• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 371
  • 266
  • 73
  • 73
  • 38
  • 36
  • 22
  • 10
  • 10
  • 9
  • 8
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 1105
  • 1105
  • 231
  • 218
  • 174
  • 164
  • 150
  • 132
  • 131
  • 102
  • 92
  • 91
  • 88
  • 84
  • 84
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
711

Leveraging Halogen Interactions for the Improved Performance of Reverse Osmosis Membranes

Michael D Toomey (9761183) 11 December 2021 (has links)
<div> Here, the quartz crystal microbalance with dissipation monitoring (QCM-D) is employed to explore the interaction of the various free oxidant species with condensed PA model membranes in order to improve our understanding of how the interaction with these species affects rates of membrane chlorination and alter membrane structure. Molecular-scale mass uptake and changes in the dissipative nature of the of the model membranes as measured by the QCM is correlated to performance changes in interfacially polymerized PA reverse osmosis (RO) membranes. Leveraging newly gained insights from these measured interactions, new strategies are explored to improve flux and chlorine resistance using novel membrane structure and chemistry.<br></div>
712

Studie rekonstrukce úpravny bazénových vod letního koupaliště Břeclav / The study of the reconstruction of the pool water treatment plant of the summer swimming pool Břeclav

Urban, Jaromír January 2020 (has links)
The subject of the diploma thesis is to introduce the problems of communal spas, namely the treatment of water for swimming pools. Following is a proposal of reconstruction of the treatment plant for a real, operated area of the summer swimming pool. The thesis is divided into theoretical and practical part. At the beginning of the theoretical part I make research of the history of balneology, the effects of bathing and swimming on the human body, possible resources for spa purposes and hygiene requirements for these waters. I also describe commonly used methods of treatment of swimming pool water. In the practical part I first describe the summer swimming pool in the town of Břeclav. There is a description of the swimming pool, its history and equipment. In the next chapter I present the currently operated technological line. Based on a personal visit, the next chapter evaluates the technical condition of the plant. Based on this evaluation, a new technological line for treatment of swimming pool water of the Břeclav summer swimming pool is proposed.
713

Využití metody kapacitní deionizace pro úpravu vody / Use of capacitive deionization method for water treatment

Švábová, Martina January 2021 (has links)
Capacitive deionization technologies have gained significant attention in recent years. The development and availability of a variety of materials have enabled the growth of research on electrosorption, which makes capacitive deionization increasingly attractive. This technology has a wide range of applications, such as softening, desalination and selective removal, each of which has been the focus of the experimental part of this work. The theoretical part is devoted to the issue of functioning of capacitive deionization, electrode material and especially the specific application. Water desalination is a major issue, given the global shortage of drinking water and the possibility of using capacitive deionization as a competitive method to conventional desalination methods. Conversely, softening and selective removal of ions can pose everyday problems both in the treatment of drinking water or pre-treatment of industrial water and in the treatment of wastewater. In this diploma thesis, it was proved that the method of capacitive deionization can be used to solve all the above problems. Although capacitive deionization is not a commercially available technology in the Czech Republic yet, it can be expected to be used more and more in the future.
714

Understanding the Impacts of Harmful Algal Blooms on Biologically-Active Filtration for Drinking Water Treatment

Jeon, Youchul January 2020 (has links)
No description available.
715

Agregační reakce chitosanu využitelné při úpravě pitné vody. / Aggregation reactions of chitosan in drinking water treatment

Leskovjanová, Jana January 2008 (has links)
The diploma thesis deals with treatment of surface waters containing humic substances. The most often used method of surface water treatment is coagulation with subsequent separation of aggregates. In this study, only perikinetic coagulation phase was studied. It is the phase when aggregates are formed by the Brownian motion only, i.e. without mixing. Separation of the formed aggregates was made by centrifugation. Coagulation tests were made under the laboratory conditions with model humic water. Humic substances were added from a concentrate, which was taken from a natural peatbog. The influence of temperature on the coagulation process was studied, ranging from 5 to 22 °C. Chitosan (natural biopolymer) was used as coagulant. In present, it is not used in Czech water treatment practice yet. No effect of temperature was observed when chitosan was used as coagulant. Influence of temperature was also studied with the use of aluminium and ferrous sulphates, which are used in common praxis as coagulation reagents. Influence of the temperature was observed and is in agreement with previously reported data of pilot-plant experiments by other researchers. Spectroscopic methods were used to evaluate the coagulation efficiency and determine residual concentration of aluminium and ferrous coagulant. Chemical oxygen demand (COD) was determined for optimal doses. At first, coagulation tests were made under the laboratory temperature. This tests determined optimal aggregation time and optimal coagulant dose under low temperature. Afterwards, all coagulants used were compared at given temperatures.
716

Studium adsorpce přirozených organických látek na aktivním uhlí při úpravě pitné vody / Adsorption of natural organic matter (NOM) on granular activated carbon in the treatment of drinking water

Le Duc, Duy January 2008 (has links)
In the first part of this thesis the methodic of lab trial was studied, which will be useful for studying adsorption of natural organic matter by activated carbon. As an optimal method of testing adsorption characters jar testing was chosen. Again as an indicator of organic contamination, it was decided to use permanganate chemical oxygen demand (in Czech CHSKMn) will be used. In the second part of this thesis the adsorption characters of eight types of granular activated carbon were studied. Those granular activated carbon came from two world produces, from company NORIT five type of granular activated carbon were tested: NORIT GAC 1020, NORIT PK 1-3, NORIT GAC 1240, NORIT ROW 0.8 SUPRA a TOD NORIT ROX 0.8 and from company Chemviron Carbon three types of granular activated carbon were tested: F100 FE11120A, F400 FE11210A a TL830 FE2028B. Batch kinetic tests of natural organic matter adsorption were conducted with all types of granular activated carbon at first. For description of sorption not only the batch kinetic tests and duration needed for setting equilibrium were observed, but also the process decreasing of concentration of natural organic matters to the value of equilibrium concentration known as adsorption equilibrium was followed.
717

Optimalizace provozních parametrů na úpravně vody Bzenec-Přívoz / Optimization of operating parameters in drinking water treatment plant in Bzenec-Přívoz

Sukopová, Martina January 2010 (has links)
Water treatment plant Bzenec Přívoz represents important supply of potable water for Hodonín district. After a longtime operation it was in 2008-2010 reconstructed in order to make water treatment technology more effective. The basic step was dividing technology into one stage and two stage water treatment for particular spring areas of ground water. The character of raw water requires effective removal of iron and manganese, therefore intensification and optimization of operating parameters were the purposes of the project. Installation of new aerators and hyperboloid stirrers in flocculation tank required an operating tests for proving of high technological efficiency while the operating costs were decreased. The water treatment process was completly automatized, which made the operation easy and minimized human element impact. Results of the reconstruction are more effective water treatment and a distinct decrease of operating costs.
718

Odstraňování vybraných kovů z vody / Removal of selected metals from the water

Pěkný, Mojmír January 2013 (has links)
In my thesis I focused on the problem of removal of some heavy metals from water. Heavy metals cause deterioration of quality of water sources and bring about a need of complicated water treatment technologies. In particular it is the case of mercury, arsenic, cadmium, lead, chromium and nickel. This diploma thesis focuses on the utilization of adsorption using suitable adsorption materials to reduce concentrations of nickel in drinking water. At the same time it investigates the effectiveness of these materials in the process of removing iron and manganese from water. The first part of my thesis presents an overview of these metals. I write about their occurrence, its forms, properties and significance. The second part of the work focuses on the laboratory observations of the effectiveness in removing iron, manganese and nickel from water. The description of the used sorptive materials is also included.
719

Možnosti inovace procesu úpravy vody / Water Treatment Plants Innovation Opportunities

Zelený, Zdeněk January 2014 (has links)
This master´s thesis deals with the possibilities of innovation process water treatment. Specifically, to explore the use of sodium water glass and nanoiron in removing heavy metals from raw water at the drinking water treatment. For the comparison was used traditionally used coagulant, particularly liquid aluminum sulfate. The introductory part deals with the possibility of modifying the surface water during the treatment process such water into potable water. This chapter is a description of the quality of raw water used, then the description of currently used separation processes. Furthermore, they are described and commonly used types of treatment plants. Conclusion The introductory section deals with traditional coagulants and form a suspension. Another part of this master´s thesis has been devoted to the possibilities of innovation in the treatment of raw waters as drinking water, describes the options and features of the use of water glass and nanoiron. The following section describes the experimental part of this thesis. It is followed by the experimental results. The last chapter summarizes the acquired knowledge and commented on the measured values of the experimental part. This work also shows several specific projects using innovative technologies presented.
720

Odkanalizování odpadních vod z průmyslového areálu ve městě Hulín / Drainage of waste water from the industrial area in Hulin city

Dohnal, Radek January 2015 (has links)
The subject of this thesis is to implement the passport of sewer system installation, technical assessment and evaluation of the technical condition of the entire sewer network in the industrial area, along with focus and plotting the current leadership of the sewerage system. It was also developed a hydraulic model of the entire solution sewer system. In the second part of the study is a proposal for an appropriate treatment system of wastewater. It was also developed a hydraulic model of the entire solution sewer system. In the second part of the study is a proposal for an appropriate treatment system of wastewater. In conclusion there is a financial assessment and comparison of different variants cleaning system in terms of investment and operating costs.

Page generated in 0.0702 seconds