Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-10-30T02:02:42Z
No. of bitstreams: 1
Dissertação Uenderson Araujo Barbosa.pdf: 592474 bytes, checksum: 2e0c9a260b9c409a84412c05d6c29b53 (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-10-30T02:11:34Z (GMT) No. of bitstreams: 1
Dissertação Uenderson Araujo Barbosa.pdf: 592474 bytes, checksum: 2e0c9a260b9c409a84412c05d6c29b53 (MD5) / Made available in DSpace on 2014-10-30T02:11:34Z (GMT). No. of bitstreams: 1
Dissertação Uenderson Araujo Barbosa.pdf: 592474 bytes, checksum: 2e0c9a260b9c409a84412c05d6c29b53 (MD5) / A poluição da água por metais tem recebido muita atenção devido à sua
toxicidade, baixa biodegradabilidade e alta bioacumulação destas
substâncias. Dentro deste contexto, o presente trabalho propõe a
determinação de As, Cd, Co, Cr, Hg, Mn, Pb e Sb em amostras de água
potável, de rio e de cisternas coletadas no município de Cachoeira-Bahia,
usando espectrometria de massas com plasma indutivamente acoplado. Os
dados obtidos foram avaliados utilizando ferramentas de análise
multivariada (PCA e HCA) no intuito de verificar a similaridade das
amostras coletadas, aumentando a compreensão do comportamento do
conjunto de dados. A precisão do método utilizado na determinação foi
expressa como desvio padrão relativo (% RSD), os valores variaram entre
0,79 e 5,63% para soluções de concentrações de 0,2 a 25 μg L-1, para
todos os analitos. A exatidão foi confirmada pela determinação dos analitos
em materiais de referência certificado e teste de adição e recuperação com
recuperações entre 88,4 e 109,8 %. Foram coletadas 72 amostras de locais
do município de Cachoeira. Os valores de concentrações encontrados para
as amostras de água variaram entre 0,301 e 2,813 g L-1 para arsênio,
0,037 e 0,587 g L-1 para cádmio, 0,022 e 1,132 g L-1 para cobalto, 0,046
e 12,74 g L-1 para cromo, 0,031 e 0,982 g L-1 para mercúrio, 0,345 e
40,56 g L-1 para manganês, 0,025 e 10,85 g L-1 para chumbo e 0,011 e
0,756 g L-1 para antimônio. Todas as concentrações encontradas nas
amostras analisadas estavam abaixo do limite máximo estabelecido pelo
Ministério da Saúde. A análise exploratória demonstrou que houve
diferenciação entre os tipos de amostras, principalmente para as amostras
de água de cisterna. / The water pollution by metal has received great attention due to it's toxicity,
low biodegradability and high bioaccumulation. In this context, this paper
has the objective of determinate the concentration of As, Cd, Co, Cr, Hg,
Pb, Sd in potable, river and cistern water samples consumed in Cachoeira,
Bahia, using inductively coupled plasma mass spectrometry. The obtained
data was evaluated utilizing multivariated analysis tools (PCA and HCA) to
verify the characterization of the collected samples and help comprehend
the data. At first, the pH of the samples was evaluated between 6.5 and 7.8,
values in accordance with the table values indicated by the Ministry of
Health, between 6.0 and 8.0. The precision of the utilized method was
expressed as relative standard deviation (RSD), with values variating
between 0.79 and 5.63 % in solutions with a concentration between 0.2 and
25 g L-1, of all analytes. The accuracy of this method was confirmed by the
evaluation of analytes in certified reference materials and Spike test
(addition/recovery) with recovery variating between 88.4 % and 109.8 %. 72
samples were collected from various points in Cachoeira. The concentration
values for the water samples variated between 0.301 and 2.813 g L-1 for
arsenic, 0.037 and 0.587 g L-1 for cadmium, 0.022 and 1.132 g L-1 for
cobalt, 0.046 and 12.74 g L-1 for chromium, 0.031 and 0.982 g L-1 for
mercury, 0.345 and 40.56 g L-1 for manganese, 0.025 and 10.85 g L-1 for
lead and 0.011 and 0.756 g L-1 for antimony. All the concentrations
evaluated on the samples were below the maximum established by the
Ministry of Health. The exploratory sample was an important tool in the
characterization of the evaluated samples, because of the differentiation
between the kinds of samples for all the analytes determinate, mainly for the
cistern water samples
Identifer | oai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/16480 |
Date | 04 1900 |
Creators | Barbosa, Uenderson Araújo |
Contributors | Santos, Ana Maria Pinto dos, Bezerra, Marcos de Almeida, Andrade, Jailson Bittencourt de |
Publisher | Instituto de Química, Química, UFBA, brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds