Return to search

Qualidade da operação e manutenção do sistema de distribuição de água Costa Sul Leste em Florianópolis/SC com base em histórico de dados de autorização de serviço

Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2015. / Made available in DSpace on 2016-05-24T17:22:30Z (GMT). No. of bitstreams: 1
338948.pdf: 3799152 bytes, checksum: 91ced3ef00b49bb79f53c785d03caa37 (MD5)
Previous issue date: 2015 / A cobertura por acesso a água potável canalizada vem crescendo gradativamente, contudo, questões de qualidade de serviço: intermitência no abastecimento, baixa qualidade nos reparos, desperdícios entre outros, ainda são um problema. Foi avaliado a qualidade dos serviços de operação e manutenção do Sistema de Abastecimento de à gua Costa Sul Leste (SCSL) em Florianópolis/SC atendido pela Companhia Catarinense de à guas e Saneamento (CASAN). O estudo considerou registros históricos de 2009 a 2013 de autorização de serviço (AS) de rompimento de redes, ramais prediais, cavaletes e falta de água. Dividiu-se a área em 6 setores para obtenção dos dados comerciais e de operação, com os seguintes objetivos: caracterizar por meio de indicadores de desempenho (ID) os serviços prestados, avaliar o uso do atual modelo de AS como fonte de dados gerenciais e propor um modelo de priorização de reparo de vazamentos. Foi aplicado o método de análise e solução de problemas (MASP) e a ferramenta ID, para diagnosticar o serviço prestado e determinar as causas raiz do problema vazamento e tempo de reparo. Mapas temáticos permitiram visualizar geograficamente as ocorrências e possíveis relações com pressões do sistema. O tratamento dos dados proporcionou confiabilidade das informações geradas. Como resultado, observou-se que o ID Op31 - avarias em redes de água, diminuiu ao longo dos anos, sendo iguais a 149 e 125 avarias/100 km de rede nos setores 5 e 2 respectivamente, maiores resultados do ano de 2013. O setor 5 também apresentou o maior valor para o ID Op32 - avarias em ramais prediais e o segundo maior valor para o ID Op32 - avarias em cavaletes, iguais a 75 e 88 avarias/1000 ramais, nessa ordem. Segundo a classificação da ERSAR de Portugal, a área em estudo foi considerada de qualidade de serviço insatisfatória. Contudo, mostrou resultados próximos ou melhores do que algumas referências nacionais e internacionais mencionadas. Os possíveis fatores de causa de vazamentos na rede apontados foram: pressão, falha na obra de assentamento, má qualidade dos materiais utilizados, falta de treinamento e idade de rede. Os vazamentos são intensificados no verão devido intermitências no fornecimento de água e transientes hidráulicos por manobras de rede. O tempo de reparo aumentou ao longo dos anos de estudo em redes até DN 100 mm, passando de 11 para 21 horas/serviço de 2009 à 2013. O prolongamento do tempo ao longo dos anos de estudo foi associado com aumento do trânsito de veículos, estoque de materiais, falta de procedimentos padrões, comunicação com a população entre outros. Como proposta final desse trabalho, foi produzido um plano para a redução das perdas reais de água por meio da utilização da AS como fonte de dados, e sugerido o relato da caracterização do vazamento no instante do conserto. Ademais, foi proposto um modelo de priorização de reparo visando reduzir o volume de água perdido por vazamento, apoiar a padronização da operação e manutenção dos sistemas de distribuição de água e, consequentemente, melhoraria da qualidade do serviço prestado.<br> / Abstract : Coverage for access to piped drinking water is increasing gradually, Although, the service quality issues: intermittent supply, low quality of repairs, water waste, among others, are still a problem. The quality of operation and maintenance services provided in the water supply system in the south east coast of the city of Florianópolis operated by Companhia Catarinense de à guas e Saneamento (CASAN) was evaluated. The study considered historical records from 2009 to 2013 of order service (OS) of water main breaks, branches connections, easel and lack of water. It was divided the area into 6 sectors for obtaining commercial and operation data, with the following objectives: to characterize by performance indicators (PI) the services provided, to evaluate the use of the current OS model as a source of management data and propose a leak repair prioritization model. The method of quality control story (QC Story) was applied and the PI to diagnose the service and determine the root causes of the leak problem and repair time. Thematic maps allow to visualize geographically the events and possible relationships with system pressures. The data treatment stage provided reliability of the information generated. As a result, it was observed that the PI 31 ? breakdowns in water supply networks, decreased over the years and is equal to 149 and 125 breakdowns/100 km network in the sectors 5 and 2 respectively, highest results for the year 2013. The sector 5 also had the highest value for PI 32 ? breakdowns branches connections and second highest value for PI 32 ? breakdowns on easels, equal to 75 and 88 breakdowns/1000 branches connections in this order. According to the classification of ERSAR from Portugal, the study area was considered of poor quality service. However, it showed results similar to or better than some national and international mentioned references. Possible causes of leaks in networks were pointed: network pressure, failure of the pipe laying work, poor quality of the materials, lack of training and old network. Leaks are intensified in the summer due to intermittent breaks in water supply and hydraulic transients resulting from mains water maneuvers. The time of repair has increased over the years of study in networks up to diameter 100 mm, from 11 to 21 hours/service, 2009 to 2013. The increased time of repair over the years was associatedwith increased vehicle traffic, stock materials, lack of standard procedures, communication with the public and others. As a final proposal was produced a plan to reduce the real water loss through the use of OS like a data source, and suggested the report of the leakage characteristics at the time of repair. In addition, a repair prioritization model was proposed in order to decrease the volume of water lost through leakage, support the standardization of operation and maintenance of water distribution systems and, consequently, improve the quality of service.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/162572
Date January 2015
CreatorsSoares, Andréia Senna
ContributorsUniversidade Federal de Santa Catarina, Dalsasso, Ramon Lucas
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format197 p.| il., grafs., tabs.
Sourcereponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds