371 |
O papel do exame ultrassonográfico na avaliação de alterações musculoesqueléticas dos segmentos toracolombar e lombar da coluna vertebral de cães / The role of ultrasonographic examination in the evaluation of musculoskeletal alterations of the thoracolumbar and lumbar segments of the canine spineErcolin, Anna Carolina Mazeto 26 February 2018 (has links)
Lesões em coluna vertebral estão intimamente relacionadas a alterações neuromusculares, de modo que pela sensibilidade dolorosa e restrição da movimentação podem levar a alterações musculares como assimetrias e atrofias. Por outro lado, a musculatura enfraquecida pode predispor a lesões vertebrais. Esse trabalho buscou investigar ultrassonograficamente a presença de alterações musculoesqueléticas em cães com suspeita clínica de alterações nos segmentos toracolombar e lombar da coluna vertebral, confirmada ou não, pelo exame radiográfico. Além da análise descritiva, o grau de atrofia muscular foi quantificado através da mensuração da espessura e área da secção transversal do músculo Multifidus dorsi no nível de cada vértebra entre T13 e L7. Análises descritivas e quantitativas foram realizadas para 30 cães hígidos e 30 sintomáticos, levando em conta a presença de lesões, escore de condição corporal e tempo de evolução do quadro (para animais com histórico de lesão). O exame ultrassonográfico possibilitou a avaliação qualitativa de superfícies ósseas dos processos articulares e espinhosos, ligamentos supraespinhoso, interespinhoso e flavo e grupos musculares que envolvem o Multifidus dorsi e Longissimus dorsi, bem como alterações de ecogenicidade e irregularidades em superfícies ósseas e fibras musculares. Para análise dos dados foi utilizado um modelo com três fatores, considerando presença de lesão, cronicidade e escore como efeitos fixos e o bloco idade-sexo-porte como efeito aleatório. A espessura do Multifidus dorsi foi menor em animais com lesão do que em cães hígidos e naqueles cães que apresentaram lesão crônica, quando comparado com animais sem histórico de lesão, não variando entre cães com escore adequado ou obesos. Houve menores valores de área da secção transversal para animais com lesão crônica e uma correlação forte entre mensurações de área dos lados direito e esquerdo para uma mesma vértebra. A ultrassonografia mostrouse um método interessante para estimativa da atrofia muscular com base na espessura do Multifidus dorsi, sobretudo no nível de T13, L1 e L3. A utilização da ultrassonografia musculoesquelética da coluna vertebral neste trabalho apresentou impacto positivo em 45% dos casos, seja por concomitantemente contribuir para o diagnóstico diferencial e influenciar na conduta em 17% dos casos ou por exclusivamente influenciar na conduta em 28% deles. O emprego deste método não afetou o diagnóstico em 55% dos casos. Portanto, é um método promissor para ser empregado na investigação musculoesquelética da coluna vertebral toracolombar e lombar, em casos específicos. / Spinal injuries are closely related to neuromuscular changes, so that pain and movement impairment can lead to muscle changes such as asymmetries and atrophies. On the other hand, the weakened muscles may predispose to vertebral injuries. This work used the ultrasound to investigate the presence of musculoskeletal alterations in the thoracolumbar and lumbar segments of the canine spine, associated or not to radiographic findings. In addition to the descriptive analysis, the muscle atrophy was quantified by measuring the thickness and crosssectional area (CSA) of the Multifidus dorsi muscle at the level of each vertebra between T13 and L7. Descriptive and quantitative analyzes were performed for 30 healthy and 30 symptomatic dogs, taking into account the presence of lesions, body condition score and chronicity (for animals with a history of injury). Ultrasound examination allowed the qualitative evaluation of bone surfaces of articular and spinal processes, supraspinatus, interspinous and flavum ligaments and paraspinal muscle groups involving Multifidus dorsi and Longissimus dorsi, as well as changes in echogenicity and irregularities in bone surfaces and muscle fibers. For data analysis a model with three factors was used, considering presence of injury, chronicity and score as fixed effects and the block age-sex-size as random effect. Multifidus dorsi thickness was lower in animals with lesions than in healthy dogs and in dogs with chronic lesions when compared to animals with no lesion history. This parameter did not vary between dogs with adequate score or obese dogs. There were lower CSA values for animals with chronic lesions and a strong correlation between CSA measurements on the right and left sides for the same vertebra. Ultrasonography was an interesting method to estimate muscle atrophy based on the Multifidus dorsi thickness, especially at the level of T13, L1 and L3. The use of the musculoskeletal ultrasonography in this study had a positive impact in 45% of the cases, either by contributing to the differential diagnosis and influencing the conduct in 17% of the cases or by exclusively influencing the conduct in 28%. The use of this method did not affect the diagnosis in 55% of the cases. Therefore, it is a promising method to be used in musculoskeletal investigation of the spine in specific cases.
|
372 |
Estudo da extração e secagem por spray dryer das cascas de Endopleura uchi (Huber) Cuatrec. Humiriaceae / Extraction and spray drying studies of Endopleura uchi (Huber) Cuatrec. Humiriaceae barksTacon, Luciana Alves 01 June 2012 (has links)
O Brasil possui uma biodiversidade em flora muito grande e uma das plantas brasileiras que tem despertado muito interesse e tem sido alvo de muitos estudos é a Endopleura uchi (Huber) Cuatrec, Humiriaceae. Esta espécie é originária da Amazônia Brasileira e é muito utilizada popularmente para o tratamento de afecções do trato genito-urinário feminino e como anti-inflamatório. Acredita-se que suas ações sejam devidas a seu principal ativo constituinte a bergenina. Assim, o objetivo do presente trabalho foi estudar diferentes técnicas de extração das cascas de Endopleura uchi, bem como avaliar o processo de secagem do extrato, utilizando a técnica por spray dryer. Para isso foram realizados estudos de extração aplicando as técnicas de maceração dinâmica e ultrassom. Foi realizada a caracterização destes extratos (análise do teor de sólidos, atividade antioxidante, teor de fenóis e de bergenina), a fim de obter aquele com as características mais desejadas para dar seguimento ao processo de secagem por spray dryer. Estas análises foram feitas com auxílio da técnica funções de desejabilidade. As partículas secas obtidas foram submetidas as análises de quantificação do marcador, avaliação da atividade antioxidante, do teor de fenóis e estudo das caracterísricas farmacotécnicas, tais como: umidade, densidade aparente, compactada, ângulo de repouso, tamanho médio de partícula. Além disso, a morfologia das partículas obtidas foi analisada com auxílio da microscopia eletrônica de varredura. Em seguida, após uma série de avaliações utilizando ferramentas estatísticas, escolheu-se um extrato para estudo de possível atividade antimicrobiana contra micro-organismos do gênero Candida. Os resultados obtidos para a caracterização dos processos extrativos mostraram que o teor de sólidos chegou até a 5,11%, a atividade antioxidante teve sua IC50 variando de 2,0 a 6,0 ?g/mL, e o teor de fenóis variou de 26 a 47%. Também foram encontrados altos teores de bergenina, na faixa de 31 a 38%. Além disso, seu rendimento chegou a 4,0% com relação à quantidade de planta. Já com relação ao processo de secagem, obteve-se altos valores de rendimento (50 a 72%), sendo que a temperatura foi o fator que mais influenciou. O ângulo de repouso variou de 26 a 39°, conferindo fluxos excelentes a aceitáveis. O tamanho de partícula teve uma grande variação de 76 a 306 ?m. As partículas mostraram-se com formato bem esférico e algumas com uma superfície mais rugosa. Os extratos apresentaram inibição no crescimento sobre diferentes gêneros de Candida avaliados. Contudo, os fatores escolhidos influenciaram bastante nas características dos extratos. As extrações realizadas comprovaram o alto teor de fenóis e a alta atividade antioxidante de Endopleura uchi. E o processo de secagem nas condições estudadas não interferiu nas atividades biológicas da planta mostrando-se promissora como antioxidante e como um possível antimicrobiano. / Brazil has one of the world\'s largest biodiversity in flora and a plant that has attracted attention is the Endopleura uchi (Huber) Cuatrec, Humiriaceae, which is native of the Brazilian Amazon. This specie is utilized in treatment of the affections of feminine tract genito urinary and such as anti-inflammatory. It is believed that their actions are deriving from the major constituent, the bergenin. Thus, the objective of this work was to study different extraction techniques and the best conditions for drying uchi extracts in a spray dryer. For this extraction studies were chosen as being extractive processes: the dynamic maceration and ultrasound. It\'s realized the extracts characterization (solid content analyze, antioxidant activity; phenols content and bergenin content), for the achievement characteristics more desirables for drying in spray dryer. The analyzes were performed with desirability functions assistant. After realized this process, the dried particles obtained were submitted the analyzes of the marker quantification, evaluation antioxidant activity, solid contents and study pharmacotechnical characteristics such as moisture, bulk and tapped densities, repose angle, the mean particle size. The morphology of the particles was analyzed with scanning electron microscopy. After various analyzes utilizing statistics tools, was determined the best extract for study of the possible antimicrobial activity adversely microorganisms of Candida species. The results obtained for the extractive process characterization showed a solid content of the 5,11%, the antioxidant activity (IC50) ranged from 2.0 to 6.0 ?g/mL, the phenols content ranged from 36 to 47%. Achieve elevated bergenin content ranged from 31 to 38%. The bergenin yields amounted to 4.0% in relationship the plant quantity. In drying process, the values for yield were high (50 to 72%) and temperature was the parameter that more influenced. The repose angle ranged from 26 to 39º, conferring excellent to acceptable flow. The mean particle size had a bigger variation, ranged from 76 to 306 ?m. The particles showed spherical format and some of them with irregular surface. The extracts presented inhibition in growth of the different species Candida evaluated. However, the chosen factors significantly affect the characteristics of the extract. The extractions indicated the high phenols content and high antioxidant activity of the Endopleura uchi. And the drying process, in studies conditions, did not interfere in biological activities of the plant. Thus, Endopleura uchi showed how good antioxidant and a possible antimicrobial.
|
373 |
Estudo comparativo de duas técnicas de enxerto autógeno utilizando piezocirurgia para levantamento de seio maxilar / Comparative study of two autogenous graft techniques using piezosurgery for sinus liftingCamargo Filho, Geraldo Prestes de 28 May 2010 (has links)
A técnica de levantamento de seio maxilar apresenta como uma possível complicação a perfuração da membrana sinusal. A utilização de dispositivos ultrassônicos apresenta-se como uma interessante ferramenta, particularmente segura e eficiente para realização das ostectomias de parede sinusal e divulsão de membrana sinusal. O presente trabalho teve por objetivo comparar duas técnicas que utilizam a cirurgia ultrassônica para realização de enxerto autógeno para levantamento de seio maxilar. Dez coelhos foram utilizados no estudo, sendo que um deles não foi submetido a procedimento cirúrgico. Os nove coelhos operados tiveram os seios maxilares preenchidos com enxertos autógenos coletados de díploe externa de calota craniana, nas formas particulado do lado direito e raspado do lado esquerdo, ambos com aparelho ultrassônico. Os dados de densidade óssea nos seios maxilares esquerdo e direito, obtidos por meio de tomografia computadorizada nos sentidos transversal e longitudinal, registrados 90 dias após a realização dos enxertos foram comparados estatisticamente. Cortes histológicos das áreas enxertadas foram realizados com finalidade descritiva. Não houve diferenças estatisticamente significantes entre as técnicas de enxerto que utilizaram osso raspado e particulado coletado por meio de dispositivo ultrassônico da calota craniana de coelhos. O aspecto histológico observado após 90 dias foi semelhante nos dois grupos, mostrando tecido ósseo maduro em meio a tecido conjuntivo frouxo. Os procedimentos transoperatórios nos levaram a concluir que o ultrassom piezoelétrico mostrou-se um instrumento seguro na abordagem cirúrgica do seio maxilar de coelhos, permitindo a manutenção da integridade da membrana sinusal durante as manobras cirúrgicas. / Maxillary sinus lifting is a technique which presents as a possible complication the sinus membrane perforation. The use of ultrasonic devices is presented as an interesting tool, particularly safe and efficient to perform ostectomies of sinus wall and dissection of sinus membrane. This study aimed to compare two techniques that used ultrasound surgery to perform autogenous graft for maxillary sinus lifting. Ten rabbits were used in the study, one of which did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were compared statistically. Histological sections of the grafted areas were performed with descriptive purposes. There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device of the skull of rabbits. Histological aspects after 90 days were similar in both groups, showing mature bone through a fibrous connective tissue. Operatory assessment procedures leads us to conclude that the piezoelectric ultrasound showed as a safe tool in the surgical approach of the maxillary sinus of rabbits, allowing the maintenance of sinus membrane integrity during surgical procedures.
|
374 |
Phantom antropomórfico para treinamento de biópsia de tireoide guiada por ultrassom / Anthropomorphic phantom for training of ultrasound-guided biopsyGrillo, Felipe Wilker 30 September 2015 (has links)
O câncer de tireoide é um dos mais comuns da região da cabeça e pescoço. Atualmente, o método mais eficaz no diagnóstico de lesões da tireoide é a técnica de biópsia conhecida por punção aspirativa por agulha fina (PAAF) guiada por ultrassom. As imagens de ultrassom são utilizadas como guia para inserção de uma agulha fina até a região da lesão, onde são retirados fragmentos de tecido para análise microscópica. O sucesso dos procedimentos de biópsias está diretamente ligado a experiência do médico desde guiar a agulha à lesão até a preparação das lâminas para análise microscópica. O treinamento médico proporciona, durante a realização dos procedimentos, maior confiança ao médico e maior conforto ao paciente. No entanto o número de pacientes disponíveis, bem como o estágio de graduação do profissional, limitam o número de treinamentos realizados. Com base nessas limitações, esse estudo teve por objetivo o desenvolvimento de um phantom de tireoide permitirá que os treinamentos sejam realizados em qualquer horário e local, minimizando a responsabilidade de alunos e professores. Phantoms para ultrassom, geralmente, são corpos de prova construídos para mimetizar propriedades mecânicas e acústicas dos tecidos biológicos que podem ser utilizados no treinamento de habilidades médicas. Para o desenvolvimento deste modelo, utilizou-se um material a base de hidrocarbonetos de cadeia longa com diferentes concentrações de agentes contraste (pó de vidro, cera de carnaúba, parafina granulada, borracha de silicone). Caracterizou-se amostras de diferentes composições com relação ao módulo elástico, velocidade e atenuação da onda ultrassônica, de modo à atingir valores próximos aos encontrados na literatura para as regiões a serem mimetizadas. Obteve-se valores entre 1385 e 1480 m/s, para velocidade; valores entre 0,4 e 4 dB/cm para atenuação; e uma faixa entre 40 e 750 kPa para o módulo elástico. Ao final da caracterização dos materiais, obteve-se um phantom morfológico de pescoço, contendo a mimetização da tireoide para procedimentos de biópsia de tireoide guiada por ultrassom. / The thyroid cancer is one of the most common of head and neck region. Currently, the most effective method in the diagnosis of thyroid lesions is biopsy technique, known by fine-needle aspiration (FNA) guided by ultrasound. Ultrasound images guides the fine needle insertion into the lesion for sampling and then examined under a microscope. The medical training provides greater confidence to physician and comfort to patient. However, the number of available patients as well as the doctor degree stage limit the number of trainings conducted. Therefore, this study aimed to develop a thyroid phantom to training everywhere at any time, minimizing the students and teachers responsibilities. Ultrasound Phantoms mimics mechanical and acoustic properties of biological tissue and can be used for medical training. To develop the phantom we used a hydrocarbon-based material with different concentrations of contrast agents (glass powder, Carnauba wax, paraffin wax and silicone rubber). We calculated the elastic modulus, velocity and ultrasonic wave attenuation of different mixtures to reach values, as close the literature as possible. Was obtained values from 1385 to 1480 m / s for ultrasound velocity, values from 0.4 to 4 dB/cm for attenuation and a range from 40 to 750 kPa for elastic modulus. This study present an anthropomorphic neck phantom containing the necessary structures for training ultrasound guided biopsy by fine-needle aspiration.
|
375 |
Aplicação do transdutor magnetoacústico em estudos gástricos: in vitro e in vivo / Magnetoacústico transducer application in gastric studies: in vitro and in vivo.Bruno, Alexandre Colello 23 January 2015 (has links)
A proposta deste trabalho foi desenvolver e avaliar as aplicações do transdutor magnetoacústico, em estudos in vitro e in vivo como ferramenta para o diagnóstico clínico, inicialmente para a análise de motilidade gastrintestinal. Na primeira etapa, a intensidade do campo magnético foi mapeada e ajustada, o melhor processamento para os dados foi definido e a viabilidade do uso de nanopartículas como marcadores foi contatada. Nos estudos in vivo, realizados em ratos, avaliou-se o potencial do transdutor híbrido para análise do esvaziamento gástrico, de alimentos marcado com partículas magnéticas, comparando os dados susceptométricos (padrão ouro) com os acústicos. O esvaziamento foi relacionado com a variação de área do estômago no tempo, que foi demarcada nas imagens de ultrassom usando a vibração das partículas como contraste. Outras variações e aplicações da ultrassonografia magnetomotriz foram investigadas, usando a excitação magnética pulsada (antes harmônica), aumentando a taxa de aquisição das imagens e gerando imagens elastográficas em fantomas. A produção e detecção de Shaer Waves (elastografia absoluta) também foi avaliada em outros fantomas com uma esfera de ferrita, sem e com uma inclusão mais rígida. A ultrassonografia magnetomotriz pulsada e o processamento vinculado a ela foram capazes de gerar as shear waves, através de puxões magnéticos na esfera de ferrita, e estimar a velocidade de propagação dessas. Com esta velocidade, estimaram-se os coeficientes elástico e viscoso dos meios de propagação. Portanto, o transdutor magnetoacústico, avaliado de diversas formas nesse trabalho, apresentou-se como uma potencial ferramenta para diagnóstico da motilidade gástrica in vivo, usando tanto a ultrassonografia magnetomotriz harmônica como a pulsada. As técnicas de processamento podem ser convencionais (modos Doppler, Power Doppler e elastográficos) ou dedicadas, as quais podem detectar deslocamentos, deformações ou propagação de ondas sísmicas; suas aplicações não se limitam ao estômago e nem os diagnósticos in vivo. / The aim of this study was to develop and to evaluate applications magneto-acoustic transducer in phantoms and in vivo studies, as a tool for clinical diagnosis, initially for analysis of gastrointestinal motility. First step, the magnetic field intensity was adjusted and mapped; the best data and image processing was defined, and nanoparticles markers were studied to future applications. In experiments with rats (in vivo), we evaluated the hybrid transducer potential by gastric emptying analysis using foods labeled magnetic particles, comparing the susceptometric data (gold standard) with the acoustic. Others magneto motive ultrasonography variations and applications were investigated. The variations were the pulsed magnetic excitation and the high frame rate. The rats empty gastric were evaluated with solid and liquid food by pulsed magneto-motive ultrasound; the solid food took longer to leave the stomach, as was expected. Other applications based on the use of elastography techniques combined with pulsed magneto-motive ultrasound in phantoms were evaluated - the first potential application was the lesions detection in the colon wall (by elastography relative). In this case, harder inclusions were located by elastography based on deformations caused by the magnetic pulse and by the magnetic fluid inserted in the supposed colon. The second potential application was Shear Waves production and detection (Transient elastography) using a ferrite sphere inside the phantoms with a harder inclusion. The pulsed Magneto Motive Ultrasound was able to generate shear waves by magnetic \"pushes\" in the ferrite sphere and it estimated the speed propagation of these. Therefore, the Magneto-Acoustic transducer showed that it is a potential tool for gastric motility diagnosis in vivo, using the harmonic or pulsed Magneto-Motive Ultrasound. Their processing techniques can be conventional (Doppler, Power Doppler and elastography modes), or dedicated to detect displacements, strains and seismic waves propagation, and its applications are not limited to stomach and in vivo diagnostics.
|
376 |
Aplicação do ultrassom para avaliação de cavidades intra-ósseas, em mandíbulas de porco / Application of ultrasound for evaluation of intraosseous cavities in pig jawFerreira, Thásia Luiz Dias 23 March 2010 (has links)
O ultrassom é rotineiramente utilizado para avaliação de tecidos moles, contudo é um método que possui características importantes para avaliação não somente destes tecidos, mas dos ósseos também, além de possuir recursos diferenciais que auxiliariam muito no planejamento do tratamento e do prognóstico; embasados nessa premissa analisamos a possibilidade de avaliação de alterações intra-ósseas, por meio do ultrassom. A amostra foi constituída por cinco mandíbulas de porco, maceradas, e avaliadas nas regiões dos terceiros molares (tanto do lado direito quanto do esquerdo, totalizando 10 avaliações), por possuírem nessa região uma cripta óssea expressiva, o que simularia uma lesão intra-óssea. Para as avaliações ultrassonográficas dois grupos de três observadores foram formados, sendo um de CirurgiõesDentistas (Radiologistas) e outro de Médicos (Ultrassonografistas), os quais avaliaram, individualmente, a facilidade de visualização da imagem obtida por meio da ultrassonografia, bem como também o grau de translucidez do osso. Sendo que 46,6% das avaliações feitas pelos Cirurgiões-Dentistas foram ponderadas como de fácil visualização, 13,3% foram considerados de média dificuldade para avaliação, contra 23,3% que foram classificadas como de difícil localização, contudo 16,6% não foram possíveis de serem observadas. Os médicos classificaram como de fácil visualização 43,3% das ultrassonografias avaliadas, 23,3% como de média dificuldade, 20% de difícil observação e não conseguiram visualizar em 13,3% da amostra. Após avaliar os resultados encontrados e embasados na revisão da literatura foi possível concluir que: é possível se avaliar cavidades intraósseas por meio da ultrassonografia, contudo, para isso é necessário que a cortical óssea, por onde o feixe de ondas ultrassônicas vai penetrar, esteja adelgaçada; o US é um método imaginológico de fácil execução e interpretação, uma vez que os Cirurgiões- Dentistas que não tinham acesso, nem familiaridade, com este recurso imaginológico, conseguiram não só utilizá-lo, mas também compreender suas imagens, contudo em um grau discretamente menor em relação ao grupo formado por Médicos Ultrassonografistas, o que pode ser justificado por uma maior experiência por parte desses profissionais; mais estudos devem ser conduzido a fim de se explorar mais os benefícios e as vantagens que o US pode oferecer na área Odontológica. / Ultrasound (US) is routinely used for evaluation of soft tissues; however it is a method that has important features to evaluate not only these tissues, but also hard tissues that could help in the treatment planning and prognosis. This study analyzed the possibility of evaluation of intra-osseous changes, by means of US; grounded in this premise. The sample consisted of five macerated pig jaws, and the third molars areas (both the right and the left, totaling 10 ratings) were evaluated as these regions have a significant bone crypt, which simulate an intra-osseous lesion. For ultrasound images assessments two groups of three observers were trained, one of dentists (Radiology specialists) and other of physicians (US specialists), which evaluated individually, the visualization of the image obtained by US, and also the translucency degree of the bone. Dentists have been considered 46.6% of the assessments of easy viewing; 13.3% were considered of medium difficulty; 23.3% were classified as very difficult, although 16.6% were not found. Physicians considered 43.3% of images of easy viewing; 23.3% were considered of medium difficulty; 20% were classified as very difficult, although 13,3% were not found. Based on this results and the literature findings, it is possible to conclude that US is a useful tool for assessment of intraosseus cavities, but cortical bone should be thin so the sound waves can penetrate. US is an imaging method easy to perform and interpret, as the dentists, who had no access or familiarity with US, could interpret its images, at a slightly lower level than the US specialists, which can be explained by greater experience by these professionals. More studies should be conducted in order to explore the potential benefits and advantages of US utilization in Dentistry.
|
377 |
Avaliação ultrassonográfica da musculatura do sistema estomatognático em indivíduos com disfunção temporomandibular muscular / Ultrasound evaluation the muscle stomatognathic system in individuals with temporomandibular disorder muscleLecaros, Antuanett Mercedes Cornejo 16 August 2012 (has links)
A disfunção temporomandibular (DTM) engloba as alterações relacionadas com as articulações temporomandibulares (ATMs), a musculatura mastigatória e demais estruturas do sistema estomatognático apresentando-se na forma de dores nos músculos da mastigação, ATMs, músculos cervicais, reduções e desvios nos movimentos da mandíbula, sons articulares e padrões de oclusão inadequados. É de relevante importância estudar a musculatura mastigatória por causa da grande influência que a mesma tem no sistema estomatognático. O objetivo deste estudo foi analisar a espessura do músculo masseter e temporal, bilateralmente, por meio da ultrassonografia em indivíduos portadores de DTM muscular, com a finalidade de definir o padrão de espessura muscular nesta disfunção. Os resultados deste estudo permitiram a avaliação do sistema estomatognático do ponto de vista funcional em indivíduos portadores de DTM muscular e poderão nortear o cirurgião dentista na elaboração de diagnósticos, prognósticos e planos de tratamento, com ganho de qualidade de vida para seus pacientes. Portanto conclui-se que na condição de repouso como no apertamento em máxima intercuspidação habitual houve uma diminuição da espessura do músculo masseter esquerdo, temporal direito e esquerdo para o grupo com DTM muscular. E com relação ao gênero houve uma diminuição da espessura muscular, tanto para o músculo masseter quanto para o músculo temporal, nas mulheres. / The temporomandibular disorders (TMD) includes changes related to the temporomandibular joints (TMJ), masticatory muscles and other structures of the stomatognathic system presents itself as pain in the masticatory muscles, joints, cervical muscles, cuts and deviations in the movements of jaw joint sounds and patterns of inadequate occlusion. It is of major importance to study the masticatory muscles because of the great influence which it has in the stomatognathic system. The objective of this study was to analyze the thickness of the masseter and temporal bilaterally by ultrasonography in patients with TMD muscle, in order to set the standard for this thick muscle dysfunction. The results of this study will allow assessment of the stomatognathic system\'s functional point of view in individuals with TMD muscle and can guide the dentist in making diagnoses, prognoses and treatment plans, with gains in quality of life for their patients. Therefore it is concluded that at rest as in clenching in maximum intercuspation was a thinning of the left masseter, temporalis left and right for the group with muscular TMD. And with respect to gender there was a decrease in muscle thickness for both the masseter and temporalis muscle for in women.
|
378 |
Avaliação do uso da ultrassonografia modo B para exploração através de tecido ósseo de costelas bovinas / Evaluation of the use of ultrasound B-mode exploration through bone beef ribsAbreu, Marcos Petto Nunes de 30 July 2012 (has links)
O uso da ultrassonografia, para diagnóstico, como forma de exame complementar na área da Saúde é cotidiano e consagrado, principalmente no estudo e avaliação das doenças em tecidos moles. Com a consolidação e o desenvolvimento deste método, novos usos vem sendo descritos. Existem relatos científicos da possibilidade do uso do ultrassom para avaliação de lesões no interior do tecido ósseo. Frente a esta alternativa, o presente estudo avaliou o uso da ultrassonografia para exploração através de tecido ósseo, de diferentes espessuras, com a utilização de um modelo laboratorial em costelas bovinas, definindo a espessura óssea cortical que permite a passagem do ultrassom. Primeiramente realizamos um ensaio experimental para definir a melhor metodologia para o estudo. O modelo laboratorial usado era constituído por uma costela bovina, macerada, desgastada em diferentes espessuras. A amostra do estudo foi constituída em 180 leituras de ultrassom provenientes de 20 costelas bovinas maceradas; onde cada uma delas foi examinada em 9 áreas que se diferenciavam na espessura do remanescente ósseo; assim definidas 4,0mm, 3,0mm, 2,5mm, 2,0mm, 1,5mm, 1,0mm, 0,5mm, 0,2mm e sem desgaste. Para os exames de ultrassom foi utilizado o aparelho de ultrassom portátil Terason t3000 (Terason, divisão da Teratech Corporation, USA). Os exames foram realizados pela técnica da imersão, onde se mergulhava os espécimes e o transdutor do ultrassom em um recipiente com água. Para avaliar se havia ou não passagem da onda de ultrassom pelo tecido ósseo, em uma determinada espessura, era observada a formação de imagem de um objeto metálico posicionado atrás do osso. Conforme observado pela tabulação dos resultados ocorreu a passagem das ondas de ultrassom através do osso de espessuras 2,0mm, 1,5mm, 1,0mm, 0,5mm e 0,2mm diferentemente do ocorrido nas espessuras 4,0mm, 3,0mm, 2,5mm e sem desgaste. Houve diferença estatisticamente significante (P<0,001) entre as espessuras menores ou iguais a 2,0mm e as espessuras maiores ou iguais a 2,5mm, quanto a formação de imagem ultrassonográfica de um objeto metálico posicionado atrás do tecido ósseo. Concluímos que houve possibilidade de utilização do exame de ultrassom na avaliação através do tecido ósseo de espessuras menores ou iguais a 2,0mm. / The use of ultrasound as a complementary examination in health diagnoses is something usual and well established, mainly in the study and evaluation of diseases in soft tissue. As the consolidation and development of this method ocourred, new uses for it has been described. There are scientific reports with the possibility of the use of ultrasound for the evaluation of lesions within the bone tissue. Faced with this alternative, the aim of the present study was to evaluate the use of ultrasound for exploration through the bone tissue of different thicknesses, using a laboratory model of beef ribs, so thath would be defined the minimum required thicknesses of cortical bone for passage of the ultrasound. First we conducted an experimental trial to determine the best methodology for the study. The laboratory model used consisted of beef ribs prepared in different thicknesses. The study sample consisted of 180 ultrasound readings from 20 macerated beef ribs, each of which was examined in 9 different areas defined as, no wear, 4.0 mm, 3.0 mm, 2.5 mm, 2.0 mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm in thicknesses of the remaining bone. For ultrasound scanning was used a portable ultrasound device, Terason t3000 (Terason, a division of Teratech Corporation, USA). The examinations were performed by the technique of immersion, where the specimens and the ultrasound transductor were immersed in a water tank. To assess whether there was passage of ultrasound waves by the bone tissue in a certain thickness, it was observed the occurrence of a image formation from a metallic object that was positioned behind the bone. As noted by tabulating the results, there was passage of ultrasound waves through the bone thickness 2.0mm, 1.5mm, 1.0mm, 0.5mm and 0.2mm different from those occurred in thickness of 4.0mm, 3.0mm, 2.5mm and no wear. There was significant difference (P<0.001) between the thicknesses less than or equal to 2.0 mm and thickness greater than or equal to 2.5 mm, in the ultrasound imaging of a metallic object positioned behind the bone. We conclude that there was possibility of using the ultrasound examination in the evaluation through the bone thickness less than or equal to 2.0mm.
|
379 |
Avaliação da aplicabilidade da ultrassonografia musculoesquelética do segmento toracolombar e lombar da coluna vertebral de cães hígidos / Evaluation of the applicability of musculoskeletal ultrasound of the thoracolumbar and lumbar spine of healthy dogsLopes, Érika Rondon 15 June 2016 (has links)
Alterações na coluna vertebral de cães são comumente encontradas na rotina clínica e cirúrgica veterinária. Existem poucos estudos sobre a anatomia ultrassonográfica musculoesquelética do segmento toracolombar e lombar da coluna vertebral normal de cães. O objetivo deste trabalho foi comparar a anatomia ultrassonográfica musculoesquelética normal dos segmentos vertebrais avaliados com imagens obtidas pela ressonância magnética, tomografia computadorizada e peças anatômicas visando demonstrar a sua capacidade de identificação de estruturas. A varredura ultrassonográfica permitiu a visibilização da musculatura da região, processos articulares, processos espinhosos, ligamentos interespinhosos e ligamento amarelo na janela lombossacra. A tomografia computadorizada forneceu imagens com melhor detalhamento ósseo quando comparada ao exame ultrassonográfico. A ressonância magnética de baixo campo permitiu a identificação das mesmas estruturas que o exame ultrassonográfico acrescido da identificação do líquido cefalorraquidiano, processos transversos e melhor detalhamento dos discos intervertebrais e medula espinhal. Com o conhecimento da anatomia ultrassonográfica da região, acredita-se que lesões musculares e ligamentares possam ser identificadas. Vale salientar que em regiões onde a tomografia computadorizada e a ressonância magnética não estejam acessíveis a ultrassonografia da região pode ser uma boa alternativa para identificar possíveis alterações não visibilizadas ao exame radiográfico, ou complementar o mesmo. / Changes in the spine of dogs are usually found in clinical and surgical practices. There are few studies on musculoskeletal ultrasound anatomy of thoracolumbar and lumbar segments of the normal spine of dogs. The aim of this study was to compare normal musculoskeletal ultrasound anatomy of the vertebral segments evaluated with images obtained by magnetic resonance imaging, computed tomography and anatomical parts in order to establish its ability to identify structures. The ultrasound scan allowed visualization of the muscles of the region, articular processes, spinous process, interspinous ligament and yellow ligament in the lumbosacral window. Computed tomography provide images with better bone details when compared to ultrasound examination. Low field magnetic resonance imaging allowed the identification of the same structures as the ultrasound examination plus the identification of cerebrospinal fluid, transverse processes and better detail of the intervertebral discs and spinal cord. Knowledge of ultrasound anatomy of the region may lead to detection of muscle and ligament injuries. It is emphasized that in areas where CT and MRI are not accessible, ultrasonography of the region can be a good alternative to identify possible alterations not visualized by radiographic examination or supplement it.
|
380 |
Aplicabilidade da ultrassonografia musculoesquelética na articulação do cotovelo de cães hígidos / Applicability of musculoskeletal ultrasound in the elbow joint of healthy dogsBellegard, Gabriela Monaldo Corrá 14 December 2016 (has links)
A articulação do cotovelo é complexa e tem grande relevância clínica nos atendimentos aos pequenos animais. Esta região já foi bem explorada em pesquisas anteriores pelos métodos radiográficos e tomográficos, porém, ainda há poucos estudos relacionados à ultrassonografia. O objetivo deste estudo foi descrever a anatomia ultrassonográfica da articulação do cotovelo de cães e comparar com os achados das demais modalidades de diagnóstico por imagem. Dessa forma, demonstrar a capacidade da técnica de identificar as principais estruturas desta articulação e seu potencial uso em regiões onde a tomografia computadorizada e ressonância magnética não estiverem disponíveis. Dez animais com peso entre 5 kg e 15 kg foram radiografados e selecionados para o estudo ultrassonográfico. O protocolo para a descrição ultrassonográfica foi estabelecido dividindo-se as áreas da articulação em porções proximal, média e distal; e faces lateral, cranial, medial e caudal. A avaliação foi realizada nos planos longitudinais, transversais e oblíquos e as estruturas musculoesqueléticas foram descritas conforme sua arquitetura, ecogenicidade e ecotextura. Como parte complementar deste estudo um dos animais foi submetido aos exames de tomografia computadorizada e ressonância magnética. Em relação às estruturas visibilizadas, o exame ultrassonográfico foi eficiente para as análises muscular, tendínea e ligamentar. Os contornos ósseos e regiões sede de alterações de importância clínica, como processo coronóide medial da ulna e processo ancôneo também foram visibilizados, porém de forma limitada. O conhecimento prévio da anatomia ultrassonográfica normal da articulação do cotovelo, assim como das vantagens e limitações da técnica, permitem a realização de estudos subsequentes, relacionados às possíveis identificações de alterações musculoesqueléticas. / The elbow is a complex joint and has a great clinical relevance at the small animal medicine care. Previous research of this region has been explored using radiographic and tomographic methods, however, there are few studies related to ultrasonography. The aim of this study was to describe the ultrasonographic anatomy of the elbow joint of dogs and compare it with the findings of other types of diagnostic imaging. Thus, demonstrate the ability of this technique to identify the main structures of this joint and its potential use in regions where computed tomography and magnetic resonance imaging are not available. Ten animals weighing between 5 kg and 15 kg were radiographed and selected to the ultrasonographic study. The protocol was established for the ultrasonographic description dividing the articular areas in proximal, middle and distal; and lateral cranial, medial, and caudal faces. The approach was made in longitudinal, transverse and oblique planes and the musculoskeletal structures were described according to the architecture, echogenicity and echotexture. Computed tomography and magnetic resonance scans were made in one animal as an additional part of this study. Regarding visualized structures, the ultrasonography was efficient for muscle, tendon and ligament analysis. Bone contours and regions that have clinical significance such as medial coronoid process and anconeus process were identified, but with limited access. Prior knowledge of the normal sonographic anatomy of the elbow joint as well as the technical advantages and limitations allow pursuing further studies related to the possible identification of musculoskeletal disorders.
|
Page generated in 0.0415 seconds