Schoeman, a technician became aware of the problem and
put a drinking water container outside the weather station fence for the aardvark and – the
problem was solved at a fraction of the cost of the previous complex solutions.
I get in contact with the same thinking patterns that intuitively expect that the act of scientific
investigations will provide decision–making information or even solve the problem. If the
investigation provides more questions than answers, the quest is for more and more data on
more detailed scales. There is a difference between problem characterization and solution viidentification.
Problem characterization requires scientific and critical thinking, which is an
important component but that has to be incorporated with the solution identification process
of creative thinking towards decision–making.
I am a scientist by heart, but it was necessary to realise that apart from research, practical
science must feed into a higher process, such as decision–making to be able to make a
practical difference.
The process of compilation of this thesis meant a lot to me as I initially thought of doing a
PhD and then it changed me, especially in the way I think. This was a life changing process,
which is good. As Jesus said in Mathew 3:2 And saying, Repent (think differently; change
your mind, regretting your sins and changing your conduct), for the kingdom of heaven is at
hand. / Thesis (Ph.D. (Geography and Environmental Studies))--North-West University, Potchefstroom Campus, 2011.
|
12 |
Charge pumps and floating gate devices for switching applicationsMabuza, Bongani Christopher 27 November 2012 (has links)
On-chip impedance tuning is used to overcome IC perturbations caused by packaging stress. Tuning is more important for matching networks of radio frequency (RF) systems. Possible package resonance and fabrication process variations may cause instability, which is a major problem in RF systems. Thus, precautions need to be taken in order to maintain the overall stability of components and the final system itself. Electrically erasable programmable read-only memory switches (EEPROMs) occupy less die area compared to e-fuses and microelectromechanical system (MEMS) switches, thus EEPROMs are proposed to be used as tuning switches in millimetre-wave (mm-wave) applications. It is anticipated that EEPROM switches will also enable multi-time programming because of the smaller area and the fact that more switches can be used for fine-tuning. The problem addressed in this research is how suitable EEPROMs are for switching applications in the mm-wave region. The main focus of this dissertation is to characterise the suitability of EEPROM switches qualitatively for tuning with systems operating in the mm-wave spectrum. 130 nm SiGe BiCMOS IBM 8HP process technology was used for simulation and the fabricated prototypes. The Dickson charge pump (CP), two voltage doubler CPs and four floating gate (FG) devices were investigated. Literature and theoretical verification was done using computer aided design (CAD) Cadence software through circuit analysis and the layouts were also designed for integrated circuit (IC) prototype fabrication. The qualitative evaluation of the hypothesis was based on investigating reliability issues, switching characteristics, CP output drive capability and mm-wave characterisation. The maximum measured drain current for FGs was 1.4 mA, 2.7 mA and 3 mA for devices 2, 3 and 4, respectively. The ratio between ON state switching current (after tunnelling) and OFF state switching current (after injection) was 1.5, 1.35 and 6 for devices 2, 3 and 4, respectively. The ratios correlated with the expected results in terms of FG transistor area: a high area results in a higher ratio. Despite the correlation, devices 2 and 3 may be unsuitable because the ratio is less than 2: a smaller ratio between the ON and OFF states could also result in higher losses. The Dickson CP achieved an output voltage of 2.96 V from an input of 1.2 V compared to 3.08 V as computed from the theoretical analysis and 4.5 V from the simulation results. The prototypes of the voltage doubler CP did not perform as expected: a maximum of 1 V was achieved compared to 4.1 – 5 V as in the simulation results. The suitability of FG devices for switching applications depends on the ratio of the ON and OFF states (associated to insertion and isolation losses): the larger the FG transistor area, the higher the ratio. The reliability issues are dominated by the oxide thickness of the transistor, which contributes to charge leakages and charge trapping: smaller transistor length causes more uncertainties. Charge trapping in the oxide increases the probability of leakages and substrate conduction, thus introduces more losses. Based on the findings of this research work, the FG devices promise to be suitable for mm-wave switching applications and there is a need for further research investigation to characterise the devices in the mm-wave region fully. AFRIKAANS : Impedansie-instelling op skyf word gebruik om steurings in geïntegreerde stroombane wat deur verpakkingstres veroorsaak word, te oorkom. Instelling is meer belangrik om netwerke van radiofrekwensiesisteme te paar. Moontlike verpakkingresonansie en variasies in die vervaardigingsproses kan onstabiliteit veroorsaak, wat ‟n groot probleem is in radiofrekwensiesisteme. Voorsorg moet dus getref word om die oorhoofse stabiliteit van komponente en die finale sisteem self te handhaaf. Elektries uitveebare programmeerbare slegs-lees-geheueskakelaars (EEPROMs) neem minder matrysarea op as e-sekerings en die sekerings van mikro-elektromeganiese sisteme en word dus voorgestel vir gebruik as instellingskakelaars in millimetergolfaanwendings. Daar word verwag dat EEPROM-skakelaars ook multi-tydprogrammering sal moontlik maak as gevolg van die kleiner area en die feit dat meer skakelaars gebruik kan word vir fyn instellings. Die probleem wat in hierdie navorsing aandag geniet, is die geskiktheid van EEPROMS vir skakelaanwendings in die millimetergolfstreek. The hooffokus van die verhandeling is om die geskiktheid van EEPROM-skakelaars kwalitatief te karakteriseer vir instelling met sisteme wat in die millimetergolfspektrum funksioneer. Department of Electrical, Electronic and Computer Engineering v University of Pretoria 130 nm SiGe BiCMOS IBM 8HP-prosestegnologie is gebruik vir simulasie en die vervaardigde prototipes. Die Dickson-laaipomp is gebruik vir simulasie en die vervaardigde prototipes. Die Dickson-laaipomp, twee spanningverdubbelinglaaipompe en vier swewendehektoestelle is ondersoek. Literatuur- en teoretiese verifikasie is gedoen met behulp van rekenaarondersteunde-ontwerp (CAD) Cadence-sagteware deur stroombaananalise en die uitleg is ook ontwerp vir die vervaardiging van geïntegreerdestroombaanprototipes. Die kwalitatiewe evaluasie van die hipotese is gebaseer op die ondersoek van betroubaarheidkwessies, skakelingeienskappe, laaipompuitsetdryfvermoë en millimetergolfkarakterisering. Die maksimum gemete dreineerstroom vir swewende hekke was 1.4 mA, 2.7 mA en 3 mA vir onderskeidelik toestelle 2, 3 en 4. Die verhouding tussen die AAN-toestand van die skakelstroom (na tonnelling) en die AF-toestand van die skakelstroom (na inspuiting) was 1.5, 1.35 en 6 vir toestelle 2, 3 en 4, onderskeidelik. Die verhoudings het ooreengestem met die verwagte resultate rakende die swewendehek-transistorareas: ‟n groot area het ‟n hoër verhouding tot gevolg. Nieteenstaande die ooreenstemming, mag toestelle 2 en 3 moontlik nie geskik wees nie, omdat die verhouding kleiner as 2 is: ‟n kleiner verhouding tussen die AAN- en AF-toestande mag ook hoër verliese tot gevolg hê. Die Dickson-laaipomp het ‟n uitsetspanning van 2.96 V vanaf ‟n inset van 1.2 V vergeleke met 3.08 V soos bereken volgens die teoretiese analise en 4.5 V volgens die simulasieresultate. Die prototipes van die spanningverdubbelinglaaipomp het nie gefunksioneer soos verwag is nie: ‟n maksimum van 1 V is bereik vergeleke met 4.1 – 5 V soos in die simulasieresultate. Die geskiktheid van swewendehektoestelle vir skakelingtoepassings hang af van die verhouding van die AAN- en AF-toestande (wat met invoer-en isolasieverlies geassosieer word): hoe groter die swewendehektransistorarea, hoe hoër die verhouding. Die betroubaarheidkwessies word oorheers deur die oksieddikte van die transistor, wat bydra tot ladinglekkasies en ladingvasvangs: korter transistorlengte veroorsaak meer onsekerheid. Ladingvasvangs in die oksied verhoog die moontlikheid van lekkasies en substraatgeleiding en veroorsaak dus groter verlies. Die bevindings van hierdie navorsing toon dat swewendehektoestelle waarskynlik geskik is vir millimetergolfaanwendings en verdere navorsing is nodig om die toestelle volledig in die millimetergolfstreek te karakteriseer. Copyright / Dissertation (MEng)--University of Pretoria, 2013. / Electrical, Electronic and Computer Engineering / unrestricted
|
Page generated in 0.0796 seconds