• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 409
  • 26
  • 15
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 1
  • Tagged with
  • 451
  • 115
  • 83
  • 75
  • 74
  • 73
  • 71
  • 68
  • 64
  • 62
  • 60
  • 57
  • 55
  • 46
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Separação de escoamento a juzante de uma obstrução assimétrica em um tubo

Fleury Junior, Plínio 09 1900 (has links)
Submitted by maria angelica Varella (angelica@sibi.ufrj.br) on 2017-12-14T13:55:38Z No. of bitstreams: 1 146554.pdf: 4680162 bytes, checksum: 6babde90328908593d96227537429f17 (MD5) / Made available in DSpace on 2017-12-14T13:55:38Z (GMT). No. of bitstreams: 1 146554.pdf: 4680162 bytes, checksum: 6babde90328908593d96227537429f17 (MD5) Previous issue date: 1967-09 / CAPES / Estuda o campo de pressões nas regiões de separação, religação e redesenvolvimento, de um escoamento a juzante de uma obstrução em um tubo. A obstrução foi realizada pelo fechamento parcial da seção transversal da entrada do tubo, tal que a área aberta na seção de entrada tinha a forma de segmento circular. As experiências foram realizadas aspirando-se ar através de um tubo de latão de 7/8 polegadas de diâmetro interno, e com 130 diâmetros de comprimento. Foram conseguidas medidas de pressões estáticas por meio de dois conjuntos de tomadas nas paredes, distribuídas ao longo do tubo e localizados a 180 ºC um conjunto do outro. Um conjunto de tomadas foi localizado no lado oposto. Foram desenvolvidos para valores de h/D = 1,00, 0,75, 0,50 e 0,25, onde h é a flexa do segmento circular e D é o diâmetro interno do tubo. O número de Reynolds cobriu o campo de 7,75 x 10 4 e 1,40 x 10 4. A distribuição das pressões, em relação ao ambiente e normalizadas pela pressão dinâmica local foi lançada como uma função da coordenada axial, para todos os casos estudados. Os gráficos mostram claramente os processos de separação, religação e redesenvolvimento. A contração do escoamento, devido à separação, causa uma queda de pressão, a qual, em termos de pressão dinâmica, vai de 1,40 a 56,00 dependendo da gradação da separação. A localização da vena contracta move-se para juzante conforme cresce a separação indo, aproximadamente, de 1/2 a 2 diâmetros. O valor porcentual da recuperação da pressão diminui e ponto de religação move-se para juzante, conforme a separação se torna maior. A assimetria no campo de pressões dei.rido à obstrução assimétrica persiste somente, até o ponto de religação, uma distância relativamente curta da entrada. Por exemplo, para a maior separação estudada aqui, as pressões resultantes dos dois conjuntos de tomadas são essencialmente idênticas após 7 diâmetros a par- tir da entrada. É notável o comportamento dessas diferenças até desaparecerem, pois mudam de sentido no espaço entre a entrada e o ponto de religação. Foram avaliados dos dados experimentais, os coeficientes de atrito, para a região completamente redesenvolvida (depois de 30 diâmetros), e estão em excelente concordância com os valores aceitos na literatura. Foram tabelados os coeficientes de perda caracterizando a separação.
232

Tubos de impedância e suas aplicações na determinação de propriedades acústicas de meios porosos

Stross, Antonio Carlos Távora 09 1900 (has links)
Submitted by maria angelica Varella (angelica@sibi.ufrj.br) on 2018-01-25T16:24:58Z No. of bitstreams: 1 141585.pdf: 1594530 bytes, checksum: 081068ca2e24ebcade33327ac1e3ee61 (MD5) / Made available in DSpace on 2018-01-25T16:25:00Z (GMT). No. of bitstreams: 1 141585.pdf: 1594530 bytes, checksum: 081068ca2e24ebcade33327ac1e3ee61 (MD5) Previous issue date: 1975-09 / A determinação da impedância acústica e coeficiente de absorção em meios porosos é realizada em tubos de impedância para ar e água. A medição em água envolve o desenvolvimento de urna técnica experimental própria. Os parâmetros porosidade, densidade, permeabilidade e espessura das amostras porosas são medidos experimentalmente, e estudado o modo como estes influenciam a impedância e absorção acústica. Os parâmetros da amostra assim determinados são introduzidos em teoria de propagação em meios porosos existente e a absorção teoricamente obtida é comparada com os dados das medições em tubo de impedância. Os valores maiores de absorção medidos em comparação com os previstos pela teoria são atribuídos as ressonâncias nas cavidades do esqueleto poroso. / Acoustic impedances and absortion coefficients in fluid-saturated porous solids are experimentally determined in air and water in impedance tubes. An experimental methodology is developed for the measurements in water. A study is made of the ways in which the experimentally measured parameters porosity, density, permeability and sample thickness, influence acoustic impedance and absortion. Those parameters are introduced into an existent theory of propagation in porous media and the resulting absortion is compared with the one obtained experimentally. The higher values of the measured acoustic absortion as compared to the ones predicted by the theory are atributed to resonancess in the cavities of the porous esqueleton.
233

Influência da dissipação viscosa na transferência de calor em tubos concêntricos no escoamento turbulento

Silva, Luiz Armando Gonzalez da 07 1900 (has links)
Submitted by maria angelica Varella (angelica@sibi.ufrj.br) on 2018-02-05T13:19:37Z No. of bitstreams: 1 146180.pdf: 940273 bytes, checksum: 98e5a844fcba28d263c4970ec45c5b5c (MD5) / Made available in DSpace on 2018-02-05T13:19:37Z (GMT). No. of bitstreams: 1 146180.pdf: 940273 bytes, checksum: 98e5a844fcba28d263c4970ec45c5b5c (MD5) Previous issue date: 1977-07 / CAPES / Determina-se o perfil de temperatura no escoamento de um fluido Newtoniano, turbulento, através de dois tubos cilíndricos concêntricos considerando a dissipação viscosa. Utilizam-se perfis de velocidade turbulento em camadas distintas Partindo das expressões de Deissler e Quarmby. Determinam-se os perfis de difusividade turbulento de quantidade de movimento em camadas distintas segundo Deissler e Quarmby e o perfil de difusividade turbulento de calor segundo Aser e Chao. Resolve-se o sistema numericamente pelo método de Crank-Nicholson. A influência da dissipação viscosa sobre o perfil de temperatura é bastante pronunciado na região do escoamento turbulento próximo às paredes dos tubos interno e externo e cresce na direção axial. / The temperature profile for a turbulent flow, of a newtonian fluid flowing between two concentric tubes has been determined. The velocity profile was based on the Deissler and Quarmby equations for turbulent flows. The momentum difusivity equation for the turbulent flow has been evaluated according o Deissler and Quarmby and the heat difusivity equations and represented according to Aser and Chao. These equations with the corresponding boundary conditions has beem solved employing the numerical method of Crank-Nicholson. The influence of the dissipation on the temperature profile is pronounced in the turbulent flow in the neighborhood of the inner and outer wall of the tube and increases in the axial direction.
234

Transferência de calor no escoamento bifásico de dois componentes, regime anular, tubo vertical

Brum, Nísio de Carvalho Lobo 07 1900 (has links)
Submitted by maria angelica Varella (angelica@sibi.ufrj.br) on 2018-02-06T13:56:42Z No. of bitstreams: 1 151834.pdf: 1799239 bytes, checksum: 86695cbee59df88bfa28f21e721a145f (MD5) / Made available in DSpace on 2018-02-06T13:56:42Z (GMT). No. of bitstreams: 1 151834.pdf: 1799239 bytes, checksum: 86695cbee59df88bfa28f21e721a145f (MD5) Previous issue date: 1979-07 / No presente trabalho é desenvolvido um modelo analítico para a determinação do coeficiente de transmissão de calor no escoamento ascendente bifásico, (ar e água) tubos verticais, regime anular. A seguir, é presentada a discussão relativa ao projeto e construção do equipamento experimental. Utilizou-se um tubo de latão de 6mm de diâmetro interno, com 1500m de comprimento, o qual foi submetido a fluxos de calor no intervalo de 0,225 a 0,704 cal/scm². Os valores da razão vazão de ar/vazão de H2O foram 8, 8,5 e 17. Finalmente, são apresentados os resultados experimentais obtidos, assim como os valores do coeficiente de transmissão de calor determinado pelo modelo. / An analytic model for determination of the heat transfer coeficient during the two phase upflow (water + air) in vertical tubes was developped. The design and construction of the equipment is then discussed. The experiments were carried out in one tube, 6mm int and 1500mm of length, which suffered heat fluxes ranging 2 from 0,225 to 0,704 cal/scm². The following ratios water mass flow rate air mass flow rate were used 8, 8.5 and 17. Finally, the experimental results are presented, as well as the values of the heat transfer coeficient determined according to the model.
235

Efeito da adição de boro na microestrutura e na resistência ao desgaste do aço inoxidável AISI 430 conformado por spray / effect of boron addition on the microstructure and wear resistance of a spray-formed AISI 430 stainless steel

Nascimento, Alexandre Romão Costa 04 August 2014 (has links)
Made available in DSpace on 2016-06-02T19:12:37Z (GMT). No. of bitstreams: 1 6127.pdf: 4996115 bytes, checksum: d851ab96fa45f0bde5c7c504dd376e2f (MD5) Previous issue date: 2014-08-04 / Universidade Federal de Sao Carlos / The contact between drill pipes during oil well exploitations induces a severe wear process that might cause well bore pipe wall rupture, fluids leakage, environmental impacts, and possibly fatal accidents. The problem is known by the oil and gas industries since the 1930 s and several solutions have been proposed by researchers and engineers in order to mitigate its deleterious effects. A method that grows popular in the industrial media is the execution of large-scale tests that consists in forcing a cylinder against the inner wall of a pipe. During this test, in order to reproduce operations conditions, the use of drilling mud as a lubricant and a wear resistant coating over the cylinder are both possible. The purpose of this work was to evaluate the effect of boron addition on the microstructure of spray-formed AISI 430 stainless steel as well as in its wear resistance in a condition comparable to the one observed during drill pipes contact. It was then necessary to develop a wear tester capable of reproducing the changes in the contact areathat occurs during the aforementioned contact. The results showed that unlike the conventional API 5L X80 steel, the spray-formed material s wear rates were constant as predicted by Archard s wear law. Despite the different wear rate behaviors, the generated wear debris showed a similar morphology in all tested materials. The tribossystem conditions induced a plastic ratchetting wear mechanism. In the light of Greenwood and Williamson s theoretical model, it was concluded that the observed changes in the wear rate on conventional steels was due to slow changes in the plasticity index which happens much more quickly in the sprayformed steels due to the presence of intermetallic borides. Moreover, considering the established test parameters, the increase in the boron content also increases the AISI 430 steel s wear resistance, since the increase in the area fraction of intermetallics decreases the rate at which metallic asperities contact each other during the test. / O contato entre os tubos utilizados para a perfuração de poços de petróleo provoca um severo processo de desgaste capaz de causar a ruptura das paredes dos tubos, vazamento de fluidos, impactos ambientais e até mesmo acidentes fatais. O problema é conhecido pela indústria de óleo e gás desde a década de 30 e diversas soluções tem sido propostas por engenheiros e pesquisadores com o intuito de mitigar seus efeitos. Um método que tem se mostrado popular no meio industrial é a realização de ensaios de grande escala que consistem no contato forçado de um cilindro contra a parede interna de um tubo, podendo-se fazer uso de revestimentos resistentes ou lamas de perfuração como lubrificantes, a fim de melhor reproduzir as condições durante a perfuração dos poços. O propósito desta dissertação foi avaliar o efeito da adição de boro na microestrutura do aço inoxidável AISI 430 conformado por spray bem como em sua resistência ao desgaste em um sistema similar ao observado nos equipamentos da coluna de perfuração. Para tanto, foi necessário desenvolver um equipamento de ensaios de escala laboratorial capaz de reproduzir as condições de progressivas mudanças da área de contato entre os tubos de perfuração e as paredes dos tubos dos poços.Observou-se que, diferentemente de aços convencionalmente usados nas tubulações de poços como o API 5L X80, as taxas de desgaste dos aços conformados por spray mostraram-se constantes, conforme previsto pela Lei de Archard. Mesmo assim, os detritos formados durante o ensaio de todos os materiais apresentaram morfologias semelhantes. Recorrendo-se ao clássico modelo de contato entre superfícies desenvolvido por Grenwood e Williamson, concluiu-se que as taxas de desgaste decrescentes observadas nos aços convencionais se devem a uma lenta mudança do índice de plasticidade que, no caso dos aços contendo boretos, se dá de maneira muito mais rápida. Assim, o aumento da porcentagem de boro melhorou, nas condições de ensaio estabelecidas, a resistência ao desgaste do aço inoxidável já que, por aumentar a fração da área de contato que corresponde aos intermetálicos do tipo M2B, diminuiu-se a frequência com que ocorre o contato plástico entre as asperezas metálicas.
236

Caracterização da interface de tubo bimetálico cladeado fundido por centrifugação / Interface characterization of centrifugal casted clad bimetallic pipe

Dessi, João Guilherme 27 March 2015 (has links)
Submitted by Livia Mello (liviacmello@yahoo.com.br) on 2016-10-04T18:22:07Z No. of bitstreams: 1 DissJGD.pdf: 11056597 bytes, checksum: 7c2ae004498264234da278ba154c685f (MD5) / Approved for entry into archive by Ronildo Prado (ronisp@ufscar.br) on 2016-10-11T20:25:22Z (GMT) No. of bitstreams: 1 DissJGD.pdf: 11056597 bytes, checksum: 7c2ae004498264234da278ba154c685f (MD5) / Approved for entry into archive by Ronildo Prado (ronisp@ufscar.br) on 2016-10-11T20:25:57Z (GMT) No. of bitstreams: 1 DissJGD.pdf: 11056597 bytes, checksum: 7c2ae004498264234da278ba154c685f (MD5) / Made available in DSpace on 2016-10-11T20:29:46Z (GMT). No. of bitstreams: 1 DissJGD.pdf: 11056597 bytes, checksum: 7c2ae004498264234da278ba154c685f (MD5) Previous issue date: 2015-03-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Bimetallic pipes represent a solution for cost reduction to pipelines in the oil and gas industry, because they combine two materials with distinct characteristics in the pipe manufacturing: a HSLA steel, constituting the external part of the pipe, providing mechanical strength and toughness, and a corrosion resistant alloy (CRA), constituting the internal part of the pipe. Bimetallic pipes can be manufactured by centrifugal casting, which gives a metallurgical bonding between the constituent materials (cladding). The objective of this work was to evaluate the interface of a bimetallic clad pipe produced by centrifugal casting, where the pipe was manufactured externally in HSLA steel (API 5L X65Q) and internally in a Ni-Cr-Mo alloy (Inconel 625) by pouring the two constituent alloys at the same side of the spinning mold. Due the temperature loss along the mold length during the CRA pouring, occurred excessive erosion in the steel close to pouring side of the pipe (hotter side) and just a little appreciable erosion close to the opposite side (colder side), where the defects accumulation prevented a suitable cladding in this region. This erosion promoted an increase of the Fe content of CRA. The as-cast microstructure of the steel in the regions where a satisfactory cladding have been observed in the interface was composed by a decarburized region with the presence of low-carbon bainite adjacent to the interface and polygonal ferrite farther from it. It was possible to combine the solubilization treatment at 1200°C/1h for the CRA and quench treatment followed by tempering necessary to ensure the mechanical properties of the steel as described by the API 5L and 5LD standards, without the occurrence of aging at the CRA. The most suitable tempering treatment have been determined at 650°C/1h, according to the mechanical tests performed at the half-length section of the bimetallic pipe and compared with a monolayer API X65Q pipe as reference. / Tubos bimetálicos representam uma solução de redução de custos em tubulações para a indústria de óleo e gás, pois combinam dois materiais de características distintas na confecção dos tubos: um aço ARBL, que compõe a parte externa do tubo, conferindo resistência mecânica e tenacidade, e uma liga resistente à corrosão (CRA), compondo a parte interna do tubo. Tubos bimetálicos podem ser fabricados por fundição centrífuga, conferindo uma união metalúrgica entre os materiais constituintes (cladeamento). O objetivo do trabalho foi avaliar a interface de um tubo bimetálico cladeado produzido por fundição por centrifugação, onde o tubo externamente é fabricado em aço ARBL (API 5L X65Q) e internamente em uma liga de Ni-Cr-Mo (Inconel 625), com o vazamento das duas ligas constituintes ocorrendo pelo mesmo lado do molde rotatório. Devido à perda de temperatura ao longo do molde durante o vazamento da liga, ocorreu erosão excessiva no aço no lado do vazamento do tubo (lado mais quente) e pouca erosão apreciável no lado oposto (mais frio), onde o acúmulo de defeitos impediu um cladeamento adequado nesta região. Esta erosão promoveu um aumento no teor de Fe da CRA. A microestrutura do aço na interface das regiões onde o cladeamento ocorreu de modo satisfatório foi composta por uma região descarbonetada, com bainita de baixo carbono adjacente à interface e ferrita poligonal presente mais distante da interface. Foi possível compatibilizar o tratamento de solubilização à 1200°C/1h da CRA e o tratamento de têmpera e seguido de revenimento, necessário ao aço para garantir as propriedades mecânicas descritas pela norma API 5L e 5LD, sem que ocorresse envelhecimento da CRA. O tratamento revenimento mais adequado foi determinado como sendo 650°C/1h, segundo os ensaios mecânicos realizados na seção do meio do tubo bimetálico e comparados a um tubo monocamada em aço API 5L X65Q de referência.
237

Tubo de calor de água, um estudo teórico-experimental

Cavalcanti, Evandro Sérgio Camelo 05 1900 (has links)
Submitted by maria angelica Varella (angelica@sibi.ufrj.br) on 2018-02-28T18:00:13Z No. of bitstreams: 1 159040.pdf: 1888369 bytes, checksum: cb2390d46d17e2fd59737cd6d4c16a8e (MD5) / Made available in DSpace on 2018-02-28T18:00:14Z (GMT). No. of bitstreams: 1 159040.pdf: 1888369 bytes, checksum: cb2390d46d17e2fd59737cd6d4c16a8e (MD5) Previous issue date: 1983-05 / Trabalho desenvolvido visando a elaboração de metodologias de projeto, fabricação e avaliação térmica de tubos de calor de água. O modelo proposto por SUN e TIEN para o desempenho térmico de tubos de calor, operando em regime permanente, foi resolvido para nova condição do fluido de resfriamento e usa do na avaliação teórica do perfil da temperatura ao longo da parede e da temperatura de saturação do vapor. Um tubo de calor capaz de transferir uma potência de 400 watts foi projetado e fabricado. O protótipo e um tubo de cobre de· 1000 mm de comprimento e 25,4 mm de diâmetro externo com 0,79 mm de espessura de parede. O meio poroso é formado por 7 camadas de tecidos metálicos de bronze fosforoso, de malhas 50 e 250, fixados na parede interna do gerando um espaço de vapor com 17 mm de diâmetro. Apresenta-se os resultados experimentais dos ensaios térmicos do protótipo e discute-se os resultados, comparando-os com as previsões teóricas. Discute-se a metodologia de projeto de tubos de calor, comparando-a aos procedimentos propostos por DUNN e CHI. / The aim of this work was to develop methodologies for the project, manufacturing and experimental thermal evaluation of heat pipes. The model suggested by SUN and TIEN for theoretical steady-state heat pipe performance was solved for a new condition of cooling fluid and used for predicting the wall temperature profile and saturated vapor temperature. A water heat pipe for a 400 watts heat removal was projected and manufacture. The prototype consists of a copper tube 1.000 mm long, with an outside diameter of 25,4 mm and a wall thickness of 0,79 mm. The wick structure is a composite phosphor bronze wrapped-screen wick with meshes 50 and 250 fitted against the inner wall of the tube to leave a vapor space diameter of 17 mm. The prototype was instrumented and monitored. The measured wall temperature profiles for several heat-input levels are compared and discussed with the theoretical predictions. The methodology for the project of heat pipes was discussed and compared with other procedures suggested by DUNN and CHI.
238

Determinação de chumbo em tubos de raios catódicos e em solo contaminado por espectrometria de absorção atômica /

Lima, Luiz Rogerio Monteiro. January 2014 (has links)
Orientador: Mirian Cristina dos Santos / Banca: Luiz Francisco Malmonge / Banca: Michael Jones da Silva / Resumo: No presente trabalho foram empregados métodos para a determinação de chumbo em vidros provenientes de tubos de raios catódicos (CRT) e solo contaminado por este tipo de resíduo. Para as análises foram utilizadas pequenas partes dos componentes do CRT (televisão e computador) de diferentes fabricantes e desmontadas manualmente. Após a moagem, as amostras vítreas foram analisadas por MEV, EDS e DRX para determinar o tamanho de partículas e a composição elementar do material investigado. Para este estudo foi utilizada uma mistura de proporção de 1:1:1:4 em peso (canhão de elétrons, pescoço, funil e tela). Para as análises por GFAAS as amostras foram digeridas em meio ácido (2,4 mL de HCl, 1,2 mL HNO 3 , 2,4 mL de HF e 2,0 mL de H 2 O), onde cerca 125mg da amostra vítrea foram adicionados em frasco de PTFE. A concentração total de chumbo nos CRTs foi determinada por GFAAS e os valores encontrados para duas misturas provenientes de diferentes amostras foram (735,52 ± 6,12) mg kg -1 e (886,61 ± 5,49) mg kg -1 . A toxicidade da amostra foi avaliada utilizando a norma ABNT NBR 10004:2004 para resíduos sólidos. A mistura foi submetida a ensaios de lixiviação e o extrato lixiviado foi analisado por espectrometria de absorção atômica em chama (FAAS) e espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Os resultados indicaram que cerca de 85% do Pb presente no resíduo foi lixiviado. Os testes lixiviação realizados para os resíduos de CRTs atingiram os valores de Classe I (resíduo perigoso) de acordo com a norma ABNT NBR 10004:2004, devido à alta concentração de chumbo presente em sua composição. Os resíduos dos CRTs foram utilizados na simulação de descarte inadequado no solo e cultivo de alface em ambiente contaminado, após a colheita foram coletadas amostras de solo e a alface. Foi realizada uma avaliação biométrica da alface para ... / Abstract: In this paper methods for the determination of lead in glass from cathode ray tube (CRT) and soil pipes contaminated by this type of waste were employed. Small parts of components CRT (television and computer) from different manufacturers were used and dismantled manually for analysis. After grinding, the vitreous samples were analyzed by SEM, EDS and XRD to determine the particle size and the elemental composition of the investigated material. For this study a mixture ratio of 1:1:1:4 by weight (electron gun, neck, funnel and screen) was used. For the analyzes by atomic absorption spectrometry in graphite furnace (GFAAS) samples were digested in acid medium ( HCl 2,4 mL, 1,2 mL HNO 3 , 2,4 mL HF and 2,0 mL of H 2 O) where about 125 mg of the glassy sample was added in PTFE bottle from the quantification was performed using the method of addition of analyte. . The total concentration of lead in CRTs was determined by GFAAS and the value for two mixtures from different samples were 735, 52 ± 6, 12 mg.kg -1 and 886.61 ± 5, 49 mg.kg -1 . The toxicity of the sample was assessed using the norm ABNT NBR 10004:2004 solid waste. The mixture was subjected to leaching tests and the leaching extract was analyzed by optical emission spectrometry with inductively coupled plasma (ICP OES) and atomic absorption spectrometry in flames (FAAS). The results indicated that about 85% of Pb present in the leach residue. The leaching tests performed for waste CRTs reached values of Class I (hazardous waste) in compliance with norm ABNT NBR 10004:2004, due to the high concentration of lead present in their composition. The danger of the glass was determined using Toxicity Characteristic leashing Procedure ( TCLP ) ( SW- 846 Method 1311 , USEPA 2003) , which determines the toxicity of waste by leaching . Waste CRTs were used in the simulation of improper disposal in soil and lettuce cultivation in contaminated ... / Mestre
239

Substituição de estabilizantes a base de chumbo pelo de cálcio-zinco no processo produtivo de tubos de PVC rígido /

Almeida, Dráusio Vicente de. January 2005 (has links)
Orientador: Hidekasu Matsumoto / Banca: Wyser Jose Yamakami / Banca: João Paulo Pereira Marcicano / Resumo: Este trabalho discute a viabilidade da substituição do estabilizante térmico a base de chumbo pelo de cálcio-zinco na produção de tubos de pvc rígido, através de análise em resultados experimentais, obtidos diretamente na indústria. De forma objetiva, foi descrito o processo de fabricação, bem como as matérias primas utilizadas e os ensaios , utilizados durante a fabricação. Foram realizados vários ensaios em doze lotes, de seis tubos de diferentes bitolas, produzidos nas plantas de Penápolis(S.P) e Simões Filho(BA), do grupo Asperbrás, de acordo com normas ditadas pela ABNT. Para cada produto (tubo), foram produzidos dois lotes distintos, um com estabilizante a base de chumbo e o outro com estabilizante a base de cálcio-zinco. A princípio, manteve-se iguais, todas as outras características de processamento, permitindo assim uma melhor análise dos resultados obtidos. Os dados obtidos, depois de analisados, permite-nos concluir,que sob o ponto de vista técnico, essa mudança é inteiramente satisfatória, pois conseguimos uma melhora significativa nas propriedades físicas do produto final, aumento de produtividade em torno de 6%, diminuição do índice de lotes rejeitados e por fim a eliminação definitiva do chumbo nas formulações das blendas, atendendo os apelos dos ecologistas e ambientalistas. Já sob o ponto de vista econômico, ficou claro, que, considerando apenas os custos diretos dos dois produtos, os estabilizantes a base de cálcio-zinco, são mais caros cerca de 25%, quando comparados aos de chumbo. Porém, quando utilizados em formulações de compostos, em quantidades adequadas ao processo, juntamente com os outros componentes, essa diferença pode praticamente se anular, viabilizando economicamente a tal mudança. / Abstract: In this work it was discussed the viability of substituting the thermo stabilizer based on lead by the calcium-zinc in the production of rigid PVC pipes, through analysis of experimental results obtained directly from the industry. Briefly, it was described the process of manufacture, as well as, the materials and assays used during the manufacturer. It were performed several assays in twelve portions of six pipes with different diameters, produced in the factories of Penápolis, São Paulo and Simões Filho, Bahia, Brazil, belonging to the Asperbras group, according to the rules from ABNT (Brazilian Association of Technical Rules). For each product (pipe) it were produced two distinct groups, one with the stabilizing based on lead and the other with the calcium-zinc stabilizing. At first, it was maintained unchanged all the other characteristics of processing, allowing a better analysis of the obtained results. The analyzed data allow the conclusion that according to the technical point of view, this change is totally satisfactory, since we got a good improvement in the physical properties of the final product, as well as, an increase in the yield around 6%, in addition to a decrease in the non-acceptable portions. At the end, it was obtained a definitive elimination of lead in the blends formulations, in accordance to the ecologists and environmentalist's appeals. Under the economical point of view it has become clear, that if consider just the direct costs of the two products, the stabilizers based on calcium-zinc are around 25% more expensive when compared to the lead based products. However, when utilize the calcium-zinc stabilizers in appropriated formulations of compounds and in quantities appropriated to the process, with the other components, this difference is not significant, turning viable this new formulation. / Mestre
240

Influência da vazão e da posição do jato de água na transferência de oxigênio por tubos venturi / Influence of flow rate and water jet position on oxygen transfer by venturi tubes

Gianjacomo, Carlos Henrique 28 April 2017 (has links)
O objetivo desse trabalho foi avaliar o potencial de reoxigenação da água por meio de tubos de Venturi. Os experimentos foram realizados em dois tanques: horizontal (TH) e vertical (TV), com volumes úteis de 100 L e 63 L, respectivamente. Os testes seguiram delineamento experimental associado a metodologia de superfície de respostas, tendo como variáveis independentes a vazão da água (Qágua) e a posição de entrada do jato (Pjato), para um único tubo de Venturi e dois tubos associados em paralelo. Como respostas, foram determinados os coeficientes globais de transferência de oxigênio do ar para a água (KLa) e as eficiências de oxigenação (EO). Os resultados indicam que a vazão da água influenciou significativamente os valores de KLa e EO, enquanto que a posição do jato só teve efeito quando os tubos de Venturi foram associados em paralelo, em ambos os tanques. De maneira geral, os melhores resultados do KLa, de até 50 h-1, foram obtidos para vazões de água mais elevadas e a jato posicionado 15 cm acima da superfície da água. Eficiências de oxigenação de até 2 kgO2 kW-1 h-1 foram observadas para baixos valores de vazão de água. Considerando-se valores experimentais de densidade de potência (DP) e volume de ar injetado por minuto na massa de água, o tanque vertical apresentou desempenho de KLa e EO ligeiramente superior ao horizontal. Os dados experimentais podem ser satisfatoriamente representados pelos modelos matemáticos obtidos. / The objective of this work was to evaluate the reoxygenation potential of water using Venturi tubes. The experiments were performed in two tanks: Horizontal (HT) and vertical (VT), with useful volumes of 100 L and 63 L, respectively. The tests followed the statistical design associated with the surface methodology of responses, having as independent variables the water flow (Qwater) and the inlet position of the jet (Pjet), for a single Venturi tube and two associated tubes in parallel. Were determined as response the global oxygen transfer coefficients from air to water (KLa) and oxygenation efficiencies (OE). The results indicate that the water flow significantly influenced the values of KLa and OE, whereas the position of the jet only had effect when the Venturi tubes were associated in parallel, in both tanks. In general, the best KLa results, up to 50 h-1, were obtained for higher water flows and a jet positioned 15 cm above the water surface. Oxygenation efficiencies of up to 2 kgO2 kW-1 h-1 were observed at low water flow rates. Considering experimental values of power density (DP) and volume of air injected per minute, the vertical tank showed a performance of KLa and EO slightly higher than vertical. The experimental data can be satisfactorily represented by the mathematical models obtained.

Page generated in 0.0381 seconds