• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 5
  • 2
  • Tagged with
  • 12
  • 12
  • 12
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Directly Measuring the Adhesive and Elastic Properties of Bacteria using a Surface Force Apparatus

Heo, Cheol Ho January 2006 (has links)
Bacterial adhesion is the first step of biofilm formation that plays various roles in the environment and the human body. Examples of undesirable roles of biofilm formation include metal rust, sewage sludge and bacteria-related diseases. Desirable roles are biofiltration and bioremediation.For a decade, Atomic Force Microscopy (AFM) has been the primary tool used to study the adhesion and elastic properties of individual bacteria. In this work we show it is possible to use a Surface Forces Apparatus (SFA) to measure elastic and adhesive properties of small collections of surface bound bacteria. The measurements are conducted with incomplete, patterned bacterial films and we have developed a protocol to image the contact area with AFM after the experiment. Using the SFA, we measured the force profile between a P. Aeruginosa PAO1 film and a bare mica surface. We repeated the measurement in the same contact position for up to ten days to determine the effect of desiccation on the film material properties, and then moved to the new contact area to measure the film thickness and elastic properties. A large shrinkage of the bacterial film thickness was measured during the first few days due to the bacterial film desiccation and rearrangement. The proportion of shrinkage depends on factors such as the bacterial film coverage, roughness, temperature and relative humidity. Thickness compressibility was estimated from the force curves. As a force approximation, the stress at the center of the contact (σ) and the area of the contact were estimated by applying the Hertz model. Since the film is incomplete the calculated area in contact was reduced by a factor estimated from the optical image of the contact zone. Adhesiveness was measured in receding force profiles. Maximum adhesive force was detected in the first day, due to the high capillary force, decreased by the bacterial film desiccation and increased again due to the conditioning film.
2

Inverse analysis of the structures of the liquid molecules and colloidal particles near the solid-liquid interfaces: the relation between the number density distribution and the experimental force curve / 固液界面における液体分子とコロイド粒子の構造の逆解析:数密度分布と実験のフォースカーブの関係

Hashimoto, Kota 23 March 2021 (has links)
京都大学 / 新制・課程博士 / 博士(工学) / 甲第23217号 / 工博第4861号 / 新制||工||1759(附属図書館) / 京都大学大学院工学研究科物質エネルギー化学専攻 / (主査)教授 作花 哲夫, 教授 安部 武志, 教授 佐藤 啓文 / 学位規則第4条第1項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DGAM
3

Investigating sub-10 nm-thick Cloaking Films on Sessile Water Droplets Placed on Slippery Lubricant-Infused Porous Surfaces (SLIPS)

Ridwan, Muhammad Ghifari 04 1900 (has links)
Slippery liquid-infused porous surfaces (SLIPS) – a new class of bio-inspired liquid-repellent surfaces – comprise arbitrarily porous architectures filled with oils that exhibit high interfacial tensions to probe liquids and present ultralow contact angle hysteresis (<〖10〗^°). However, before practical technologies based on SLIPS can be designed at large-scale, a number of fundamental questions remain to be answered. For instance, depending on the sign of the spreading coefficient of the Vapor(V)-lubricant oil(O)-liquid(L) system, defined as S_(OL(V))=γ_LV-γ_LO-γ_OV>0, the lubricating layer forms a layer at the liquid-vapor interface (here, γ_LV is a liquid-vapor interfacial tension, γ_LO – liquid-oil, and γ_OV – oil-vapor). This “cloaking” of liquid drops can deplete SLIPS’ lubricant over time and contaminate the probed liquid. So far, cloaking has been investigated by contact angle goniometry and confocal microscopy, which cannot resolve films of molecular thickness and factors that govern the equilibrium thickness of those films are not entirely clear. Here, we report on the development and application of a reflective-mode SFA platform to characterize the cloaking of water droplets placed on SLIPS. A multilayer matrix method is utilized to analyze the interferometry data. Using this complementary experimental and analytical approach, we determined the thickness of the cloaking layer for the FDTS(solid)-VF-40(lubricant)-water(probe liquid)-air system to be z3= 7±1 nm. Towards deeper insights into the intermolecular and surface forces responsible for cloaking, we demonstrate that repulsive van der Waals interactions are responsible for stabilizing the cloaking film at the water-air interface. Our experimental platform and the analytical framework should facilitate investigations of other SLIPS and probe liquid systems down to the molecular-scale resolution. These findings might aid the rational design of SLIPS, e.g., for drag reduction, anti-biofouling, and anti-corrosion. In addition to investigating SLIPS, We addressed the following questions with the help of atomic force microscopy (AFM): (i) how do zwitterionic osmolytes modulate electrostatic and hydrophobic interactions in nanoscale confinement, and (ii) is it possible to have two negatively charged surfaces attract each other? Our findings are presented as appendices in this thesis.
4

Etude des mécanismes de collage des microsystèmes lors de la phase de libération. Mise en oeuvre de moyens de prévention

Raccurt, Olivier 23 June 2004 (has links) (PDF)
Les microsystèmes regroupent sur un même substrat des fonctions électroniques, mécaniques, optiques, chimiques ou biologiques et sont fabriqués par les procédés de la microélectronique. Leurs particularités géométriques les rendent extrêmement sensibles aux forces de surfaces qui peuvent conduire à leur collage définitif, notamment lors de l'étape de libération. Cette thèse porte sur la compréhension de ce phénomène. Pour cela une mesure des forces d'adh´esions entre deux surfaces de silicium en milieu liquide a été entreprise à l'aide d'un appareil de mesure des forces de surface et à l'aide de microstructures. L'impact de la tension de surface de différents liquides sur l'adhésion a été étudié. L'étude de la rugosification du silicium par gravure humide, caractérisée par microscope à force atomique ; et l'impact cette rugosité sur l'adhésion a également été menée. Enfin, un procédé industriel original de libération par voie humide sans démouillage des substrats a été développé.
5

On the Adhesion Between Substrates Covered with Polyelectrolyte Multilayers

Lingström, Rikard January 2008 (has links)
This thesis examines the formation of Polyelectrolyte Multilayers (PEM) on cellulose fibres as a new way of influencing the fibre surface and the adhesion between wood fibres. The aim of the study was to enhance the fundamental understanding of the adsorption mechanisms behind the formation of Polyelectrolyte Multilayers on cellulose fibres; to study how the properties of the layers can be influenced and to show how the properties of the layers influence the adhesion between the fibres and the strength of paper sheets made from the PEM treated fibres. Different polyelectrolyte systems are known to form PEMs with different properties, and in this work two different polymer systems were extensively studied: poly(dimethyldiallylammonium chloride) (PDADMAC) / poly(styrene sulphonate) (PSS), which are both strong polylectrolytes (i.e. are highly charged over a wide range of pH) and poly allylaminehydrochloride (PAH) /poly acrylic acid (PAA), which are both weak polyelectorlytes (i.e. sensitive to pH changes). PEMs were also formed from PAH/ poly(3,4-ethylenedioxythiophene):PSS (PEDOT:PSS), in order to form electrically conducting PEMs on fibres and PEM-like structures were formed from polyethylene oxide (PEO) and polyacrylic acid (PAA). In order to study the influence of the PEM on adhesion and paper strength, fibres were treated and used to form sheets which were physically tested according to determine the tensile index and strain at break. Both these systems were studied using different molecular mass fractions. High molecular mass PDADMAC/PSS (&gt;500k/1000k) had a significantly greater influence as a function of the number of layers than low molecular mass PDADMAC/PSS (30k/80k). In contrast, sheets made from high molecular mass PAH/PAA (70k/240k) showed a significantly lower increase in strength than sheets made from low molecular PAH/PAA investigated earlier. Both these systems had a greater influence on paper strength when the cationic polyelectrolyte was adsorbed in the outermost layer. The amount of polyelectrolytes adsorbed on the fibres was determined using polylectrolyte titration (PET) and destructive analytical methods. Adsorption to model surfaces of silicon oxide was studied before the adsorption on fibres, in order to understand the influence on PEM properties of parameters such as salt concentration and adsorption time. Adhesion studies of surfaces coated with PAH/PAA using AFM, showed an increase in adhesion as a function of the number of adsorbed layers. The adhesion was higher when PAH was adsorbed in the outermost layers. Individual fibres were also partly treated using a Dynamic Contact Angle analyser (DCA) and were studied with regard to their wettability. In general, the wettability was lower when the cationic polymer was outermost. The level of adhesion and paper strength are discussed in terms of rigidity and wettability and the PEMs demonstrating a large number of free chain ends, a large chain mobility and a low wettability was found to have the greatest influence to adhesion and paper strength. / QC 20100823
6

Nanorhéologie de fluides complexes aux interfaces / Nanorheology of complex fluids at interfaces

Barraud, Chloé 06 July 2016 (has links)
Les liquides confinés présentent beaucoup de comportements fascinants, très différents de ceux qui sont observés dans leur volume. Le confinement peut induire un déplacement de l'équilibre des phases (par exemple de la transition liquide-vapeur, aussi appelé condensation capillaire), il peut modifier la température de transition vitreuses des polymères, ou bien imposer un ordre dans l'arrangement moléculaire du fluide. Les modifications des propriétés mécaniques des liquides aux interfaces sont particulièrement importantes au niveau des applications. Cependant au niveau de la compréhension, le simple cas des liquides newtoniens est toujours sujet à controverse, avec d'une part des simulations numériques montrant que la viscosité ne devrait pas être modifiée pour des confinements supérieurs à quelques tailles moléculaires, et d'autre part des expériences non unanimes, montrant parfois des modifications qualitatives des propriétés rhéologiques sous confinement. Récemment nous avons montré que les méthodes d'impédance hydrodynamique en géométrie sphère-plan constituent une méthode privilégiée, non-intrusive et non-ambigüe, pour aborder la nano-mécanique des liquides aux interfaces (1,2). S'agissant d'interphases, cad de couches fluides dont les propriétés sont modifiées par la proximité d'un solide, il est possible d'accéder à leur module sans contact, donc sans la perturbation apportée par une seconde surface. S'agissant de l'effet du confinement sur la rhéologie, nous avons montré que la déformation élastique à l'échelle du pico-mètre des surfaces confinantes, donne une forte modification de la rhéologie apparente du fluide, même en l'absence de tout effet intrinsèque. Le sujet de thèse vise à mettre en oeuvre les méthodes d'impédance hydrodynamique pour étudier la rhéologie de solutions de polymères confinés. On étudiera plus précisément deux systèmes modèles d'importance fondamentale aussi bien que pratique : les brosses de polymères greffés, dont les propriétés mécaniques sont un enjeu dans les applications de lubrification aussi bien que pour les écoulements biologiques, et les solutions de polymères hydro-solubles d'intérêt pour la récupération assistée du pétrole, en vue de comprendre les effets de fluidification sous confinement et de faire la part entre modification de la viscosité et couche de déplétion induite par l'écoulement. Au niveau instrumental, un des enjeux de la thèse sera de mettre en oeuvre les mesures d'impédance hydrodynamique sur deux types d'instruments complémentaires au niveau de l'échelle de la sonde: l'appareil de mesure de forces dynamique (SFA) du Liphy, et l'AFM à détection interférométrique développé à l'Institut Néel. Ces différentes échelles d'investigation devront permettre de préciser les propriétés moyennes mécaniques moyennes des liquides confinés et leurs gradients au voisinage de la paroi. Une perspective du travail sera de mettre en regard les propriétés mécaniques et rhéologiques intrinsèques des brosses polymères déterminées directement sur SFA ou AFM, avec leur propriétés fonctionnelles: propriétés de lubrification des contacts frottants, ou de modification des écoulements des dans micro-canaux. Ceci sera poursuivi sur la plateforme expérimentale mise en place par Lionel Bureau au Liphy : SFA de friction, systèmes micro-fluidiques à visée biomimétique (parois fonctionnalisées par des brosses polymères). L'enjeu sera alors de comprendre comment les propriétés mécaniques et rhéologiques des brosses déterminent celles des systèmes dans lesquels elles interviennent. / Liquids confined present many fascinating behaviors very different from those observed in their volume. Confinement can induce a shift in the balance of phases (eg the liquid-vapor transition, also called capillary condensation), it can change the glass transition temperature of the polymer, or impose order on the molecular arrangement of fluid. The changes in the mechanical properties of liquid interfaces are particularly important in applications. However the level of understanding, the simple case of Newtonian liquids is still controversial, with one hand, numerical simulations show that the viscosity should not be changed for some higher molecular sizes containment, and secondly non-unanimous experiences, sometimes showing qualitative changes in rheological properties under confinement. Recently we have shown that the methods of hydrodynamic impedance sphere-plane geometry is a privileged, non-intrusive method and unambiguous, to discuss the mechanics of nano-liquid interfaces (1,2). As interphase, ie fluid layers whose properties are modified by the proximity of a solid, it is possible to accede their contactless module, so without the disturbance caused by a second surface.S As regards the effect of confinement on the rheology, we have shown that the elastic deformation across the pico meter of confining surfaces, gives a strong modification beyond apparent rheology of the fluid, even in the absence of any intrinsic effect. The thesis aims to implement the hydrodynamic impedance methods to study the rheology of polymer solutions confined. We specifically consider two models of fundamental importance as well as practical systems: brushes grafted polymer whose mechanical properties are an issue in lubrication applications as well as for biological flows and solutions of water-soluble polymers interest in enhanced oil recovery, in order to understand the effects of thinning containment and to distinguish between changes in viscosity and depletion layer induced by the flow. At the instrumental level, one of the challenges of the thesis is to implement the hydrodynamic impedance measurements on two complementary instruments at the level of the probe: the measuring dynamic power (SFA) of Liphy, and AFM interferometric detection developed at the Institut Néel. These different scales of investigation will help to clarify the medium average mechanical properties of liquids confined and their gradients near the wall. A view of work will be to look mechanical and rheological properties of polymer brushes intrinsic determined directly on SFA or AFM with their functional properties: lubricating properties of sliding contacts, or modification of the flow in microchannels. This will continue on the implementation by Lionel Bureau Liphy experimental platform: SFA friction advised biomimetic micro-fluidic systems (walls functionalized polymer brushes). The challenge will be to understand how the mechanical and rheological properties of brushes determine those systems in which they operate.
7

Paysages énergétique et conformationnel d’interaction de la Synaptotagmin-1 avec des membranes / Energy and conformational landscape of Synaptotagmin-1 interacting with membranes

Gruget, Clémence 11 June 2018 (has links)
A l’arrivée d’un potentiel d’action au niveau d’une synapse neuronale, des ions calcium (Ca2+) pénètrent dans le neurone, permettant aux protéines SNAREs (N-ethylmaleimide-sensitive factor activating protein receptor) de s’assembler entièrement, engendrant la fusion des vésicules synaptiques contenant les neurotransmetteurs avec la membrane plasmique du neurone. Des protéines régulatrices telles que la Complexine et la Synaptotagmine sont étroitement couplées aux SNAREs et permettent une fusion rapide et synchrone. La Synaptotagmin-1 (Syt1), une protéine transmembranaire localisée sur les vésicules synaptiques, est le senseur calcique de la neurotransmission. Syt1 possède deux domaines de liaison au Ca2+, C2A et C2B, un domaine flexible reliant la région membranaire au C2A, ainsi qu’un court lien entre C2A et C2B. Il a été montré qu’une région polybasique dans le C2B se liait aux lipides anioniques tels que phosphatidylserine (PS) et phosphatidylinositol-4,5-bisphosphate (PIP2) en l’absence de Ca2+. A l’entrée du Ca2+, les ions Ca2+ se lient au C2A et au C2B. La liaison de Syt1 aux ions Ca2+ permet aux résidus non polaires à proximité des sites de liaison au Ca2+ de s’insérer dans la membrane. Si ces mécanismes sont relativement bien acceptés, les mécanismes biochimiques et biophysiques précis du déclenchement de la fusion induit par la liaison de Syt1 au Ca2+ restent flous. Dans ce travail, nous mesurons directement les interactions de Syt1 liée à une membrane avec des membranes anioniques comprenant des lipides PS et PIP2 par un appareil à force de surface (SFA), afin d’imiter la membrane d’une vésicule synaptique contenant Syt1 interagissant avec la membrane plasmique anionique. Nous réalisons une mutagénèse dirigée sur les sites de liaison au Ca2+ de C2A et C2B, ainsi que sur le site polybasique de C2B, pour entièrement cartographier les énergies de liaison à la membrane relatives à ces sites, à la fois en présence et en l’absence d’ions divalents. Nous trouvons que Syt1 se lie avec une énergie de ~6 kBT dans l’EGTA, ~10 kBT dans le Mg2+, et ~18 kBT dans le Ca2+. Des réarrangements moléculaires mesurés pendant le confinement de Syt1 entre les membranes prévalent dans le Ca2+ et dans le Mg2+, et suggèrent que Syt1 se lie initialement via le C2B puis réoriente ses domaines C2 dans la conformation de liaison privilégiée. La neutralisation des sites de liaison au Ca2+ de C2B engendre une réduction radicale de l’énergie de liaison de Syt1 dans le Ca2+, alors que la même mutation dans le C2A a un effet plus nuancé. Ces résultats éclairent sur la coopérativité de C2A et C2B dans leur liaison à la membrane, et montrent un rôle apparent prédominant de C2B. / Upon arrival of an action potential at the neuronal synapse, calcium ions (Ca2+) enter the neuron, allowing soluble N-ethylmaleimide-sensitive factor activating protein receptor (SNARE) proteins to fully zipper, leading to the fusion of pre-docked synaptic vesicles containing neurotransmitters with the plasma membrane of the neurone. Regulatory proteins such as Complexin and Synaptotagmin are closely coupled to SNAREs during synaptic vesicle fusion and lead to synchronous, fast fusion. Synaptotagmin-1 (Syt1) is a transmembrane protein found in synaptic vesicles and is the Ca2+ sensor for synaptic transmission. Syt1 has two Ca2+ binding domains, C2A and C2B, with a flexible linker domain from the membrane region to C2A, and a short linker between C2A and C2B. A polybasic patch in C2B has been shown to bind to anionic lipids such as phophidylserine (PS) and phosphisotinol (PIP2) in the absence of Ca2+. Upon Ca2+ influx, Ca2+ ions bind in C2A and C2B. Ca2+ binding to Syt1 allows non-polar residues nearby the Ca2+ binding sites to insert into the membrane. While these mechanisms are relatively well-accepted, the precise biochemical and biophysical mechanisms for the Syt1 Ca2+ trigger remain unclear. In this work, we directly measure the interactions of Syt1-coated membranes with anionic membranes including PS and PIP2 lipids by the surface forces apparatus (SFA) technique, in order to mimic a Syt1-coated synaptic vesicle membrane interacting with the anionic plasma membrane. We perform site directed mutagenesis of the Ca2+ binding sites of C2A and C2B, along with the polybasic patch in C2B, to fully map the site-binding energetics of Syt1 with membranes, both in the absence and presence of divalent ions. We find that Syt1 binds with ~6 kBT in EGTA, ~10 kBT in Mg2+, and ~18 kBT in Ca2+. Molecular rearrangements measured during confinement of Syt1 between membranes are more prevalent in Ca2+ and Mg2+ and suggest that Syt1 initially binds through C2B, then reorients the C2 domains into the preferred binding configuration. Neutralization of C2B Ca2+ binding site leads to a drastic decrease of Syt1 binding energy in Ca2+, while the same mutation in C2A has a milder effect. These results illuminate that C2A and C2B cooperate in membrane binding, with an apparent predominant role of C2B.
8

Caractérisation et utilisation de polymères en brosse pour la lubrification des tissus et des dispositifs médicaux

Pham, Duy Anh 08 1900 (has links)
La friction entre les surfaces mobiles de l’organisme peut être un problème difficile à résoudre, notamment dans les pathologies dégénératives comme l’arthrose ou la sécheresse oculaire. Malgré le développement de nombreux produits pharmaceutiques, les matériaux actuellement utilisés pour protéger les tissus blessés et les dispositifs biomédicaux contre l'usure par frottement sont encore limités dans leurs performances. Il existe un besoin urgent de matériaux injectables capables de protéger ces tissus et dispositifs afin de prolonger leur durée de vie et de traiter efficacement des maladies dégénératives. Parmi les innovations de la dernière décennie, les polymères à structure dite « en brosse » (BBs) se sont révélés prometteurs pour amoindrir les problèmes de friction et d'usure. Inspirés de l’architecture spécifique du protéoglycane 4, l'un des principaux composants lubrifiants du cartilage, les macromolécules BBs sont constituées d’un squelette linéaire et de chaînes latérales formant une brosse dense pouvant maintenir de l’eau sous une pression élevée. Les différentes structures des BBs, selon le squelette et leurs chaînes latérales, conduisent à plusieurs caractéristiques morphologiques et propriétés tribologiques intéressantes dans l’ingénierie tissulaire. Bien que leurs propriétés lubrifiantes aient été prouvées dans plusieurs études, les BBs n’ont à ce jour que peu d’applications. D’une part, la corrélation entre leur structure et leurs propriétés physicochimiques n’est pas encore clairement établie. D’autre part, il manque encore des études relatives à l’efficacité des BBs sur de vrais tissus. Pour pallier ce problème, notre projet vise à caractériser les propriétés physicochimiques et tribologiques des BBs sur différents types de surfaces en fonction de leur structure. La longueur du squelette, la densité de greffage et l’addition du groupe d’ancrage sont les 3 variables principales étudiées dans ce projet. La lubrification ainsi que d’autres propriétés importantes des BBs ont été évaluées sur les surfaces molles des cartilages, des yeux et des lentilles en contact. Les tests tribologiques ont été menés en utilisant un appareil à force de surface (SFA) via l’association du protocole classique et avancé qui l’adapte aux surfaces testées. A côté de la tribologie, l’affinité cinétique, la toxicité, les propriétés antisalissure et anti-inflammatoire des BBs sur les interfaces ont aussi été étudiées dans ce projet via les techniques de LigandTracer et de microscope fluorescent. / Friction between the body's moving surfaces can be a difficult problem to solve, particularly in degenerative pathologies such as osteoarthritis or dry eye. Despite the development of numerous pharmaceutical products, the materials currently used to protect injured tissues and biomedical devices against frictional wear are still limited in their performance. There is an urgent need for injectable materials capable of protecting these tissues and devices in order to extend their life and effectively treat degenerative diseases. Among the innovations of the last decade, polymers with a so-called "brush structure" (BBs) have shown promise in reducing friction and wear problems. Inspired by the specific architecture of proteoglycan 4, one of the main lubricating components of cartilage, BBs macromolecules consist of a linear backbone and side chains forming a dense brush capable of holding water under high pressure. The different structures of BBs, depending on the backbone and their side chains, lead to several morphological features and tribological properties of interest in tissue engineering. Although their lubricating properties have been proven in several studies, BBs have few applications to date. On the one hand, the correlation between their structure and physicochemical properties has not yet been clearly established. On the other hand, studies on the effectiveness of BBs on real tissues are still lacking. To overcome this problem, our project aims to characterize the physicochemical and tribological properties of BBs on different types of surfaces, depending on their structure. Backbone length, graft density and anchoring group are the 3 main variables studied in this project. Lubrication and other important properties of BBs were evaluated on the soft surfaces of cartilages, eyes and contact lenses. Tribological testing was carried out using a Surface Force Apparatus (SFA) via a combination of the classic and advanced protocol, adapting it to the surfaces tested. Alongside tribology, the kinetic affinity, toxicity, anti-fouling and anti-inflammatory properties of BBs on interfaces were also studied in this project via LigandTracer and fluorescent microscopy techniques.
9

Les forces de surface dynamiques pour l'investigation mécanique des surfaces molles / Dynamic surface forces for mechanical investigation of soft surfaces

Leroy, Samuel 03 December 2010 (has links)
Ce travail étudie comment la mesure des forces hydrodynamiques exercées par un liquide confiné entre une sphère et une surface d'intérêt permet de sonder à distance et sans contact les propriétés mécaniques de cette surface. Nous présentons tout d'abord le principe de cette technique originale de sonde fluide et la machine à forces de surface dynamique que nous utilisons pour mettre en œuvre ces expériences de nano-rhéologie. Puis nous nous intéressons à deux applications que nous avons plus particulièrement étudiées. D'une part, l'étude des propriétés de friction des bicouches lipidiques. Nous mettons en évidence une très faible friction mesurée sur certaines bicouches fluides et son potentiel rôle pour la bio-lubrification. D'autre part l'étude des propriétés élastiques de couche mince d'élastomère. Nous développons pour cela une théorie de l'élastohydrodynamique à géométrie sphère-plan en mode dynamique et présentons des résultats expérimentaux en très bon accord. Nous sommes capables de mesurer le module d'Young de films mince de PDMS d'épaisseur allant jusqu'à 600 nm. Enfin, nous présentons les développements instrumentaux réalisés pour optimiser les performances de la machine à forces de surfaces comme sonde fluide / This work addresses how the measurement of hydrodynamic forces of a liquid confined between a sphere and a surface of interest can lead to probe at a distance and without contact her mechanical properties. Firstly, we introduce this original technique of fluid probe and the dynamic Surface Force Apparatus used to perform these nanorheology experiments. Then, we present two applications for which the fluid probe can be of great importance. The first application is the study of friction properties of lipid bilayers. More particularly we measure very weak fluid friction coefficients on some fluid bilayers, which can be an important issue for biolubrication. The second application is the study of elastic properties of thin elastomer layers. For that we first develop an elasto-hydrodynamic theory for sphere-plan configuration in dynamic mode. Then, we present experimental results in very good agreement with this theory. We are able to measure the Young modulus of thin PDMS films of thickness as small as 600 nm. Finally, we present instrumental developments performed on the Surface Force Apparatus to optimize its potential as fluid probe
10

Nanorhéologie des liquides confimés : application à la nanomécanique des couches minces / Confined liquids nanorheology : application to thin films nanomechanics

Villey, Richard 05 December 2013 (has links)
Lorsque deux solides séparés par un liquide se rapprochent, le drainage s’accompagne de forces visqueuses normales aux parois. Si elles sont très rapprochées, de l’ordre de quelques nanomètres, les parois sont indentées par ces forces : c’est le "confinement élastique". Indenter un solide par un liquide permet de supprimer l’adhésion, qui limite la résolution en termes de module d’Young des tests classiques d’indentation par un solide, surtout pour les films supportés minces et mous, par exemple des élastomères d’épaisseur micrométrique. Or leurs propriétés, qui peuvent sensiblement différer des propriétés en volume, sont essentielles dans des domaines aussi variés que la microfluidique, l’électronique ou l’usure mécanique. Nous présentons les calculs qui relient les forces normales aux propriétés mécaniques du liquide et des parois lors d’un confinement élastique. Les résultats sont comparés à des expériences de nanorhéologie réalisées sur une machine à forces de surface très sensible. Cette sensibilité nous permet de montrer que l’effet du confinement élastique se manifeste même sans film mou déposé : cela implique que la rhéologie apparente d’un liquide confiné est toujours affectée par les déformations des parois, même très rigides.Nous montrons enfin que nous pouvons effectivement mesurer avec précision des modules d’Young autour du MPa dans des films d’élastomères de quelques centaines de nanomètres à quelques micromètres d’épaisseur. Si le module de stockage ne varie presque pas avec l’épaisseur, un module de pertes apparaît, augmentant sensiblement lorsque l’épaisseur diminue, témoignant d’une visco-élasticité que nous attribuons à la présence d’une couche interfaciale. / When two solids separated by a liquid layer are moving towards each other, the resulting drainage is associated with viscous forces normal to the walls. If these are very close to each other (several nanometers), they are indented by these forces : this is the notion of “elastic confinement”. Indenting a solid by a liquid solves the problem of adhesion, which limits the ability of classical indentationtests to provide accurate measurements on Young’s modulii. Adhesion is especially problematic for soft thin films, for example micrometric layers of elastomers, which mechanical properties can strongly differ from the bulk, but are of the highest importance in various fields such as microfluidics, electronics or mechanical wear. We present here the calculations which link the solid and liquid mechanical properties to the resulting forces in a liquid indentation test. The corresponding results are compared to nanorheology experiments using a very sensitive Surface Force Apparatus. Its sensitivity enables us to show that the elastic confinement is also measurable without any soft films, which implies that a confined liquid apparent rheology is always affected bythe deformations of even very rigid confining walls. Finally, we demonstrate that we are indeed able to measure precisely Young’s modulii in the MPa range for films as thin as several hundreds of nanometers. While the storage modulii are found to be almost independent ofthe film thicknesses, we identify the presence of loss modulii increasing with decreasing thicknesses. We attribute this unexpected viscoelastic behaviour to the presence of an interfacial layer.

Page generated in 0.0898 seconds