1 |
The Fc Orth (SA) final examination The short-term outcome of hip revision arthroplasty with Trabecular Metal™ components and augmentsNoconjo, Lubabalo 15 September 2021 (has links)
Background: Highly porous Trabecular Metal™ acetabular components are increasingly being used in revision hip arthroplasty as they facilitate ingrowth, provide a useful mechanism to deal with bone loss and may decrease the risk of infection. The purpose of this audit was to describe: 1) the short-term radiological outcomes of revision hip arthroplasty with Trabecular Metal™ components and augments. 2) the total number of hip arthroplasty surgeries over five years, and indications for revision. Methods: A retrospective folder and radiograph review of all patients who had revision total hip arthroplasty (THA) at a tertiary level hospital from February 2012 to February 2017 was done. Results: There were 979 THAs performed over the period – 863 (87%) primary THAs, and 116 (12%) hip revision cases performed in 107 patients. Of the 116 (107 patients) hip revisions, there were seven (6%) re-revisions in five patients. Trabecular Metal™ was used for revision in 16 hips (14 patients), which is 13.7% of the total 116 revisions. There were ten females and four males with an average age of 61 years. The average duration of follow-up in this group was 18.5 months (1.5– 39.2). In these 16 Trabecular Metal™ hips, there were three (18.7%) early failures of fixation due to technical errors. The indications for revision were aseptic loosening 67 (58.6%), septic loosening 11 (9.5%), liner wear 18 (15.5%), periprosthetic fracture five (4.3%), other 15 (13%). Conclusion: In our institution, Trabecular Metal™ revisions had a 18.7% early failure rate due to technical error. 12% of the arthroplasty is revision surgery. The indications for revision are similar to published literature.
|
2 |
Total knee arthroplasty : aspects on improved fixation in the younger patientHenricson, Anders January 2008 (has links)
The results of total knee arthroplasty are inferior in younger patients. The challenge today is therefore to develop designs and concepts that will last at least 25 years. This thesis has evaluated the fixation to bone of modern designs of knee prostheses uring RSA analysis. Coating implant surfaces with hydroxy-apatite have proven to enhance fixation to bone. Addition of screws for fixation of the tibial component enhances the fixation, but has negative side effects such as osteolysis around the screws, in turn leading to a higher risk of component loosening. The magnitude and pattern of migration was studied in a randomized study of uncemented tibial implants coated with hydroxy-apatite with and without additional screw fixation in patients younger than 65 years. The uncemented implants migrated initially more than the cemented implants that constituted the control group. Both uncemented groups stabilized at 3 monthes with no further migration, while the cemented implants showed a continuous migration up to the 2 year follow-up, indicating continuous bone resorption at the implant-bone interface, a fact that might lead to an increased risk of late implant loosening. This may not be a problem in older patients, but may have consequences for long-term fixation in younger patients. There was no difference between the two uncemented groups indicating that screws do not improve fixation. Hydroxy-apatite coated knee implants might be well suited for younger patients. Mobile bearing total knee arthroplasty theoretically uncouples the forces at the implant-bone interface, thus improving fixation of the implant to bone. The magnitude and pattern of migration of a cemented mobile bearing knee arthroplasty and a fixed bearing total knee arthroplasty was compared in a randomized study. The results showed that mobile bearings did not improve fixation. Trabecular metal, a new material recently introduced for total knee arthroplasty, has several theoretical advantages. Trabecular metal tibial implants were evaluated in a randomized study in patients younger than 60 years. The implants displayed the typical migration pattern for uncemented implants with greater migration initially followed by early stabilization. The majority of the trabecular metal implants subsided into the bone with no lift-off. Lift-off has the potential of exposing the interface to joint fluid with the potential risk of bone resorption and late loosening, and is commonly seen in metal-backed implants. The finding of absence of lift-off is regarded beneficial for uncemented fixation. Trabecular metal tibial implants might be suited for younger patients. The optimal mode of fixation of the femoral component is yet to be established. Comparing cemented femoral components with uncemented femoral components in a randomized study in patients younger than 60 years revealed no differences of the magnitude or the pattern of migration. Uncemented femoral component seems equally as good as cemented components in younger patients.
|
Page generated in 0.0472 seconds