1

Underground distribution cable incipient fault diagnosis system

Jaafari Mousavi, Mir Rasoul 25 April 2007 (has links)
This dissertation presents a methodology for an efficient, non-destructive, and online incipient fault diagnosis system (IFDS) to detect underground cable incipient faults before they become catastrophic. The system provides vital information to help the operator with the decision-making process regarding the condition assessment of the underground cable. It incorporates advanced digital signal processing and pattern recognition methods to classify recorded data into designated classes. Additionally, the IFDS utilizes novel detection methodologies to detect when the cable is near failure. The classification functionality is achieved through employing an ensemble of rule-based and supervised classifiers. The Support Vector Machines, designed and used as a supervised classifier, was found to perform superior. In addition to the normalized energy features computed from wavelet packet analysis, two new features, namely Horizontal Severity Index, and Vertical Severity Index are defined and used in the classification problem. The detection functionality of the IFDS is achieved through incorporating a temporal severity measure and a detection method. The novel severity measure is based on the temporal analysis of arrival times of incipient abnormalities, which gives rise to a numeric index called the Global Severity Index (GSI). This index portrays the progressive degradation path of underground cable as catastrophic failure time approaches. The detection approach utilizes the numerical modeling capabilities of SOM as well as statistical change detection techniques. The natural logarithm of the chronologically ordered minimum modeling errors, computed from exposing feature vectors to a trained SOM, is used as the detection index. Three modified change detection algorithms, namely Cumulative Sum, Exponentially Weighted Moving Averages, and Generalized Likelihood Ratio, are introduced and applied to this application. These algorithms determine the change point or near failure time of cable from the instantaneous values of the detection index. Performance studies using field recorded data were conducted at three warning levels to assess the capability of the IFDS in predicting the faults that actually occurred in the monitored underground cable. The IFDS presents a high classification rate and satisfactory detection capability at each warning level. Specifically, it demonstrates that at least one detection technique successfully provides an early warning that a fault is imminent.
2

Estudo de viabilidade de um sistema de monitoramento de baixo custo para os sistemas de distribuição reticulados subterrâneos / Viability Study of a Low Cost Monitoring System for Underground Power Distribution

Barreto, Gustavo de Andrade 26 February 2010 (has links)
Este trabalho apresenta um estudo de viabilidade de um Sistema de Monitoramento de Baixo Custo (SMBC), por meio da observação de ganhos operacionais no caso de serem agregadas funções de monitoramento e controle aos relés eletrônicos dos protetores (equipamentos religadores do sistema de distribuição reticulado), visando a melhoria da qualidade no fornecimento de energia elétrica através da redução dos tempos de reação das concessionárias às falhas, do aumento da vida útil dos equipamentos e redução dos custos operacionais. Um relé para protetores de rede com características apropriadas foi desenvolvido pela empresa Futura, testado nos laboratórios do IEE/USP e instalado em campo, dentro do Programa de Pesquisa e Desenvolvimento da ANEEL com a concessionária Companhia Energética de Brasília. A operação foi acompanhada por 13 meses avaliando as novas possibilidades de operação remota, os benefícios para a concessionária e os ganhos sociais. Os benefícios do uso do sistema, os ganhos operacionais, gerenciais e sociais, são relatados constatando a viabilidade técnica e econômica da adoção do sistema. Ao final, recomendações para a continuidade da pesquisa são feitas / This work presents a viability study for a Low-cost Monitoring System (SMBC), through the examination of the operational improvements on electrical network distribution systems when new functions are added to network protectors relays allowing remote monitoring and control using typical automation protocols. The improvements on energy supply quality by reducing response times to failures, extension of equipment life and pro-active actions are also evaluated. A network protector relay with the new features have been developed by Futura Automação and tested in the IEE/USP laboratories, within a Research & Development program promoted by the national electrical energy regulator, ANEEL, and the utility Companhia Energética de Brasília (CEB). The 7 new relays have been installed for field operation and for evaluation of the new possibilities of operation and possible gains for the utility took place in 13 months of continuous operation. The benefits, operational improvements, management and social gains are described assuring the technical and economical viability of the system. Recommendations for future research are made
3

Estudo de viabilidade de um sistema de monitoramento de baixo custo para os sistemas de distribuição reticulados subterrâneos / Viability Study of a Low Cost Monitoring System for Underground Power Distribution

Gustavo de Andrade Barreto 26 February 2010 (has links)
Este trabalho apresenta um estudo de viabilidade de um Sistema de Monitoramento de Baixo Custo (SMBC), por meio da observação de ganhos operacionais no caso de serem agregadas funções de monitoramento e controle aos relés eletrônicos dos protetores (equipamentos religadores do sistema de distribuição reticulado), visando a melhoria da qualidade no fornecimento de energia elétrica através da redução dos tempos de reação das concessionárias às falhas, do aumento da vida útil dos equipamentos e redução dos custos operacionais. Um relé para protetores de rede com características apropriadas foi desenvolvido pela empresa Futura, testado nos laboratórios do IEE/USP e instalado em campo, dentro do Programa de Pesquisa e Desenvolvimento da ANEEL com a concessionária Companhia Energética de Brasília. A operação foi acompanhada por 13 meses avaliando as novas possibilidades de operação remota, os benefícios para a concessionária e os ganhos sociais. Os benefícios do uso do sistema, os ganhos operacionais, gerenciais e sociais, são relatados constatando a viabilidade técnica e econômica da adoção do sistema. Ao final, recomendações para a continuidade da pesquisa são feitas / This work presents a viability study for a Low-cost Monitoring System (SMBC), through the examination of the operational improvements on electrical network distribution systems when new functions are added to network protectors relays allowing remote monitoring and control using typical automation protocols. The improvements on energy supply quality by reducing response times to failures, extension of equipment life and pro-active actions are also evaluated. A network protector relay with the new features have been developed by Futura Automação and tested in the IEE/USP laboratories, within a Research & Development program promoted by the national electrical energy regulator, ANEEL, and the utility Companhia Energética de Brasília (CEB). The 7 new relays have been installed for field operation and for evaluation of the new possibilities of operation and possible gains for the utility took place in 13 months of continuous operation. The benefits, operational improvements, management and social gains are described assuring the technical and economical viability of the system. Recommendations for future research are made
4

Automação da redução de perdas técnicas nos sistemas reticulados de distribuição utilizando redes neurais artificiais em redes inteligentes (smart grid). / Automation of the reduction of technical in reticulated distribution systems using artificial neural netwarks, te4chnical losses power factor.

Cambraia, Mario Sergio 05 December 2017 (has links)
Este trabalho apresenta a metodologia, o desenvolvimento e testes de um sistema de automação independente, baseado em Redes Neurais Artificiais, para redução de perdas técnicas em redes de distribuição subterrâneas reticuladas por meio do controle ótimo dos bancos de capacitores presentes na rede. A metodologia proposta contempla funcionalidades típicas de Redes Inteligentes, incluindo soluções práticas para o posicionamento de sensores de corrente em redes subterrâneas, coleta de medições de campo e transmissão para o Centro de Operação da Distribuição e controle em tempo real dos equipamentos de campo (bancos de capacitores). Portanto este trabalho consiste na implementação da solução através de baixo custo de investimento na mitigação do controle do fator de potência nos pontos de entrega ao consumidor, sendo que com isto ocorrem melhorias nos indicadores de qualidade e confiabilidade atendendo aos requisitos regulamentares e contratuais de fornecimento das distribuidoras. Para validação da metodologia proposta, foram utilizados os dados da concessionária de energia AES Eletropaulo sobre a Rede de Distribuição Subterrânea Reticulada do centro da cidade de São Paulo. As etapas da metodologia proposta e os principais aspectos do desenvolvimento do sistema são também descritos, bem como os testes realizados para comprovação dos resultados e validação do sistema. / This work presents the methodology, development and testing of an independent automation system, based on Artificial Neural Networks, to reduce technical losses in reticulated underground distribution networks by means of the optimal control of the capacitor banks present in the network. The proposed methodology includes typical functionalities of Intelligent Networks, including practical solutions for the positioning of current sensors in underground networks, collection of field measurements and transmission to the Distribution Operation Center and real-time control of field equipment (capacitors banks). Therefore, this work consists in the implementation of the solution through a low cost of investment in the mitigation of the control of the power factor in the points of delivery to the consumer, and with this there are improvements in the indicators of quality and reliability taking into account the regulatory and contractual requirements of supply of the distributors. The energy concessionaire AES Eletropaulo had great participation in this research project, providing the necessary data of the Reticulated Underground Distribution Network of the city center of São Paulo. The steps of the proposed methodology and the main aspects of system development are also described, as well as the tests performed to prove the results and validate the system.
5

Automação da redução de perdas técnicas nos sistemas reticulados de distribuição utilizando redes neurais artificiais em redes inteligentes (smart grid). / Automation of the reduction of technical in reticulated distribution systems using artificial neural netwarks, te4chnical losses power factor.

Mario Sergio Cambraia 05 December 2017 (has links)
Este trabalho apresenta a metodologia, o desenvolvimento e testes de um sistema de automação independente, baseado em Redes Neurais Artificiais, para redução de perdas técnicas em redes de distribuição subterrâneas reticuladas por meio do controle ótimo dos bancos de capacitores presentes na rede. A metodologia proposta contempla funcionalidades típicas de Redes Inteligentes, incluindo soluções práticas para o posicionamento de sensores de corrente em redes subterrâneas, coleta de medições de campo e transmissão para o Centro de Operação da Distribuição e controle em tempo real dos equipamentos de campo (bancos de capacitores). Portanto este trabalho consiste na implementação da solução através de baixo custo de investimento na mitigação do controle do fator de potência nos pontos de entrega ao consumidor, sendo que com isto ocorrem melhorias nos indicadores de qualidade e confiabilidade atendendo aos requisitos regulamentares e contratuais de fornecimento das distribuidoras. Para validação da metodologia proposta, foram utilizados os dados da concessionária de energia AES Eletropaulo sobre a Rede de Distribuição Subterrânea Reticulada do centro da cidade de São Paulo. As etapas da metodologia proposta e os principais aspectos do desenvolvimento do sistema são também descritos, bem como os testes realizados para comprovação dos resultados e validação do sistema. / This work presents the methodology, development and testing of an independent automation system, based on Artificial Neural Networks, to reduce technical losses in reticulated underground distribution networks by means of the optimal control of the capacitor banks present in the network. The proposed methodology includes typical functionalities of Intelligent Networks, including practical solutions for the positioning of current sensors in underground networks, collection of field measurements and transmission to the Distribution Operation Center and real-time control of field equipment (capacitors banks). Therefore, this work consists in the implementation of the solution through a low cost of investment in the mitigation of the control of the power factor in the points of delivery to the consumer, and with this there are improvements in the indicators of quality and reliability taking into account the regulatory and contractual requirements of supply of the distributors. The energy concessionaire AES Eletropaulo had great participation in this research project, providing the necessary data of the Reticulated Underground Distribution Network of the city center of São Paulo. The steps of the proposed methodology and the main aspects of system development are also described, as well as the tests performed to prove the results and validate the system.
6

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
7

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
8

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
9

Diagnóstico de curtos-circuitos a partir da alocação otimizada de medidores em um sistema de distribuição subterrâneo / Diagnostic short-circuits from the optimized allocation meters in a underground distribution system

Festa, Alexandre Vinícius 12 February 2015 (has links)
O monitoramento e diagnóstico, com a consequente localização dos curtos-circuitos em Sistemas de Distribuição (SD), fazem parte de um processo complexo, exigindo esforços e agilidade das equipes técnicas de manutenção das concessionárias de energia elétrica. Quando se trata de um SD Subterrâneo (SDS), a complexidade de localização das faltas aumenta, pois não é possível realizar a inspeção visual. Por este motivo, desenvolver e aprimorar métodos para monitorar, classificar e localizar as situações de faltas em SD tem sido de relevante interesse para a comunidade técnico-científica nos últimos anos. Neste contexto, apresenta-se nesta pesquisa um método para processar as informações necessárias para classificar e localizar a ocorrência de um curto-circuito (monofásico, bifásico e/ou trifásico, com e/ou sem o envolvimento da terra) em um SDS. O processamento das informações foi realizado por meio da observação da propagação dos afundamentos de tensão, decorrentes de curtos-circuitos passíveis de ocorrência no SDS, e pela alocação de um número reduzido de medidores, permitindo a classificação e localização precisa da falta. Um dos diferenciais da metodologia proposta é que esta utiliza somente os valores eficazes das tensões trifásicas, registradas em medidores estrategicamente alocados, para indicação da área afetada e classificação das fases envolvidas. A metodologia é baseada no emprego de redes neurais artificiais. Os resultados encontrados são promissores, indicando a aplicabilidade da metodologia proposta. / The monitoring and diagnostics, with the consequent localization of short circuits in Distribution Systems (DS), are part of a complex process, requiring efforts and agility of the technical teams of maintenance of electric utilities. In the case of an underground DS (UDS), the location of faults complexity increases, because it is not possible to perform visual inspection. For this reason, develop and improve methods to monitor, sort and locate the fault situations in DS has been of relevant interest to the technical-scientific community in recent years. In this context, this study presents a method for processing the information required to classify and locate the occurrence of a short circuit (single phase, biphasic and / or phase with and / or without the involvement of the earth) on a UDS. The information processing was carried out by observing the propagation of voltage sags, caused by short circuits that may occur in the UDS, and the allocation of a few meters, allowing classification and precise location of the fault. One of the proposed methodology differentials is that it uses only the RMS values of the three-phase voltages, registered in strategically located meters, for indicating the affected area and classification of the phases involved. The methodology is based on the use of artificial neural networks. The results found are promising, indicating the applicability of the proposed methodology.
10

Diagnóstico de curtos-circuitos a partir da alocação otimizada de medidores em um sistema de distribuição subterrâneo / Diagnostic short-circuits from the optimized allocation meters in a underground distribution system

Alexandre Vinícius Festa 12 February 2015 (has links)
O monitoramento e diagnóstico, com a consequente localização dos curtos-circuitos em Sistemas de Distribuição (SD), fazem parte de um processo complexo, exigindo esforços e agilidade das equipes técnicas de manutenção das concessionárias de energia elétrica. Quando se trata de um SD Subterrâneo (SDS), a complexidade de localização das faltas aumenta, pois não é possível realizar a inspeção visual. Por este motivo, desenvolver e aprimorar métodos para monitorar, classificar e localizar as situações de faltas em SD tem sido de relevante interesse para a comunidade técnico-científica nos últimos anos. Neste contexto, apresenta-se nesta pesquisa um método para processar as informações necessárias para classificar e localizar a ocorrência de um curto-circuito (monofásico, bifásico e/ou trifásico, com e/ou sem o envolvimento da terra) em um SDS. O processamento das informações foi realizado por meio da observação da propagação dos afundamentos de tensão, decorrentes de curtos-circuitos passíveis de ocorrência no SDS, e pela alocação de um número reduzido de medidores, permitindo a classificação e localização precisa da falta. Um dos diferenciais da metodologia proposta é que esta utiliza somente os valores eficazes das tensões trifásicas, registradas em medidores estrategicamente alocados, para indicação da área afetada e classificação das fases envolvidas. A metodologia é baseada no emprego de redes neurais artificiais. Os resultados encontrados são promissores, indicando a aplicabilidade da metodologia proposta. / The monitoring and diagnostics, with the consequent localization of short circuits in Distribution Systems (DS), are part of a complex process, requiring efforts and agility of the technical teams of maintenance of electric utilities. In the case of an underground DS (UDS), the location of faults complexity increases, because it is not possible to perform visual inspection. For this reason, develop and improve methods to monitor, sort and locate the fault situations in DS has been of relevant interest to the technical-scientific community in recent years. In this context, this study presents a method for processing the information required to classify and locate the occurrence of a short circuit (single phase, biphasic and / or phase with and / or without the involvement of the earth) on a UDS. The information processing was carried out by observing the propagation of voltage sags, caused by short circuits that may occur in the UDS, and the allocation of a few meters, allowing classification and precise location of the fault. One of the proposed methodology differentials is that it uses only the RMS values of the three-phase voltages, registered in strategically located meters, for indicating the affected area and classification of the phases involved. The methodology is based on the use of artificial neural networks. The results found are promising, indicating the applicability of the proposed methodology.