Return to search

Análise de parâmetros eletromiográficos e cinemáticos durante teste incremental de corrida: Priscila de Brito Silva. -

Made available in DSpace on 2014-06-11T19:22:52Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-03-11Bitstream added on 2014-06-13T19:28:21Z : No. of bitstreams: 1
silva_pb_me_rcla.pdf: 790741 bytes, checksum: d5249659f04bcedba18543a60ee45546 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente estudo teve como objetivo verificar se as intensidades do LFEMG e do ponto de quebra são semelhantes e se há diferença no valor do índice, calculando-se o RMS em intervalos referentes a cinco segundos ou ao ciclo de passada e estudar o comportamento da freqüência de passada (FP), amplitude (RMS) e freqüência da atividade eletromiográfica nos período pré (RMS-PRE, FM-PRE) e pós contato (RMS-PRE, FM-POS) dos músculos íleocostal (IC), reto femoral (RF), vasto lateral (VL), vasto medial (VM), bíceps femoral (BF), tibial anterior (TA) e gastrocnêmio lateral (GL), bem como da co-ativação dos músculos RF/BF, VL/BF, VM/BF e GL/TA nos períodos pré (PRE) e póscontato (POS) ao longo de um teste incremental, considerando as intensidades absolutas e quatro intensidades relativas: inicial (IIN), equivalente ao LFEMG (ILF), 15% abaixo (IAB) e 15% acima (IAC) do LFEMG. Onze voluntários foram submetidos a um teste incremental de corrida até exaustão voluntária. Os valores de RMS foram obtidos de duas formas, a cada cinco segundos do intervalo de corrida e a cada ciclo de passada. O LFEMG e o ponto de quebra foram determinados. Não houve diferenças significantes entre os valores dos índices obtidos pelas duas formas de análise nem entre os músculos. Entretanto, foi evidenciado que os valores de LFEMG foram maiores do que os do ponto de quebra apenas quando determinados pelos valores de RMS obtidos nos ciclos de passada. As velocidades relativas obtidas foram 9,2±0,4 km.h-1 na IAB, 10,6±0,7 km.h-1 na LFEMG e 12,3±0,5 km.h-1 na IAC. A partir dos 11 km.h-1 a FP, a RMS-PRE para o músculo IC e a RMS-POS para os músculos VL e VM apresentaram aumento. Nas intensidades relativas, houve aumento dos valores da FP, da RMS-PRE para os músculos BF, TA e GL, da RMS-POS e FM-POS para o músculo GL a partir da ILF. As correlações foram significantes para FP e FM-PRE do VL... / The aim of the present study was to verify whether eletromyographic fatigue threshold (EMGFT) and breakpoint intensities were similar and whether there is differences in the speed value between these indexes when calculated considering five seconds intervals or referent to stride cycle and study stride frequency (SF), amplitude and frequency of electromyographic activity behaviors on pre (PRE) and post (POS) contact periods for iliocostalis (IC), rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius lateralis (GL), and co-activation ratio of RF/BF, VL/BF, VM/BF and GL/TA on PRE and POST periods during an incremental running protocol, considering absolute intensities and four relative intensities: initiail (IIN), equivalent to EMGFT (IFT), 15% below (IBE) and 15% above (IAB) EMGFT. Eleven males performed an incremental running test to exhaustion. RMS values were obtained every five seconds and during stride cycles of each running stage. EMGFT and breakpoint were determined for all muscles. There were no significant differences between two different indexes when calcula values obtained RMS calculation nor among different muscles. However, the EMGFT values were greater than breakpoint values when determined using RMS calculated for stride cycles, with no difference when obtained every five seconds. Relative intensities obtained were 9.2±0.4 km... (Complete abstract click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/87442
Date11 March 2009
CreatorsSilva, Priscila de Brito [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Gonçalves, Mauro [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format176 f. : il., tabs.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0028 seconds