Spelling suggestions: "subject:"transiente"" "subject:"transient""
1 |
Métodos numéricos para resolução da equação de condução de calor bidimensionalSantos, Rubens Souza dos, Instituto de Engenharia Nuclear 09 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-10-04T18:28:28Z
No. of bitstreams: 1
RUBENS SOUZA DOS SANTOS M.pdf: 1776235 bytes, checksum: 4e2572d1337684f28878ba40eb2c34c4 (MD5) / Made available in DSpace on 2017-10-04T18:28:28Z (GMT). No. of bitstreams: 1
RUBENS SOUZA DOS SANTOS M.pdf: 1776235 bytes, checksum: 4e2572d1337684f28878ba40eb2c34c4 (MD5)
Previous issue date: 1981-09 / Uma classe de métodos numéricos, chamados "Algorítmos Hopscotch", foi usado para resolver a equação de condução de calor em geometria cilíndrica. Utilizando-se uma fonte de calor, com dependência temporal, procurou-se verificar o comportamento de uma vareta cilíndrica. Com os valores das temperaturas, analisou-se a estabilidade e convergência de cada método durante os transitórios. Num outro teste especificou-se a temperatura sobre a superfície como condição de contorno. Foi observado que os diversos métodos Hopscotch analisados mostraram diferentes graus de precisão, sendo alguns tão precisos quanto o método ADE, no entanto necessitando mais operações computacionais do que o método. Finalmente, comparando-se o tempo de computação, o método ODD-EVEN mostrou-se mais rápido que os outros dois métodos Hopscotch. / A class of numerical methods, called "Hopscotch Algorithms", was used to solve the heat conduction equation in cylindrical geometry, using a time dependent heat source, the temperature versus time behavior of cylindric rod was analysed. Numerical simulation was used to study the stability and the convergence os each different method. Another test had the temperature specified on the outer surface as boundary condition. The various Hopscotch methods analysed exhibit differing degrees of accuracy, few of them being so accurate as the ADE method, but requiring more computational operations than the later. Finally, compared with the so called ODD-EVEN method, two other Hopscotch methods, are more time consuming.
|
2 |
Transientes hidraúlicos em sistemas de bombeamento: influência do material do conduto e dispositivo de proteçãoTassinari, Lucas Camargo da Silva January 2017 (has links)
A análise de transientes hidráulicos em sistemas de bombeamento deve ser realizada já nos estudos de concepção, mesmo que simplificadamente, para assegurar a viabilidade técnica e econômica dos sistemas nas etapas posteriores dos estudos, com maior nível de detalhe. A magnitude dos transientes hidráulicos depende das características do sistema, dentre as quais se destaca o material dos condutos. Conhecendo-se as pressões extremas ao longo do conduto, este poderá ser dimensionado com segurança para resistir aos esforços gerados pelos transientes ou poderão ser utilizados dispositivos de proteção, reduzindo os efeitos dos transientes. A melhor escolha deverá, portanto, se basear em critérios técnicos e econômicos. Essa dissertação tem como objetivo contribuir para o estabelecimento de parâmetros e critérios que auxiliem a escolha do material dos condutos forçados em sistemas de bombeamento, ao nível de estudo de concepção, considerando-se aspectos relativos aos transientes hidráulicos e econômicos. Para tanto, foram realizadas simulações computacionais com o software Allievi. Assim, foram apresentados gráficos com as envoltórias de cargas extremas, possibilitando-se estimar o comportamento dos transientes hidráulicos em sistemas similares aos estudados. Ainda, foram realizadas análises de sensibilidade quanto ao momento de inércia do conjunto motor-bomba, comprimento e diâmetro da adutora e se discutiu como cada uma dessas características influenciou os transientes hidráulicos. Os valores de oscilação de cargas ao longo das diferentes adutoras foram relacionados com parâmetros frequentemente utilizados em estudos de sistemas de geração de energia hidrelétrica para indicar a necessidade de proteção contra transientes. Verificou-se a aplicabilidade desses parâmetros como indicadores da necessidade de proteção também em sistemas de bombeamento e, com base nesses parâmetros, propôs-se uma metodologia para estimar as envoltórias de cargas piezométricas extremas ao longo da adutora. Após, foram feitas novas simulações com os dispositivos de proteção, permitindo-se elencar soluções tecnicamente viáveis para os sistemas estudados. Ao final, para estabelecer critérios técnicos e econômicos, foram geradas curvas de custos para as adutoras de diferentes materiais e dispositivos de proteção e foram elencadas as melhores alternativas para os sistemas. Concluiu-se que o uso de dispositivos de proteção apresenta grande potencial de aplicação com vistas à redução dos custos de implantação de sistemas de bombeamento. / It is essential to analyze hydraulic transients in pumping systems already in concept design stage, even in a simplified way, to ensure its technical and economic feasibility throughout the next project stages, when there is a higher level of detailing. Hydraulic transient magnitude depends on the characteristics of the system, among which the material of the pipes stands out. By knowing the extremes pressures along the pipe, it can be safely design to withstand the stresses generated in the transient flow or protection devices may be used, reducing the effects of the transients. The best option should therefore to be based on technical and economic criteria. This dissertation aims to contribute on the establishment of parameters and criteria to support the pipe material selection in pumping systems concept design by considering aspects related to hydraulic transients and economic analysis. So, for the characterization of the unsteady flow pressure profile it has been done unsteady flow simulations by using the Allievi software. There was presented graphics with extrema head profiles to make possible to estimate the hydraulic transient behavior in pumping systems. Additionally, it has been done sensitivity analysis of the combined polar moment of inertia of motor and pump and of the pipe diameter and length. Thus, it was discussed how each of these information influenced hydraulic transient. The head oscillation values along different pipes were associated to parameters frequently used in studies of hydropower generation systems to indicate the need for protection against transients. It was verified that these parameters can be used to indicate the need of protection also in pumping systems studies and based on this it had been proposed a new simplified method to estimate extrema head profiles along the pipe. After that, new simulations were made with protection devices allowing the identification of technically feasible solutions for both studied systems. In order to establish technical and economic criteria, cost curves were generated for different pipe materials and protection devices and the best alternatives for each system were listed based on these criteria. So, it has been concluded that the use of a protection device presents a great potential to reducing pumping systems implantation costs.
|
3 |
Identificação de instabilidades hidráulicas em sistema de drenagem urbana : investigação experimental do conduto forçado Álvaro ChavesSilva, Juliana Kaiber da January 2015 (has links)
O Conduto Forçado Álvaro Chaves (CFAC), grande obra de drenagem urbana realizada na cidade de Porto Alegre (Brasil) e implantado entre 2005 e 2008, para amenizar alagamentos em ruas e avenidas de uma região altamente populosa, com cerca de 2,8km2. A concepção e dimensionamento do CFAC chamam atenção por alguns aspectos pouco usuais: um reservatório de detenção e um conduto forçado combinados na mesma estrutura e seção transversal retangular, diminuindo de montante para jusante. Além disso, também apresenta contrações verticais e horizontais sem concordâncias apropriadas, desnível geométrico abrupto e mudança de direção em ângulos vivos com diminuição da seção transversal. Esse sistema de drenagem deságua no Rio Guaíba. Em fevereiro de 2013, o CFAC ganhou notoriedade, devido ao colapso de parte de sua estrutura durante um forte evento chuvoso. A cobertura de concreto armado do CFAC foi deslocada e o solo removido, causando o afundamento do pavimento. Para investigar o CFAC, um modelo de detalhe em escala reduzida foi construído no Pavilhão Fluvial do Instituto de Pesquisas Hidráulicas da Universidade Federal do Rio Grande do Sul. A escala de redução geométrica adotada é de 1:15, resultando em um modelo de 30 m de comprimento, com alturas (16 – 42 cm) e larguras variáveis (20 – 50 cm). O modelo reproduz o reservatório de detenção, suas duas entradas e parte do conduto forçado à jusante do reservatório de detenção. O procedimento experimental baseia-se na propagação de um hidrograma no interior do conduto. As variáveis experimentais são a vazão afluente inicial, a configuração de abertura dos registros de jusante (essas duas variáveis condicionam o nível d’água inicial) e o tempo de abertura dos registros de montante. Os principais dados, gerados nos ensaios, são imagens obtidas em vídeo (câmeras normais e câmera rápida) e registros de vazão. A minuciosa análise das imagens permitiu o estabelecimento de três padrões de enchimento do conduto, apresentados a seguir. Padrão A – Enchimento do conduto sem aprisionamento de bolsões de ar e pressurização quasi-steady: observado em ensaios em que as condições de drenagem são mais favoráveis, resultando nos menores níveis iniciais de água no interior do conduto, dada uma vazão afluente. Esse padrão representa situações em que o nível do Rio Guaíba está mais baixo, permitindo maior capacidade de drenagem do sistema. Padrão B – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização quasi-steady: estabelece-se, mediante condições de drenagem um pouco mais restritivas do que no Padrão A, resultando em maiores níveis iniciais para as mesmas vazões afluentes. Situações em que o nível do Rio Guaíba encontra-se mais elevado podem ser associadas a esse padrão. Padrão C – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização unsteady: as condições de drenagem mais adversas condicionam o estabelecimento do Padrão C e resultam em altos níveis iniciais, mesmo para vazões iniciais bastante baixas. Esse padrão representa as condições mais extremas ensaiadas, seja em relação aos níveis do Rio Guaíba associados, seja em relação à severidade das consequências observadas. Além disso, inúmeros fenômenos e instabilidades hidráulicas foram observados: transição entre o escoamento à superfície livre e pressurizado, ressaltos hidráulicos móveis, aprisionamento e movimentação de bolsões de ar, ondas oscilatórias e ondas de translação. De uma maneira geral, o modelo do CFAC permite o estudo do escoamento, em regime não permanente, em um sistema de drenagem urbana que apresenta diversas singularidades, como curvas, contrações horizontais e verticais sem concordância e mudanças de direção com redução da seção transversal em ângulos vivos. / The Álvaro Chaves Penstock System (ACP) is the greater storm sewer device of Porto Alegre (Brazil), it was built between 2005 and 2008 and aims to overcome recurrent floods in main avenues located in a highly populated region of 2,8km2. The conception and design of ACP highlight some unusual aspects: the combination of an on-line detention reservoir and a penstock and the reduction of its rectangular cross-sectional area to downstream direction. Moreover, there are abrupt sharp edges contractions (horizontal and vertical), 90° bend with a reduction of rectangular cross-sectional and abrupt geometrical drop. In February 2013, the ACP became notorious because of its structural collapse during a rainstorm event. The precast concrete cover was displaced, soil was removed and the pavement descended. In order to investigate the ACP system, a partial physical model was built in the Instituto de Pesquisas Hidráulicas of the Universidade Federal do Rio Grande do Sul. The geometric scale factor is 1:15, resulting in a 30 m length, variable height (16cm - 42cm) and width (20cm - 50cm). The model reproduces the detention reservoir, its entrances and the short portion of the penstock located downstream of the detention reservoir. The experimental procedure is based is on the propagation of a hydrograph in the conduit. The experimental variables are affluent initial discharge, the overture settings of the downstream discharge valves (both variables affect initial water level in the conduct) and the opening periods of the upstream valves. The data generated during the tests are video images (general camera and high-speed camera) and discharge records. A comprehensive analysis of the images led the identification of tree basic patterns of pipe filling. Pattern A – Filling without air entrapment in quasi-steady state: observed during tests with most favorable drainage conditions, resulting in lower initial water levels in the conduct, given an initial discharge. This pattern represents situations where the Guaíba River level is lower, allowing better drainage capacity. Pattern B – Filling with air entrapment in quasi-steady state: established considering drainage conditions a little bit more restrictives than in Pattern A, resulting in higher initial levels in the conduct for the same affluent discharges. Situations of higher levels in the Guaiba River may be associated with this pattern. Pattern C – Filling with air entrapment in unsteady state: established under the most adverse drainage conditions, resulting in higher initial water level even for very low initial affluent discharges. This pattern represents the most extreme conditions tested, whether in relation to the associated levels of the Guaiba River and in relation to the severity of the observed effects. Furthermore, numerous phenomena and hydraulic instabilities were observed: transition between free surface and pressurized flow, moving hydraulic jumps, entrapment of air pockets, oscillatory waves and translational waves. In general, the ACP model allows the study of the flow in a storm sewer system under unsteady state, considering its singularities: bends, horizontal and vertical contraction without alignment and direction changes with reduction of the cross section sharp angles.
|
4 |
Transientes hidraúlicos em sistemas de bombeamento: influência do material do conduto e dispositivo de proteçãoTassinari, Lucas Camargo da Silva January 2017 (has links)
A análise de transientes hidráulicos em sistemas de bombeamento deve ser realizada já nos estudos de concepção, mesmo que simplificadamente, para assegurar a viabilidade técnica e econômica dos sistemas nas etapas posteriores dos estudos, com maior nível de detalhe. A magnitude dos transientes hidráulicos depende das características do sistema, dentre as quais se destaca o material dos condutos. Conhecendo-se as pressões extremas ao longo do conduto, este poderá ser dimensionado com segurança para resistir aos esforços gerados pelos transientes ou poderão ser utilizados dispositivos de proteção, reduzindo os efeitos dos transientes. A melhor escolha deverá, portanto, se basear em critérios técnicos e econômicos. Essa dissertação tem como objetivo contribuir para o estabelecimento de parâmetros e critérios que auxiliem a escolha do material dos condutos forçados em sistemas de bombeamento, ao nível de estudo de concepção, considerando-se aspectos relativos aos transientes hidráulicos e econômicos. Para tanto, foram realizadas simulações computacionais com o software Allievi. Assim, foram apresentados gráficos com as envoltórias de cargas extremas, possibilitando-se estimar o comportamento dos transientes hidráulicos em sistemas similares aos estudados. Ainda, foram realizadas análises de sensibilidade quanto ao momento de inércia do conjunto motor-bomba, comprimento e diâmetro da adutora e se discutiu como cada uma dessas características influenciou os transientes hidráulicos. Os valores de oscilação de cargas ao longo das diferentes adutoras foram relacionados com parâmetros frequentemente utilizados em estudos de sistemas de geração de energia hidrelétrica para indicar a necessidade de proteção contra transientes. Verificou-se a aplicabilidade desses parâmetros como indicadores da necessidade de proteção também em sistemas de bombeamento e, com base nesses parâmetros, propôs-se uma metodologia para estimar as envoltórias de cargas piezométricas extremas ao longo da adutora. Após, foram feitas novas simulações com os dispositivos de proteção, permitindo-se elencar soluções tecnicamente viáveis para os sistemas estudados. Ao final, para estabelecer critérios técnicos e econômicos, foram geradas curvas de custos para as adutoras de diferentes materiais e dispositivos de proteção e foram elencadas as melhores alternativas para os sistemas. Concluiu-se que o uso de dispositivos de proteção apresenta grande potencial de aplicação com vistas à redução dos custos de implantação de sistemas de bombeamento. / It is essential to analyze hydraulic transients in pumping systems already in concept design stage, even in a simplified way, to ensure its technical and economic feasibility throughout the next project stages, when there is a higher level of detailing. Hydraulic transient magnitude depends on the characteristics of the system, among which the material of the pipes stands out. By knowing the extremes pressures along the pipe, it can be safely design to withstand the stresses generated in the transient flow or protection devices may be used, reducing the effects of the transients. The best option should therefore to be based on technical and economic criteria. This dissertation aims to contribute on the establishment of parameters and criteria to support the pipe material selection in pumping systems concept design by considering aspects related to hydraulic transients and economic analysis. So, for the characterization of the unsteady flow pressure profile it has been done unsteady flow simulations by using the Allievi software. There was presented graphics with extrema head profiles to make possible to estimate the hydraulic transient behavior in pumping systems. Additionally, it has been done sensitivity analysis of the combined polar moment of inertia of motor and pump and of the pipe diameter and length. Thus, it was discussed how each of these information influenced hydraulic transient. The head oscillation values along different pipes were associated to parameters frequently used in studies of hydropower generation systems to indicate the need for protection against transients. It was verified that these parameters can be used to indicate the need of protection also in pumping systems studies and based on this it had been proposed a new simplified method to estimate extrema head profiles along the pipe. After that, new simulations were made with protection devices allowing the identification of technically feasible solutions for both studied systems. In order to establish technical and economic criteria, cost curves were generated for different pipe materials and protection devices and the best alternatives for each system were listed based on these criteria. So, it has been concluded that the use of a protection device presents a great potential to reducing pumping systems implantation costs.
|
5 |
Transientes hidraúlicos em sistemas de bombeamento: influência do material do conduto e dispositivo de proteçãoTassinari, Lucas Camargo da Silva January 2017 (has links)
A análise de transientes hidráulicos em sistemas de bombeamento deve ser realizada já nos estudos de concepção, mesmo que simplificadamente, para assegurar a viabilidade técnica e econômica dos sistemas nas etapas posteriores dos estudos, com maior nível de detalhe. A magnitude dos transientes hidráulicos depende das características do sistema, dentre as quais se destaca o material dos condutos. Conhecendo-se as pressões extremas ao longo do conduto, este poderá ser dimensionado com segurança para resistir aos esforços gerados pelos transientes ou poderão ser utilizados dispositivos de proteção, reduzindo os efeitos dos transientes. A melhor escolha deverá, portanto, se basear em critérios técnicos e econômicos. Essa dissertação tem como objetivo contribuir para o estabelecimento de parâmetros e critérios que auxiliem a escolha do material dos condutos forçados em sistemas de bombeamento, ao nível de estudo de concepção, considerando-se aspectos relativos aos transientes hidráulicos e econômicos. Para tanto, foram realizadas simulações computacionais com o software Allievi. Assim, foram apresentados gráficos com as envoltórias de cargas extremas, possibilitando-se estimar o comportamento dos transientes hidráulicos em sistemas similares aos estudados. Ainda, foram realizadas análises de sensibilidade quanto ao momento de inércia do conjunto motor-bomba, comprimento e diâmetro da adutora e se discutiu como cada uma dessas características influenciou os transientes hidráulicos. Os valores de oscilação de cargas ao longo das diferentes adutoras foram relacionados com parâmetros frequentemente utilizados em estudos de sistemas de geração de energia hidrelétrica para indicar a necessidade de proteção contra transientes. Verificou-se a aplicabilidade desses parâmetros como indicadores da necessidade de proteção também em sistemas de bombeamento e, com base nesses parâmetros, propôs-se uma metodologia para estimar as envoltórias de cargas piezométricas extremas ao longo da adutora. Após, foram feitas novas simulações com os dispositivos de proteção, permitindo-se elencar soluções tecnicamente viáveis para os sistemas estudados. Ao final, para estabelecer critérios técnicos e econômicos, foram geradas curvas de custos para as adutoras de diferentes materiais e dispositivos de proteção e foram elencadas as melhores alternativas para os sistemas. Concluiu-se que o uso de dispositivos de proteção apresenta grande potencial de aplicação com vistas à redução dos custos de implantação de sistemas de bombeamento. / It is essential to analyze hydraulic transients in pumping systems already in concept design stage, even in a simplified way, to ensure its technical and economic feasibility throughout the next project stages, when there is a higher level of detailing. Hydraulic transient magnitude depends on the characteristics of the system, among which the material of the pipes stands out. By knowing the extremes pressures along the pipe, it can be safely design to withstand the stresses generated in the transient flow or protection devices may be used, reducing the effects of the transients. The best option should therefore to be based on technical and economic criteria. This dissertation aims to contribute on the establishment of parameters and criteria to support the pipe material selection in pumping systems concept design by considering aspects related to hydraulic transients and economic analysis. So, for the characterization of the unsteady flow pressure profile it has been done unsteady flow simulations by using the Allievi software. There was presented graphics with extrema head profiles to make possible to estimate the hydraulic transient behavior in pumping systems. Additionally, it has been done sensitivity analysis of the combined polar moment of inertia of motor and pump and of the pipe diameter and length. Thus, it was discussed how each of these information influenced hydraulic transient. The head oscillation values along different pipes were associated to parameters frequently used in studies of hydropower generation systems to indicate the need for protection against transients. It was verified that these parameters can be used to indicate the need of protection also in pumping systems studies and based on this it had been proposed a new simplified method to estimate extrema head profiles along the pipe. After that, new simulations were made with protection devices allowing the identification of technically feasible solutions for both studied systems. In order to establish technical and economic criteria, cost curves were generated for different pipe materials and protection devices and the best alternatives for each system were listed based on these criteria. So, it has been concluded that the use of a protection device presents a great potential to reducing pumping systems implantation costs.
|
6 |
Identificação de instabilidades hidráulicas em sistema de drenagem urbana : investigação experimental do conduto forçado Álvaro ChavesSilva, Juliana Kaiber da January 2015 (has links)
O Conduto Forçado Álvaro Chaves (CFAC), grande obra de drenagem urbana realizada na cidade de Porto Alegre (Brasil) e implantado entre 2005 e 2008, para amenizar alagamentos em ruas e avenidas de uma região altamente populosa, com cerca de 2,8km2. A concepção e dimensionamento do CFAC chamam atenção por alguns aspectos pouco usuais: um reservatório de detenção e um conduto forçado combinados na mesma estrutura e seção transversal retangular, diminuindo de montante para jusante. Além disso, também apresenta contrações verticais e horizontais sem concordâncias apropriadas, desnível geométrico abrupto e mudança de direção em ângulos vivos com diminuição da seção transversal. Esse sistema de drenagem deságua no Rio Guaíba. Em fevereiro de 2013, o CFAC ganhou notoriedade, devido ao colapso de parte de sua estrutura durante um forte evento chuvoso. A cobertura de concreto armado do CFAC foi deslocada e o solo removido, causando o afundamento do pavimento. Para investigar o CFAC, um modelo de detalhe em escala reduzida foi construído no Pavilhão Fluvial do Instituto de Pesquisas Hidráulicas da Universidade Federal do Rio Grande do Sul. A escala de redução geométrica adotada é de 1:15, resultando em um modelo de 30 m de comprimento, com alturas (16 – 42 cm) e larguras variáveis (20 – 50 cm). O modelo reproduz o reservatório de detenção, suas duas entradas e parte do conduto forçado à jusante do reservatório de detenção. O procedimento experimental baseia-se na propagação de um hidrograma no interior do conduto. As variáveis experimentais são a vazão afluente inicial, a configuração de abertura dos registros de jusante (essas duas variáveis condicionam o nível d’água inicial) e o tempo de abertura dos registros de montante. Os principais dados, gerados nos ensaios, são imagens obtidas em vídeo (câmeras normais e câmera rápida) e registros de vazão. A minuciosa análise das imagens permitiu o estabelecimento de três padrões de enchimento do conduto, apresentados a seguir. Padrão A – Enchimento do conduto sem aprisionamento de bolsões de ar e pressurização quasi-steady: observado em ensaios em que as condições de drenagem são mais favoráveis, resultando nos menores níveis iniciais de água no interior do conduto, dada uma vazão afluente. Esse padrão representa situações em que o nível do Rio Guaíba está mais baixo, permitindo maior capacidade de drenagem do sistema. Padrão B – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização quasi-steady: estabelece-se, mediante condições de drenagem um pouco mais restritivas do que no Padrão A, resultando em maiores níveis iniciais para as mesmas vazões afluentes. Situações em que o nível do Rio Guaíba encontra-se mais elevado podem ser associadas a esse padrão. Padrão C – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização unsteady: as condições de drenagem mais adversas condicionam o estabelecimento do Padrão C e resultam em altos níveis iniciais, mesmo para vazões iniciais bastante baixas. Esse padrão representa as condições mais extremas ensaiadas, seja em relação aos níveis do Rio Guaíba associados, seja em relação à severidade das consequências observadas. Além disso, inúmeros fenômenos e instabilidades hidráulicas foram observados: transição entre o escoamento à superfície livre e pressurizado, ressaltos hidráulicos móveis, aprisionamento e movimentação de bolsões de ar, ondas oscilatórias e ondas de translação. De uma maneira geral, o modelo do CFAC permite o estudo do escoamento, em regime não permanente, em um sistema de drenagem urbana que apresenta diversas singularidades, como curvas, contrações horizontais e verticais sem concordância e mudanças de direção com redução da seção transversal em ângulos vivos. / The Álvaro Chaves Penstock System (ACP) is the greater storm sewer device of Porto Alegre (Brazil), it was built between 2005 and 2008 and aims to overcome recurrent floods in main avenues located in a highly populated region of 2,8km2. The conception and design of ACP highlight some unusual aspects: the combination of an on-line detention reservoir and a penstock and the reduction of its rectangular cross-sectional area to downstream direction. Moreover, there are abrupt sharp edges contractions (horizontal and vertical), 90° bend with a reduction of rectangular cross-sectional and abrupt geometrical drop. In February 2013, the ACP became notorious because of its structural collapse during a rainstorm event. The precast concrete cover was displaced, soil was removed and the pavement descended. In order to investigate the ACP system, a partial physical model was built in the Instituto de Pesquisas Hidráulicas of the Universidade Federal do Rio Grande do Sul. The geometric scale factor is 1:15, resulting in a 30 m length, variable height (16cm - 42cm) and width (20cm - 50cm). The model reproduces the detention reservoir, its entrances and the short portion of the penstock located downstream of the detention reservoir. The experimental procedure is based is on the propagation of a hydrograph in the conduit. The experimental variables are affluent initial discharge, the overture settings of the downstream discharge valves (both variables affect initial water level in the conduct) and the opening periods of the upstream valves. The data generated during the tests are video images (general camera and high-speed camera) and discharge records. A comprehensive analysis of the images led the identification of tree basic patterns of pipe filling. Pattern A – Filling without air entrapment in quasi-steady state: observed during tests with most favorable drainage conditions, resulting in lower initial water levels in the conduct, given an initial discharge. This pattern represents situations where the Guaíba River level is lower, allowing better drainage capacity. Pattern B – Filling with air entrapment in quasi-steady state: established considering drainage conditions a little bit more restrictives than in Pattern A, resulting in higher initial levels in the conduct for the same affluent discharges. Situations of higher levels in the Guaiba River may be associated with this pattern. Pattern C – Filling with air entrapment in unsteady state: established under the most adverse drainage conditions, resulting in higher initial water level even for very low initial affluent discharges. This pattern represents the most extreme conditions tested, whether in relation to the associated levels of the Guaiba River and in relation to the severity of the observed effects. Furthermore, numerous phenomena and hydraulic instabilities were observed: transition between free surface and pressurized flow, moving hydraulic jumps, entrapment of air pockets, oscillatory waves and translational waves. In general, the ACP model allows the study of the flow in a storm sewer system under unsteady state, considering its singularities: bends, horizontal and vertical contraction without alignment and direction changes with reduction of the cross section sharp angles.
|
7 |
Identificação de instabilidades hidráulicas em sistema de drenagem urbana : investigação experimental do conduto forçado Álvaro ChavesSilva, Juliana Kaiber da January 2015 (has links)
O Conduto Forçado Álvaro Chaves (CFAC), grande obra de drenagem urbana realizada na cidade de Porto Alegre (Brasil) e implantado entre 2005 e 2008, para amenizar alagamentos em ruas e avenidas de uma região altamente populosa, com cerca de 2,8km2. A concepção e dimensionamento do CFAC chamam atenção por alguns aspectos pouco usuais: um reservatório de detenção e um conduto forçado combinados na mesma estrutura e seção transversal retangular, diminuindo de montante para jusante. Além disso, também apresenta contrações verticais e horizontais sem concordâncias apropriadas, desnível geométrico abrupto e mudança de direção em ângulos vivos com diminuição da seção transversal. Esse sistema de drenagem deságua no Rio Guaíba. Em fevereiro de 2013, o CFAC ganhou notoriedade, devido ao colapso de parte de sua estrutura durante um forte evento chuvoso. A cobertura de concreto armado do CFAC foi deslocada e o solo removido, causando o afundamento do pavimento. Para investigar o CFAC, um modelo de detalhe em escala reduzida foi construído no Pavilhão Fluvial do Instituto de Pesquisas Hidráulicas da Universidade Federal do Rio Grande do Sul. A escala de redução geométrica adotada é de 1:15, resultando em um modelo de 30 m de comprimento, com alturas (16 – 42 cm) e larguras variáveis (20 – 50 cm). O modelo reproduz o reservatório de detenção, suas duas entradas e parte do conduto forçado à jusante do reservatório de detenção. O procedimento experimental baseia-se na propagação de um hidrograma no interior do conduto. As variáveis experimentais são a vazão afluente inicial, a configuração de abertura dos registros de jusante (essas duas variáveis condicionam o nível d’água inicial) e o tempo de abertura dos registros de montante. Os principais dados, gerados nos ensaios, são imagens obtidas em vídeo (câmeras normais e câmera rápida) e registros de vazão. A minuciosa análise das imagens permitiu o estabelecimento de três padrões de enchimento do conduto, apresentados a seguir. Padrão A – Enchimento do conduto sem aprisionamento de bolsões de ar e pressurização quasi-steady: observado em ensaios em que as condições de drenagem são mais favoráveis, resultando nos menores níveis iniciais de água no interior do conduto, dada uma vazão afluente. Esse padrão representa situações em que o nível do Rio Guaíba está mais baixo, permitindo maior capacidade de drenagem do sistema. Padrão B – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização quasi-steady: estabelece-se, mediante condições de drenagem um pouco mais restritivas do que no Padrão A, resultando em maiores níveis iniciais para as mesmas vazões afluentes. Situações em que o nível do Rio Guaíba encontra-se mais elevado podem ser associadas a esse padrão. Padrão C – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização unsteady: as condições de drenagem mais adversas condicionam o estabelecimento do Padrão C e resultam em altos níveis iniciais, mesmo para vazões iniciais bastante baixas. Esse padrão representa as condições mais extremas ensaiadas, seja em relação aos níveis do Rio Guaíba associados, seja em relação à severidade das consequências observadas. Além disso, inúmeros fenômenos e instabilidades hidráulicas foram observados: transição entre o escoamento à superfície livre e pressurizado, ressaltos hidráulicos móveis, aprisionamento e movimentação de bolsões de ar, ondas oscilatórias e ondas de translação. De uma maneira geral, o modelo do CFAC permite o estudo do escoamento, em regime não permanente, em um sistema de drenagem urbana que apresenta diversas singularidades, como curvas, contrações horizontais e verticais sem concordância e mudanças de direção com redução da seção transversal em ângulos vivos. / The Álvaro Chaves Penstock System (ACP) is the greater storm sewer device of Porto Alegre (Brazil), it was built between 2005 and 2008 and aims to overcome recurrent floods in main avenues located in a highly populated region of 2,8km2. The conception and design of ACP highlight some unusual aspects: the combination of an on-line detention reservoir and a penstock and the reduction of its rectangular cross-sectional area to downstream direction. Moreover, there are abrupt sharp edges contractions (horizontal and vertical), 90° bend with a reduction of rectangular cross-sectional and abrupt geometrical drop. In February 2013, the ACP became notorious because of its structural collapse during a rainstorm event. The precast concrete cover was displaced, soil was removed and the pavement descended. In order to investigate the ACP system, a partial physical model was built in the Instituto de Pesquisas Hidráulicas of the Universidade Federal do Rio Grande do Sul. The geometric scale factor is 1:15, resulting in a 30 m length, variable height (16cm - 42cm) and width (20cm - 50cm). The model reproduces the detention reservoir, its entrances and the short portion of the penstock located downstream of the detention reservoir. The experimental procedure is based is on the propagation of a hydrograph in the conduit. The experimental variables are affluent initial discharge, the overture settings of the downstream discharge valves (both variables affect initial water level in the conduct) and the opening periods of the upstream valves. The data generated during the tests are video images (general camera and high-speed camera) and discharge records. A comprehensive analysis of the images led the identification of tree basic patterns of pipe filling. Pattern A – Filling without air entrapment in quasi-steady state: observed during tests with most favorable drainage conditions, resulting in lower initial water levels in the conduct, given an initial discharge. This pattern represents situations where the Guaíba River level is lower, allowing better drainage capacity. Pattern B – Filling with air entrapment in quasi-steady state: established considering drainage conditions a little bit more restrictives than in Pattern A, resulting in higher initial levels in the conduct for the same affluent discharges. Situations of higher levels in the Guaiba River may be associated with this pattern. Pattern C – Filling with air entrapment in unsteady state: established under the most adverse drainage conditions, resulting in higher initial water level even for very low initial affluent discharges. This pattern represents the most extreme conditions tested, whether in relation to the associated levels of the Guaiba River and in relation to the severity of the observed effects. Furthermore, numerous phenomena and hydraulic instabilities were observed: transition between free surface and pressurized flow, moving hydraulic jumps, entrapment of air pockets, oscillatory waves and translational waves. In general, the ACP model allows the study of the flow in a storm sewer system under unsteady state, considering its singularities: bends, horizontal and vertical contraction without alignment and direction changes with reduction of the cross section sharp angles.
|
8 |
Simulación numérica por el método de elementos finitos del transiente hidráulico en sistemas de transporte de fluidos monofásicos a largas distanciasTapia Cárdenas, Fernando Andrés January 2018 (has links)
Ingeniero Civil Mecánico / El fenómeno de transientes hidráulicos en sistemas de transporte de fluidos por cañerías es un aspecto que debe ser analizado en detalle por las empresas de ingeniería especializadas del área. A lo largo de las historia moderna se han registrado desastres a las instalaciones, las personas y las comunidades cercanas a estas conducciones como consecuencia de un diseño inapropiado. El presente estudio desarrolla una herramienta computacional (algoritmo) que predice la variación de presión y velocidad del fluido al interior de las cañerías en un sistema de transporte de fluidos monofásicos a larga distancia durante un evento transiente.
En la actualidad existen distintos modelos que permiten predecir el coeficiente de fricción existente entre el fluido y la pared interna de la cañería, los cuales junto a las ecuaciones de conservación de masa y de movimiento, permiten calcular los valores de presión y velocidad del fluido en cualquier punto del sistema (componente espacial), y para cualquier instante de tiempo (componente temporal) luego de que el evento transiente, o golpe de ariete, se ha generado en el sistema.
Sin embargo, estos modelos se han determinado analíticamente, o bien, realizando experimentaciones en sistemas de transporte de fluido de algunos cientos metros de largo, mientras que sistemas reales, como por ejemplo de transporte de agua de mar, alcanzan varios kilómetros de distancia, por lo que realizar una validación de los modelos del coeficiente de fricción existente entre el fluido y la pared interna de la cañería cobra gran importancia, ya que permite realizar un buen diseño de estas instalaciones en etapas tempranas de un proyecto de ingeniería.
Para lo anterior, se desarrolló un algoritmo que resuelve las ecuaciones que gobiernan el fenómeno del golpe de ariete, utilizando el método de elementos finitos, y programando en el lenguaje de MATLAB. Se utilizó un escenario ficticio, el que está compuesto por un estanque con nivel constante del pelo de agua, conectado a una cañería de 5000[m] de longitud, y en el otro extremo una válvula de bola que cierra rápidamente. Este escenario corresponde a una extrapolación de los existentes en la literatura.
Se concluye con este estudio que el modelo estacionario de perdida de energía por fricción es un buen estimador. Los resultados de presión obtenidos, si bien son conservadores en comparación con los modelos cuasi-estacionario y no-estacionario, son bastante precisos para utilizarlos en el diseño de sistemas de transporte de fluidos. Además, se observó que el modelo no-estacionario estima que se pierde más energía por roce entre el fluido y la pared de la cañería, que los otros dos modelos.
|
9 |
Estudo de processos de transporte em materiais uni-dimensionais. / Study of transport processes in one-dimensional materials.Delben, Angela Antonia Sanches Tardivo 24 February 1984 (has links)
Estudos recentes em materiais unidimensionais indicaram a necessidade de alterações na equação da dinâmica de captura de portadores por armadilhas. As experiências de Haarer e Möhwald em fenantreno PMDA mostraram que o tempo de captura das armadilhas decai linearmente com o campo elétrico, a partir de um campo crítico. Neste caso podemos admitir a substituição da fórmula clássica do tempo de captura pela razão entre a distância entre as armadilhas e a velocidade do portador sob ação do campo elétrico. A velocidade do portador devido ao campo é dada pelo produto da mobiliade do portador pelo campo elétrico. Assim, a equação de balanço de cargas nas armadilhas fica alterada pelo aparecimento explícito do campo elétrico, ocasionando mudanças no próprio processo de transporte. Neste trabalho, tentou-se encontrar o comportamento de materiais unidimensionais, na região de campo de ocorrência deste fenômeno e em suas proximidades, estudando-se a característica voltagem-corrente, bem como alguns processos transientes de tratamento analítico ameno. / Recent studies in one-dimensional systems show that the trapping equations must be changed. Haarer and Möhwald experiments on Phenanthrene PMDA showed that the trapping time decays linearly with the electric field, from a critical field on. Therefore we can assume that one should substitute the classical formula of the trapping time by the ratio between the intertrap distance and the drift velocity. The drift velocity is given by the product of the carrier mobility by the field. Thus the equation of carrier trapping becomes modified by the explicit dependence on the field that leads to changes in the transport itself. In this work we tried to find the response of a material in which such behavior is observed, by studying the current voltage characteristic, and also some transient processes amenable to analytical treatment.
|
10 |
Simulador em tempo real para teste de reguladores de velocidade de turbinas hidráulicas. / Real-time simulator for hydroturbine governor tests.Santos, Eduardo Zeraib Antunes dos 21 November 2006 (has links)
Esta dissertação descreve um simulador em tempo real para aplicação em testes de reguladores de velocidade de hidrelétricas. O simulador é implementado num hardware que permite a conexão física de todos os sinais que o regulador teria na usina. As dimensões e o perfil hidráulico da usina, dados das máquinas e unidade de força hidráulica são inseridos através de tabelas de fácil entendimento pelo usuário Os transientes hidráulicos no conduto forçado são simulados usando o método das características e levam em conta a influência da turbina. A unidade hidráulica e os atuadores são modelados incluindo suas não-linearidades. Além dos testes de fábrica, este simulador pode ser utilizado para análise preliminar de transientes hidráulicos, treinamento de operadores e como plataforma de testes para novas estratégias de controle da turbina. / This work describes a real-time simulator to be used in hydroturbine speed governor tests. The simulator is implemented using a hardware configuration which allows the physical connection to the governor under test like it would be in the hydropower plant. The conduit dimensions, hydraulic scheme, machine and hydraulic power unit data are inserted into the simulator by user friendly input tables. The hydraulic transients in the penstock are simulated using the method of characteristics and take into account the turbine influence. The electrohydraulic interface, servomotor and hydraulic power unit are simulated including the nonlinearities of valves and servomotors. Besides the factory tests, this simulator can also be applied for a preliminary analysis of hydraulic transients, operator training and platform for testing new turbine control strategies.
|
Page generated in 0.1067 seconds