• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement d'un photomètre UV pour des mesures de référence de gaz d'intérêt atmosphérique : ozone et COVs

Daudé, Barthélémy 08 November 2012 (has links) (PDF)
La détermination de la section efficace d'absorption de composés atmosphériques est indispensable pour leurs mesures de concentration. Plus les valeurs de sections efficaces sont exactes, meilleure est la détermination des concentrations atmosphériques. À l'heure actuelle, la valeur de la section efficace d'absorption de l'ozone à 253,65 nm servant de standard pour la mesure de concentration de l'ozone est entachée d'une erreur de 2% et est controversée. Pour cette raison, nous avons développée un photomètre permettant d'obtenir des sections efficaces d'absorption avec une très bonne exactitude à 253,65 nm. Le but était d'atteindre une précision inférieure à 1 %. Le photomètre réalisé a été testé sur le styrène, un composé organique volatil (COV) aromatique. Les COVs comme l'ozone sont des polluants de la troposphère qui absorbent fortement dans l'UV. Outre son intérêt de molécule test, le styrène comme de nombreux COVs, a une section efficace d'absorption dans l'UV connue avec une mauvaise précision. La forte absorbance du styrène nous a obligé à travailler en basse pression (en dessous de 1 Torr). Dans ce domaine de pression, il apparaît une non-linéarité dans la mesure de pression que nous avons corrigée en mesurant la transpiration thermique du styrène. Nous avons donc obtenu la première mesure de transpiration thermique d'une molécule aromatique. Grâce à une estimation précise des erreurs et des corrections faites, nous avons montré que le photomètre réalisé atteignait bien une précision inférieure au %. Nous avons obtenu une section efficace absolue d'absorption du styrène de 1,521E−17 cm^2 avec une incertitude de 0,6 % pour un intervalle de confiance de 95 %.
2

Temperature gradient induced rarefied gas flow / Ecoulement d’un gaz raréfié induit par gradient thermique : la transpiration thermique

Rojas cardenas, Marcos javier 13 September 2012 (has links)
Ce manuscrit présente l'étude et l'analyse d'écoulements de gaz raréfiés, induits par la transpiration thermique. Le terme de transpiration thermique désigne le mouvement macroscopique d'un gaz raréfié engendré par l'effet du seul gradient de température. L'aspect principal de ce travail est centré autour de la mesure du débit stationnaire déclenché en soumettant un micro tube à un gradient de température appliqué le long de son axe. On a développé à cet effet un appareillage expérimental original ainsi qu'une méthodologie expérimentale innovatrice basée sur la dépendance du phénomène, analysé dans son ensemble, à l'égard du temps. Les résultats obtenus pour le débit stationnaire initial de transpiration thermique et pour les paramètres thermo-moléculaires caractérisant l'équilibre final de débit nul, ont été comparés aux résultats obtenus numériquement par la résolution de l'équation cinétique modèle de Shakhov et par la méthode de simulation directe de Monte-Carlo. / This thesis presents the study and analysis of rarefied gas flows induced by thermal transpiration. Thermal transpiration refers to the macroscopic movement of rarefied gas generated by a temperature gradient. The main aspect of this work is centered around the measurement of the mass flow rate engendered by subjecting a micro-tube to a temperature gradient along its axis. In this respect, an original experimental apparatus and an original time-dependent experimental methodology was developed. The experimental results for the initial stationary thermal transpiration mass flow rate and for the final zero- flow thermal molecular parameters were compared with the results obtained from the numerical solution of the Shakhov model kinetic equation and the direct simulation Monte Carlo method.
3

Numerical and experimental analysis of flows generated by temperature fields in rarefied gas : application to the design of Knudsen micropumps / Analyse numérique et expérimentale d'écoulements générés par des champs de temperature en gas raréfié : application à la conception de micropompes Knudsen

Chen, Jie 21 March 2016 (has links)
Cette thèse présente une étude numérique et expérimentale d’écoulements gazeux raréfiés confinés, induits par gradients thermiques. L’écoulement d’un gaz raréfié peut en effet être généré en appliquant uniquement un gradient tangentiel de température le long d'une paroi. Ainsi, sans gradient initial de pression, le gaz peut se déplacer de la région froide vers la région chaude. Ce phénomène, appelé transpiration thermique, est à la base du fonctionnement des pompes dites de Knudsen, capables de générer un pompage du gaz sans utiliser de pièces mécaniques mobiles. L’apport principal de ce travail est relatif à l’investigation numérique de l’écoulement de transpiration thermique dans trois nouvelles configurations de pompe Knudsen. Dans ce but, une méthode numérique de simulation d’écoulements dans le régime de glissement a été développée ; elle implémente des conditions aux limites de saut de vitesse et de température spécifiques dans un code CFD commercial. Parallèlement, un code DSMC a été mis en œuvre pour étudier des écoulements plus fortement raréfiés dans les géométries les plus complexes. Des écoulements de transpiration thermique générés dans des canaux courbés, dans des canaux convergents/divergents ou entre deux surfaces spécialement micro-texturées ont ainsi été étudiés. D’autre part, l’analyse expérimentale d’un écoulement de transpiration thermique dans un microtube de section circulaire a été réalisée sur un nouveau banc d’essais conçu pour être adaptable à diverses géométries de canaux ou de pompes Knudsen. / This thesis presents a numerical and experimental analysis of internal rarefied gas flows induced by temperature fields. In rarefied gases, a flow can be generated by solely applying a tangential temperature gradient along a wall: without any initial pressure gradient, the gas macroscopically moves from the cold toward the hot region. This phenomenon is the so-called thermal creep or thermal transpiration effect. It is the main operating principle of the Knudsen pump, which can generate gas pumping without the need of any moving parts. The main aspect of this work is centered on numerical investigations of thermal transpiration flows in three new possible configurations of Knudsen pumps. For that goal, a numerical model for slip flows has been developed in which the appropriate slip boundary conditions are implemented in a commercial CFD code and a DSMC code has been adapted for studying transition flows in complex geometries. The pumping effect of curved-channel Knudsen pumps, the thermal transpiration flows through tapered channels and between two ratchets surfaces at different uniform temperatures have been investigated. In addition, an experimental study of thermal transpiration flow through a single micro-tube has been carried out on a new experimental set-up designed to be adaptable for testing thermally driven flows through various kinds of microchannels or generated by autonomous Knudsen compressors
4

Contribution à la détermination de la courbe de pression de vapeur saturante de l'eau pure dans la plage de -80 °C à +100 °C, avec une très haute exactitude

Mokdad, Sid-Ali 28 September 2012 (has links) (PDF)
La détermination des propriétés physiques de l'eau pure, notamment la pression de vapeur saturante en fonction de la température, est un enjeu majeur en humidité et identifié comme tel par le Comité Consultatif de Thermométrie (CCT-WG6) sous-groupe Humidité du Comité Technique de Température (TC-T) afin d'améliorer les incertitudes des références nationales en humidité. A cette fin, le LNE-CETIAT et le LNE-Cnam ont développé conjointement un dispositif expérimental permettant d'accéder au couple température / pression de vapeur saturante de l'eau pure. Le principe est basé sur une mesure statique de la pression et de la température dans une cellule d'équilibre associée à un calorimètre quasi-adiabatique. La gamme de température d'équilibre couverte s'étend de 193,15 K à 373,15 K, correspondant à une pression de vapeur saturante allant de 0,06 Pa à 105 Pa.Ce travail présente la description, la réalisation et la caractérisation métrologique de ce nouveau dispositif expérimentale. Les résultats des mesures expérimentales sont comparés avec les travaux théoriques et expérimentaux les plus récents. Le budget d'incertitude finale prend en compte la contribution de la mesure de pression, de la mesure de température et des effets parasites telles que la transpiration thermique et la pression aérostatique. Grace aux différentes solutions mises en œuvre, la contribution des mesures de température dans le bilan d'incertitude globale est réduite. La part prépondérante reste essentiellement associée à la mesure de pression.
5

Contribution à la détermination de la courbe de pression de vapeur saturante de l’eau pure dans la plage de –80 °C à +100 °C, avec une très haute exactitude / Contribution to the determination of the vapour pressure curve of pure water in the temperature range between -80 ° C to +100 ° C, with high accuracy

Mokdad, Sid-Ali 28 September 2012 (has links)
La détermination des propriétés physiques de l’eau pure, notamment la pression de vapeur saturante en fonction de la température, est un enjeu majeur en humidité et identifié comme tel par le Comité Consultatif de Thermométrie (CCT-WG6) sous-groupe Humidité du Comité Technique de Température (TC-T) afin d’améliorer les incertitudes des références nationales en humidité. A cette fin, le LNE-CETIAT et le LNE-Cnam ont développé conjointement un dispositif expérimental permettant d’accéder au couple température / pression de vapeur saturante de l’eau pure. Le principe est basé sur une mesure statique de la pression et de la température dans une cellule d’équilibre associée à un calorimètre quasi-adiabatique. La gamme de température d’équilibre couverte s’étend de 193,15 K à 373,15 K, correspondant à une pression de vapeur saturante allant de 0,06 Pa à 105 Pa.Ce travail présente la description, la réalisation et la caractérisation métrologique de ce nouveau dispositif expérimentale. Les résultats des mesures expérimentales sont comparés avec les travaux théoriques et expérimentaux les plus récents. Le budget d'incertitude finale prend en compte la contribution de la mesure de pression, de la mesure de température et des effets parasites telles que la transpiration thermique et la pression aérostatique. Grace aux différentes solutions mises en œuvre, la contribution des mesures de température dans le bilan d’incertitude globale est réduite. La part prépondérante reste essentiellement associée à la mesure de pression. / The determination of the physical properties of pure water, especially the vapor-pressure curve, is one of the major issues identified by the Consultative Committee for Thermometry (CCT) of the technical committee in thermometry sub-field hygrometry to improve the accuracy of the national references in humidity.In order to achieve this objective, the LNE-CETIAT and the LNE-Cnam have jointly built a facility dedicated to the measurement of the saturation vapor pressure and temperature of pure water. The principle is based on a static measurement of the pressure and the temperature of pure water in a closed, temperature-controlled thermostat, conceived like a quasi-adiabatic calorimeter. The explored temperature range lies between 193,15 K and 373,15 K, and the pressure range between 0,06 Pa and 105 Pa.This work presents a full description of this facility and the preliminary results obtained for its characterization. The obtained results have been compared with available literature data. The final uncertainty budget took into account several components: pressure measurements, temperature measurements and environmental error sources such as thermal transpiration and hydrostatic pressure correction. Thanks to the employment of several technical solutions, the thermal contribution to the overall uncertainty budget is reduced, and the remaining major part is mainly due to pressure measurements.

Page generated in 0.1277 seconds