• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Study of Deflection of Single and Multi-Storey Light Frame Wood Shear Walls

Bagheri, Mohammad Mehdi 01 August 2018 (has links)
The behavior of wood shear walls has been the focus of researchers and engineers for many years due to their availability in the North American construction landscape. A review of the established literature showed that most of the research have focused on the shear wall behavior as a whole with no investigation specifically targeting the individual components of its deflection. Also, little to no attention has been given to the investigation of the cumulative effects especially when the out-of-plane diaphragm stiffness is considered. The current study aims at investigating the effects of construction details variation on the behavior of the shear walls and evaluating whether the current deflection equation, as per wood design standard (CSA 2014) can adequately predict the overall wall stiffness. A total of 27 full-scale single-storey walls, with different construction details and aspect ratios, were tested under either static or monotonic (as both are the same) loading. The parameters that were varied in the testing were the stud size and spacing, nail diameter and spacing, sheathing panel type and thickness and hold-down anchoring system/type. For the two-storey walls, two different loading cases were considered, namely where the load was applied at the top or bottom storey only. The results showed that the strength and stiffness correlated almost directly to the inverse of the wall aspect ratio. There was no clear trend when considering the effect of the walls’ aspect ratios on ductility. Unexpectedly, walls with aspect ratios not permitted according to the wood design standard (4:1 and 6:1) followed similar strength and stiffness trends and had sufficient ductility ratios as those with smaller aspect ratios. This observation explains in part some of the discrepancies found between engineering calculations and behavior of actual building with light frame wood shear walls. Significant discrepancies were found when comparing the various deflection constituent with those estimated using the design expression. Adding more end studs and changing the size of the studs had no significant effect on the overall wall capacity and little effect on its stiffness. Reducing the stud spacing had, as expected, no effect on the wall capacity; however, the results showed that the bending stiffness was affected by the overall number of studs in the wall and not solely by the end studs. Shear walls sheathed with plywood panels exhibits slightly higher peak load and initial stiffness than those with OSB, which was mainly attributed to the greater panel thickness, and possibly density, of the plywood. Both sheathing types provided similar levels of ductility, as expected. Thicker sheathing increased the capacity and stiffness of the wall with no significant change observed in ductility ratio. The wall strength was significantly affected by the nail diameter and nail spacing, but no difference was observed when the nail edge/end distance was increased. The results also showed that discrete hold-down system behaved in a non-linear manner with a significantly greater initial stiffness than that assumed in design. The study also showed that having continuous hold-down connections has a positive effect on the capacity, stiffness and ductility of the wall when compared with discrete hold-downs. Having no hold-down adversely affects the wall capacity and stiffness, but did not affect the ductility of the wall. For the two-storey walls, the deflection estimated based on the cumulative effect assumption showed slight differences when compared with that observed in the experimental study. It was observed that the majority of the cumulative effect stems from the rigid body rotation due to deformation in the hold-down devices. A Computer shear wall model (through SAP2000) was developed using linear “frame” and “membrane” elements for the framing and sheathing members, respectively, whereas the sheathing to framing nails and hold-down were modeled using nonlinear springs. It was found that the model was capable of predicting the peak load, ultimate deflection and yield loads with reasonable accuracy, but overestimated the initial stiffness and ductility of the walls. In general, when the force-displacement curves were compared it was evident that the model was capable of predicting the wall behaviour with reasonable accuracy. When investigating the cumulative effects using the model, the results clearly showed that the assumption of cumulative effects due to rigid body rotation is valid for stacked shearwalls with no consideration for the floor diaphragm. The effect of the diaphragm on the behavior of the shear walls, in particular its out-of-plane rigidity was simulated by modeling the floors as beam. The out of plane stiffness of the shear walls was investigated for idealized (infinitely stiff or flexible) as well as “realistic”. The results showed reductions in the shearwall deflection in the magnitude of approximately 80% considering the out of plane rigidity of the diaphragm. It was also concluded that considering conservative estimates of out of plane stiffness might lead to a very significant reduction in deflection and that assuming the floor diaphragm to be infinitely rigid out of plan seems reasonable. For diaphragms supported on multiple panels further reduction in the deflection was observed. More work, particularly at the experimental level, is needed to verify the finding obtained in the numerical investigation related to the effect of out of plane diaphragm stiffness.
2

Analytical Modeling of Wood-Frame Shear Walls and Diaphragms

Judd, Johnn Paul 18 March 2005 (has links) (PDF)
Analytical models of wood-frame shear walls and diaphragms for use in monotonic, quasi-static (cyclic), and dynamic analyses are developed in this thesis. A new analytical model is developed to accurately represent connections between sheathing panels and wood framing members (sheathing-to-framing connections) in structural analysis computer programs. This new model represents sheathing–to–framing connections using an oriented pair of nonlinear springs. Unlike previous models, the new analytical model for sheathing-to-framing connections is suitable for both monotonic, cyclic, or dynamic analyses. Moreover, the new model does not need to be scaled or adjusted. The new analytical model may be implemented in a general purpose finite element program, such as ABAQUS, or in a specialized structural analysis program, such as CASHEW. The analytical responses of several shear walls and diaphragms employing this new model are validated against measured data from experimental testing. A less complex analytical model of shear walls and diaphragms, QUICK, is developed for routine use and for dynamic analysis. QUICK utilizes an equivalent single degree of freedom system that has been determined using either calibrated parameters from experimental or analytical data, or estimated sheathing-to-framing connection data. Application of the new analytical models is illustrated in two applications. In the first application, the advantages of diaphragms using glass fiber reinforced polymer (GFRP) panels in conjunction with plywood panels as sheathing (hybrid diaphragms) are presented. In the second application, the response of shear walls with improperly driven (overdriven)nails is determined along with a method to estimate strength reduction due to both the depth and the percentage of total nails overdriven.

Page generated in 0.0847 seconds