Return to search

Análise fotoelástica da influência do carregamento e do comprimento na distribuição de tensão em dois sistemas de implantes dentários / Photoelastic analysis of the influence of loading and length of the distribution of tension in two systems of dental implants

Orientador: José Ricardo de Albergaria Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T21:59:25Z (GMT). No. of bitstreams: 1
Figueiredo_EvandroPortela_M.pdf: 2256697 bytes, checksum: bfe81580a0631a9ffe94d04bf2f85d23 (MD5)
Previous issue date: 2012 / Resumo: O objetivo do presente estudo foi avaliar, comparativamente, in vitro, o efeito de diferentes sistemas de implantes, curtos e longos, sob carregamento axial e oblíquo, na distribuição de tensões em modelos fotoelásticos. Foi confeccionado 16 modelos fotoelásticos em resina (Resina Flexível GIII CMR-201 e endurecedor CME-252/ Polipox® Indústria e Comércio Ltda, São Paulo, SP, Brasil), com dimensões de 40 X 50 X 12mm, contendo implantes de sistemas e comprimentos diferentes. Os modelos foram distribuídos em quatro grupos: Grupo I (n=4) - Implante Neodent (longo) 5x11mm; Grupo II (n=4) - Implante Bicon (longo) 5x11mm; Grupo III (n=4) - Implante Neodent (Curto) 5x6mm; Grupo IV (n=4) - Implante Bicon (Curto) 5x6mm. Foram cimentadas aos conectores protéticos (3,5mm de altura), 4 coroas protéticas fabricadas com liga de cromo-cobalto. Para os implantes curtos a prótese apresentou as dimensões de 13mm de altura, 10mm no sentido mésio-distal e 8mm no sentido vestíbulo-lingual. As próteses para os implantes longos apresentaram as dimensões de 8mm de altura, 10mm no sentido mésio-distal e 8mm no sentido vestíbulo-lingual. Aplicou-se cargas axiais e oblíquas (15 graus) de 0,5 Kgf através de uma máquina de teste universal e um polariscópio circular foi utilizado para visualizar as tensões. Os resultados foram analisados, quantitativamente, através do programa Fringes®, em plataforma MATLAB do LPM/ FEMEC/UFU. Todos os implantes curtos apresentaram maiores níveis de tensão que os implantes longos, independente do sistema e da direção do carregamento. Os implantes curtos do sistema Neodent apresentaram maiores níveis de tensão na área cervical, quando comparados à mesma região dos implantes do sistema Bicon, sob carregamento oblíquo. O carregamento oblíquo resultou em maiores níveis de tensão nos implantes curtos do sistema Neodent que o carregamento axial. Dentro dos limites deste estudo conclui-se que implantes curtos estão sujeitos a maior tensão em consequência de cargas, quando comparados aos implantes longos / Abstract: The aim of this study was to compare, in vitro, the role of conventional and short implants of different implant systems, under axial and oblique loading, in stress distribution with photoelastic models. Sixteen models were fabricated with photoelastic resin (GIII Flexible Resin and hardener CMR-201-252 CME / Polipox ® Industria e Comercio Ltda, São Paulo, SP, Brazil), with dimensions 40x50x12 mm, containing different implants systems and different implant lengths. The models were divided into four groups: Group I (n=4) - conventional Neodent implant (5 x 11 mm); Group II (n=4) - conventional Bicon implant (5 x 11 mm); Group III (n=4) - short Neodent implant (5 x 6 mm); Group IV (n=4) - short Bicon implant (5 x 6 mm). Four prosthetic crowns made of cobalt chromium alloy were cimented on the abutments (3.5 mm in height). For the short implants the prosthesis dimensions were 13 mm in height, 10 mm mesiodistally and 8 mm buccolingually. The prosthesis for conventional implants had 8 mm in height, 10 mm mesiodistally and 8 mm buccolingually. Axial and oblique load (15 degrees) of 0.5 kgf was applied by a universal testing machine and a circular polariscope was used to visualize the stress. The results were analysed quantitatively by Fringes® program, in LPM/ FEMEC / UFU MATLAB platform. All short implants had higher stress levels than the conventional implants, regardless of the implant system and the load direction. The short Neodent implants system had higher levels of stress in the cervical third, compared to the same area of the Bicon implants system, under oblique loading. The oblique load resulted in higher levels of stress in the short Neodent implants system than the axial load. Thus, within the limits of this study, short implants are subjected to higher levels of stress as a result of loads when compared to conventional implants / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289420
Date20 August 2018
CreatorsFigueirêdo, Evandro Portela, 1974-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Albergaria-Barbosa, José Ricardo de, 1956-, Rabelo, Luis Raimundo Serra, Silva, Wander José da
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format72 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0031 seconds