• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 43
  • 16
  • 14
  • 14
  • 13
  • 13
  • 11
  • 11
  • 9
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo comparativo da qualidade da água de chuva coletada em cobertura convencional e em telhado verde

Budel, Marcel Aramis 31 March 2014 (has links)
CAPES / O estudo consiste em uma comparação da qualidade da água da chuva coletada em duas formas distintas de captação: um sistema composto por um telhado inclinado com telhas de concreto, nomeada (casa 1) e o outro composto por uma cobertura plana com telhado verde, ou seja, vegetado, nomeada (casa 2). Tem por objetivo caracterizar os sistemas utilizados nas duas formas de cobertura, analisar a qualidade da água da chuva captada nos dois sistemas e fazer o acompanhamento da qualidade da água armazenada para posterior uso ao longo do estudo com o intuito de verificar a eficiência e comportamento dos sistemas de captação. Objetiva ainda encontrar relações nas variáveis envolvidas e apresentar os resultados de forma a estabelecer uma comparação qualitativa no desempenho das duas coberturas. O estudo foi realizado em duas casas localizadas na região noroeste da cidade de Curitiba, capital do Paraná. Na casa 1, com telhas de concreto, a água da chuva que escoa pelo telhado é primeiramente coletada por uma calha, seguindo por um duto vertical até o nível do solo, no qual se encontra um filtro simples, então a água é encaminhada para uma cisterna, onde é armazenada, para posterior uso na torneira externa para onde a água é bombeada. Já na casa 2, com cobertura plana vegetada, a água da chuva após passar pelo telhado verde é conduzida por dutos verticais até a cisterna de concreto no nível do solo, então uma eletrobomba recalca a água até um reservatório localizado na cobertura, acima do nível do telhado verde, para armazenamento e posterior uso na torneira externa. As amostras coletadas em nove eventos (17/05/2013 a 03/12/2013) foram analisadas quanto à: pH, turbidez, oxigênio dissolvido e temperatura, que foram medidos no próprio local. Demanda química de oxigênio (DQO), amônia, nitrito, nitrato e fosfato foram amostrados e analisados no laboratório de Saneamento da UTFPR, Campus Ecoville. Ainda quanto à presença de coliformes totais e termotolerantes (E. Coli), foram realizados em um laboratório terceirizado. Observou-se que o telhado convencional da casa 1 apresentou maior qualidade no parâmetro turbidez e demanda química de oxigênio (DQO), já o telhado verde diminuiu a acidez natural da água da chuva. As duas coberturas se mostraram eficientes pela concentração de amônia e nitrato, contudo indicaram concentrações elevadas de fosfato. Nos parâmetros microbiológicos os dois telhados não obtiveram qualidade suficiente para atender a NBR 15.527/2007. Desta forma, tomadas as devidas precauções, se recomenda o uso da água proveniente dos telhados, vegetados e convencional, para descargas de bacias sanitárias, irrigação de gramados e plantas ornamentais, lavagem de veículos, limpeza de calçadas e ruas, limpeza de pátios, espelhos d'água e usos industriais, conforme estabelecido na norma. / The study consists of a comparison of the quality of rainwater collected in two distinct ways of catchments: a system composed of a pitched roof with concrete tiles and another consisted of a vegetated flat coverage, as known as green roof. It aims to characterize the systems used in both forms of coverage, to analyze the quality of rainwater captured in the two systems and to monitor the quality of water stored for later use throughout the study in order to verify the efficiency and performance of catchment systems. It also aims to find relations in the involved variables and to present the results in order to establish a qualitative comparison in the performance of two coverages. The study was conducted in two houses located in the northwest region of the city of Curitiba, capital of Paraná. The appointee, house 1, has a pitched roof with concrete tiles, the rainwater that seeps through the roof is first collected by a trough, followed by a vertical duct to the ground level, with a simple filter, then the water is sent into a tank where it is stored for later use in the external faucet where the water is pumped. However, at house 2, with vegetated flat roof, after passing through the green roof the rainwater is driven by vertical ducts to the concrete tank at ground level, then an electric pump represses the water to a reservoir located on the roof, above the green roof ́s level for storage and later use on the external tap. Samples collected in nine events (17/05/2013 to 03/12/2013) were analyzed for pH, turbidity, dissolved oxygen and temperature, they were measured in situ. Chemical oxygen demand (COD), ammonia, nitrite, nitrate and phosphate were sampled and analyzed in the laboratory of Sanitation UTFPR Campus Ecoville. Nevertheless, for the presence of total and fecal coliforms (E. coli), tests were performed on an outsourced laboratory. As for the results obtained, the conventional roof house 1 rainwater had higher quality in turbidity and chemical oxygen demand (COD) parameter, whereas in house 2 the green roof reduced the natural acidity of rainwater. The two covers were effective in the concentration of ammonia and nitrate, though indicated high concentrations of phosphate. Microbiological parameters in neither roofs met the NBR 15.527/2007 quality. Thus, taken due precautions, it is recommend the use of water from roofs, vegetated and conventional, to flush toilets, to irrigate lawns and ornamental plants, to wash vehicles, to clean sidewalks and streets, to clean patios, water mirrors and to industrial uses, as defined in the standards.
42

Métodos de visão computacional aplicados a extração de características de ambientes urbanos em imagens de satélite de baixa resolução / Computer vision methods applied to extraction of characteristics of urban environments in low resolution satellite imagery

Almeida, Dyego de Oliveira 03 October 2018 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2018-11-05T18:46:12Z No. of bitstreams: 2 Dissertação - Dyego Oliveira Almeida - 2018.pdf: 32110237 bytes, checksum: 4d30b2227be666802bbb2e5437450fc2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-11-06T10:03:22Z (GMT) No. of bitstreams: 2 Dissertação - Dyego Oliveira Almeida - 2018.pdf: 32110237 bytes, checksum: 4d30b2227be666802bbb2e5437450fc2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-11-06T10:03:22Z (GMT). No. of bitstreams: 2 Dissertação - Dyego Oliveira Almeida - 2018.pdf: 32110237 bytes, checksum: 4d30b2227be666802bbb2e5437450fc2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-10-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The urban growth of the population and the deforestation of greenareas are one of the most critical problems currently in Brazil. Due to mobilization of rural people to the urban, high solar irradiation and the deforestation, the Government is creating sustainable actions sustainable in order to enlarge the green areas and permeable. In this perspective, to promote this mapping effectively in large areas necessary to the use of technologies of recognition of facial features. Low-resolution satellite imagery have low cost and great coverage area coverage, and therefore apply them in identifying features is advantageous over other types of images. However, to accomplish this identification is computationally complex due to the different features present in images of this type. This work proposes an effective method of digital processing of low resolution images in the identification of features, in particular the pertinent green aáreas with average accuracy of 80.5% and detection of buildings with an average accuracy of 63%. / O crescimento urbano da população e o desmatamento de áreas verdes são um dos problemas mais críticos atualmente no Brasil. Devido a mobilização da população rural para o âmbito urbano, elevação da irradiação solar e o desmatamento, o governo está criando ações sustentáveis a fim de ampliar as áreas verdes e permeáveis. Nesta perspectiva, para promover esse mapeamento de forma eficaz em grandes áreas se faz necessário o uso de tecnologias de reconhecimento de feições. Imagens de satélite de baixa resolução possuem baixo custo e grande abrangência de área, e portanto aplicá-las na identificação de feições é vantajoso em relação a outros tipos de imagens. No entanto, realizar essa identificação é computacionalmente complexo devido as diferentes características existentes em imagens desse tipo. Este trabalho propõe um método eficaz de processamento digital de imagens de baixa resolução na identificação de feições, em particular as pertinentes a áreas verdes com acurácia média de 80,5% e detecção de edificações com precisão média de 63%.
43

Avaliação do desempenho do sistema de descarte de água de chuva coletada em coberturas de três diferentes tipos de materiais / Performance assessment of disposal units from Rainfal collection system from roofs made by three different materials

ROCHA, Bárbara Cristina Castro de Melo 20 May 2010 (has links)
Made available in DSpace on 2014-07-29T15:01:53Z (GMT). No. of bitstreams: 1 barbara cristina castro.pdf: 4909158 bytes, checksum: 97c33d72b85f6014d478bd8aea66f69b (MD5) Previous issue date: 2010-05-20 / The water shortage has become one of the world's main problems, leading to the development of new technologies and practices of water conservation. In order to obtain more effective solutions to solve this problem, new researches have been carried on to create hydraulic and sanitary systems more sustainable or, at least, system that causes less impact to the environment. Among the technologies economically available on water conservation in buildings, the use of rainfall collected from roofs can be of great potential to become a viable solution. The objective of this work is to study the ideal conditions for the disposal process of rainfall collected from three roofs made of different materials: metal, asbestos cement and ceramic tiles, located nearby, with the purpose of identifying both the ideal volume of disposal and the achievement of water quality standards, so that it becomes feasible for future uses. To do so, experimental units were installed to collect, dispose and store rainwater from three buildings located within the area of the School of Civil Engineering at Federal University of Goiás. After monitoring the volume of disposal correlating it with the quality assessment of the rainwater collected in each type of roof and with the rainwater collected directly from the atmosphere, the processes were evaluated based on the observed parameters and on the criteria established by the NBR 15,527 (ABNT, 2007), in order to identify the best way to implement disposal units in rainwater usage systems in buildings. It had been found that the rainwater disposal process is essential for obtaining water with better quality from these systems. It had also been observed that the disposal based on time does not seem to be securely enough to guarantee the necessarily quality in the collected water. Among the roofs in study, the metal roof gave water with the best quality after the disposal of the first 100 liters collected (this corresponds to 1,33 mm of accumulated rainfall in the area of study). It is presumed that the metal roof is the best choice to collect rainfall water because it is smoother and has almost no overlapping tiles. On the other hand, the 2 mm rainwater disposal suggested by NBR 15,527 (ABNT, 2007) has shown to be insufficient to guarantee the safe and secure use of the collected water to both users and hydraulic installations, requiring for this purpose the installation of at least a simplified water treatment unit. / A escassez de água tem se tornado um dos grandes problemas mundiais, o que vem levando a necessidade de estudos de novas metodologias e técnicas de conservação de água. Visando a obtenção de soluções eficazes para minimizar esse problema, dentro do ambiente construído, vários estudos estão sendo realizados em busca de sistemas prediais hidráulicos e sanitários mais sustentáveis ou que promovam menor impacto ambiental. Dentre as possíveis tecnologias que visam à conservação de água em edificações, os sistemas de aproveitamento de águas de chuva podem ser uma alternativa viável e de grande potencial para a solução desse problema. O objetivo deste trabalho consiste em estudar as condições ideais do processo de descarte da água da chuva coletadas em três coberturas de diferentes tipos de materiais: metálico, cimento amianto e barro, situadas em uma mesma localidade, visando identificar o volume ideal de descarte e padrões de qualidade de água que viabilizem sua posterior utilização. Para tanto, foram instaladas unidades experimentais de captação, descarte e armazenamento de água de chuva em três edificações na área da Escola de Engenharia Civil da Universidade Federal de Goiás. Após o monitoramento do volume de descarte correlacionado com a avaliação da qualidade da água de chuva coletada em cada tipo de cobertura e, com a água de chuva coletada diretamente da atmosfera, foram avaliados os processos com base nos parâmetros observados e nos critérios estabelecidos pela NBR 15.527 (ABNT, 2007), de forma a identificar a melhor forma de viabilizar a implantação de unidades de descarte em sistemas de aproveitamento de água de chuva em edificações. Foi verificado que o processo de descarte de água de chuva é essencial para a obtenção de água de melhor qualidade nestes sistemas. Também foi possível observar que o descarte por tempo não se mostrou suficiente para garantir a captação de água de chuva de qualidade assegurada. Dentre os telhados avaliados, a cobertura de telhas metálicas proporcionou a obtenção de uma água de melhor qualidade após o descarte dos primeiros 100 litros coletados (correspondente a 1,33 mm de chuva para as áreas de contribuição estudadas). Presume-se que este resultado tenha sido obtido devido a sua superfície de contato ser mais lisa que os outros telhados estudados e, também de não haver sobreposição de telhas. Por outro lado, os 2 mm de descarte de água de chuva, sugeridos pela NBR 15.527 (ABNT, 2007), não se mostraram suficientes para garantir que a água de chuva coletada possa ser utilizada sem que haja risco aos usuários e às instalações hidráulicas, exigindo para tanto ao menos um tratamento simplificado.

Page generated in 0.0349 seconds