• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 409
  • 26
  • 15
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • 1
  • Tagged with
  • 451
  • 115
  • 83
  • 75
  • 74
  • 73
  • 71
  • 68
  • 64
  • 62
  • 60
  • 57
  • 55
  • 46
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Modelo para determinação da perda de carga contínua em tubos elásticos / Model for determining the continuous head losses in elastic pipe

Rettore Neto, Osvaldo 05 August 2011 (has links)
Nos projetos hidráulicos de irrigação são contabilizadas as perdas de carga totais, que seriam as perdas contínuas ou principais e as localizadas, objetivando maximizar a uniformidade de distribuição de água, caracterizando um conjunto motobomba adequado ao sistema de irrigação e com isso, minimizando os custos anuais e de implantação do projeto. Com o uso da informática, problemas de cálculos complexos são resolvidos com muita facilidade; desta forma pode-se aplicar modelos mais complexo para calculo da perda de carga nos sistemas de irrigação, resultando em valores mais próximos da realidade, com maiores riquezas de detalhes. A perda de carga representa a dissipação de energia da água em forma de calor, ao longo da tubulação, decorrente da resistência ao escoamento oferecida pela viscosidade do fluido e pela inércia das partículas. É variável de acordo com o tamanho das rugosidades da parede do tubo, diâmetro da tubulação e com a velocidade da água. A indústria de plásticos e seus derivados, com o auxilio da engenharia, tem aprimorado a qualidade dos materiais destinados à fabricação dos tubos, principalmente de polietileno. A utilização de tubos fabricados de matérias plásticos, de menor custo, destinados à irrigação tem aumentado nos últimos anos. A flexibilidade desses tubos traz como consequência o aumento do diâmetro interno com o aumento da pressão, fato este já observado em pesquisa e que não são levados em consideração pelos equacionamentos matemáticos utilizados para determinação da perda de carga. O presente trabalho propõe um modelo onde leva em consideração o módulo de elasticidade (E) do tubo para determinar a alteração do diâmetro em tubos elásticos provocada pela pressão, afetando assim a determinação da perda de carga contínua. Conhecer detalhadamente a causa da perda de energia, com intuito de cada vez mais otimizar a energia gasta por área irrigada no cenário brasileiro, passa a ser de fundamental importância. O Modelo Elástico proposto associado à Equação Universal, apresentou índice de desempenho médio de 0,9 sendo considerado com uma estimativa muito boa da realidade. / Total head losses are accounted in the irrigation hydraulic projects, that would be the continuous losses and the local head losses, aiming to maximize the uniformity of water distribution, characterizing an adequate pump set to the irrigation system e thus, minimizing the project implantation and annual costs. With informatics support, complex calculation problems are solved with ease, therefore it is possible to apply more complex models for head loss calculation in the irrigation system, resulting in values closer to the reality, with greater details. The head loss represents the water energy dissipation as heat, along the piping, due to the resistance to the flow offered by the fluid viscosity and by the particles inertia. It is variable according to the size of the rugosities of the pipe wall, piping diameter and the water velocity. plastic industry and its derivates, with engineering support, have improved the quality of the materials for the pipe manufacturing, mainly polyethylene. The usage of plastic material pipes for irrigation, of lowest cost, has risen in the latest years. The flexibility of these pipes leads to the internal diameter increase with pressure increase, fact already observed in research and that are not taken into account by mathematics equating used to determine the head loss. This paper proposes a model where it takes into account the elastic module (E) of the pipe to determine the diameter alteration in elastic pipes due to the pressure, affecting the determination of continuous head loss. Elastic Module proposed associated to Universal Equation, showed average performance rate of 0,9% being considered a extremely good estimative of reality.
332

[en] ANALYSIS OF THE APPLICATION OF PVDF IN PIPES FOR MEASURING WATER FLOW RATE / [pt] ANÁLISE DA APLICAÇÃO DO PVDF EM TUBULAÇÕES PARA MEDIÇÃO DE VAZÃO DE ÁGUA

KHRISSY ARACELLY REIS MEDEIROS 09 January 2019 (has links)
[pt] As propriedades mecânicas, reológicas e elétricas do polímero poli (fluoreto de vinilideno) – PVDF – têm sido extensivamente estudadas, mas em particular é sua propriedade piezoelétrica que motiva a maior parte dos trabalhos, visto que a piezoeletricidade ocorre em poucos materiais e é mais intensa no PVDF em relação a outros polímeros. O fator chave que define a faixa de aplicação de polímeros piezoelétricos é a sua utilização na concepção de transdutores, sensores e atuadores. Neste sentido, a presente pesquisa analisa a aplicabilidade do polímero PVDF em tubulações para medição de vazão de água, empregando como método de medição de vazão a técnica de Flow Induced Vibration (FIV), considerando as propriedades piezoelétricas peculiares do polimorfo PVDF-B(beta). De modo geral, a FIV é um fenômeno que causa instabilidade das tubulações que transportam fluidos, tido como um problema operacional que ocorre em muitas plantas industriais. No entanto, este fenômeno passou a ser investigado como uma técnica de medição de vazão, a qual considera que a massa de um fluido pode ser indiretamente medida, medindo-se a aceleração que ela transmite para outro corpo, de modo que o desvio padrão do sinal da vibração medida aumenta com a vazão, sendo mais bem ajustado por um polinômio de segundo grau. A metodologia de trabalho consistiu em caracterizar o material espectroscopicamente, por meio de técnicas de Espectroscopia no Infravermelho com Transformada de Fourier (FTIR) e Difração de Raios-X (DRX); eletromecanicamente, em um shaker mecânico no Laboratório de Sensores a Fibras Ópticas do Departamento de Engenharia Mecânica da PUC-Rio; e finalmente em um circuito hidráulico de testes do Laboratório de Escoamento de Fluidos do Departamento de Engenharia Mecânica da PUC-Rio. Ensaios foram realizados de forma a identificar os níveis de tensões elétricas geradas pela vibração oriunda da passagem da água no tubo de PVDF. Visando à comparação com os sinais de vibração, foram realizadas medições simultâneas com acelerômetros e um filme de PVDF. Para medir a deformação no tubo adotaram-se sensores de Rede de Bragg. Os resultados dos ensaios de FIV permitiram concluir que o desvio padrão do sinal da tensão medida pelo tubo de PVDF é proporcional à vazão. No entanto, algumas variáveis precisaram ser controladas. As incertezas associadas à medição de vazão pelo tubo mostraram uma considerável redução nos níveis mais altos de vazão. Por outro lado, nos níveis mais baixos de vazão observou-se uma instabilidade muito grande, possivelmente devido ao processo de acomodação mecânica inicial do tubo. Apesar disso, uma forte relação entre o sinal gerado pelo tubo de PVDF e a vazão que induziu esta vibração permitiu que a aplicabilidade do tubo de PVDF como medidor de vazão de água fosse comprovada. / [en] The mechanical, rheological and electrical properties of polymer poly (vinylidene fluoride) - PVDF - have been extensively studied, but in particular it is its piezoelectric property that motivates most of the works, since the piezoelectricity occurs in few materials and is more intense in PVDF relative to other polymers. The key factor that defines the range of applications of piezoelectric polymers is their use in the conception of transducers, sensors and actuators. In this sense, the present research analyzes the applicability of the PVDF polymer in pipes for the measurement of water flow rate, using as flow measurement method the Flow Induced Vibration (FIV) technique, considering the peculiar piezoelectric properties of the polymorph PVDF-B(beta). In general, the FIV is a phenomenon that causes instability of the pipes that transport fluids, considered as an operational problem that occurs in many industrial plants. However, this phenomenon has been investigated as a flow rate measurement technique, which considers that the mass of a fluid can be indirectly measured by measuring the acceleration it transmits to another body, so that the standard deviation of the signal of the measured vibration increases with the flow rate, being better adjusted by a second degree polynomial. The work methodology consisted in characterizing the material spectroscopically, using Fourier Transform Infrared Spectroscopy (FTIR) and X-Ray Diffraction (XRD) techniques; electromechanically, in a mechanical shaker at the Optical Fiber Sensors Laboratory of the Mechanical Engineering Department of PUC-Rio; and finally in a test hydraulic circuit of the Laboratory of Fluid Flow of the Department of Mechanical Engineering of PUC-Rio. Tests were carried out in order to identify the levels of electrical voltages generated by the vibration caused by the passage of water in the PVDF tube. In order to compare the vibration signals, simultaneous measurements were made with accelerometers and a PVDF film. To measure the deformation in the tube, Bragg Network sensors were adopted. The results of the FIV tests allowed concluding that the standard deviation of the voltage signal measured by the PVDF tube is proportional to the flow rate. However, some variables had to be controlled. The uncertainties associated with flow rate measurement by tube showed a considerable reduction in the higher flow rates. On the other hand, in the lower levels of flow rate a very great instability was observed, possibly due to the process of initial mechanical accommodation of the tube. Nevertheless, a strong relationship between the signal generated by the PVDF tube and the flow rate that induced this vibration allowed that the applicability of the PVDF tube as a water flow meter was proved.
333

Um elemento finito de tubo tridimensional para análise geometricamente não linear de dutos / A threedimensional pipe finite element for geometric nonlenear analyses

Machado, Alexandre Cunha 03 April 2006 (has links)
In transport of fluids or even as structural elements, cylindrical shells are widely used in several segments of structure engineering. The understanding of the behavior of this type of structure along a trajectory of equilibrium resultant of a description of historical loading of different natures and, consequently, is important in the definition of the real load capacity of the ducts. In this work, a finite element for geometric and threedimensional nonlinear analyses of pipes is developed. Taking into account the nature of the analysis, proper measure of tension and deformation that are compatible with states of large deformations and displacements are studied. The Total Lagrangean formulation is adopted, but the constitutive relationships used are linear. The developed computational implementation uses a three-dimensional finite element of pipe with 2 or 3 nodes, compatible with the state of great deformations and displacements, and, also, incorporating the movements of rigid body of the structure.In order to map the nonlinear trajectories of equilibrium, using some methodologies proposed in the literature, a structure of Object-Oriented Programming is used. It allows the application of different techniques of incremental and iterative analysis integrated to the implementation of the aforementioned finite elements.Aiming to validate the formulation, the results obtained by using the program here developed are evaluated through their comparison with analytical solutions and previously published results. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / No transporte de fluidos ou mesmo como elementos estruturais as cascas cilíndricas são largamente utilizadas em diversos segmentos da engenharia civil. A compreensão do comportamento desse tipo de estrutura ao longo de uma trajetória de equilíbrio resultante de um histórico de carregamento de diferentes naturezas é importante na definição da real capacidade portante dos dutos. Neste trabalho, desenvolve-se um elemento finito para análises geometricamente não lineares tridimensionais de tubos. Levando-se em consideração a natureza da análise, são estudadas medidas adequadas de tensão e deformação, compatíveis com regimes de grandes deformações e deslocamentos. A formulação Lagrangeana Total é adotada, mas as relações constitutivas utilizadas são lineares. A implementação computacional desenvolvida emprega um elemento finito tridimensional de tubo com 2 ou 3 nós, compatível com o regime de grandes deformações e deslocamentos, incorporando, também, os movimentos de corpo rígido da estrutura. Com o objetivo de mapear as trajetórias não lineares de equilíbrio, utilizando-se algumas metodologias propostas na literatura, é usada uma estrutura de programação orientada a objetos, permitindo a aplicação de diferentes técnicas de análise incremental e iterativa integradas à implementação de elementos finitos supracitada. Visando validar a formulação, os resultados obtidos no programa desenvolvido são avaliados através da comparação com soluções analíticas e outras análises numéricas disponíveis na literatura.
334

Materiais para aplicação em arames da armadura de tração de dutos flexíveis : comportamento frente a entalhes

Wallauer, Frederico Alberto January 2015 (has links)
A armadura de tração de dutos flexíveis é a camada responsável por suportar as cargas axiais destes equipamentos em campo. Com a tendência de aumento das profundidades de exploração e produção de petróleo offshore, principalmente dos campos do pré-sal brasileiro, faz-se necessário o uso de materiais com desempenho superior. Este trabalho buscou avaliar e comparar dois aços de alta resistência mecânica para tal aplicação, um predominantemente perlítico e outro martensítico. Durante a vida em serviço destes componentes, eles sofrem tensões axiais cíclicas associadas ao processo de corrosão, que gera pites como concentradores de tensões. Considerando estes aspectos, os materiais foram avaliados segundo seu comportamento à fadiga sem e com a presença de um pequeno defeito conhecido, que atua como um entalhe e busca simular um pite de corrosão. Além disso, esses materiais foram caracterizados metalúrgica e mecanicamente e sua tenacidade à fratura foi estimada via o método do CTOD. A partir dos dados experimentais, foi quantificada a sensibilidade ao entalhe, guiada essencialmente pelo processo de iniciação de trinca, ao passo que a tenacidade à fratura não foi decisiva. O material martensítico apresentou desempenho superior em fadiga e menor sensibilidade ao entalhe e mostrou-se promissor para a aplicação como arame da armadura de tração. / The tensile armor of flexible pipes is the layer responsible for support axial loads of this equipment in field. With the trend of deep increase in offshore oil exploration and production, mainly in pre-salt fields, the use of materials with high performance becomes necessary. The aim of this dissertation is evaluate and compare two high strength steels for such application, one with perlite and other with martensitic matrix. During service life of these components, they are damaged by cyclic loading associated with corrosion process which promote corrosion pits like stress concentrators. Considering these aspects, the materials were evaluated according their fatigue behavior with and without a small defect that act as a notch and simulates a corrosion pit. In addition, they were characterized metallurgical and mechanically and their fracture toughness was estimated through CTOD test. From experimental data, notch sensitivity was quantified. This was driven by initiation process, and fracture toughness was not decisive. The martensitic material showed higher fatigue performance and lower notch sensitivity and presented itself promising for tensile armor wire application.
335

Avaliação da resistência à fadiga e corrosão-fadiga da armadura de tração de um riser flexível retirado de operação

Negreiros, Luiz Antonio Sulino de January 2016 (has links)
Risers flexíveis são comumente utilizados como parte de sistemas submarinos de produção de petróleo, sendo caracterizados por uma estrutura tubular multicamadas. Durante a instalação ou operação, estes risers podem estar sujeitos a eventos externos que podem vir a causar avarias na sua camada externa. Neste sentido, em alguns casos, faz-se necessária a reavaliação da vida em fadiga destes risers, por estarem operando numa condição diferente daquela inicialmente prevista no projeto como, por exemplo, quando o espaço anular do riser configura um ambiente corrosivo. Este trabalho avalia, por meio de teste de fadiga e corrosão-fadiga, o efeito causado pela alteração da superfície corroída na resistência à fadiga de aços de armaduras de tração de um riser retirado do campo. A corrosão se deu pelo contato da água do mar com as armaduras devido a um dano na capa externa. A intensidade da corrosão e sua relação com a vida à fadiga foram avaliadas em duas regiões do riser, sendo uma no local do dano (ruptura da capa externa) e outra 5 metros afastada do mesmo. Por meio de medidas de rugosidade e análise por imagem, verificou-se que a corrosão na região afastada foi, em geral, da ordem de 30% inferior à observada na região do dano. Após avaliação da corrosão dos arames das duas regiões, procedeu-se com os testes de fadiga e corrosão-fadiga em escala reduzida. Os resultados mostraram que, apesar da diferença na corrosão, as duas regiões apresentaram desempenho similares à fadiga ao ar. Além disso, quando comparado com dados de arames íntegros de referência, os arames corroídos tiveram uma considerável redução da resistência à fadiga nos testes ar e corrosão-fadiga, evidenciando o efeito deletério dos pites de corrosão pré-existentes, mesmo com tamanhos reduzidos. A partir das medidas de profundidades e diâmetros dos pites e com uso de modelos teóricos, foram feitas estimativas dos fatores de concentração de tensões à fadiga, Kf, sendo encontrados valores próximos ao valor obtido experimentalmente. Com base nos resultados dos testes realizados, este trabalho contribuiu com importantes dados sobre a influência da pré-corrosão no desempenho à fadiga de arames, os quais podem subsidiar o processo de reavaliação de vida à fadiga de risers flexíveis e também discussões sobre as atuais metodologias de testes de corrosão-fadiga. / Flexible risers are commonly used as part of subsea production systems in oil and gas industry and they are characterized by multilayer tubular structure. During installation or operation, these risers may be subjected to external events that might cause damages to the outer sheath. Therefore, in some cases, it is necessary to reevaluate the fatigue life of these risers because they are operating in different conditions from that originally expected in the design phase, for instance, when the flexible pipe designed for intact annulus have the outer sheath breached. By using fatigue and corrosion fatigue testing, this study evaluates the corroded surface effect on the fatigue resistance of carbon steel tensile armor removed from service. The corrosion occurred due to a damage at the riser outer sheath, which exposed the armors to the seawater. The corrosion intensity and its association to the fatigue resistance were evaluated at two regions of the riser, one at the outer sheath damage and another 5 meters away from the breach. By using roughness measurements and image analysis, it was found corrosion approximately 30% lower at the away location when compared to the damage region. After corrosion evaluation, small scale fatigue and corrosion-fatigue tests were conducted. The results showed that, despite the significant difference in corrosion, both regions presented similar fatigue life in ar. In addition, when compared to intact wires from reference data, the corroded wires had a fatigue resistance reduction for tests in both air and corrosive mean, demonstrating the detrimental effect of pre-existing corrosion pits. From the pits depths and diameters along with theoretical models, fatigue notch factors were estimated and the values were quite close to the one obtained experimentally. Based on tests results, this study contributes with important data about the influence of pre-corrosion in fatigue performance of wires, which can support the process of fatigue life reevaluation for flexible risers and discussions on current methodologies used for corrosion-fatigue tests.
336

Estudo numérico da maximização da densidade de transferência de calor do escoamento laminar sobre cilindros de seção transversal elíptica utilizando o método Design Construtal

Razera, Andre Luis January 2016 (has links)
Este trabalho tem como propósito investigar através do método Design Construtal a influência do espaçamento (S0) entre cilindros de seção transversal elíptica na maximização da densidade de transferência de calor em um escoamento externo sob efeito de convecção forçada. A razão de aspecto (r) entre os eixos vertical e horizontal dos cilindros elípticos também é um parâmetro avaliado. O estudo proposto é assumido bidimensional, incompressível, laminar e permanente. O regime de escoamento é dirigido por uma diferença de pressão ΔP, que se mantém através do domínio e é governada pelo número de Bejan (Be). Foram avaliados escoamentos com quatro diferentes números de Bejan, Be = 102, 103, 5.103, 104. O fluido que escoa através do domínio possui as propriedades termofisicas definidas pelo número de Prandtl, Pr = 0,72. O método Design Construtal, associado à busca exaustiva, foi empregado para determinar as restrições, graus de liberdade e o objetivo na avaliação geométrica do sistema A solução numérica das equações de conservação de massa, quantidade de movimento e energia foram resolvidas baseadas no método de volumes finitos, através do código comercial de dinâmica dos fluidos computacional FLUENT®. As geometrias e malha do domínio computacional foram desenvolvidas no pacote GAMBIT®. Como resultados, obteve-se que os casos ótimos apresentaram resultados consideravelmente melhores do que as demais configurações, onde se obteve ganhos de desempenho na densidade de transferência de calor de 50% a 97% em relação às configurações de menor desempenho estudadas. Além disso, foi possível verificar que o sistema adapta sua geometria ótima para cada condição de escoamento, a fim de proporcionar a melhor arquitetura de fluxo para atender ao objetivo térmico de maximizar a transferência de calor em um menor espaço físico, atendendo os princípios da Teoria Construtal. / This work investigates, through the Construtal Design method, the influence of the spacing (S0) between cylinders with elliptic cross in the maximization of the heat transfer density in an external flow with forced convection. The aspect ratio (r) between the vertical and horizontal axes of the elliptical cylinders is also evaluated. The proposed study is assumed twodimensional, incompressible, laminar and permanent. The flow regime is directed by a pressure difference ΔP, which is governed by the Bejan number (Be). The flows were evaluated for different values of the Bejan number, Be = 102, 103, 5.103, 104. The fluid flowing through the domain has its thermophysical properties defined by Prandtl number, Pr = 0.72. The Construtal Design method, associated with the exhaustive search, was used to determine the restrictions, degrees of freedom and objective in the geometric evaluation of the system. The numerical solution of the mass conservation, momentum and energy equations is solved based on the finite volume method, using the commercial fluid dynamics software FLUENT ®. The geometries and mesh of the computational domain were developed in the GAMBIT® package. The results show that the optimal cases performs considerably better than the other configurations, with an increase in the heat transfer density of 50% to 97% in comparison to the performance of lower level cases studied. In addition, it was possible to verify that the system adapts its optimal geometry to every flow condition in order to provide a better flow architecture that meets the thermal objective of maximizing a heat transfer in a smaller physical space in agreement with the principles of the Constructal Theory.
337

Espuma de alumínio como absorvedor de impacto em carrocerias de ônibus

Reis, Guilherme Leo Rossi January 2017 (has links)
O aumento da segurança das estruturas de ônibus frente a cenários de impacto e a consequente diminuição das mortes e danos causados por acidentes de trânsito são imprescindíveis em um país como o Brasil, onde o transporte rodoviário é fundamental. Nesse contexto o presente trabalho explora a possibilidade do uso de tubos de aço preenchidos com espuma de alumínio como absorvedores de impacto em estruturas de ônibus. Foi realizada a fabricação da espuma como preenchimento dos tubos de aço, que então foram ensaiados sob compressão e flexão três pontos. Um modelo em elementos finitos foi desenvolvido no software LS-Dyna, 2006, considerando as não-linearidades geométricas e do material para representação das propriedades do tubo e da espuma. Finalmente uma estrutura de ônibus rodoviário foi modelada em software de elementos finitos e sua estrutura foi modificada pela adição de espuma de alumínio como preenchimento dos tubos para melhorar o desempenho da estrutura em acidentes de tombamento e impacto semi-frontal. Comentários sobre todos os resultados, apresentando a melhora relativa da estrutura devido às modificações propostas, são finalmente apresentados, assim como a validação da metodologia numérica utilizada para representação das estruturas. / The improvement of the safety of the road bus structure against impact scenarios and reduction of the injuries and death in traffic accidents is crucial in a country like Brazil, where the road transport matrix is fundamental in the traffic of people and goods. In this context in the present work is explored the possibilities of the metallic tubes filled with aluminum foam as shock absorber in the bus structures. With this goal, an experimental campaign using tubes filled with aluminum foam was made. In these tests, uniaxial compression and three points bending tests were performed. The finite element method was implemented in LS-Dyna, 2006, and simulations were carried out, considering material and geometric non-linearities. The material properties were calibrated using the tests cited. Then, a bus structure modeled with finite element method was modified adding metallic tubes filled with aluminum foam to improve the structure performance in rollover and semi-frontal impact scenarios. Commentaries about all the results, presenting the relative improvement of the structure due to the proposed modifications, are finally presented, as well as the validation of the numerical methodology used to represent the structures.
338

Desenvolvimento de método e ferramenta para aplicação submarina de clamps de reparo de dutos ou proteção de sistemas de monitoramento

Bertoldi, Evandro January 2018 (has links)
O escoamento entre o poço marítimo e a unidade flutuante é realizado através de dutos definidos como risers. Os risers flexíveis são compostos por camadas intercaladas de diferentes materiais, como aço e polietileno, o qual cada camada possui uma função. Os mecanismos de falha mais reportados são referentes a danos na camada externa polimérica, o que leva à exposição de suas armaduras metálicas ao meio externo. Os risers rígidos são dutos fabricados normalmente em aço, formados por segmentos de dutos unidos por soldas, onde a causa de dano mais frequente é a corrosão. Tem-se como objetivo nesta dissertação, o projeto e desenvolvimento de uma ferramenta e de um método para operações submarinas em risers. A ferramenta deverá ser capaz de aplicar de forma automática, um clamp bipartido no reparo da camada externa polimérica de risers flexíveis, ou acoplar sistemas de monitoramento em risers rígidos. Já o método, deverá permitir a sua aplicação tanto no reparo quanto na proteção do sistema de monitoramento. Para isto, realizou-se uma revisão bibliográfica a fim de obter uma melhor compreensão sobre o tema estudado. Desenvolveu-se o projeto do método e da ferramenta, e, posteriormente, construiu-se o protótipo para a realização de testes de funcionamento em um duto rígido Por último, através de ensaios hidrostáticos de pressão interna e externa, realizaram-se ensaios para avaliação do comportamento do método aplicado em um duto rígido. Os ensaios comprovaram a eficácia do clamp quando aplicado em ambientes submarinos em grandes profundidades, porém apresentou vazamentos nos ensaios de pressão interna e externa. A resina epóxi utilizada não garantiu a estanqueidade, possivelmente devido a sua alta rigidez, aderência ineficaz em superfícies metálicas, ou presença de vazios ou porosidades. O ensaio de pressão interna indicou que as deformações não ultrapassaram o regime elástico tanto do duto quanto do clamp até aproximadamente 182 bar de pressão. No regime elástico, o ensaio apresentou deformações menores no clamp em relação ao duto, possivelmente porque a resina acabou absorvendo as deformações. O método demonstrou ser eficiente como recipiente para a resina, e também permitiu a montagem e fixação de um colar de sensores no seu interior. Os testes de funcionamento mostraram que a ferramenta projetada e construída mostrou-se adequada para a aplicação automática de um clamp bipartido em risers, e o método mostrou-se adequado para sua aplicação em risers, tanto no reparo quanto na proteção do sistema de monitoramento. / The drain between the maritime oil well and the floating unit is made trough pipes, which is defined as risers. The flexible risers are composed by alternate layers from different materials as steel and polyethylene, each layer has its function. The failure mechanisms more reported are referent to the damage in the external polymeric layer which leads to the exposition of the metal armature to the outside. The rigid risers are pipes usually fabricated in steel made by ducts segments connect by spot welding, where the most common damage is corrosion. This essay aims to project and create a tool and a method for submarine operations in risers. The tool must be able to apply, in an automatic way, a bipartite clamp in the repair of the flexible rises in external polymeric layer or to attach monitoring systems to the rigid risers. The method must allow its application in the repair as much as the monitoring system protection. For this, it was made a bibliographic review to obtain a better comprehension from the studied theme. A project from the method and a tool were developed, later a prototype was built to make the operation tests in a rigid pipe. At last, by internal and external pressure hydrostatic trials, were made tests to evaluate the behavior of the method applied in a rigid pipe The trials proved the efficiency of the clamps when applied in submarine environments and in depth; however there were leaks in the internal and external pressure tests. The Epóxi resin did not guarantee the leak-tightness, possible due to its hardness, ineffective adherence in metal surfaces or presence of gaps and porosities. The internal pressure trial indicated that the deformations did not exceed the elastic regime in the pipe as in the clamp until, about 182 pressure bar. In the elastic regime, the trial presented minor deformation in the clamps related to the pipe possibly, because the resin absorbed the deformation. The method has proven efficient as recipient for the resin and also allowed the assembly and fixation of a sensor collar in its interior. The operation tests showed that the designed and built tool is proper for an automatic bipartite clamp application in risers and the method has proven proper for its application in risers in repair as much as monitoring system protection.
339

Avaliação técnica de tubos emissores para irrigação localizada

Baca Garcia, Carlos Jesus [UNESP] 03 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-03Bitstream added on 2014-06-13T21:04:40Z : No. of bitstreams: 1 bacagarcia_cj_dr_botfca.pdf: 1838802 bytes, checksum: 409b0975f60ea98eae46f5f5e9811d18 (MD5) / Com o desenvolvimento da tecnologia dos plásticos, tornou-se possível à construção de tubos emissores, com padrão de qualidade, a custos relativamente baixos. O emprego da irrigação localizada, pelo sistema de gotejamento, ganhou no Brasil novo impulso a partir dos anos 90, com a instalação de diversas empresas internacionais especializadas neste mercado. As empresas mais importantes do mundo se fazem presente no Brasil e algumas multinacionais estão produzindo aqui parte de sua linha de produção, como: Netafim, Plastro, Amanco, NaanDan e como empresa brasileira fabricante, existe a Petroisa. Esse trabalho teve por objetivo caracterizar e avaliar de forma técnica e hidráulica alguns tubos emissores para gotejamento, comercializados no mercado brasileiro de acordo com as normas ISO 8796:2004 e ISO 9261:2004. O experimento foi conduzido no Laboratório de Irrigação do Departamento de Engenharia Rural, da Faculdade de Ciências Agronômicas, Universidade Estadual Paulista Julio de Mesquita Filho - Campus de Botucatu, São Paulo. A norma ISO 9261:2004 prescreve critérios para avaliar e especificar gotejadores com vazão inferior a 24 L h-1 e tem por característica principal, a flexibilidade para adaptar economicamente qualquer laboratório de irrigação, porque não especifica as características da bancada de ensaios. 2 Os ensaios visaram à determinação dos seguintes parâmetros: Coeficiente de variação de fabricação, equação característica da relação entre pressão e vazão, espessura da parede, diâmetro interno, espaçamento entre emissores, resistência à pressão hidráulica à temperatura ambiente e à temperatura de 40oC, resistência à tensão de 160 N e 180 N, e ensaio de envelhecimento precoce. As análises mostraram um coeficiente de variação de fabricação (CVf) inferior a 0,07 para todos os tubos emissores... . / With the domain of the technology of plastics, it became possible to manufacture quality emitting pipes standard, at relatively low costs. Trickle irrigation method, using emitting pipes, gained in impulse Brazil during last decade 90, with the installation of several specialized international industries. Multinationals industries such as Netafim, Plastro, Amanco, NaanDan and a Brazilian manufacturer, Petroisa are producing here part of its line of production. This work had the objective, to characterize and evaluate emitting pipes, commercialized in Brazil according to ISO 8796 and ISO 9261:2004 standards. The 4 tests were conducted in the Laboratory of Irrigation of the Faculdade de Ciências Agronômicas - Campus of Botucatu, São Paulo, Brazil. The following parameters were evaluated: manufacturing variation, pressure and discharge equation, thickness of the wall, internal diameter, emitters spacing, resistance to the hydraulic pressure at the current temperature and at raised temperature (40oC), resistance to the 160 tension and 180 N, and precocious aging. The analyses had shown manufacturing coefficients of variation below 0,07 for all the emitting pipes, (maximum value allowed by ISO 9261:2004) standard. The exponents of pressure (x), in the pressure discharge e friction were of 0.431, 0.502, 0.450, 0.575, 0.533, 0.480, 0.470 for Petro Drip, Golden Drip, Chapin, Queen Gil, Aqua Traxx, Tiran and Amanco Drip, emitters respectively, classifying them as not compensating. For ISO 9261:2004, the value of x should not exceed 0.2 to be classified as compensating. The evaluated emitters (Ram, Naan PC, Amanco Drip PC and Twin Plus) had values lesser than 0,075. The test of resistance to the tension, as ISO 9261:2004 is a useful tool to classify an emitting in reusable and not reusable pipe. Aqua Traxx emitter was classified as not reusable. It presented probably... (Complete abstract, click electronic address below).
340

Espectro do operador Laplaciano de Dirichlet em tubos deformados

Mamani, Carlos Ronal Mamani 21 March 2014 (has links)
Made available in DSpace on 2016-06-02T20:28:29Z (GMT). No. of bitstreams: 1 5894.pdf: 474601 bytes, checksum: 5d3ab33b83cca94abae2ce5efc49bf32 (MD5) Previous issue date: 2014-03-21 / Financiadora de Estudos e Projetos / Let Ω be a deformed tube in(continue...) / Seja um tubo deformado em (continua)

Page generated in 0.0275 seconds